14.11.2012 Views

VT4.10 - 4.40 Series 100% OIL-LESS VACUUM PUMPS

VT4.10 - 4.40 Series 100% OIL-LESS VACUUM PUMPS

VT4.10 - 4.40 Series 100% OIL-LESS VACUUM PUMPS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FLOW (CFM)<br />

<strong>VT4.10</strong> - <strong>4.40</strong> <strong>Series</strong><br />

<strong>100%</strong> <strong>OIL</strong>-<strong>LESS</strong> <strong>VACUUM</strong> <strong>PUMPS</strong><br />

The Becker <strong>VT4.10</strong> - <strong>4.40</strong> series pumps are <strong>100%</strong> oilless<br />

rotary vane vacuum pumps. They are designed<br />

to operate on a continuous basis at any<br />

point from atmospheric pressure to<br />

a vacuum level of 25” HgV.<br />

The VT series pumps are direct<br />

drive units and are supplied<br />

with an IP-54 TEFC electric motor.<br />

Each pump is equipped with<br />

an integral vacuum relief valve,<br />

a 10µ inlet filter, and vibration isolators<br />

as standard equipment.<br />

Becker VT series pumps have a reputation<br />

for being exceptionally quiet. These award-winning<br />

pumps are newly redesigned to make them even quieter,<br />

and cooler running than previous units. If you are<br />

28<br />

24<br />

20<br />

16<br />

12<br />

SCFM*<br />

SCFM*<br />

0<br />

0 4 8 12 16 20 24 28<br />

* @ 29.92" Hg Bar. Pr.; 68 o F; 36% R.H.; 0.075#/ft 3<br />

ISO 9001 Certified<br />

Compliant<br />

760 625 500 375 250 125 0<br />

2.0<br />

8<br />

4<br />

VT<strong>4.40</strong><br />

VT4.25<br />

VT4.16<br />

<strong>VT4.10</strong><br />

ACFM<br />

ACFM<br />

ACFM<br />

ACFM<br />

ABSOLUTE PRESSURE (TORR)<br />

SCFM*<br />

Becker Pumps Corp. • 100 East Ascot Lane • Cuyahoga Falls, Ohio 44223-3768<br />

Ph. (330) 928-9966 • FAX: (330) 928-7065 • e-mail: info@beckerpumps.com • beckerpumps.com<br />

SCFM*<br />

2 6 10 14 18 22 26 30<br />

<strong>VACUUM</strong> (In. HgV)<br />

an OEM, their styling will never cause embarrassment<br />

when included with your product.<br />

These <strong>100%</strong> oil-less, or dry, pumps are ideal for<br />

applications where oil or water is objectionable.<br />

All Becker VT pumps use longlife,<br />

self-lubricating graphite<br />

composite vanes. Applications<br />

include the graphic arts,<br />

packaging, vacuum chucking,<br />

robotics and material handling,<br />

medical/surgical, and<br />

air sampling, among others.<br />

These pumps are also available<br />

in various central vacuum<br />

system configurations. Pressure and combined<br />

pressure/vacuum pumps are available.<br />

25<br />

BHP<br />

Contact the<br />

factory for<br />

operation<br />

in the<br />

shaded area<br />

BHP<br />

BHP<br />

BHP<br />

Max. allowable vacuum<br />

level for continuous<br />

operation<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

POWER REQUIREMENTS (BHP)


e<br />

s<br />

h<br />

3<br />

i<br />

h 1<br />

q<br />

o<br />

k<br />

Top View<br />

Side View<br />

g 1<br />

a<br />

f<br />

k 1<br />

b<br />

f 1<br />

End View (Opposite Motor End)<br />

g<br />

g 2<br />

2<br />

c<br />

1<br />

h 3<br />

4<br />

h 4<br />

h 5<br />

cs<br />

3<br />

All data based on 60 Hz operation<br />

Flow (SCFM @ 0 in. Hg)<br />

Horsepower<br />

Speed (RPM)<br />

Max. Cont. Vacuum (in. HgV)<br />

Weight (lbs.)—w/ motor*<br />

Noise Level (Max. dBA)<br />

Inlet size (BSP, inches)<br />

Dimensional Data<br />

a<br />

b<br />

c<br />

cs<br />

e<br />

f<br />

f 1<br />

g<br />

g 1<br />

g 2<br />

h<br />

h 1<br />

h 3<br />

h 4<br />

h 5<br />

i<br />

k<br />

k 1<br />

o<br />

q<br />

s<br />

TECHNICAL DATA<br />

Becker Pumps Corp. • 100 East Ascot Lane • Cuyahoga Falls, Ohio 44223-3768<br />

Ph. (330) 928-9966 • FAX: (330) 928-7065 • e-mail: info@beckerpumps.com • beckerpumps.com<br />

<strong>VT4.10</strong><br />

7.1<br />

0.6<br />

1740<br />

25<br />

35.2<br />

62<br />

1⁄2<br />

6.3<br />

4.41<br />

0.6<br />

0.12<br />

1.38<br />

7.88<br />

5.6<br />

8.11<br />

3.54<br />

3.54<br />

4.21<br />

6.66<br />

6.93<br />

7.44<br />

7.68<br />

4.17<br />

15.25<br />

16.9<br />

10.12<br />

4.84<br />

0.27<br />

VT4.16<br />

1 - Inlet Port<br />

2 - Vibration Isolator<br />

3 - Vacuum Regulating Valve<br />

4 - Exhaust Air Silencer<br />

VT4.25<br />

(Inches)<br />

* Overall specifications for single phase units may vary. Contact factory for information.<br />

Manufacturer reserves right to alter data without notice.<br />

11<br />

0.94<br />

1740<br />

25<br />

50<br />

64<br />

1⁄2<br />

7.95<br />

4.92<br />

0.6<br />

0.12<br />

1.38<br />

9.53<br />

6.1<br />

9.1<br />

4.03<br />

4.03<br />

4.45<br />

7.4<br />

7.32<br />

8.07<br />

8.3<br />

2.88<br />

16.38<br />

17.8<br />

11.48<br />

5.97<br />

0.27<br />

18<br />

1.2<br />

1740<br />

25<br />

57.2<br />

67<br />

3⁄4<br />

8.66<br />

8.19<br />

0.6<br />

0.12<br />

1.57<br />

10.24<br />

9.37<br />

10.23<br />

4.92<br />

4.92<br />

5.51<br />

8.9<br />

8.9<br />

9.84<br />

11.42<br />

3.78<br />

18.31<br />

19.89<br />

11.91<br />

6.81<br />

0.27<br />

VT<strong>4.40</strong><br />

28<br />

2<br />

1740<br />

25<br />

84.7<br />

72<br />

3⁄4<br />

8.66<br />

8.19<br />

0.6<br />

0.12<br />

1.57<br />

10.24<br />

9.37<br />

11.03<br />

4.92<br />

4.92<br />

5.51<br />

8.9<br />

8.9<br />

9.84<br />

11.42<br />

5.15<br />

20.95<br />

22.53<br />

14.31<br />

7.56<br />

0.27<br />

3LIT0024 • 05/03