25.01.2015 Views

AIR C R A FT Anti-Ice / Starting Bleed Control Valve - Vacco

AIR C R A FT Anti-Ice / Starting Bleed Control Valve - Vacco

AIR C R A FT Anti-Ice / Starting Bleed Control Valve - Vacco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Anti</strong>-<strong>Ice</strong> / <strong>Starting</strong> <strong>Bleed</strong> <strong>Control</strong> <strong>Valve</strong> 73340-20<br />

This modulating poppet valve was designed to perform<br />

dual functions on gas turbine engines:<br />

1. Provide hot air flow for engine anti-ice protection.<br />

2. Automatically bleed air from the engine during<br />

the starting cycle.<br />

The valve features two independent outlets with proportionate<br />

flows between them. During starting, this unit is<br />

full open to provide maximum bleed. An engine operated<br />

cam within the valve closes the valve automatically<br />

upon completion of the starting cycle.<br />

Actuation of a solenoid switches the valve to the antiicing<br />

mode where a cam schedules the correct flow<br />

area for anti-icing.<br />

<strong>AIR</strong>CRA<strong>FT</strong><br />

Features<br />

• Position indication<br />

• High temperature capability<br />

• Lightweight; approximately 5 lbm<br />

• Compact, long life<br />

• No lubrication required<br />

Operating Parameters<br />

Operating Pressure Range ........................0 to 50 psig<br />

Proof Pressure ................................................100 psia<br />

Burst Pressure ................................................165 psia<br />

Media Temperature............................. -65ºF to +480ºF<br />

Ambient Temperature Range.............. -65ºF to +250ºF<br />

Operating Leakage ................................... 0.15 lbs/min<br />

Non-Operating Leakage............................ 0.45 lbs/min<br />

Operating Voltage ...................................16 to 30 VDC<br />

Maximum Current Consumption ........................ 1 amp<br />

Flow<br />

Start <strong>Bleed</strong> ..................................... 0 to 0.64 lbs/sec<br />

<strong>Anti</strong>-icing ................................... 0.34 to 0.66 lbs/sec<br />

Weight..................................................................5 lbm<br />

Performance characteristics are based on customer requirements. As such, they are not representative of component capabilities or limitations.<br />

VACCO Industries | 10350 <strong>Vacco</strong> Street | South El Monte, CA 91733<br />

T: (626) 443-7121 | F: (626) 442-6943 | E: aircraft@vacco.com | W: www.vacco.com<br />

A Subsidary of ESCO Technologies Inc.<br />

© VACCO Industries Rev 9/12


Envelope Drawings<br />

73340-20<br />

Electric Schematic<br />

VACCO Industries | 10350 <strong>Vacco</strong> Street | South El Monte, CA 91733<br />

T: (626) 443-7121 | F: (626) 442-6943 | E: aircraft@vacco.com | W: www.vacco.com<br />

A Subsidary of ESCO Technologies Inc.<br />

© VACCO Industries Rev 9/12