5.2 AUTOMATIC OPERATION (FB4/FBH4/FB5/FB6)<br />
1. The <strong>Tron</strong> <strong>40S</strong> <strong>MkII</strong> will automatically release from the bracket, float to the<br />
surface and start to transmit when the EPIRB, in its bracket is deployed into<br />
water at a depth of app. 2-4 meters (6 - 13 feet).<br />
2. Transmission will continue until the EPIRB is lifted out of the water, and<br />
dried off. The transmission can also be stopped by placing the EPIRB in the<br />
bracket. (If switch is in ”READY” position, otherwise move switch to this position).<br />
5.3 TEST<br />
To perform the self-test, the EPIRB has to be removed from the bracket.<br />
FB4 bracket: Remove EPIRB from the bracket by pulling out the locking pin on<br />
the clamp and open the retaining rod that holds the beacon.<br />
FB6/FB5 bracket: Release top cover by removing the locking split pin and special<br />
washer.<br />
26<br />
82819_UM_<strong>40S</strong><strong>MkII</strong>_J