6005 – 500 VA<<strong>br</strong> />

6010 – 1 KVA<<strong>br</strong> />

6020 – 2 KVA<<strong>br</strong> />

6040 – 4 KVA<<strong>br</strong> />

<strong>6000</strong> <strong>Series</strong><<strong>br</strong> />

Automated AC Power Sources<<strong>br</strong> />

Features<<strong>br</strong> />

• Graphic Liquid Crystal Display<<strong>br</strong> />

• Encoder wheel to adjust voltage and frequency during a test<<strong>br</strong> />

• Test/reset key to activate and disable output<<strong>br</strong> />

• Universal receptacle to handle multiple<<strong>br</strong> />

country configurations<<strong>br</strong> />

• RS-232 interface standard – GPIB optional<<strong>br</strong> />

• 50 memories with 9 steps per memory<<strong>br</strong> />

• PLC output for Pass/Fail/Test-in-Process<<strong>br</strong> />

• Prompt feature to add instructions to a test<<strong>br</strong> />

• Over current fold back<<strong>br</strong> />

• Front panel lockout<<strong>br</strong> />

• Enhanced protection circuits<<strong>br</strong> />

• Fully programmable parameters high/low limits for voltage,<<strong>br</strong> />

amps and frequency<<strong>br</strong> />

• Programmable test time, delay time, and ramp timers<<strong>br</strong> />

• Programmable surge/drop voltage, start/end angle<<strong>br</strong> />

1142 S. Diamond Bar Blvd. #106, Diamond Bar, CA USA 91765 •• P: +1-909-860-1646 •• F: +1-909-992-3307 •• www.aspowertechnologies.<strong>com</strong>


Specifications<<strong>br</strong> />

Input<<strong>br</strong> />

Phase<<strong>br</strong> />

6005/6010/6020/6040 1 Ø<<strong>br</strong> />

Voltage<<strong>br</strong> />

6005/6010 115/230 Vac ± 10%<<strong>br</strong> />

6020/6040 208 Vac ± 15%<<strong>br</strong> />

OPTION: 230 Vac ± 10%<<strong>br</strong> />

Frequency<<strong>br</strong> />

6005/6010/6020/6040 47 - 500 Hz<<strong>br</strong> />

Measurement (continued)<<strong>br</strong> />

Frequency<<strong>br</strong> />

6005/6010/6020/6040 Range: 0.0 - 500.0 Hz<<strong>br</strong> />

Resolution: 0.1 Hz<<strong>br</strong> />

Accuracy: ± 0.1 Hz<<strong>br</strong> />

Current (RMS)<<strong>br</strong> />

6005 Range: 0.005 - 6.50 A<<strong>br</strong> />

Resolution: Low Range: 0.001 A<<strong>br</strong> />

High Range: 0.01 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

Output<<strong>br</strong> />

Power Rating<<strong>br</strong> />

6005 500 VA<<strong>br</strong> />

6010 1000 VA<<strong>br</strong> />

6020 2000 VA<<strong>br</strong> />

6040 4000 VA<<strong>br</strong> />

Max. Current (RMS)<<strong>br</strong> />

6005 0 - 150 V: 4.6 A Low Range<<strong>br</strong> />

0 - 300 V: 2.3 A High Range<<strong>br</strong> />

6010 0 - 150 V: 9.2 A Low Range<<strong>br</strong> />

0 - 300 V: 4.6 A High Range<<strong>br</strong> />

6020 0 - 150 V: 18.4 A Low Range<<strong>br</strong> />

0 - 300 V: 9.2 A High Range<<strong>br</strong> />

6040 0 - 150 V: 36.8 A Low Range<<strong>br</strong> />

0 - 300 V: 18.4 A High Range<<strong>br</strong> />

Frequency<<strong>br</strong> />

6005/6010/6020/6040 Range: 47 - 450 Hz<<strong>br</strong> />

Phase<<strong>br</strong> />

6005/6010/6020/6040 1 Ø/2 W<<strong>br</strong> />

Total Harmonic<<strong>br</strong> />

Distortion (T.H.D)<<strong>br</strong> />

6005/6010/6020/6040 < 0.5% at 40 - 100 Hz<<strong>br</strong> />

< 1% at 101 - 450 Hz<<strong>br</strong> />

(Resistive Load)<<strong>br</strong> />

Crest Factor<<strong>br</strong> />

6005/6010/6020/6040 ≥ 3<<strong>br</strong> />

Line Regulation<<strong>br</strong> />

6005/6010/6020/6040 ± 0.1 V<<strong>br</strong> />

Load Regulation<<strong>br</strong> />

6005/6010/6020/6040 ± (0.5% of output +0.5 V)<<strong>br</strong> />

at Resistive Load<<strong>br</strong> />

Response Time<<strong>br</strong> />

6005/6010/6020/6040 < 400 µ/sec<<strong>br</strong> />

Measurement<<strong>br</strong> />

Voltage<<strong>br</strong> />

6005/6010/6020/6040 Range: 0.0 - 400.0 V<<strong>br</strong> />

Resolution: 0.1 V<<strong>br</strong> />

Accuracy: ± (1% of reading +2 counts)<<strong>br</strong> />

Current (peak)<<strong>br</strong> />

Power<<strong>br</strong> />

6010 Range: 0.005 - 13.00 A<<strong>br</strong> />

Resolution: Low Range: 0.001 A<<strong>br</strong> />

High Range: 0.01 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6020 Range: 0.005 - 26.00 A<<strong>br</strong> />

Resolution: Low Range: 0.001 A<<strong>br</strong> />

High Range: 0.01 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6040 Range: 0.00 - 52.00 A<<strong>br</strong> />

Resolution: Low Range: 0.001 A<<strong>br</strong> />

High Range: 0.01 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6005 Range: 0.0 - 19.0 A<<strong>br</strong> />

Resolution: 0.1 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6010 Range: 0.0 - 38.0 A<<strong>br</strong> />

Resolution: 0.1 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6020 Range: 0.0 - 76.0 A<<strong>br</strong> />

Resolution: 0.1 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6040 Range: 0.0 - 152.0 A<<strong>br</strong> />

Resolution: 0.1 A<<strong>br</strong> />

Accuracy: ± (1% of reading +5 counts)<<strong>br</strong> />

6005 Range: 0.0 - 650 W<<strong>br</strong> />

Resolution: Low Range: 0.1 W<<strong>br</strong> />

High Range: 1 W<<strong>br</strong> />

Accuracy: ± (2% of reading +2 counts)<<strong>br</strong> />

6010 Range: 0.0 - 1300W<<strong>br</strong> />

Resolution: Low Range: 0.1W<<strong>br</strong> />

High Range: 1W<<strong>br</strong> />

Accuracy: ± (2% of reading +2 counts)<<strong>br</strong> />

6020 Range: 0.0 - 2600 W<<strong>br</strong> />

Resolution: Low Range: 0.1 W<<strong>br</strong> />

High Range: 1 W<<strong>br</strong> />

Accuracy: ± (2% of reading +2 counts)<<strong>br</strong> />

6040 Range: 0.0 - 5200 W<<strong>br</strong> />

Resolution: Low Range: 0.1 W<<strong>br</strong> />

High Range: 1 W<<strong>br</strong> />

Accuracy: ± (2% of reading +2 counts)


Specifications<<strong>br</strong> />

Measurement (continued)<<strong>br</strong> />

Power Factor<<strong>br</strong> />

6005/6010/6020/6040 Range: 0.000 - 1.000<<strong>br</strong> />

Resolution: 0.001<<strong>br</strong> />

Accuracy: W/VA, Calculated and displayed<<strong>br</strong> />

to three signifi cant digits<<strong>br</strong> />

Inrush Current<<strong>br</strong> />

6005/6010/6020/6040 4 times the rated current<<strong>br</strong> />

Enhanced Over<<strong>br</strong> />

Load Capacity<<strong>br</strong> />

6005/6010/6020/6040 4 times the rated current,<<strong>br</strong> />

Short Circuit hold for 1000 ms<<strong>br</strong> />

Settings<<strong>br</strong> />

Remote Input Signal<<strong>br</strong> />

Interface (Option)<<strong>br</strong> />

6005/6010/6020/6040 Test, Reset, Recall memory<<strong>br</strong> />

1 through 7<<strong>br</strong> />

Remote Output Signal<<strong>br</strong> />

6005/6010/6020/6040 Pass, Fail, Test-in-Process<<strong>br</strong> />

Surge/Drop Voltage<<strong>br</strong> />

6005/6010/6020/6040 Selectable On/Off<<strong>br</strong> />

Auto Run Mode<<strong>br</strong> />

Selection<<strong>br</strong> />

6005/6010/6020/6040 Program/Manual<<strong>br</strong> />

Sync Output Signal<<strong>br</strong> />

6005/6010/6020/6040 DC Level 5 V<<strong>br</strong> />

Timer<<strong>br</strong> />

6005/6010/6020/6040 0 = Continuous, 0.1 - 999.9<<strong>br</strong> />

Alarm Volume Setting<<strong>br</strong> />

6005/6010/6020/6040 Range: 0 - 9; 0 = OFF<<strong>br</strong> />

Auto Loop Cycle<<strong>br</strong> />

6005/6010/6020/6040 0 = Continuous, 1 = OFF, 0 - 9999<<strong>br</strong> />

Over Current Fold<<strong>br</strong> />

Back Mode<<strong>br</strong> />

6005/6010/6020/6040 On/Off Setting < 700 ms<<strong>br</strong> />

Single Step<<strong>br</strong> />

6005/6010/6020/6040 On/Off Setting<<strong>br</strong> />

Contrast<<strong>br</strong> />

6005/6010/6020/6040 Range: 1 - 9<<strong>br</strong> />

Power Up<<strong>br</strong> />

6005/6010/6020/6040 Selectable On, Off, Last<<strong>br</strong> />

Timer Units<<strong>br</strong> />

6005/6010/6020/6040 Selectable Second, Minute, Hour<<strong>br</strong> />

Hi & Lo Volt<<strong>br</strong> />

6005/6010/6020/6040 Adjustable 0 - 300 V<<strong>br</strong> />

Hi & Lo Frequency<<strong>br</strong> />

6005/6010/6020/6040 Adjustable 40 - 500 Hz<<strong>br</strong> />

Settings (continued)<<strong>br</strong> />

End & Start Angle<<strong>br</strong> />

6005/6010/6020/6040 Adjustable 0 - 359°<<strong>br</strong> />

Results<<strong>br</strong> />

6005/6010/6020/6040 Selectable All, Pass/Fail, Last<<strong>br</strong> />

General<<strong>br</strong> />

Memory<<strong>br</strong> />

6005/6010/6020/6040 50 memories, 9 steps/memory<<strong>br</strong> />

High/Low Limit<<strong>br</strong> />

Protection<<strong>br</strong> />

6005/6010/6020/6040 Arms, Apeak, P, PF<<strong>br</strong> />

Protection<<strong>br</strong> />

6005/6010/6020/6040 Over Current Protection, Over Voltage<<strong>br</strong> />

Protection, Over Power Protection,<<strong>br</strong> />

Over Temperature Protection, Alarm<<strong>br</strong> />

Interface (Option)<<strong>br</strong> />

6005/6010/6020/6040 GPIB/RS232, PLC Remote<<strong>br</strong> />

Input Card<<strong>br</strong> />

Cali<strong>br</strong>ation<<strong>br</strong> />

6005/6010/6020/6040 Front Panel Cali<strong>br</strong>ation<<strong>br</strong> />

Efficiency<<strong>br</strong> />

6005/6010/6020/6040 ≥ 80% (at Full Load)<<strong>br</strong> />

Operation<<strong>br</strong> />

Environment<<strong>br</strong> />

6005/6010/6020/6040 0 - 40°C/20 - 80% RH<<strong>br</strong> />

Mechanical<<strong>br</strong> />

Fan<<strong>br</strong> />

6005/6010/6020/6040 Built-in Cooling Fan<<strong>br</strong> />

Front Panel Output<<strong>br</strong> />

6005/6010/6020/6040 Universal Receptacle<<strong>br</strong> />

Rear Panel Output<<strong>br</strong> />

6005/6010/6020 Universal Receptacle<<strong>br</strong> />

6040 Terminal Block (L, N, G)<<strong>br</strong> />

Dimension<<strong>br</strong> />

(W×H×D, mm)<<strong>br</strong> />

6005/6010 430 x 89 x 400<<strong>br</strong> />

6020 430 x 89 x 500<<strong>br</strong> />

6040 430 x 222 x 500<<strong>br</strong> />

Net Weight<<strong>br</strong> />

6005 35 lbs<<strong>br</strong> />

6010 42 lbs<<strong>br</strong> />

6020 68 lbs<<strong>br</strong> />

6040 143 lbs<<strong>br</strong> />

<strong>APT</strong>...Power On!


Associated Power Technologies, Inc. (<strong>APT</strong>) provides<<strong>br</strong> />

superior products and services to a variety of test &<<strong>br</strong> />

measurement, avionics, manufacturing, and military<<strong>br</strong> />

applications requiring power conversion equipment.<<strong>br</strong> />

Our AC power sources are feature rich and highly<<strong>br</strong> />

adaptable to multiple applications. Our engineering<<strong>br</strong> />

group is focused on providing the latest technology to<<strong>br</strong> />

meet and exceed your expectations. We do this while<<strong>br</strong> />

keeping our power sources <strong>com</strong>petitively priced.<<strong>br</strong> />

Our value goes far beyond what our <strong>com</strong>petition<<strong>br</strong> />

can provide. In addition to offering innovative and<<strong>br</strong> />

<strong>com</strong>petitively priced products, all of our power sources<<strong>br</strong> />

are stocked and we guarantee to ship any instrument<<strong>br</strong> />

within 24 hours! We understand that your need for<<strong>br</strong> />

quality instrumentation is immediate and it hurts your<<strong>br</strong> />

bottom line to wait weeks for a piece of equipment.<<strong>br</strong> />

Furthermore, all of our power sources <strong>com</strong>e with a<<strong>br</strong> />

45 day satisfaction guaranteed. This means that if<<strong>br</strong> />

you are unhappy with your purchase for any reason<<strong>br</strong> />

whatsoever, then you can simply return your power<<strong>br</strong> />

source to us within 45 days and we give you a full<<strong>br</strong> />

refund or credit towards another <strong>APT</strong> power source –<<strong>br</strong> />

no questions asked.<<strong>br</strong> />

We provide world class customer support and service<<strong>br</strong> />

so you can be confi dent that we will always be there<<strong>br</strong> />

standing behind our products. Our elite engineering<<strong>br</strong> />

group continues to develop exciting products to meet<<strong>br</strong> />

new testing demands. We can do this and more<<strong>br</strong> />

because we place our focus on you, the customer!<<strong>br</strong> />

<strong>APT</strong>...Power On!<<strong>br</strong> />

<strong>APT</strong> offers two distinct lines of AC power sources: Our<<strong>br</strong> />

<strong>6000</strong> series of automated AC power sources and our<<strong>br</strong> />

5000 series of manual AC power sources.<<strong>br</strong> />

1142 S. Diamond Bar Blvd. #106, Diamond Bar, CA USA 91765 •• P: +1-909-860-1646 •• F: +1-909-992-3307 •• www.aspowertechnologies.<strong>com</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!