SmartVent anesthesia ventilation<br />
<strong>SIMV</strong> <strong>and</strong> PSVPro <br />
<strong>Modes</strong> <strong>of</strong> <strong>Ventilation</strong><br />
Optimizing your patient’s ventilation<br />
Ventilating patients during anesthesia is going through a metamorphosis. With the use <strong>of</strong> laryngeal<br />
mask airways (LMAs) on the rise <strong>and</strong> the increasing interest in allowing patients to breathe spontaneously,<br />
anesthesia systems that support the patient’s natural breathing are in dem<strong>and</strong>. The 7900 SmartVent’s<br />
latest features, <strong>SIMV</strong> <strong>and</strong> PSVPro modes, exp<strong>and</strong>s the clinical capabilities <strong>of</strong> the Aestiva /5 anesthesia<br />
system to help meet the needs <strong>of</strong> your patients. With full patient range capability, an adjustable flow trigger,<br />
CPAP, PEEP <strong>and</strong> an apnea backup mode, the <strong>SIMV</strong> <strong>and</strong> PSVPro modes help simplify the work <strong>of</strong> caring for<br />
your spontaneously breathing patients.<br />
•<br />
Bundled together as an optional feature<br />
on the Aestiva/5 <strong>and</strong> the Aestiva/5 MRI<br />
anesthesia systems<br />
• Provides assured respiratory rates <strong>and</strong> tidal<br />
volumes to maintain a minimum minute ventilation<br />
•<br />
Flow triggering provides automatic synchronization<br />
<strong>of</strong> the breath<br />
•<br />
Pressure Support provided in combination with<br />
the <strong>SIMV</strong> mode<br />
•<br />
No need for additional hardware upgrades
SmartVent anesthesia ventilation<br />
VE O2<br />
7.0<br />
2.0 28 100<br />
25<br />
L/min %<br />
3.5<br />
VTE<br />
500<br />
mL<br />
700<br />
400<br />
ƒ<br />
8<br />
/min<br />
Pmax<br />
25<br />
cmH2O<br />
Pmean 12<br />
Ppl-60% 15<br />
Vol Alarms On<br />
Vent On <strong>SIMV</strong> Mode Circle<br />
VT Rate Tinspired Psupport PEEP<br />
625 4 1.5 5 5<br />
mL<br />
/min<br />
sec<br />
cmH20<br />
cmH20<br />
40<br />
30<br />
20<br />
10<br />
0<br />
0 2 4 6 8 10 12 14 16<br />
sec<br />
VE O2<br />
12.0<br />
3.0 30 100<br />
25<br />
L/min %<br />
10.0<br />
VTE<br />
820<br />
mL<br />
1000<br />
400<br />
ƒ<br />
15<br />
/min<br />
Pmax<br />
15<br />
cmH2O<br />
Pmean 7<br />
Vol Alarms On<br />
0 2 4 6 8 10 12 14 16<br />
sec<br />
Vent On PSVPro Mode Circle<br />
Pinspired Rate Tinspired Psupport PEEP<br />
20 10 1.5 10 5<br />
cmH20<br />
/min<br />
sec<br />
cmH20<br />
cmH20<br />
40<br />
30<br />
20<br />
10<br />
0<br />
<strong>SIMV</strong> - Synchronized Intermittent M<strong>and</strong>atory <strong>Ventilation</strong><br />
• SmartVent tidal volume compensation system works in<br />
m<strong>and</strong>atory breaths<br />
• Adjustable trigger window allows fine-tuning to the<br />
patient’s breathing pattern<br />
• Respiratory rate adjustable from 2 – 60 bpm<br />
• Provides assured rate <strong>and</strong> tidal volume for minimum<br />
minute ventilation<br />
• Automatic synchronization with m<strong>and</strong>atory breaths<br />
• Designed to improve synchronization <strong>of</strong> breaths which<br />
can decrease patient’s tendency to fight the ventilator<br />
Broad range <strong>of</strong> patients<br />
ARDS<br />
COPD<br />
Multiple<br />
trauma<br />
Spontaneous Breathing<br />
Datex-Ohmeda Division • Instrumentarium Corp.<br />
P.O. Box 900, FIN-00031 Datex-Ohmeda, Finl<strong>and</strong><br />
Tel. +358 10 39411 • Fax +358 9 146 3310<br />
www.datex-ohmeda.com<br />
Pulmonary infections<br />
Congenital<br />
defects<br />
Premature infants<br />
<strong>and</strong> neonates<br />
SmartVent addresses the complexity <strong>of</strong> patient needs found in your clinical<br />
environment.<br />
PSVPro – Pressure Supported <strong>Ventilation</strong><br />
• Helps to decrease the patient’s work <strong>of</strong> breathing<br />
• Able to be used with most LMAs<br />
• Automatic apnea backup mode uses an <strong>SIMV</strong>-PC + PSV mode to<br />
maintain a minimum minute ventilation in the event the patient<br />
stops spontaneously breathing.<br />
• CPAP capability<br />
• Adjustable inspiration termination allows fine-tuning to the patient’s<br />
breathing pattern<br />
• Supports spontaneous breaths<br />
• Uses a decelerating flow pattern<br />
• Sustains or enhances the patient’s tidal volume <strong>and</strong> helps to assist<br />
in maintaining normal etCO 2<br />