29.01.2015 Views

GC Columns

GC Columns

GC Columns

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>GC</strong> COLUMNS | APPLICATION-SPECIFIC COLUMNS<br />

Clinical, Forensic & Toxicology<br />

restek innovation!<br />

Baseline resolution in less than 3 minutes.<br />

similar phases<br />

DB-ALC1, DB-ALC2<br />

Blood Alcohol Analysis<br />

Rtx®-BAC1/Rtx®-BAC2<br />

• Application-specific columns for blood alcohol analysis—achieve baseline resolution<br />

in less than 3 minutes. Also excellent for abused inhalant anesthetics, γ-hydroxybutyrate<br />

(GHB)/γ-butyrolactone (GBL), glycols, and common industrial solvents.<br />

• Rtx®-BAC2 confirmation column provides four elution order changes under the<br />

same conditions.<br />

• Stable to 260 °C.<br />

These columns separate to baseline all blood alcohol compounds in blood, breath, or<br />

urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases<br />

productivity by eliminating the need for oven cycling. Confirmation is easily achieved<br />

with this tandem set because there are four elution order changes between the two<br />

columns.<br />

free<br />

literature<br />

<strong>GC</strong> Analysis of Blood<br />

Alcohols<br />

Download your free<br />

copy from<br />

www.restek.com<br />

lit. cat.# 59598A<br />

Rtx®-BAC1 <strong>Columns</strong> (fused silica)<br />

(proprietary Crossbond® phase)<br />

ID df temp. limits 30-Meter<br />

0.32mm 1.80µm -20 to 240/260°C 18003<br />

0.53mm 3.00µm -20 to 240/260°C 18001<br />

Rapid, reliable blood alcohol testing, using Rtx®-BAC 1 and Rtx®-BAC2<br />

columns.<br />

Rtx®-BAC1 30 m, 0.53 mm ID, 3.0 μm (cat.# 18001)<br />

2<br />

5<br />

6<br />

Rtx®-BAC2 <strong>Columns</strong> (fused silica)<br />

(proprietary Crossbond® phase)<br />

ID df temp. limits 30-Meter<br />

0.32mm 1.20µm -20 to 240/260°C 18002<br />

0.53mm 2.00µm -20 to 240/260°C 18000<br />

Blood alcohol<br />

analysis in less than<br />

3 minutes!<br />

4<br />

Get More!<br />

Clinical, Forensic<br />

& Toxicology<br />

Solutions Online<br />

www.restek.com/CFT<br />

1<br />

3<br />

min. 1 2 3<br />

Rtx®-BAC2 30 m, 0.53 mm ID, 2.0 μm (cat.# 18000)<br />

2<br />

5<br />

6<br />

1. methanol<br />

2. acetaldehyde<br />

3. ethanol<br />

4. isopropanol<br />

5. acetone<br />

6. n-propanol<br />

Inj.:<br />

1.0mL headspace sample<br />

of a blood alcohol mix<br />

Sample conc.: 0.1% per compound<br />

Oven temp.: 40°C<br />

Inj./det. temp.: 200°C<br />

Carrier gas: helium<br />

Linear velocity: 80cm/sec. set @ 40°C<br />

FID sensitivity: 1.28 x 10 -10 AFS<br />

4<br />

1<br />

3<br />

min. 1 2 3<br />

<strong>GC</strong>_PH00239<br />

82 www.restek.com<br />

Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar 2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!