You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
PRODUCT DATA SHEET<br />
<strong>CB20</strong> - OPENBUS TM<br />
<strong>CONTROL</strong> <strong>BOX</strong><br />
Features & Options:<br />
• 4 channel version (8 Amps)<br />
• 5 channel version (8 Amps)<br />
• 6 channel version (8 Amps)<br />
• Mains voltage 230V 50/60Hz version - also<br />
available as Low Power version<br />
• Mains voltage 120V 60Hz version - also available<br />
as Low Power version<br />
• Mains voltage 100V 50/60Hz version - also<br />
available as Low Power version<br />
• Service data is logged on every channel/actuator<br />
• Standard software, with many functionalities<br />
• Battery capacity 1.2 AH, 24 V<br />
• Protection class: IPX4, IPX6 (Cannot be used for<br />
Washable systems)<br />
• The CP together with the BA can be mounted<br />
separately from the CU with use of the<br />
mounting bracket<br />
• Multiple position feedback possible on all<br />
channels (Reed, Hall and potentiometer)<br />
• Connection of up to 12 Handsets / Attendant<br />
controls, (depending on current consumption)<br />
• Power management<br />
• Colour: grey<br />
• Locking mechanism is included in CU20<br />
• Customised software<br />
• Low power version<br />
Usage:<br />
• Compatible with LA27C, LA31, LA34, LA44, BL1<br />
and BL4/BB3 configured for <strong>CB20</strong><br />
• Duty cycle: 10% ˜ max. 2 min. continuous use<br />
followed by 18 min. not in use<br />
• Ambient temperature +5˚ to + 40˚C<br />
• Standard <strong>CB20</strong> is UL60601 and EN60601-1<br />
approved with the following products:<br />
LA23, LA27, LA31, LA34, BL1, ACC, ACK, ACO,<br />
HB4X, HB5x, HB7x, HB8x, HD8x and HL8x<br />
<strong>CB20</strong> is the platform for the future with a unique<br />
safety concept, logging of service data and it is possible<br />
to connect a variety of accessories to the control<br />
box.<br />
<strong>CB20</strong> consists of 3 modules:<br />
• CP20 = Control Power<br />
• CU20 = Control Unit<br />
• BA20 = Battery<br />
The modularity makes it easy to update the product<br />
with new technology and enables easier servicing.<br />
The product is herewith prepared for future demands<br />
in the area of advanced actuator solutions.
CP20<br />
Ordering example:<br />
CP20<br />
0 0 0 0 0 A 0 1 0 0 9<br />
Cables:<br />
IP protection:<br />
Mains Voltage:<br />
9 = No mains cable encl. (must be ordered separately)<br />
0 = IPX4<br />
6 = IPX6<br />
0 = 230 V 50 Hz<br />
1 = 120 V 60 Hz<br />
2 = 100 V 50/60 Hz<br />
Colour: 1 = Grey, RAL 7035<br />
Class:<br />
Battery:<br />
Output cable :<br />
0 = Class 1, with earth connection<br />
1 = Class 2, without earth connection<br />
A = For use with 1.2 Ah Lead Acid batteries<br />
0 = For mounting on CP only<br />
Not used:<br />
Transformer:<br />
Type:<br />
0 = 200W supply toroidal (standard)<br />
1 = 270W supply toroidal (increased power), only for<br />
230V and 120V versions<br />
0 = Std.<br />
G = Low Power<br />
NB: IPX6 - cannot be used for Washable systems<br />
Features & Options:<br />
• Mains voltage 100,120, 230V AC 50/60Hz<br />
• 200 W toroidal transformer<br />
• Class 1 (with earth)<br />
• Colour: grey<br />
• IP Protection class IPX4<br />
• IP Protection class IPX6 (Cannot be used for<br />
Washable systems)<br />
• Extension cable and mounting plate for use when<br />
CP20 and BA20 are placed separately from the CU20<br />
(must be ordered separately)<br />
• Low Power<br />
Precautions:<br />
Please note mains cable must be ordered seperately.<br />
Dimensions:
CU20<br />
Ordering example:<br />
CU20<br />
0 0 0 0 0 0 1 1 0 0 4<br />
Channels:<br />
IP protection:<br />
4 = No. of channels<br />
5 = No. of channels<br />
6 = No. of channels<br />
0 = IPX4<br />
6 = IPX6<br />
Port 7 options:<br />
0 = None<br />
1 = for future use<br />
Colour: 1 = Grey, RAL 7035<br />
Board type:<br />
Software:<br />
Type:<br />
1 = Standard (8 Amp.)<br />
2 = with EEPROM, for use with COBO20<br />
If CU20 software is specified with memory or fixed positions<br />
(Special software)<br />
00000 = No software programmed<br />
1xxxx = LINAK software number/configuration<br />
77xxx/60xxx = Customer specific software<br />
0 = Std.<br />
G = Low Power<br />
NB: IPX6 - cannot be used for Washable systems<br />
Features & Options:<br />
• 4, 5 or 6 channels<br />
• 8 Amp. current cut-off on each individual channel<br />
• Colour: grey<br />
• IP Protection class IPX4<br />
• Configurable software<br />
• IP Protection class IPX6 (Cannot be used for<br />
Washable systems))<br />
• Customised software<br />
• Low Power<br />
Blind plug for IN ports: Order no.: 0821008 (must be ordered separately)<br />
Dimensions:
BA20<br />
Ordering example:<br />
BA20<br />
1<br />
6 - 0 2 0 0 - 0 0 0<br />
Not used:<br />
Not used:<br />
Not used:<br />
Not used:<br />
Type:<br />
Not used:<br />
0 = Not used<br />
0 = Not used<br />
0 = Not used<br />
- = Not used<br />
0200 = 1.2Ah Lead Acid battery<br />
- = Not used<br />
IP protection:<br />
6 = IPX6<br />
Colour:<br />
1 = RAL 7035<br />
Type:<br />
BA20<br />
NB: IPX6 - cannot be used for Washable systems<br />
Features:<br />
• 1.2 Ah Lead Acid battery<br />
• Colour: grey<br />
• IP Protection class IPX6 (Cannot be used for Washable systems)<br />
Dimensions BA20:
<strong>CB20</strong> (complete) dimensions:
Compatibility<br />
The introduction of <strong>CB20</strong> and OpenBus communication has made it necessary to make changes to Actuators,<br />
Handsets and Attendant Controls. In order to make them compatible with OpenBus control boxes.<br />
The following products are compatible with <strong>CB20</strong><br />
Product: Type: Cable:<br />
LA27 Option position: 0 (Standard)<br />
Must be CABLE A<br />
Option position: B (Hall)<br />
Must be CABLE A<br />
LA31<br />
LA34<br />
LA44<br />
Option: 0 (Standard)<br />
Option: H (Hall)<br />
Positioning: 0 (No)<br />
Positioning: P (Potentiometer)<br />
Positioning: H (Hall)<br />
Positioning: 0 (No)<br />
Positioning: P (Potentiometer)<br />
Positioning: H (Hall)<br />
Must be CABLE P<br />
Must be CABLE K<br />
Must be CABLE U<br />
Must be CABLE U<br />
Must be CABLE U<br />
BB3 Option: 2 (Reed <strong>CB20</strong>)<br />
BL4<br />
Option: 2 (Reed <strong>CB20</strong>)<br />
HB40 Functionality: V Must be CABLE B<br />
HB50 Functionality: V Must be CABLE B<br />
HB70 Functionality: V Must be CABLE B<br />
HL70 Functionality: V Must be CABLE B<br />
HB80 Functionality: V Must be cable ID:<br />
61, 62 or 63<br />
ACC All types<br />
ACK All types<br />
MJB All types<br />
DJB Type: 001<br />
(This functionality makes it possible to connect not OpenBus<br />
HB’s and FS’s to a OpenBus system)<br />
Must be CABLE 4<br />
FS1 All types but only connected through DJB 001<br />
FS2 All types but only connected through DJB 001<br />
LA31, LA34 and LA44 actuators are fitted with the exchangeable cable socket.<br />
<strong>CB20</strong> is at the present not compatible with ”buffer” type actuators.
Products for mounting CP20 and BA20 apart from CU20:<br />
Item no.: Product description Colour<br />
0951016 Mounting plate RAL7035<br />
0964014 Extension cable between CP-CU RAL7035<br />
Mounting plate dimensions:<br />
ACC and MJB cables:<br />
Item no.: Type: Colour: Material: Plug: Length:<br />
0277054-1250 Straight RAL7035 PVC Modular jack – modular jack 1250<br />
0277054-2500 Straight RAL7035 PVC Modular jack – modular jack 2500<br />
0277054-300 Straight RAL7035 PVC Modular jack – modular jack 300<br />
0964110-500 Straight RAL7035 PVC Modular Jack 500<br />
0964110-600 Straight RAL7035 PVC Modular Jack 600<br />
0964110-800 Straight RAL7035 PVC Modular Jack 800<br />
0964233 Straight RAL7035 PVC Modular jack – modular jack 650<br />
Actuator connector cables:<br />
Item no.: Wires: Type: Colour: Material: Plug: Length:<br />
0964003-300 6 Straight RAL7035 PVC Minifit - Minifit 300<br />
0964003-500 6 Straight RAL7035 PVC Minifit - Minifit 500<br />
0964003-1000 6 Straight RAL7035 PVC Minifit - Minifit 1000<br />
0964003-1250 6 Straight RAL7035 PVC Minifit - Minifit 1250<br />
0964003-2500 6 Straight RAL7035 PVC Minifit - Minifit 2500<br />
0964008-200 4 Coiled RAL7035 PVC Minifit - Minifit 200<br />
0964008-400 4 Coiled RAL7035 PVC Minifit - Minifit 400<br />
0964424-0300 6 Straight* RAL7035 PVC Minifit - Minifit 300<br />
0964424-0500 6 Straight* RAL7035 PVC Minifit - Minifit 500<br />
0964424-1250 6 Straight* RAL7035 PVC Minifit - Minifit 1250<br />
0964424-2500 6 Straight* RAL7035 PVC Minifit - Minifit 2500<br />
*18 AWG motor wires<br />
Please be aware:<br />
<strong>CB20</strong> is delivered in 3 separate units. The units are not assembled at LINAK A/S
Copyright © LINAK 2012.05 . MA M9-02-214-D . Chapter 6.12<br />
Terms of use<br />
The user is responsible for determining the suitability of LINAK products for specific application.<br />
LINAK takes great care in providing accurate and up-to-date information on its products.<br />
However, due to continuous development in order to improve its products, LINAK products are<br />
subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot<br />
guarantee the correct and actual status of said information on its products.<br />
While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as<br />
mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves<br />
the right to discontinue the sale of any product displayed on its website or listed in its catalogues<br />
or other written material drawn up by LINAK.<br />
All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof,<br />
please contact LINAK.<br />
FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER’S MANUALS