PRODUCT DATA SHEET<br />

<strong>CB20</strong> - OPENBUS TM<br />

<strong>CONTROL</strong> <strong>BOX</strong><br />

Features & Options:<br />

• 4 channel version (8 Amps)<br />

• 5 channel version (8 Amps)<br />

• 6 channel version (8 Amps)<br />

• Mains voltage 230V 50/60Hz version - also<br />

available as Low Power version<br />

• Mains voltage 120V 60Hz version - also available<br />

as Low Power version<br />

• Mains voltage 100V 50/60Hz version - also<br />

available as Low Power version<br />

• Service data is logged on every channel/actuator<br />

• Standard software, with many functionalities<br />

• Battery capacity 1.2 AH, 24 V<br />

• Protection class: IPX4, IPX6 (Cannot be used for<br />

Washable systems)<br />

• The CP together with the BA can be mounted<br />

separately from the CU with use of the<br />

mounting bracket<br />

• Multiple position feedback possible on all<br />

channels (Reed, Hall and potentiometer)<br />

• Connection of up to 12 Handsets / Attendant<br />

controls, (depending on current consumption)<br />

• Power management<br />

• Colour: grey<br />

• Locking mechanism is included in CU20<br />

• Customised software<br />

• Low power version<br />

Usage:<br />

• Compatible with LA27C, LA31, LA34, LA44, BL1<br />

and BL4/BB3 configured for <strong>CB20</strong><br />

• Duty cycle: 10% ˜ max. 2 min. continuous use<br />

followed by 18 min. not in use<br />

• Ambient temperature +5˚ to + 40˚C<br />

• Standard <strong>CB20</strong> is UL60601 and EN60601-1<br />

approved with the following products:<br />

LA23, LA27, LA31, LA34, BL1, ACC, ACK, ACO,<br />

HB4X, HB5x, HB7x, HB8x, HD8x and HL8x<br />

<strong>CB20</strong> is the platform for the future with a unique<br />

safety concept, logging of service data and it is possible<br />

to connect a variety of accessories to the control<br />

box.<br />

<strong>CB20</strong> consists of 3 modules:<br />

• CP20 = Control Power<br />

• CU20 = Control Unit<br />

• BA20 = Battery<br />

The modularity makes it easy to update the product<br />

with new technology and enables easier servicing.<br />

The product is herewith prepared for future demands<br />

in the area of advanced actuator solutions.


CP20<br />

Ordering example:<br />

CP20<br />

0 0 0 0 0 A 0 1 0 0 9<br />

Cables:<br />

IP protection:<br />

Mains Voltage:<br />

9 = No mains cable encl. (must be ordered separately)<br />

0 = IPX4<br />

6 = IPX6<br />

0 = 230 V 50 Hz<br />

1 = 120 V 60 Hz<br />

2 = 100 V 50/60 Hz<br />

Colour: 1 = Grey, RAL 7035<br />

Class:<br />

Battery:<br />

Output cable :<br />

0 = Class 1, with earth connection<br />

1 = Class 2, without earth connection<br />

A = For use with 1.2 Ah Lead Acid batteries<br />

0 = For mounting on CP only<br />

Not used:<br />

Transformer:<br />

Type:<br />

0 = 200W supply toroidal (standard)<br />

1 = 270W supply toroidal (increased power), only for<br />

230V and 120V versions<br />

0 = Std.<br />

G = Low Power<br />

NB: IPX6 - cannot be used for Washable systems<br />

Features & Options:<br />

• Mains voltage 100,120, 230V AC 50/60Hz<br />

• 200 W toroidal transformer<br />

• Class 1 (with earth)<br />

• Colour: grey<br />

• IP Protection class IPX4<br />

• IP Protection class IPX6 (Cannot be used for<br />

Washable systems)<br />

• Extension cable and mounting plate for use when<br />

CP20 and BA20 are placed separately from the CU20<br />

(must be ordered separately)<br />

• Low Power<br />

Precautions:<br />

Please note mains cable must be ordered seperately.<br />

Dimensions:


CU20<br />

Ordering example:<br />

CU20<br />

0 0 0 0 0 0 1 1 0 0 4<br />

Channels:<br />

IP protection:<br />

4 = No. of channels<br />

5 = No. of channels<br />

6 = No. of channels<br />

0 = IPX4<br />

6 = IPX6<br />

Port 7 options:<br />

0 = None<br />

1 = for future use<br />

Colour: 1 = Grey, RAL 7035<br />

Board type:<br />

Software:<br />

Type:<br />

1 = Standard (8 Amp.)<br />

2 = with EEPROM, for use with COBO20<br />

If CU20 software is specified with memory or fixed positions<br />

(Special software)<br />

00000 = No software programmed<br />

1xxxx = LINAK software number/configuration<br />

77xxx/60xxx = Customer specific software<br />

0 = Std.<br />

G = Low Power<br />

NB: IPX6 - cannot be used for Washable systems<br />

Features & Options:<br />

• 4, 5 or 6 channels<br />

• 8 Amp. current cut-off on each individual channel<br />

• Colour: grey<br />

• IP Protection class IPX4<br />

• Configurable software<br />

• IP Protection class IPX6 (Cannot be used for<br />

Washable systems))<br />

• Customised software<br />

• Low Power<br />

Blind plug for IN ports: Order no.: 0821008 (must be ordered separately)<br />

Dimensions:


BA20<br />

Ordering example:<br />

BA20<br />

1<br />

6 - 0 2 0 0 - 0 0 0<br />

Not used:<br />

Not used:<br />

Not used:<br />

Not used:<br />

Type:<br />

Not used:<br />

0 = Not used<br />

0 = Not used<br />

0 = Not used<br />

- = Not used<br />

0200 = 1.2Ah Lead Acid battery<br />

- = Not used<br />

IP protection:<br />

6 = IPX6<br />

Colour:<br />

1 = RAL 7035<br />

Type:<br />

BA20<br />

NB: IPX6 - cannot be used for Washable systems<br />

Features:<br />

• 1.2 Ah Lead Acid battery<br />

• Colour: grey<br />

• IP Protection class IPX6 (Cannot be used for Washable systems)<br />

Dimensions BA20:


<strong>CB20</strong> (complete) dimensions:


Compatibility<br />

The introduction of <strong>CB20</strong> and OpenBus communication has made it necessary to make changes to Actuators,<br />

Handsets and Attendant Controls. In order to make them compatible with OpenBus control boxes.<br />

The following products are compatible with <strong>CB20</strong><br />

Product: Type: Cable:<br />

LA27 Option position: 0 (Standard)<br />

Must be CABLE A<br />

Option position: B (Hall)<br />

Must be CABLE A<br />

LA31<br />

LA34<br />

LA44<br />

Option: 0 (Standard)<br />

Option: H (Hall)<br />

Positioning: 0 (No)<br />

Positioning: P (Potentiometer)<br />

Positioning: H (Hall)<br />

Positioning: 0 (No)<br />

Positioning: P (Potentiometer)<br />

Positioning: H (Hall)<br />

Must be CABLE P<br />

Must be CABLE K<br />

Must be CABLE U<br />

Must be CABLE U<br />

Must be CABLE U<br />

BB3 Option: 2 (Reed <strong>CB20</strong>)<br />

BL4<br />

Option: 2 (Reed <strong>CB20</strong>)<br />

HB40 Functionality: V Must be CABLE B<br />

HB50 Functionality: V Must be CABLE B<br />

HB70 Functionality: V Must be CABLE B<br />

HL70 Functionality: V Must be CABLE B<br />

HB80 Functionality: V Must be cable ID:<br />

61, 62 or 63<br />

ACC All types<br />

ACK All types<br />

MJB All types<br />

DJB Type: 001<br />

(This functionality makes it possible to connect not OpenBus<br />

HB’s and FS’s to a OpenBus system)<br />

Must be CABLE 4<br />

FS1 All types but only connected through DJB 001<br />

FS2 All types but only connected through DJB 001<br />

LA31, LA34 and LA44 actuators are fitted with the exchangeable cable socket.<br />

<strong>CB20</strong> is at the present not compatible with ”buffer” type actuators.


Products for mounting CP20 and BA20 apart from CU20:<br />

Item no.: Product description Colour<br />

0951016 Mounting plate RAL7035<br />

0964014 Extension cable between CP-CU RAL7035<br />

Mounting plate dimensions:<br />

ACC and MJB cables:<br />

Item no.: Type: Colour: Material: Plug: Length:<br />

0277054-1250 Straight RAL7035 PVC Modular jack – modular jack 1250<br />

0277054-2500 Straight RAL7035 PVC Modular jack – modular jack 2500<br />

0277054-300 Straight RAL7035 PVC Modular jack – modular jack 300<br />

0964110-500 Straight RAL7035 PVC Modular Jack 500<br />

0964110-600 Straight RAL7035 PVC Modular Jack 600<br />

0964110-800 Straight RAL7035 PVC Modular Jack 800<br />

0964233 Straight RAL7035 PVC Modular jack – modular jack 650<br />

Actuator connector cables:<br />

Item no.: Wires: Type: Colour: Material: Plug: Length:<br />

0964003-300 6 Straight RAL7035 PVC Minifit - Minifit 300<br />

0964003-500 6 Straight RAL7035 PVC Minifit - Minifit 500<br />

0964003-1000 6 Straight RAL7035 PVC Minifit - Minifit 1000<br />

0964003-1250 6 Straight RAL7035 PVC Minifit - Minifit 1250<br />

0964003-2500 6 Straight RAL7035 PVC Minifit - Minifit 2500<br />

0964008-200 4 Coiled RAL7035 PVC Minifit - Minifit 200<br />

0964008-400 4 Coiled RAL7035 PVC Minifit - Minifit 400<br />

0964424-0300 6 Straight* RAL7035 PVC Minifit - Minifit 300<br />

0964424-0500 6 Straight* RAL7035 PVC Minifit - Minifit 500<br />

0964424-1250 6 Straight* RAL7035 PVC Minifit - Minifit 1250<br />

0964424-2500 6 Straight* RAL7035 PVC Minifit - Minifit 2500<br />

*18 AWG motor wires<br />

Please be aware:<br />

<strong>CB20</strong> is delivered in 3 separate units. The units are not assembled at LINAK A/S


Copyright © LINAK 2012.05 . MA M9-02-214-D . Chapter 6.12<br />

Terms of use<br />

The user is responsible for determining the suitability of LINAK products for specific application.<br />

LINAK takes great care in providing accurate and up-to-date information on its products.<br />

However, due to continuous development in order to improve its products, LINAK products are<br />

subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot<br />

guarantee the correct and actual status of said information on its products.<br />

While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as<br />

mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves<br />

the right to discontinue the sale of any product displayed on its website or listed in its catalogues<br />

or other written material drawn up by LINAK.<br />

All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof,<br />

please contact LINAK.<br />

FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER’S MANUALS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!