N-<strong>Comfort</strong><br />

<strong>Nexans</strong> <strong>Thermostat</strong> <strong>Programme</strong><br />

<strong>Nexans</strong> <strong>Thermostat</strong> <strong>Programme</strong>


N-<strong>Comfort</strong> <strong>Thermostat</strong> <strong>Programme</strong><br />

The N-<strong>Comfort</strong> thermostat programme<br />

adds a new and powerful dimension to<br />

<strong>Nexans</strong>’ heating system portfolio.<br />

Precise and accurate temperature control<br />

is important to fully achieve the advantages<br />

of floor heating without using more<br />

electric energy than necessary. Heating<br />

cables in combination with an accurate<br />

thermostat are probably the most energy<br />

efficient heating system one can have in<br />

a modern building.<br />

The design of the thermostat is unique, and<br />

every detail has been carefully designed<br />

paying special attention to aesthetic<br />

appear ance, user-friendliness and quality,<br />

as required and demanded by both<br />

consumers and professional installers.<br />

In addition to the thermostats being easy<br />

to install and adjust, the temperature is<br />

digitally controlled by software specifically<br />

developed for underfloor heating systems.<br />

The N-<strong>Comfort</strong> series comprises four<br />

different controllers – three thermostats<br />

and one power regulator. Whatever your<br />

need is, you will find a N-<strong>Comfort</strong> controller<br />

optimal for your needs. From just simple<br />

power control to advanced day/night<br />

control, N-<strong>Comfort</strong> will do the job!<br />

<strong>Nexans</strong> thermostat programme<br />

Type CDFR-001 CDFR-002 CEF-001 CR-001<br />

Description<br />

Programmable digital<br />

thermostat with room<br />

and floor sensor and<br />

day/night function<br />

Programmable digital<br />

thermostat with room<br />

and floor sensor and<br />

pre-programmed day/<br />

night function<br />

Electronic thermostat<br />

with room and floor<br />

sensor without day/night<br />

function<br />

Power regulator<br />

Application<br />

For indoor use in all<br />

room types<br />

For indoor use in all<br />

room types<br />

For indoor use in all<br />

room types<br />

For indoor use. Recommended<br />

in small rooms<br />

Technical data<br />

Rated Voltage<br />

230 VAC, 50 Hz<br />

230 VAC, 50 Hz<br />

230 VAC, 50 Hz<br />

230 VAC, 50 Hz<br />

Max. load<br />

3600 W, 16 A<br />

3600 W, 16 A<br />

3600 W, 16 A<br />

3600 W, 16 A<br />

IP Class<br />

IP21<br />

IP21<br />

IP21<br />

IP21<br />

Temperature scale<br />

+5 to +37 °C<br />

+5 to +37 °C<br />

+5 to +37 °C<br />

N/A<br />

Accuracy<br />

0.4 °C<br />

0.4 °C<br />

0.4 °C<br />

N/A<br />

Max. circuit breaker size<br />

16 A<br />

16 A<br />

16 A<br />

16 A<br />

Length of floor sensor<br />

3 m<br />

3 m<br />

3 m<br />

3 m<br />

On/off-switch<br />

Two-pole<br />

Two-pole<br />

Two-pole<br />

Two-pole<br />

Regulating period<br />

N/A<br />

N/A<br />

N/A<br />

30 min.<br />

Temperature limitation<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

Factory sensor setting<br />

Floor<br />

Room<br />

Floor<br />

N/A<br />

Optimising function<br />

Yes<br />

Yes<br />

No<br />

N/A


N-<strong>Comfort</strong> CDFR-001 and CDFR-002<br />

The N-<strong>Comfort</strong> CDFR range comprises<br />

programmable digital thermostats for<br />

use in all indoor room types. The two<br />

versions are delivered with different<br />

factory set-ups to make installation as<br />

quick and easy as possible, but both<br />

types can be programmed to fit the<br />

users’ needs in any room. The thermostats<br />

are equipped with both room and<br />

floor sensor. It is up to the installer to<br />

determine which sensor to activate. If<br />

necessary, both sensors can be activated.<br />

The floor sensor will then function<br />

as a temperature limitation sensor in<br />

order to avoid overheating of the floor.<br />

Factory settings:<br />

Model CDFR-001 CDFR-002<br />

Default sensor Floor Room<br />

Factory programming<br />

Recommended room types<br />

No factory set day/night<br />

programme<br />

Day/night function for<br />

weekdays and weekends<br />

can be programmed by<br />

the user<br />

• Bathroom<br />

• Washroom<br />

• Toilet<br />

• Concrete floors with high<br />

output in general<br />

4-event programme<br />

Weekdays, mon – fri:<br />

1.<br />

2.<br />

3.<br />

4.<br />

2-event programme<br />

Weekend:<br />

1.<br />

2.<br />

• Living room<br />

• Kitchen<br />

• Sleeping room<br />

• Hall<br />

• Living areas in general<br />

N-<strong>Comfort</strong> CEF-001<br />

The model CEF-001 is an electronic<br />

thermostat for use in all indoor room types.<br />

It is equipped with both a room and a<br />

floor sensor. Which sensor to use can<br />

be chosen by simply adjusting a jumper<br />

behind the front cover. If the floor sensor is<br />

the active sensor, it will also function as a<br />

temperature limitation sensor. The maximum<br />

allowed floor temperature can be set<br />

by adjusting a potentiometer positioned<br />

behind the front cover.<br />

The N-<strong>Comfort</strong> CEF-001 is recommended<br />

for use in all room types. It is especially<br />

suitable for bathrooms and other rooms<br />

with concrete floors and high output<br />

(100 – 150 W/m²).<br />

N-<strong>Comfort</strong> CR-001<br />

CR-001 is a power regulator with no<br />

sensor. By turning the wheel, the user can<br />

control the heating cable’s output. The<br />

regulator works with a cycle of 30 minutes.<br />

Turning the wheel tells the regulator how<br />

many minutes it shall stay on and off within<br />

the cycle.<br />

Example: The regulator wheel is put in<br />

position ”5”, pointing straight upwards.<br />

The regulator will turn the cables on for<br />

15 minutes and off for 15 minutes, working<br />

in 30 minute cycles. The resulting heating<br />

cable output is 50% of the nominal wattage.<br />

The N-<strong>Comfort</strong> CR-001 is recommended<br />

for use in small rooms with concrete floors<br />

like for example toilets, small bathrooms<br />

etc. It is also ideal for replacing old<br />

1-2-3-switches commonly used in the<br />

70’s and 80’s.<br />

CDFR-001 and CDFR-002<br />

CR-001 and CEF-001


Installation and use of the thermostat<br />

Ludens Reklamebyrå / 25 March 2008 / 3000<br />

Installation of floor sensor<br />

Applicable for: CDFR-001, CDFR-002,<br />

CEF-001<br />

Parts needed: Sensor (enclosed in<br />

thermostat package)<br />

Flexible conduit, same<br />

length as the sensor<br />

Piece of tape, approx.<br />

10 cm.<br />

Seal off the flexible conduit in the floor end<br />

with a piece of tape, and install it in the<br />

floor, centered between two heating cable<br />

strings. It should reach at least 50 cm into<br />

the floor. The other end of the conduit<br />

shall end up in the junction box where the<br />

thermostat shall be installed. Then feed the<br />

sensor into the conduit from the junction<br />

box end so that the end of the sensor ends<br />

up near the floor end of the conduit.<br />

Installation of the thermostat<br />

Applicable for: All models<br />

Parts needed: <strong>Thermostat</strong> or regulator<br />

Junction box<br />

Mounting screws to<br />

fasten the thermostat/<br />

regulator<br />

Make sure that the power supply is<br />

completely disconnected. Open the<br />

thermostat by using a small screwdriver<br />

and remove the frame and the front cover.<br />

Connect the heating cable, power leads<br />

and sensor (if applicable) to the correct<br />

terminals on the back side of the thermostat/<br />

regulator. Put the thermostat/regulator in<br />

place in the junction box and attach it with<br />

mounting screws. Put the frame and front<br />

cover in place and attach by applying a<br />

light pressure until a ”click” is heard.<br />

Full installation instructions are enclosed<br />

in the box.<br />

Save money with<br />

day/night temeperature control<br />

Using the day/night function in CDFR-001<br />

and CDFR-002 is likely to have a very<br />

positive impact on heating expenses. It<br />

is recommended to use this functionality<br />

in all living areas like living rooms,<br />

sleeping rooms, kitchens and halls. The<br />

electricity consumption has been proven<br />

to be reduced by up to 25% compared to<br />

buildings with no such temperature control.<br />

Modern heating cable solutions are thin<br />

with less mass to be heated. This makes<br />

modern heated floors very suitable for<br />

day/night temperature control.<br />

Positioning of the floor sensor<br />

Global expert in cables and cabling system<br />

<strong>Nexans</strong> Norway AS, Innspurten 9, Helsfyr, P.O.Box 6450 Etterstad, N-0605 Oslo, Norway<br />

Phone: + 47 22 88 61 00, Fax: + 47 22 88 61 01, Heatingcable.pc.no@nexans.com<br />

www.nexans.no, www.nexans.com/heating<br />

NEXANS NORWAY AS reserves the right to implement product changes without prior notice, as our products are being continuously developed.