R410A<br />

<strong>VRF</strong> <strong>inverter</strong> <strong>multi</strong>-<strong>system</strong> <strong>Air</strong>-<strong>Conditioners</strong><br />

50Hz<br />

12KX01E-A-0


R410A<br />

History of Technologies<br />

more efficient , more sophisticated<br />

KX2 KX4 KX6<br />

(8~12HP)<br />

2


Line Up<br />

Contents<br />

Introduction 4~17<br />

Outdoor units 18~49<br />

Indoor units<br />

Control <strong>system</strong>s<br />

50~85<br />

86~93<br />

High Head series 94~97<br />

Refresh KX outdoor units<br />

98 . 99<br />

Further information 100~103<br />

3


R410A<br />

Product Line Up<br />

<br />

from 11.2kW up to 136.0kW(24models)<br />

Single use (1 Outdoor unit)<br />

Capacity<br />

Model Code : kW<br />

BTU / h<br />

kcal / h<br />

4HP<br />

11.2<br />

38,200<br />

9,630<br />

5HP<br />

14<br />

47,800<br />

12,040<br />

6HP<br />

15.5<br />

52,900<br />

13,330<br />

8HP<br />

22.4<br />

76,400<br />

19,260<br />

10HP<br />

28<br />

95,500<br />

24,080<br />

12HP<br />

33.5<br />

114,300<br />

28,810<br />

14HP<br />

40.0<br />

136,500<br />

34,400<br />

16HP<br />

45.0<br />

153,600<br />

38,700<br />

18HP<br />

50.4<br />

172,000<br />

43,340<br />

20HP<br />

56.0<br />

191,100<br />

48,160<br />

22HP<br />

61.5<br />

209,900<br />

52,890<br />

24HP<br />

68.0<br />

232,000<br />

58,480<br />

Capacity<br />

Model Index : kW<br />

BTU / h<br />

kcal / h<br />

26HP<br />

73.5<br />

250,800<br />

63,210<br />

28HP<br />

80.0<br />

273,000<br />

68,800<br />

30HP<br />

85.0<br />

290,100<br />

73,100<br />

Combination use (2 Outdoor units)<br />

32HP<br />

90.0<br />

307,100<br />

77,400<br />

34HP<br />

96.0<br />

327,600<br />

82,560<br />

36HP<br />

101.0<br />

344,700<br />

86,860<br />

38HP<br />

106.5<br />

363,400<br />

91,590<br />

40HP<br />

113.0<br />

385,600<br />

97,180<br />

42HP<br />

118.0<br />

402,700<br />

101,480<br />

44HP<br />

123.5<br />

421,400<br />

106,210<br />

46HP<br />

130.0<br />

443,600<br />

111,800<br />

48HP<br />

136.0<br />

464,100<br />

116,960<br />

4HP 5HP 6HP<br />

FDC112KXEN6<br />

FDC112KXES6<br />

FDC140KXEN6<br />

FDC140KXES6<br />

FDC155KXEN6<br />

FDC155KXES6<br />

1-phase 220-240V<br />

3-phase 380-415V<br />

8HP 10HP 12HP<br />

FDC224KXE6 FDC280KXE6 FDC335KXE6<br />

12HP 14HP 16HP 18HP<br />

FDC335KXE6-K FDC400KXE6 FDC450KXE6 FDC504KXE6<br />

20HP 20HP 22HP<br />

24HP<br />

FDC560KXE6 FDC560KXE6-K FDC615KXE6 FDC680KXE6<br />

26HP 28HP 30HP 32HP 34HP 36HP<br />

FDC735KXE6 FDC800KXE6 FDC850KXE6 FDC900KXE6 FDC960KXE6 FDC1010KXE6<br />

12+14 14+14 14+16 16+16 16+18 18+18<br />

FDC335KXE6-K<br />

FDC400KXE6<br />

FDC400KXE6<br />

FDC400KXE6<br />

FDC400KXE6<br />

FDC450KXE6<br />

FDC450KXE6<br />

FDC450KXE6<br />

FDC450KXE6<br />

FDC504KXE6<br />

FDC504KXE6<br />

FDC504KXE6<br />

38HP 40HP 42HP 44HP 46HP 48HP<br />

FDC1065KXE6 FDC1130KXE6 FDC1180KXE6 FDC1235KXE6 FDC1300KXE6 FDC1360KXE6<br />

18+20 20+20 20+22 22+22 22+24 24+24<br />

FDC504KXE6<br />

FDC560KXE6<br />

FDC560KXE6<br />

FDC560KXE6<br />

FDC560KXE6-K<br />

FDC615KXE6<br />

FDC615KXE6<br />

FDC615KXE6<br />

FDC335KXE6-K & FDC560KXE6-K are only used for combining with other models.<br />

FDC615KXE6<br />

FDC680KXE6<br />

FDC680KXE6<br />

FDC680KXE6<br />

4


Wide variety of 17 types 89 models<br />

A range of 17 types of exposed or concealed<br />

indoor units, in wide capacities, 89 indoor models.<br />

The best selection of indoor units for<br />

many kinds of rooms and preference can be<br />

available from our full lineup.<br />

Indoor units lineup<br />

Type<br />

Capacity<br />

Model Code : kW<br />

0.5HP 0.8HP 1HP 1.25HP 1.6HP 2HP 2.5HP 3.2HP 4HP 5HP 6HP 8HP 10HP<br />

15 22 28 36 45 56 71 90 112 140 160 224 280<br />

4way<br />

FDT<br />

4way Compact<br />

(600 x 600)<br />

FDTC<br />

Ceiling<br />

Cassette<br />

2way<br />

FDTW<br />

1way Compact<br />

FDTQ<br />

1way<br />

FDTS<br />

High<br />

Static Pressure<br />

FDU<br />

Duct<br />

Connected<br />

Low/Middle<br />

Static Pressure<br />

Low Static<br />

Pressure<br />

(thin)<br />

Compact &<br />

Flexible<br />

FDUM<br />

FDUT<br />

FDUH<br />

Wall Mounted<br />

FDK<br />

Ceiling Suspended<br />

FDE<br />

2way<br />

FDFW<br />

Floor<br />

Standing<br />

with casing<br />

FDFL<br />

without casing<br />

FDFU<br />

OA Processing unit<br />

FDU-F<br />

Type <strong>Air</strong> flow M 3 /h 250 350 500 800 850 1000 1300 1800<br />

Fresh <strong>Air</strong> Ventilation and<br />

Heat Exchange unit<br />

SAF<br />

Fresh <strong>Air</strong> DX Assembly<br />

SAF-DX<br />

5


R410A<br />

eco touch REMOTE CONTROL<br />

Advanced touch screen panel with full dot Liquid Crystal display<br />

User friendly<br />

•LCD panel with light tap operation<br />

introduced as the industry's first<br />

•Simple interface with only three buttons<br />

High level of visibility<br />

•Big LCD with 3.8 inch full dot display<br />

•Back light function<br />

•Multi language display (9 languages)<br />

NEW<br />

RC-EX1A<br />

Run / Stop<br />

High power operation<br />

The highest capacity operation<br />

(Max 15 minutes)<br />

•Increasing compressor speed<br />

•Increasing air flow volume<br />

Energy-saving operation<br />

•Changes set temperature.<br />

At 28ºC in cooling mode and 22ºC<br />

in heating mode, 25ºC in auto mode.<br />

•Operation correction by<br />

outdoor temperature<br />

Simple setting by tapping button only<br />

6


1. Basic operation<br />

All settings done by tapping touch screen panel<br />

Operation mode<br />

Operation mode setting screen<br />

Cooling<br />

Dry<br />

Fan<br />

Heating<br />

Auto<br />

Setting temperature screen<br />

The desired operation mode can<br />

be selected by simply tapping<br />

this button.<br />

2. Main functions<br />

Saving energy<br />

Sleep timer<br />

Peak cut timer<br />

Automatic temerature set back<br />

Weekly timer<br />

Set ON/OFF timer by hour<br />

Set ON/OFF timer by clock<br />

Convenience<br />

Comfort<br />

Individual flap control<br />

High power operation<br />

External ventilation ON/OFF<br />

Warming up operation<br />

Automatic fan speed<br />

Temperature increment setting<br />

by 0.5ºC<br />

Service<br />

LCD contrast setting<br />

Error code display<br />

Back light setting<br />

Operation data display<br />

Filter sign<br />

Next service date display<br />

Control sound<br />

Contact company display<br />

Outdoor silent mode<br />

USB connection (mini-B)<br />

Summer time setting<br />

Home leave mode<br />

Indoor & outdoor temperature display<br />

Heating standby display<br />

Defrosting operation display<br />

Auto cooling/heating display<br />

ºC/ºF display<br />

Administrator settings<br />

Room name setting<br />

You can select the temperture as<br />

desired by tapping button.<br />

eco touch Remote control RC-EX1A Series<br />

Utility Software<br />

By connecting this <strong>system</strong> to the eco touch<br />

Remote Control, the eco touch Remote<br />

Control can be operated from PC.<br />

Outdoor unit<br />

eco touch<br />

Remote Control<br />

Indoor unit<br />

USB<br />

eco touch Remote Control<br />

RC-EX1A Utility Software<br />

7


R410A<br />

1. High Efficiency (KX6)<br />

The industry's highest COP levels<br />

We have cleared the class A standard, the highest energy saving level, with our high COP (Coefficient Of Performance).<br />

EER in Cooling<br />

COP<br />

4.5<br />

4.0<br />

3.5<br />

4.00<br />

3.36 3.29<br />

A<br />

CLASS<br />

4.00<br />

3.46 3.41 3.55 3.47 3.42 3.34<br />

3.2<br />

COP in Heating<br />

COP<br />

4.5<br />

4.0<br />

3.5<br />

A<br />

CLASS<br />

4.33<br />

4.15<br />

3.71 3.72<br />

3.84<br />

3.71<br />

3.84<br />

3.82<br />

3.74 3.75<br />

3.6<br />

3.0<br />

3.0<br />

2.5<br />

4 5 6 8 10 12 14<br />

COP = Capacity[kW] / Power Consumption[kW]<br />

*<br />

16 18 20 HP<br />

* COP across the KX6 range ensures reduced running costs and reduced environmental impact. 1FAN<br />

2.5<br />

4 5 6<br />

8<br />

10<br />

12 14<br />

16 18 20 HP<br />

(ISO-T1 conditions)<br />

2. Compact Design<br />

4~6HP(KX6)<br />

Volume<br />

35% less<br />

Weight<br />

32% less<br />

1FAN<br />

8~12HP(KX6)<br />

KX4<br />

H1300 x W970 x D370mm<br />

125kg / 0.47m 3<br />

• Transportation Becomes much easier<br />

• Easier to hide behind the fence<br />

(Harmonic Appearance)<br />

Volume<br />

47% less<br />

Weight<br />

10% less<br />

KX6<br />

H845 x W970 x D370mm<br />

85kg / 0.30m 3<br />

(FDC112/140/155KXEN6)<br />

2FAN<br />

KX4<br />

H1690 x W1350 x D720mm<br />

245kg / 0.97m 3<br />

• Transportation Becomes much easier<br />

KX6<br />

H1675 x W1080 x D480mm<br />

221kg / 0.52m 3 (FDC224KXE6)<br />

8


High efficiency and compact design are realized<br />

applying the various advanced functions<br />

4~6HP(KX6)<br />

New Twin Rotary<br />

Compressor<br />

Compact High Efficient<br />

Heat Exchanger<br />

New Inverter Control<br />

Vector Inverter Control <strong>system</strong><br />

Compact high efficiency Heat<br />

Exchanger<br />

• Optimizing relationship of the air flow velocity &<br />

fin pattern<br />

• Improvement of air distribution Maximizing<br />

efficiency of heat exchanger<br />

Heat Exchanger<br />

DC Fan Motor<br />

Compact & High efficiency<br />

KX4<br />

KX6<br />

Optimum New Refrigerant System Control<br />

8~12HP(KX6)<br />

New DC Fan motor<br />

Compact & High efficiency<br />

New Inverter Control<br />

Compact & Vector Inverter<br />

Control <strong>system</strong><br />

Downsized accumulator<br />

Receiver in fan section<br />

3D-Scroll Compressor<br />

(12HP)<br />

14~48HP(KX6)<br />

DC Fan Motor<br />

Tetrahedral structure of<br />

Heat Exchanger<br />

Expansion of Heat Exchanger<br />

Double tube<br />

New Inverter Control<br />

3D-Scroll Compressor<br />

(22,24HP)<br />

9


R410A<br />

3D Scroll Compressor<br />

Unit start up speed in heating mode drastically improved for lower outdoor temperature operation.<br />

Present scroll<br />

3D scroll<br />

Same height<br />

Fixed scroll<br />

Lower at the<br />

inside<br />

Higher at the<br />

outside<br />

2-Dimension compression<br />

Orbital scroll<br />

3-Dimension compression<br />

High strength due to<br />

the lower teeth inside<br />

High Efficiency<br />

Downsizing<br />

High Endurance<br />

3D scroll compressor has the different height scroll at the<br />

outside and the inside.<br />

A high compression ratio is improved by compressing the<br />

refrigerant both radially and axially.<br />

3-Dimension Compression has been realized with a much<br />

higher efficiency even if compression ratio is high.<br />

The strength of the scroll is improved<br />

by reducing the height of the inner<br />

wrap, which receives a heavy load.<br />

3D compressors are applied for 12HP, 20HP, 22HP & 24HP.<br />

New Inverter Control (Vector control)<br />

New Inverter Control has applied new advanced technology of Vector<br />

control and has realized high efficiency.<br />

• Smooth operation from low speed to high speed<br />

• Smooth Sine Voltage Wave form are attained<br />

• Energy efficiency is further improved in low speed range<br />

Compact Integrated PCB<br />

• Control Box size reduction<br />

• PCB size reduced by 50 %<br />

Control PCB: Single-sided board Double-sided board<br />

Inverter PCB: Power transistor size reduction<br />

• New Superlink <strong>system</strong> control<br />

• New Design method applied<br />

Optimum Refrigerant System Control<br />

We have improved refrigeration circuit from our long experience<br />

and have realized following Optimum Refrigerant System Control.<br />

• Optimum heat exchanger refrigerant distribution<br />

• Advanced refrigerant liquid return protection control <strong>system</strong><br />

• High speed <strong>system</strong> control by new Superlink <strong>system</strong><br />

• Use of larger diameter for suction piping and discharge piping<br />

and redesigned of double tube<br />

KX4<br />

Control PCB<br />

KX6<br />

DC Fan Motor<br />

Employment of DC fan motor has enabled to realize an excellent<br />

efficiency of approximate 60% higher than previous models.<br />

Rotor(Squirrel Cage made of conductor)<br />

Stator (coil) Rotor(made of permanent magnet)<br />

Stator (coil)<br />

Long-chorded 3 propeller fan with serration<br />

Fan blade design adapted from MHI's aerospace division - with<br />

serrated edges that deliver increased air volume with less<br />

power input.<br />

Serration<br />

10


3. Design Flexibility<br />

Increased indoor unit connection capacity<br />

Capacity connection<br />

KX6 series(4~34HP) can connect indoor unit capacity up to<br />

150~200% from 130% of previous models.<br />

If the connection capacity of indoor units is more than 100%,<br />

capacity of each indoor unit may be affected by connection<br />

capacity ratio.<br />

HP KX4,KXR4<br />

5~12 130%<br />

14,16 130%<br />

18~34 130%<br />

36~48 130%<br />

HP<br />

4~12<br />

14,16<br />

18~34<br />

36~48<br />

KX6<br />

150%<br />

200%<br />

160%<br />

130%<br />

HP<br />

8~16<br />

18~34<br />

36~48<br />

KXR6<br />

200%<br />

160%<br />

130%<br />

KX6 14,16HP<br />

KXR6 8~16HP<br />

• In case that capacity connection is more than 130%, additional charge of<br />

refrigerant is required on site.<br />

• In case of 8-34HP of KX6/KXR6 <strong>system</strong>, if one or more indoor units of<br />

FDK, FDFL,FDFU and/or FDFW series are connected to the <strong>system</strong>, the<br />

total connecting capacity of indoor units should not exceed 130%.<br />

KX4<br />

130% capacity connection<br />

KX6<br />

200% capacity connection<br />

More connectable indoor units<br />

KX6 enable more connectable indoor units (per kW), compared with former model KX4.<br />

80<br />

75<br />

Number of connectable indoor unit<br />

70<br />

65<br />

60<br />

55<br />

50<br />

KX6<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

KX4<br />

15<br />

10<br />

5<br />

0<br />

4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 HP<br />

Control Systems<br />

KX6 series offer wide variation of control <strong>system</strong> and provide the best solution.<br />

[KX6, KXR6 Control <strong>system</strong> units with "New" SUPERLINK- ]<br />

Classification<br />

Individual controller<br />

Center Console<br />

Wired<br />

Wireless<br />

Push buttons<br />

Touch screen<br />

Type<br />

PC windows interface units<br />

BMS interface<br />

units<br />

BACnet<br />

Lonworks<br />

Model<br />

RC-E5<br />

RC-EX1A<br />

RCN-T-36W-E etc.<br />

SC-SL1N-E<br />

SC-SL2NA-E<br />

SC-SL3NA-AE<br />

SC-SL3NA-BE<br />

SC-WGWNA-A<br />

SC-WGWNA-B<br />

SC-BGWNA-A<br />

SC-BGWNA-B<br />

SC-LGWNA-A<br />

Connectable Indoor units<br />

(Maximum)<br />

1<br />

1<br />

1<br />

16<br />

64<br />

128<br />

128<br />

128(64x2)<br />

128(64x2)<br />

128(64x2)<br />

128(64x2)<br />

96(48x2)<br />

Electric power<br />

calculation<br />

11


1350mm 1350mm 1350mm<br />

R410A<br />

Long Pipe Length<br />

Piping length has extended max height difference between indoor<br />

units from 4m to 18m and enables us to put indoor unit on extra<br />

three floors.<br />

8~12HP(KX6)<br />

As a result of the adoption of thinner refrigerant piping and refrigerant<br />

volume reductions, the industry's longest 160 m actual piping length or<br />

1000m total piping length is realized.<br />

14~48HP(KX6), 8~48HP(KXR6)<br />

Total length: 510m<br />

To the<br />

first branch:<br />

max 130m<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 40m 90m*<br />

Outdoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

* The difference between the longest and the shortest indoor<br />

unit piping from the first branch must be within 40m.<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

4m 18m<br />

Furthest<br />

indoor unit:<br />

160m<br />

Total length:<br />

510 1000m<br />

To the<br />

first branch:<br />

max 130m<br />

From the first branch<br />

to the furthest<br />

indoor unit: 40m 90m *<br />

Outdoor unit<br />

Max: 10m<br />

Max: 5m<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

* The difference between the longest and the shortest indoor<br />

unit piping from the first branch must be within 40m.<br />

Max: 0.4m<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

15m 18m<br />

Furthest<br />

indoor unit:<br />

160m<br />

(1)Divide up the refrigerant <strong>system</strong> into independent refrigeration circuit <strong>system</strong>s in case required additional refrigerant on site is 50kg or more for<br />

14~24HP and 100kg or more for 26~48HP.<br />

(2)In case indoor unit connection capacity is 130% or more or total piping length is 510m or more, additional charge of refrigerant and oil on site<br />

is required. Refer to our Installation Manual for details.<br />

Easy Transportation & Installation<br />

Due to realization of significant reduction in size and foot print which is one of<br />

the smallest in the industry, transportation in an elevator made for six persons<br />

(Width:1400mm, Depth:850, Open area:800mm) is possible, eliminating cost<br />

of a crane and reducing labor.<br />

1,400<br />

8~12HP (KX6)<br />

H1,675 x W1,080 x D480<br />

Transportation in an<br />

elevator made for six<br />

persons<br />

850<br />

Easy<br />

transportation<br />

800<br />

KX6(14~48HP) is portable and the uniform reduced footprint<br />

allows neat, continuous installation.<br />

12


Wide Range of Operation<br />

KX6,KXR6 series permits a <strong>system</strong> design considering a heating range operation under a low temperature condition up to -20ºC from -15ºC of<br />

previous model and a cooling range operation under -15ºC from -5ºC of that.<br />

-20ºC<br />

Heating<br />

KX6<br />

+15.5ºC<br />

-15ºC<br />

-15ºC<br />

KX4<br />

Cooling<br />

KX6<br />

+43ºC<br />

-5ºC<br />

KX4<br />

-20 -10 0 10 20 30 40<br />

For the capacities under low temperature conditions, refer to technical manual.<br />

50<br />

Remote control for all indoor units<br />

Applying nonpolar 2-core in remote control line, it is very<br />

convenient for installation including renewal case.<br />

KX4<br />

3-core<br />

KX6<br />

2-core<br />

Max length of electrical wiring<br />

The wiring must be a 2-core shielded cable size 0.75mm 2 to<br />

1.25mm 2 .<br />

The max length of 2-core can be 1500m from 1000m of<br />

previous models.<br />

KX4<br />

1000m<br />

KX6<br />

1500m<br />

4. Serviceability<br />

Easy Service<br />

Quick and easy access to service parts by separation of<br />

compartments.<br />

Blower<br />

compartment<br />

Check Operation (8~48HP)<br />

Closing of Service valve, crossing connection of refrigerant<br />

piping and electrical wiring, proper operation of EEV (Electrical<br />

Expansion Valve) can be checked automatically in cooling<br />

operation. This check operation can be done at 0~43ºC outdoor<br />

temperature and 10~32ºC indoor temperature by use of<br />

outdoor unit dip switch. The check should be done in one<br />

refrigerant <strong>system</strong>. It takes 15~30 minutes and avoids frequent<br />

failure by preventing careless mistakes during installation.<br />

dip switch<br />

Mechanical<br />

compartment<br />

13


R410A<br />

Monitoring Function<br />

KX6 series includes new feature to assist with servicing and trouble shooting.<br />

Various data can be monitored through 3-digit or 6-digit display on the outdoor unit PCB.<br />

Detailed fault diagnosis and operation history memory via<br />

7-segment display.<br />

Equipped with RS232C<br />

for connection directly to<br />

your PC monitoring and<br />

service tasks made<br />

simple with our service<br />

software (“Mente PC”).<br />

all KX6, KXR6 series<br />

4~6HP<br />

8~48HP<br />

3 Layer Construction<br />

(KX6 , KXR6 )<br />

Thanks to improvement of<br />

control box structure from<br />

4 to 3 layer construction<br />

and by use of hinged lays,<br />

service and maintenance<br />

has been made much easier<br />

for <strong>inverter</strong> components.<br />

Back-up Operation <br />

In, 2-compressor module, in the event of the compressor<br />

failure, the <strong>system</strong> will keep operating with good compressor.<br />

In combined module, in the event that one unit has a failure,<br />

the <strong>system</strong> will keep operating with another unit.<br />

Should compressor be damaged, compressor replacement<br />

should be done as soon as possible. However as emergency<br />

measure for a limited time, in 2 compressor module, the<br />

<strong>system</strong> can be kept operating with the good compressor. In<br />

combined module, the <strong>system</strong> can be kept operating with the<br />

other unit.<br />

Keeping<br />

operation<br />

Compressor<br />

failed<br />

Reduced Refrigerant Volume<br />

To use the new refrigerant<br />

R410A, KX6 series have<br />

adopted thinner diameter<br />

refrigerant pipes, which<br />

will help reduce piping<br />

work cost.<br />

KX6<br />

R410A<br />

9.52 22.22<br />

Liquid<br />

piping<br />

ex.10HP<br />

Gas piping<br />

Outdoor unit<br />

KX6<br />

HP<br />

Liquid piping Gas piping<br />

4<br />

5<br />

ø15.88<br />

6 ø9.52<br />

8<br />

ø19.05<br />

10<br />

ø22.22<br />

12<br />

ø25.4[ø28.58]<br />

14<br />

16<br />

18 ø12.7<br />

20<br />

ø28.58<br />

22<br />

24<br />

26<br />

28<br />

30<br />

ø31.8[ø34.92]<br />

ø15.88<br />

32<br />

34<br />

36<br />

38<br />

40<br />

42<br />

ø38.1[ø34.92]<br />

ø19.05<br />

44<br />

46<br />

48<br />

[ ]: Pipe sizes applicable to European<br />

installations are shown in parentheses.<br />

mm ø9.52 ø12.7 ø15.88 ø19.05 ø22.22 ø25.4 ø28.58 ø31.8 ø34.92 ø38.1 ø44.5 ø50.8<br />

inch<br />

3/8"<br />

1/2"<br />

5/8"<br />

3/4"<br />

7/8"<br />

1"<br />

1 1/8 "<br />

1 1/4 "<br />

1 3/8 "<br />

1 1/2 "<br />

1 3/4 "<br />

2"<br />

Blue Fin<br />

Inverter<br />

Due to application of blue coated fins for the heat exchanger of<br />

new outdoor unit, corrosion resistance has been improved<br />

compared to current models.<br />

14


heat pump <strong>system</strong>s<br />

KX6 heat pump <strong>system</strong>s operate with 2 inter-connecting pipes,<br />

thus commonly referred to as a '2-pipe <strong>system</strong>'.<br />

These <strong>system</strong>s provide either a heating or cooling operation to all<br />

indoor units and are suitable for a wide range of applications from<br />

an individual apartment (with "Micro KX", 1/phase <strong>system</strong>) to an<br />

entire <strong>multi</strong> storey building, especially where there are significant<br />

open plan areas to be controlled.<br />

The range starts with a 11.2kW cooling capacity, up to the largest<br />

capacity single outdoor unit in the industry (24hp) with 68.0kW<br />

cooling capacity. Outdoor units can also be “twinned” providing up<br />

to 48HP/136.0kW on a single <strong>system</strong>.<br />

The KX6 range has a total piping length of 1000m (14HP+) and the<br />

furthest indoor unit can be connected up to 160m (8HP+) from the<br />

outdoor unit.<br />

Fixed Cooling mode/fixed heating mode (summer/winter switch):<br />

It is possible to fix the operational mode of the <strong>system</strong> (either cooling or heating) using a switch (SW3-7) on the outdoor<br />

unit PC board - this enables the building user to decide the operation of the <strong>system</strong> (e.g. cooling only in summer/heating<br />

only in winter), to avoid unnecessary energy wastage. It is also possible to wire the control switch to a remote location<br />

(inside the building) to a control room, or even linked to an ambient thermostat.<br />

15


R410A<br />

DUCT CONNECTED -Middle Static pressure-<br />

FDUM<br />

NEW<br />

Automatic external static pressure (E.S.P.) control<br />

Duct design was simplified.<br />

Using DC motor, the most optimum air flow volume can be achieved by<br />

this automatic control.<br />

Indoor unit will recognize external static pressure by itself automatically<br />

and keep rated air flow volume.<br />

Duct<br />

New<br />

FDUM<br />

Duct<br />

Longer Duct<br />

Ceiling<br />

Keep the same<br />

air flow volume<br />

case1<br />

case2<br />

Setting No.<br />

No.1<br />

No.2<br />

No.3<br />

No.4<br />

No.5<br />

No.6<br />

No.7<br />

No.8<br />

No.9<br />

No.10<br />

E.S.P. button<br />

RC-E5<br />

E.S.P.<br />

10Pa<br />

20Pa<br />

30Pa<br />

40Pa<br />

50Pa<br />

60Pa<br />

70Pa<br />

80Pa<br />

90Pa<br />

100Pa<br />

External static pressure (E.S.P.) can be set by<br />

E.S.P. button.<br />

Ceiling Cassette -2 way-<br />

FDTW<br />

NEW<br />

Individual flap control <strong>system</strong><br />

According to room temperature conditions, four directions air flow can be<br />

controlled individually by flap control <strong>system</strong>.<br />

Due to optimization of outlet design of air flow our new advanced technology,<br />

sufficient air flow is secured and long reach of air flow is achieved.<br />

Wireless remote control<br />

For wireless remote control<br />

simply insert the infrared<br />

receiver kit on a corner of<br />

the panel.<br />

3<br />

RCN-TW-E<br />

Flap control <strong>system</strong><br />

1 2<br />

4<br />

The flap can swing within the range of<br />

upper and lower flap position selected<br />

with wired remote control.<br />

(this <strong>system</strong> is applied for FDT, FDTC,<br />

FDTS, FDK, FDEN, and FDFW type also)<br />

Selected<br />

upper position<br />

Max swing<br />

range<br />

Selected<br />

lower position<br />

* Wireless remote control and RCH-E3 is not applicable to the lndvidual flap<br />

control <strong>system</strong> and the Flap control <strong>system</strong>.<br />

16


DUCT CONNECTED (thin) -Low Static pressure-<br />

FDUT<br />

NEW<br />

Compact design <br />

Height: 220 200mm<br />

20mm less!!<br />

Depth: 520 500mm<br />

Lower noise <br />

1m<br />

1m<br />

Unit<br />

2m<br />

1m<br />

1.5m<br />

[dB(A)]<br />

30<br />

20<br />

10<br />

29<br />

1dB(A)<br />

Down<br />

28<br />

24<br />

Current<br />

New<br />

2dB(A)<br />

Down<br />

22<br />

Current Model<br />

Serviceability<br />

Larger outlet for connecting duct<br />

L700 x 70mm L860 x 99 (45/56)<br />

New Model<br />

Measured based on JIS B 8616<br />

0<br />

[dB(A)]<br />

40<br />

30<br />

Hi<br />

5dB(A)<br />

Down<br />

Fan speed<br />

Lo<br />

Current<br />

New<br />

4dB(A)<br />

Down<br />

Access to control<br />

20<br />

10<br />

37<br />

32<br />

30<br />

26<br />

Access to control Access to fan motor Access to fan motor<br />

0<br />

Hi<br />

Fan speed<br />

Lo<br />

Current Model<br />

New Model<br />

Ceiling Cassette -1 way-<br />

FDTS<br />

FDTS<br />

NEW<br />

Wireless remote control<br />

For wireless remote control simply attach an additional panel with infrared receiver<br />

on the right side of the main decorative panel.<br />

Individual flap control <strong>system</strong><br />

Two directions of air flow can be controlled individually by flap<br />

control <strong>system</strong>.<br />

RCN-TS-E<br />

17


R410A<br />

Outdoor units<br />

Heat pump <strong>system</strong>s 4, 5, 6hp (11.2kW~15.5kW)<br />

Model No.<br />

FDC112KXEN6<br />

FDC140KXEN6<br />

FDC155KXEN6<br />

FDC112KXES6<br />

FDC140KXES6<br />

FDC155KXES6<br />

Nominal Cooling Capacity<br />

11.2kW (1phase)<br />

14.0kW (1phase)<br />

15.5kW (1phase)<br />

11.2kW (3phase)<br />

14.0kW (3phase)<br />

15.5kW (3phase)<br />

•The KX6 heat pump 2-pipe <strong>system</strong>s offer high performance <strong>VRF</strong> for<br />

applications that require either cooling only or heating only, ideal<br />

for open plan areas.<br />

•Connect up to 8 indoor units/up to 150% capacity.<br />

•High efficiency with COP (in cooling) up to 4.0.<br />

•KX6 employs DC <strong>inverter</strong> compressors ONLY.<br />

•Industry leading total piping length up to 100m and a maximum pipe<br />

run of 70m.<br />

Total length: 100m<br />

Range of operation<br />

Outdoor unit<br />

Indoor unit<br />

Indoor unit<br />

Height difference<br />

30m(outdoor unit above)<br />

15m(outdoor unit below)<br />

Max height<br />

difference between<br />

indoor units: 15m<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

+43ºC<br />

Cooling<br />

+15.5ºC<br />

Heating<br />

-10<br />

Furthest<br />

indoor unit: 70m<br />

-20<br />

-15ºC<br />

-20ºC<br />

* The total length of ø9.52mm(3/8") liquid piping must be 50m or less<br />

Specifications<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

mm(in)<br />

%<br />

FDC112KXEN6 FDC140KXEN6 FDC155KXEN6 FDC112KXES6 FDC140KXES6 FDC155KXES6<br />

4HP<br />

5HP<br />

6HP<br />

4HP<br />

5HP<br />

6HP<br />

1 Phase 220-240V, 50Hz<br />

3 Phase 380-415V, 50Hz<br />

11.2<br />

12.5<br />

2.80<br />

2.89<br />

13.5-12.4<br />

14.1-12.9<br />

52/54<br />

6<br />

14.0<br />

16.0<br />

4.17<br />

4.31<br />

20.6-18.9<br />

21.5-19.7<br />

85<br />

53/55<br />

8<br />

15.5<br />

16.3<br />

4.71<br />

4.38<br />

23.3-21.3<br />

21.9-20.1<br />

5<br />

845x970x370<br />

11.2<br />

12.5<br />

2.80<br />

2.89<br />

4.5-4.1<br />

4.7-4.3<br />

5.0<br />

53/56<br />

52/54<br />

ø9.52(3/8")<br />

ø15.88(5/8")<br />

80~150<br />

8<br />

6<br />

14.0<br />

16.0<br />

4.17<br />

4.31<br />

6.9-6.3<br />

7.2-6.6<br />

87<br />

53/55<br />

8<br />

15.5<br />

16.3<br />

4.71<br />

4.38<br />

7.8-7.1<br />

7.3-6.7<br />

53/56<br />

8<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

18


Refrigerant piping<br />

Outdoor unit (HP) 4 5 6<br />

Gas pipe Furthest indoor unit ø15.88<br />

Liquid pipe =


R410A<br />

Outdoor units<br />

Heat pump <strong>system</strong>s 8, 10, 12hp (22.4kW~33.5kW)<br />

Model No.<br />

FDC224KXE6<br />

FDC280KXE6<br />

FDC335KXE6<br />

Nominal Cooling Capacity<br />

22.4kW<br />

28.0kW<br />

33.5kW<br />

•The KX6 heat pump 2-pipe <strong>system</strong>s offer high performance <strong>VRF</strong> for<br />

applications that require either cooling only or heating only, ideal<br />

for open plan areas.<br />

•Connect up to 22 indoor units/up to 150% capacity.<br />

•High efficiency with COP (in cooling) up to 4.0.<br />

•KX6 employs DC <strong>inverter</strong> compressors ONLY.<br />

•Industry leading total piping length up to 510m and a maximum pipe<br />

run of 160m.<br />

Total length: 510m<br />

To the<br />

first branch:<br />

max 130m<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 90m*<br />

Outdoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

18m<br />

Furthest<br />

indoor unit: 160m<br />

Range of operation<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

-20<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

-20ºC<br />

+15.5ºC<br />

Heating<br />

* The difference between the longest and the shortest indoor unit piping<br />

from the first branch must be within 40m.<br />

Specifications<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

mm(in)<br />

%<br />

FDC224KXE6<br />

8HP<br />

22.4<br />

25.0<br />

5.60<br />

6.03<br />

9.25-8.47<br />

9.85-9.02<br />

58/58<br />

ø19.05(3/4")<br />

15<br />

ø9.52(3/8")<br />

FDC280KXE6<br />

10HP<br />

3 Phase 380-415V, 50Hz<br />

28.0<br />

31.5<br />

5<br />

8.09<br />

8.21<br />

13.22-12.10<br />

13.41-12.28<br />

1675x1080x480<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

221<br />

11.5<br />

59/60<br />

ø22.22(7/8")<br />

50~150<br />

19<br />

FDC335KXE6<br />

12HP<br />

33.5<br />

37.5<br />

9.82<br />

10.12<br />

15.87-14.53<br />

16.36-14.98<br />

224<br />

61/61<br />

ø12.7(1/2")<br />

ø25.4(1") [ø28.58(1 1/8")]<br />

22<br />

20


Refrigerant piping<br />

Outdoor unit (HP) 8 10 12<br />

Branch pipes<br />

Header pipe<br />

Gas pipe Furthest indoor unit ø19.05 ø22.22 ø28.58<br />

Liquid pipe =


R410A<br />

Outdoor units<br />

Heat pump <strong>system</strong>s 14, 16hp (40.0kW~45.0kW)<br />

Model No.<br />

FDC400KXE6<br />

FDC450KXE6<br />

Nominal Cooling Capacity<br />

40.0kW<br />

45.0kW<br />

•The KX6 heat pump 2-pipe <strong>system</strong>s offer high performance <strong>VRF</strong> for<br />

applications that require either cooling only or heating only, ideal<br />

for open plan areas.<br />

•Connect up to 40 indoor units/up to 200% capacity.<br />

•High efficiency with COP (in cooling) up to 3.6.<br />

•KX6 employs DC <strong>inverter</strong> compressors ONLY.<br />

•Industry leading total piping length up to 1000m and a maximum<br />

pipe run of 160m.<br />

Uniform footprint of models (14,16hp)<br />

allows continuous side-by-side installation<br />

Total length: 1000m<br />

To the<br />

first branch:<br />

max 130m<br />

Outdoor unit<br />

Indoor unit<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

* 1 The difference between the longest and the shortest indoor unit piping<br />

furthest indoor<br />

Furthest<br />

unit: 90m* indoor unit: 160m<br />

* 2<br />

Max height<br />

Indoor unit difference<br />

between<br />

indoor units:<br />

From the first<br />

branch to the<br />

Indoor unit 18m<br />

from the first branch must be within 40m.<br />

* 2 Height difference up to 90m is possible with High Head series.<br />

Please refer to page 92.<br />

Range of operation<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

-20<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

-20ºC<br />

+15.5ºC<br />

Heating<br />

Specifications<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

mm(in)<br />

%<br />

FDC400KXE6<br />

14HP<br />

40.0<br />

45.0<br />

11.27<br />

11.73<br />

18.4-16.9<br />

19.6-17.9<br />

59.5/60<br />

ø25.4(1") [ø28.58(1 1/8")]<br />

36<br />

3 Phase 380-415V, 50Hz<br />

8<br />

1690x1350x720<br />

334<br />

11.5<br />

ø12.7(1/2")<br />

50~200<br />

FDC450KXE6<br />

16HP<br />

45.0<br />

50.0<br />

12.97<br />

13.10<br />

21.1-19.3<br />

21.7-19.9<br />

62.5/62.5<br />

ø28.58(1 1/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

40<br />

22


Dimensions<br />

All measurements in mm.<br />

Rear<br />

Dimensions of refrigerant<br />

pipe connection (plan)<br />

141<br />

234<br />

75<br />

142.5<br />

K<br />

B<br />

A<br />

95<br />

140.5<br />

19 726 19<br />

58.5 Anchor bolt positions for F, J<br />

647 58.5<br />

Anchor bolt positions for I<br />

250 850<br />

250<br />

175 1000 175<br />

J F I I F<br />

J I<br />

F<br />

I<br />

J<br />

F<br />

For dimensions of anchor bolt hole<br />

J<br />

<strong>Air</strong> intake<br />

74.5<br />

594 85<br />

232 101<br />

57<br />

85<br />

G<br />

232<br />

D(lower)<br />

185 H<br />

G<br />

148 352 158 342<br />

410 530 235<br />

80.5<br />

71<br />

C<br />

G<br />

140 120<br />

240<br />

296.7<br />

295 174<br />

22 720 22<br />

720<br />

126.2<br />

1350<br />

Drain pipe<br />

D (left)<br />

175<br />

80<br />

7-segment display<br />

inspection port<br />

Signal wire<br />

terminal block<br />

Terminal block<br />

for power cable<br />

connection<br />

1690<br />

682 797.8<br />

84<br />

6<br />

K<br />

B<br />

A<br />

C (front)<br />

166<br />

169<br />

211<br />

259<br />

291.6<br />

C (right)<br />

172<br />

Instruction plate<br />

104.9<br />

6<br />

86.1<br />

95<br />

D (front)<br />

90<br />

D (right)<br />

C (rear)<br />

172<br />

86.5<br />

220<br />

180<br />

550<br />

180<br />

214<br />

L<br />

44.7<br />

20<br />

Mark Item Installation example<br />

A Service valve connection (gas side)<br />

For refrigerant piping, please<br />

Dimensions 1<br />

2<br />

B Service valve connection (liquid line) refer to the unit specifications. L1 500 Open<br />

C Refrigerant pipe draw-out port<br />

ø88<br />

L2 10<br />

200<br />

D Power cable draw-in port<br />

ø50<br />

L3 100<br />

300<br />

F Anchor bolt hole<br />

M10 x 4 places<br />

L4 10<br />

Open<br />

G Drain hose hole<br />

ø45 x 3 places<br />

H1 1500<br />

–<br />

H Drain discharge port<br />

ø20 x 6 places<br />

H2 No restrictions No restrictions<br />

K * Oil-equalising pipe joint<br />

ø3/8” flare<br />

H3 1000 No restrictions<br />

L Sling holes for haulage or hoisting 180 x 44.7<br />

H4 No restrictions –<br />

*14, 16HP models only<br />

Wall<br />

height H2<br />

Intake<br />

L2<br />

Intake<br />

Service<br />

space<br />

L3<br />

L1<br />

Intake<br />

Installation space<br />

2m overhead clearance required<br />

Wall<br />

height H3<br />

L4<br />

Intake<br />

Wall height H4<br />

Wall height H1<br />

Notes:<br />

(1) The unit must be fixed with anchor bolts.<br />

(2) Leave a 2m or larger space above the unit.<br />

(3) The unit name plate is attached on the lower right corner of<br />

the front panel.<br />

(4) The ports for refrigerant pipe and power cable penetrations<br />

are covered with half-blanks. Please cut off a half-blank with<br />

nippers in using these ports.<br />

(5) Use a ø88 port for refrigerant pipe connection.<br />

(6) Anchor holes marked “L J” (four holes for M10) are for a<br />

renewal installation.<br />

(7) The oil-equalising pipe K should be used when outdoor units<br />

are used in combination. (For 14,16Hp only)<br />

When more than one unit is installed<br />

Wall height<br />

H2<br />

Wall height<br />

H3<br />

L2 L5 L6 L4<br />

L3<br />

Wall height<br />

H2<br />

L1 (Unit front side)<br />

Wall height<br />

H4<br />

Installation example<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

L5<br />

L6<br />

H1<br />

A<br />

500<br />

10<br />

100<br />

10<br />

0<br />

0<br />

1500<br />

B<br />

Open<br />

200<br />

300<br />

Open<br />

400<br />

400<br />

No restrictions<br />

H2<br />

No restrictions<br />

No restrictions<br />

H3<br />

1000<br />

No restrictions<br />

H4<br />

No restrictions<br />

No restrictions<br />

23


R410A<br />

Outdoor units<br />

Heat pump <strong>system</strong>s 18, 20, 22, 24hp (50.4kW~68.0kW)<br />

Model No.<br />

FDC504KXE6<br />

FDC560KXE6<br />

FDC615KXE6<br />

FDC680KXE6<br />

Nominal Cooling Capacity<br />

50.4kW<br />

56.0kW<br />

61.5kW<br />

68.0kW<br />

•The KX6 heat pump 2-pipe <strong>system</strong>s offer high performance <strong>VRF</strong> for<br />

applications that require either cooling only or heating only, ideal<br />

for open plan areas.<br />

•Connect up to 49 indoor units/up to 160% capacity.<br />

•High efficiency with COP (in cooling) up to 3.4.<br />

•KX6 employs DC <strong>inverter</strong> compressors ONLY.<br />

•Industry leading total piping length up to 1000m and a maximum<br />

pipe run of 160m.<br />

Total length: 1000m<br />

To the<br />

first branch:<br />

max 130m<br />

Specifications<br />

Outdoor unit<br />

Indoor unit<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

* 1 The difference between the longest and the shortest indoor unit piping<br />

furthest indoor<br />

Furthest<br />

unit: 90m* indoor unit: 160m<br />

* 2<br />

Max height<br />

Indoor unit difference<br />

between<br />

indoor units:<br />

From the first<br />

branch to the<br />

Indoor unit 18m<br />

from the first branch must be within 40m.<br />

* 2 Height difference up to 90m is possible with High Head series.<br />

Please refer to page 92.<br />

Range of operation<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

-20<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

Uniform footprint of all models (from<br />

8hp~24hp) allows continuous sideby-side<br />

installation<br />

-20ºC<br />

+15.5ºC<br />

Heating<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

mm(in)<br />

%<br />

FDC504KXE6 FDC560KXE6 FDC615KXE6 FDC680KXE6<br />

18HP<br />

20HP<br />

22HP<br />

24HP<br />

3 Phase 380-415V, 50Hz<br />

50.4<br />

56.5<br />

14.73<br />

15.12<br />

24.1-22.0<br />

25.2-23.1<br />

61.5/62.0<br />

36<br />

56.0<br />

63.0<br />

16.79<br />

16.79<br />

27.4-25.1<br />

28.0-25.7<br />

8<br />

61.5<br />

69.0<br />

20.37<br />

18.48<br />

33.1-30.3<br />

30.7-28.1<br />

2048x1350x720<br />

356 375<br />

11.5<br />

63.0/63.5<br />

64.5/64.0<br />

ø12.7(1/2")<br />

ø28.58(1 1/8")<br />

50~160<br />

40<br />

44<br />

68.0<br />

73.0<br />

24.98<br />

19.08<br />

40.3-36.9<br />

31.6-29.0<br />

65.0/65.0<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

49<br />

24


Dimensions<br />

All measurements in mm.<br />

Rear<br />

Dimensions of refrigerant<br />

pipe connection (plan)<br />

141<br />

234<br />

A<br />

75<br />

142.5<br />

K<br />

B<br />

95<br />

140.5<br />

19 726 19<br />

58.5 Anchor bolt positions for F, J<br />

647 58.5<br />

Anchor bolt positions for I<br />

250 850<br />

250<br />

175 1000 175<br />

J F I I F<br />

J I<br />

F<br />

I<br />

J<br />

F<br />

For dimensions of anchor bolt hole<br />

J<br />

<strong>Air</strong> intake<br />

74.5<br />

594 85<br />

232 101<br />

57<br />

85<br />

G<br />

232<br />

D(lower)<br />

185 H<br />

G<br />

148 352 158 342<br />

410 530 235<br />

80.5<br />

71<br />

C<br />

G<br />

140 120<br />

240<br />

296.7<br />

295 174<br />

22 720 22<br />

720<br />

126.2<br />

1350<br />

Drain pipe<br />

D (left)<br />

80<br />

175<br />

7-segment display<br />

inspection port<br />

Signal wire<br />

terminal block<br />

Terminal block<br />

for power cable<br />

connection<br />

2048<br />

682 1155.8<br />

84<br />

6<br />

K<br />

B<br />

A<br />

C (front)<br />

166<br />

169<br />

211<br />

259<br />

291.6<br />

C (right)<br />

172<br />

Instruction plate<br />

104.9<br />

6<br />

86.1<br />

95<br />

D (front)<br />

90<br />

D (right)<br />

C (rear)<br />

172<br />

86.5<br />

220<br />

180<br />

550<br />

180<br />

214<br />

L<br />

44.7<br />

20<br />

Mark Item Installation example<br />

A<br />

B<br />

C<br />

D<br />

F<br />

G<br />

H<br />

K<br />

L<br />

Service valve connection (gas side)<br />

Service valve connection (liquid line)<br />

Refrigerant pipe draw-out port<br />

Power cable draw-in port<br />

Anchor bolt hole<br />

Drain hose hole<br />

Drain discharge port<br />

Oil-equalising pipe joint<br />

Sling holes for haulage or hoisting<br />

For refrigerant piping, please<br />

refer to the unit specifications.<br />

ø100<br />

ø50<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø9.52 flare<br />

180 x 44.7<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

H1<br />

H2<br />

H3<br />

H4<br />

1<br />

500<br />

10<br />

100<br />

10<br />

1500<br />

No restrictions<br />

1000<br />

No restrictions<br />

2<br />

Open<br />

200<br />

300<br />

Open<br />

–<br />

No restrictions<br />

No restrictions<br />

–<br />

Wall<br />

height H2<br />

L2<br />

Intake<br />

Intake<br />

Service<br />

space<br />

L3<br />

L1<br />

Intake<br />

Installation space<br />

2m overhead clearance required<br />

L4<br />

Intake<br />

Wall<br />

height H3<br />

Wall height H4<br />

Wall height H1<br />

Notes:<br />

(1) The unit must be fixed with anchor bolts.<br />

(2) Leave a 2m or larger space above the unit.<br />

(3) The unit name plate is attached on the lower right corner of<br />

the front panel.<br />

(4) The ports for refrigerant pipe and power cable penetrations<br />

are covered with half-blanks. Please cut off a half-blank with<br />

nippers in using these ports.<br />

(5) Use a ø88 port for refrigerant pipe connection.<br />

(6) Anchor holes marked “L J” (four holes for M10) are for a<br />

renewal installation.<br />

(7) The oil-equalising pipe K should be used when outdoor units<br />

are used in combination.<br />

25


R410A<br />

Outdoor units<br />

Heat pump combination <strong>system</strong>s<br />

26, 28, 30, 32hp (73.5kW~90.0kW)<br />

Specifications<br />

Item<br />

Model No.<br />

FDC735KXE6 (FDC335-K+FDC400)<br />

FDC800KXE6 (FDC400x2)<br />

FDC850KXE6 (FDC400+FDC450)<br />

FDC900KXE6 (FDC450x2)<br />

Combination (FDC)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

mm(in)<br />

%<br />

Nominal Cooling Capacity<br />

73.5kW<br />

80.0kW<br />

85.0kW<br />

90.0kW<br />

•The KX6 heat pump 2-pipe <strong>system</strong>s offer high performance <strong>VRF</strong> for<br />

applications that require either cooling only or heating only, ideal<br />

for open plan areas.<br />

•Connect up to 65 indoor units/up to 160% capacity.<br />

•High efficiency with COP (in cooling) up to 3.6.<br />

•KX6 employs DC <strong>inverter</strong> compressors ONLY.<br />

•Industry leading total piping length up to 1000m and a maximum<br />

pipe run of 160m.<br />

Total length: 1000m<br />

Outdoor unit<br />

To the<br />

first branch:<br />

max 130m<br />

Model<br />

Indoor unit<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

* 1 The difference between the longest and the shortest indoor unit piping<br />

furthest indoor<br />

Furthest<br />

unit: 90m* indoor unit: 160m<br />

* 2<br />

Max height<br />

Indoor unit difference<br />

between<br />

indoor units:<br />

From the first<br />

branch to the<br />

Indoor unit 18m<br />

from the first branch must be within 40m.<br />

* 2 Height difference up to 90m is possible with High Head series.<br />

Please refer to page 92.<br />

Range of operation<br />

Uniform footprint of all<br />

models (from 8hp~24hp)<br />

allows continuous side-byside<br />

installation<br />

FDC735KXE6 FDC800KXE6 FDC850KXE6 FDC900KXE6<br />

335KXE6-K<br />

400KXE6<br />

26HP<br />

73.5<br />

82.5<br />

20.21<br />

20.66<br />

32.9-30.2<br />

34.4-31.4<br />

53<br />

400KXE6<br />

400KXE6<br />

28HP<br />

80.0<br />

90.0<br />

22.54<br />

23.46<br />

36.8-33.8<br />

39.2-35.8<br />

-10<br />

-20<br />

10<br />

0<br />

20<br />

30<br />

40<br />

3 Phase 380-415V, 50Hz<br />

16<br />

400KXE6<br />

450KXE6<br />

30HP<br />

85.0<br />

95.0<br />

24.24<br />

24.83<br />

39.5-36.2<br />

41.3-37.8<br />

1690x2700x720<br />

334x2<br />

11.5x2<br />

ø15.88(5/8")<br />

ø31.8(1 1/4") [ø34.92(1 3/8")]<br />

50~160<br />

58<br />

61<br />

50<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

-20ºC<br />

+15.5ºC<br />

Heating<br />

450KXE6<br />

450KXE6<br />

32HP<br />

90.0<br />

100.0<br />

25.94<br />

26.20<br />

42.2-38.6<br />

43.4-39.8<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

65<br />

26


Dimensions<br />

All measurements in mm.<br />

Rear<br />

Dimensions of refrigerant<br />

pipe connection (plan)<br />

141<br />

234<br />

75<br />

142.5<br />

K<br />

B<br />

A<br />

95<br />

140.5<br />

19 726 19<br />

58.5 Anchor bolt positions for F, J<br />

647 58.5<br />

Anchor bolt positions for I<br />

250 850<br />

250<br />

175 1000 175<br />

J F I I F<br />

J I<br />

F<br />

I<br />

J<br />

F<br />

J<br />

<strong>Air</strong> intake<br />

74.5<br />

594 85<br />

232 101<br />

57<br />

85<br />

G<br />

232<br />

D(lower)<br />

185 H<br />

G<br />

148 352 158 342<br />

410 530 235<br />

80.5<br />

71<br />

C<br />

G<br />

140 120<br />

240<br />

296.7<br />

295 174<br />

22 720 22<br />

720<br />

126.2<br />

1350<br />

Drain pipe<br />

D (left)<br />

175<br />

80<br />

7-segment display<br />

inspection port<br />

Signal wire<br />

terminal block<br />

Terminal block<br />

for power cable<br />

connection<br />

1690<br />

682 797.8<br />

84<br />

6<br />

K<br />

B<br />

A<br />

C (front)<br />

166<br />

169<br />

211<br />

259<br />

291.6<br />

C (right)<br />

172<br />

Instruction plate<br />

104.9<br />

6<br />

86.1<br />

95<br />

D (front)<br />

90<br />

D (right)<br />

C (rear)<br />

172<br />

86.5<br />

220<br />

180<br />

550<br />

180<br />

214<br />

L<br />

44.7<br />

20<br />

Mark<br />

A<br />

B<br />

C<br />

D<br />

F<br />

G<br />

H<br />

K<br />

L<br />

Item<br />

Service valve connection (gas side)<br />

Service valve connection (liquid line)<br />

Refrigerant pipe draw-out port<br />

Power cable draw-in port<br />

Anchor bolt hole<br />

Drain hose hole<br />

Drain discharge port<br />

Oil-equalising pipe joint<br />

Sling holes for haulage or hoisting<br />

For refrigerant piping, please<br />

refer to the unit specifications.<br />

ø88<br />

ø50<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø3/8" flare<br />

180 x 44.7<br />

Notes:<br />

(1) The unit must be fixed with anchor bolts.<br />

(2) Leave a 2m or larger space above the unit.<br />

(3) The unit name plate is attached on the lower right corner of<br />

the front panel.<br />

(4) The ports for refrigerant pipe and power cable penetrations<br />

are covered with half-blanks. Please cut off a half-blank with<br />

nippers in using these ports.<br />

(5) Use a ø88 port for refrigerant pipe connection.<br />

(6) Anchor holes marked “L J” (four holes for M10) are for a<br />

renewal installation.<br />

(7) The oil-equalising pipe K should be used when outdoor units<br />

are used in combination.<br />

27


R410A<br />

Outdoor units<br />

Heat pump combination <strong>system</strong>s<br />

34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW~136.0kW)<br />

Model No.<br />

FDC960KXE6 (FDC450+FDC504)<br />

FDC1010KXE6 (FDC504x2)<br />

FDC1065KXE6 (FDC504+FDC560)<br />

FDC1130KXE6 (FDC560x2)<br />

FDC1180KXE6 (FDC560-K+FDC615)<br />

FDC1235KXE6 (FDC615x2)<br />

FDC1300KXE6 (FDC615+FDC680)<br />

FDC1360KXE6 (FDC680x2)<br />

Specifications<br />

Item<br />

Combination (FDC)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

mm(in)<br />

%<br />

Nominal Cooling Capacity<br />

96.0kW<br />

101.0kW<br />

106.5kW<br />

113.0kW<br />

118.0kW<br />

123.5kW<br />

130.0kW<br />

136.0kW<br />

•The KX6 heat pump 2-pipe <strong>system</strong>s offer high performance <strong>VRF</strong> for applications that<br />

require either cooling only or heating only, ideal for open plan areas.<br />

•Connect up to 80 indoor units/up to 130% (960KXE6:160%) capacity.<br />

•High efficiency with COP (in cooling) up to 3.5.<br />

•KX6 employs DC <strong>inverter</strong> compressors ONLY.<br />

•Industry leading total piping length up to 1000m and a maximum pipe run of 160m.<br />

Total length: 1000m<br />

Outdoor unit<br />

Range of operation<br />

To the<br />

first branch:<br />

max 130m<br />

Indoor unit<br />

Model FDC960KXE6 FDC1010KXE6 FDC1065KXE6 FDC1130KXE6 FDC1180KXE6 FDC1235KXE6 FDC1300KXE6 FDC1360KXE6<br />

450KXE6 504KXE6 504KXE6 560KXE6 560KXE6-K 615KXE6 615KXE6 680KXE6<br />

504KXE6 504KXE6 560KXE6 560KXE6 615KXE6 615KXE6 680KXE6 680KXE6<br />

34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP<br />

3 Phase 380-415V, 50Hz<br />

96.0<br />

108.0<br />

27.70<br />

28.22<br />

45.2-41.3<br />

46.9-43.0<br />

334+356<br />

50~160<br />

69<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

* 1 The difference between the longest and the shortest indoor unit piping<br />

furthest indoor<br />

Furthest<br />

unit: 90m* indoor unit: 160m<br />

* 2<br />

Max height<br />

Indoor unit difference<br />

between<br />

indoor units:<br />

From the first<br />

branch to the<br />

Indoor unit 18m<br />

from the first branch must be within 40m.<br />

* 2 Height difference up to 90m is possible with High Head series.<br />

Please refer to page 92.<br />

ø15.88(5/8")<br />

101.0<br />

113.0<br />

29.46<br />

30.24<br />

48.2-44.0<br />

50.4-46.2<br />

59<br />

106.5<br />

119.5<br />

31.52<br />

31.91<br />

51.5-47.1<br />

53.2-48.8<br />

356x2<br />

62<br />

-10<br />

-20<br />

113.0<br />

127.0<br />

33.58<br />

33.58<br />

54.8-50.2<br />

56.0-51.4<br />

10<br />

0<br />

20<br />

30<br />

40<br />

16<br />

50<br />

118.0<br />

132.0<br />

37.16<br />

35.27<br />

60.5-55.4<br />

58.7-53.8<br />

2048x2700x720<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

-20ºC<br />

123.5<br />

138.0<br />

40.74<br />

36.96<br />

66.2-60.6<br />

61.4-56.2<br />

11.5x2<br />

ø19.05(3/4")<br />

ø34.92(1 3/8")<br />

50~130<br />

66<br />

69<br />

72<br />

+15.5ºC<br />

Heating<br />

130.0<br />

142.0<br />

45.35<br />

37.56<br />

73.4-67.2<br />

62.3-57.1<br />

76<br />

136.0<br />

146.0<br />

49.96<br />

38.16<br />

80.6-73.8<br />

63.2-58.0<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

375x2<br />

80<br />

28


Dimensions<br />

All measurements in mm.<br />

Rear<br />

Dimensions of refrigerant<br />

pipe connection (plan)<br />

141<br />

234<br />

75<br />

142.5<br />

K<br />

B<br />

A<br />

95<br />

140.5<br />

19 726 19<br />

58.5 Anchor bolt positions for F, J<br />

647 58.5<br />

Anchor bolt positions for I<br />

250 850<br />

250<br />

175 1000 175<br />

J F I I F<br />

J I<br />

F<br />

I<br />

J<br />

F<br />

J<br />

<strong>Air</strong> intake<br />

74.5<br />

594 85<br />

232 101<br />

57<br />

85<br />

G<br />

232<br />

D(lower)<br />

185 H<br />

G<br />

148 352 158 342<br />

410 530 235<br />

80.5<br />

71<br />

C<br />

G<br />

140 120<br />

240<br />

296.7<br />

295 174<br />

22 720 22<br />

720<br />

126.2<br />

1350<br />

Drain pipe<br />

D (left)<br />

80<br />

175<br />

7-segment display<br />

inspection port<br />

Signal wire<br />

terminal block<br />

Terminal block<br />

for power cable<br />

connection<br />

2048<br />

682 1155.8<br />

84<br />

6<br />

K<br />

B<br />

A<br />

C (front)<br />

166<br />

169<br />

211<br />

259<br />

291.6<br />

C (right)<br />

172<br />

Instruction plate<br />

104.9<br />

6<br />

86.1<br />

95<br />

D (front)<br />

90<br />

D (right)<br />

C (rear)<br />

172<br />

86.5<br />

220<br />

180<br />

550<br />

180<br />

214<br />

L<br />

44.7<br />

20<br />

Mark<br />

A<br />

B<br />

C<br />

D<br />

F<br />

G<br />

H<br />

K<br />

L<br />

Item<br />

Service valve connection (gas side)<br />

Service valve connection (liquid line)<br />

Refrigerant pipe draw-out port<br />

Power cable draw-in port<br />

Anchor bolt hole<br />

Drain hose hole<br />

Drain discharge port<br />

Oil-equalising pipe joint<br />

Sling holes for haulage or hoisting<br />

For refrigerant piping, please<br />

refer to the unit specifications.<br />

ø100<br />

ø50<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø9.52 flare<br />

180 x 44.7<br />

Notes:<br />

(1) The unit must be fixed with anchor bolts.<br />

(2) Leave a 2m or larger space above the unit.<br />

(3) The unit name plate is attached on the lower right corner of<br />

the front panel.<br />

(4) The ports for refrigerant pipe and power cable penetrations<br />

are covered with half-blanks. Please cut off a half-blank with<br />

nippers in using these ports.<br />

(5) Use a ø88 port for refrigerant pipe connection.<br />

(6) Anchor holes marked “L J” (four holes for M10) are for a<br />

renewal installation.<br />

(7) The oil-equalising pipe K should be used when outdoor units<br />

are used in combination.<br />

29


R410A<br />

refrigerant piping<br />

Installation of Interconnecting Pipework<br />

Mitsubishi KX6 equipment is manufactured to<br />

the highest standards of quality and reliability.<br />

It is imperative the method of installation and<br />

the materials used are also to high standards,<br />

to ensure trouble free operation and long term<br />

reliability.<br />

The interconnecting pipework must be installed<br />

by a competent and trained engineer.<br />

Refrigeration quality copper tube must be used,<br />

soft copper coils or half-hard straight lengths.<br />

The refrigeration quality tube must be soft<br />

drawn seamless high grade copper pipe. The<br />

copper tube must be selected taking into<br />

account the higher operating pressures of<br />

R410A refrigerant, and that high pressures will<br />

occur throughout the <strong>system</strong> because of the<br />

reverse cycle operation. All pipework material<br />

used should be EN12735 European standard.<br />

The supplied branch pipe kits, must be used<br />

to make connections to indoor units, and the<br />

supplied manifold kits must be used to make<br />

connections between outdoor units (where<br />

applicable); it is not permitted to use standard<br />

fittings such as elbows, tees etc. The branch<br />

pipes shall be installed in accordance with the<br />

manufacturer’s instructions, allowing<br />

unrestricted flow of refrigerant, and in<br />

accordance with European standard E378:2000.<br />

All brazed joints shall be made with dry<br />

nitrogen purge to ensure the prevention of<br />

oxidisation to the internal surface of the copper<br />

pipes.<br />

The ingress of moisture, dirt and any other<br />

contaminants to the interior of the copper<br />

pipes, and air conditioning units, must be<br />

prevented during the installation procedure.<br />

After the installation of pipework, prior to the<br />

connection of the outdoor units, and sealing of<br />

insulation joints, the pipework must be<br />

pressure tested for leakage, using dry nitrogen.<br />

Additional Refrigerant<br />

Additional R410A refrigerant only shall be used,<br />

and must be charged by weight only, using<br />

electronic scales. The amount of additional<br />

refrigerant must be accurately calculated from<br />

the manufacturerís data, based on the length<br />

and diameter of each section of the liquid<br />

refrigerant pipework of the <strong>system</strong>.<br />

Single outdoor unit piping examples:<br />

Piping arrangement using header<br />

HEAD8-371-1G<br />

90 90 56 56 36 36 36 36<br />

Liquid pipe<br />

Gas pipe<br />

Piping arrangement using<br />

branch pipe kits<br />

56 56 36 36 36 112 112 112<br />

30


efrigerant piping<br />

Pipe sizes applicable to European installations.<br />

Outdoor unit (HP) 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48<br />

Liquid pipe Furthest indoor unit ø9.52 ø12.7 ø15.88 ø19.05<br />

Gas pipe =90m<br />

ø22.22 ø28.58 ø34.92<br />

Branch pipes<br />

Header pipe<br />

Horizontally<br />

mm inch<br />

ø9.52 3/8"<br />

ø12.7 1/2"<br />

ø15.88 5/8"<br />

ø19.05 3/4"<br />

ø22.22 7/8"<br />

ø25.4 1"<br />

mm inch<br />

ø28.58 1 1/8 "<br />

ø31.8 1 1/4 "<br />

ø34.92 1 3/8 "<br />

ø38.1 1 1/2 "<br />

ø44.5 1 3/4 "<br />

ø50.8 2"<br />

Floor<br />

Good<br />

DIS-22-1G/DIS-180-1G<br />

HEAD6-180-1G<br />

Combination outdoor unit manifold<br />

Floor<br />

No<br />

Good<br />

Vertically<br />

No<br />

Floor<br />

DIS-371-1G/DIS-540-2G<br />

DOS-2A-1G<br />

Floor<br />

Combination outdoor unit piping examples:<br />

Oil equalisation<br />

pipe<br />

Outdoor unit branch<br />

pipe set (DOS-2A-1G)<br />

Piping arrangement using<br />

branch pipe kits<br />

112 112 90 90 90 140 140 140<br />

Oil equalisation<br />

pipe<br />

Outdoor unit branch<br />

pipe set (DOS-2A-1G)<br />

Piping arrangement using header<br />

HEAD8-540-2G<br />

112 112 90 90 90 140 140 140<br />

Outdoor unit's branching piping<br />

Outdoor unit<br />

2 units (for 735~1360)<br />

Branch piping set<br />

DOS-2A-1G<br />

Indoor unit's first branching piping<br />

Total capacity of Branch piping set<br />

indoor units<br />

~179<br />

DIS-22-1G<br />

180~370 DIS-180-1G<br />

371~539 DIS-371-1G<br />

540~<br />

DIS-540-2G<br />

Header set<br />

Model<br />

HEAD4-22-1G<br />

HEAD6-180-1G<br />

HEAD8-371-1G<br />

HEAD8-540-2G<br />

Branches<br />

Max 4 branches<br />

Max 6 branches<br />

Max 8 branches<br />

Max 8 branches<br />

31


R410A<br />

electrical wiring – power supply<br />

KX6 new design includes greatly simplified wiring requirements utilising a ‘polarity-free’ two wire control loop connecting the indoor units.<br />

Power wiring<br />

Cables can be laid through the front, right, left or bottom of the outdoor unit casing.<br />

Separate power supplies should be used for the outdoor unit (3/phase) and the indoor units (1/phase).<br />

Only control wiring is connected from outdoor to indoor unit.<br />

Outdoor unit power supply: 3 phase 4 wiring 380-415V<br />

Distributed, separate power supply <strong>system</strong><br />

Earth leakage breaker<br />

(Impulse withstanding type)<br />

Circuit breaker<br />

for cabling<br />

Grounding<br />

wire<br />

A<br />

A<br />

Outdoor unit<br />

A Power cable (Main Power cable)[4 cores]<br />

B Signal wire (Super Link wire)[2 cores]<br />

C Power cable (Indoor unit power cable)<br />

[2 cores]<br />

D Remote control cord<br />

[2 cores]<br />

B<br />

B<br />

C<br />

Circuit breaker<br />

for cabling<br />

Indoor unit<br />

Earth leakage breaker<br />

D<br />

R<br />

R R R R R<br />

Remote control unit<br />

Indoor unit power supply: Single phase 220-240V<br />

CAUTION<br />

If the earth leakage breaker is exclusively for ground fault protection, then you will need to install a circuit breaker for wiring work.<br />

KX6 outdoor unit mechanical compartment<br />

Electrical<br />

component box<br />

Outdoor unit power supply terminal block<br />

32


1.<br />

3.<br />

4.<br />

5.<br />

electrical wiring – control wiring<br />

The control wiring is 5 Volt DC,<br />

non-polarised, two wire connection<br />

notated as ‘A1’ and ‘B1’. This ‘AB’ wiring<br />

connects outdoor unit to indoor unit and<br />

indoor unit to indoor unit.<br />

2. This wiring must be a 2-core shielded<br />

cable size 0.75mm 2 or 1.25mm 2 .<br />

0.75mm 2 1.25mm 2<br />

~1000m YES YES<br />

1000~1500m YES NO<br />

We recommend the both ends of the<br />

shield of the cable are connected to<br />

ground (earth) at all the indoor units and<br />

outdoor units.<br />

When plural outdoor units are used,<br />

. Connect the signal cable between indoor<br />

and outdoor units and the signal cable<br />

between outdoor units belonging to the<br />

same refrigerant line to A1 and B1.<br />

. Connect the signal line between outdoor<br />

units on different refrigerant lines to A2<br />

and B2.<br />

For current specification of 2-core (AB)<br />

wiring, please consult your MHI dealer.<br />

(1) When one outdoor unit is used<br />

Outdoor signal line<br />

terminal block<br />

Indoor signal line<br />

terminal block<br />

A1<br />

B1<br />

(2) When plural outdoor units are used<br />

A B A B A B<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

Indoor unit<br />

A<br />

B<br />

Indoor unit<br />

A<br />

B<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

Signal line<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

Indoor unit<br />

Indoor and outdoor signal line do not have a polarity.<br />

Any of the connections in the following illustration can be made.<br />

(a) The maximum number of indoor units that can be connected in a <strong>system</strong> is 128 and it is possible to configure<br />

outdoor units and/or indoor units as an outdoor or indoor unit group connected with each other with two wires.<br />

(b) The signal wires can also be connected using the method shown below.<br />

A<br />

B<br />

Indoor unit<br />

A<br />

B<br />

A1<br />

B1<br />

A<br />

B<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

A1<br />

B1<br />

Refrigerant pipe<br />

A<br />

B<br />

Network connector<br />

(3) The signal lines can also be connected using the method shown below.<br />

Important<br />

Loop wiring prohibited<br />

Outdoor unit<br />

Outdoor unit<br />

Outdoor unit<br />

Outdoor unit Outdoor unit Outdoor unit Outdoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

The signal lines cannot form a loop,<br />

so the wirings shown as<br />

in the diagram are prohibited.<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit Indoor unit Indoor unit Indoor unit<br />

Remote control wiring specifications<br />

For interconnecting wiring between the remote control and<br />

indoor units (XY wiring) use 2-core cable size 0.3mm 2 . The<br />

maximum length of 2-core cable is 600 metres. Where the<br />

2-core wiring exceeds 100m, use the wire size detailed on<br />

the table opposite.<br />

Outdoor unit<br />

A B<br />

A B<br />

A B<br />

A B<br />

A B<br />

Length (m)<br />

Wire size<br />

100 to 200 0.5mm 2 x 2 core<br />

To 300<br />

0.75mm 2 x 2 core<br />

To 400<br />

1.25mm 2 x 2 core<br />

To 600<br />

2.0mm 2 x 2 core<br />

Indoor unit<br />

Remote control<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

Wires can be connected<br />

across different refrigerant<br />

<strong>system</strong>s when wired within<br />

1 Superlink <strong>system</strong><br />

33


R410A<br />

heat recovery <strong>system</strong>s - for simultaneous<br />

heating and cooling<br />

KXR6 heat recovery <strong>system</strong>s operate with 3 inter-connecting pipes,<br />

thus commonly referred to as a '3-pipe <strong>system</strong>'.<br />

where the building orientation (N, S, E, W) can mean that heat gain/loss<br />

varies on each side of the building.<br />

KXR6 <strong>system</strong>s provide both heating and cooling operations to individual<br />

indoor units according to the room condition/requirement.<br />

KXR6 incorporates highly sophisticated control to condition <strong>multi</strong>ple indoor<br />

areas, whatever their requirement for cooling or heating, for applications<br />

The range starts from the 8hp model (22.4kW) cooling capacity, up to the<br />

largest capacity single outdoor unit in the industry (24hp) with 68.0kW<br />

cooling capacity. Outdoor units can also be “twinned” providing up to<br />

48HP/136.0kW on a single <strong>system</strong>.<br />

8HP<br />

FDC224KXRE6<br />

18HP<br />

FDC504KXRE6<br />

10HP<br />

FDC280KXRE6<br />

20HP<br />

FDC560KXRE6<br />

12HP<br />

FDC335KXRE6<br />

20HP<br />

FDC560KXRE6-K<br />

12HP<br />

FDC335KXRE6-K<br />

22HP<br />

FDC615KXRE6<br />

14HP<br />

FDC400KXRE6<br />

24HP<br />

FDC680KXRE6<br />

16HP<br />

FDC450KXRE6<br />

26HP<br />

FDC735KXRE6<br />

28HP<br />

FDC800KXRE6<br />

30HP<br />

FDC850KXRE6<br />

32HP<br />

FDC900KXRE6<br />

34HP<br />

FDC960KXRE6<br />

36HP<br />

FDC1010KXRE6<br />

12+14 14+14 14+16 16+16 16+18 18+18<br />

FDC335KXRE6-K<br />

FDC400KXRE6<br />

38HP<br />

FDC1065KXRE6<br />

FDC400KXRE6 FDC400KXRE6<br />

FDC400KXRE6 FDC450KXRE6<br />

40HP<br />

FDC1130KXRE6<br />

42HP<br />

FDC1180KXRE6<br />

FDC450KXRE6<br />

FDC450KXRE6<br />

44HP<br />

FDC1235KXRE6<br />

FDC450KXRE6<br />

FDC504KXRE6<br />

46HP<br />

FDC1300KXRE6<br />

FDC504KXRE6<br />

FDC504KXRE6<br />

48HP<br />

FDC1360KXRE6<br />

18+20 20+20 20+22 22+22 22+24 24+24<br />

FDC504KXRE6<br />

FDC560KXRE6<br />

FDC560KXRE6 FDC560KXRE6-K FDC615KXRE6<br />

FDC560KXRE6 FDC615KXRE6 FDC615KXRE6<br />

1.12HP, 20HP, 22HP & 24HP are applied 3D compressor.<br />

2.FDC335KXRE6-K & FDC560KXRE6-K are only used for combining with other models.<br />

FDC615KXRE6<br />

FDC680KXRE6<br />

FDC680KXRE6<br />

FDC680KXRE6<br />

Capacity connection<br />

HP<br />

8~12<br />

14,16<br />

18~34<br />

36~48<br />

KXR4<br />

130%<br />

130%<br />

130%<br />

130%<br />

HP<br />

8~16<br />

18~34<br />

36~48<br />

KXR6<br />

200%<br />

160%<br />

130%<br />

• In case that capacity connection is more<br />

than 130%, additional charge of<br />

refrigerant is required on site.<br />

• In case of 8-34HP of KXR6 <strong>system</strong>, if one<br />

or more indoor units of FDK, FDFL,FDFU<br />

and/or FDFW series are connected to the<br />

<strong>system</strong>, the total connecting capacity of<br />

indoor units should not exceed 130%.<br />

Up to 80 indoor units can be connected to the largest capacity outdoor unit, with a range of 16 types of exposed or concealed indoor unit, in several capacities, a<br />

choice of 80 indoor units is available.<br />

FDT FDTC FDTW FDTQ<br />

FDTS<br />

FDU<br />

FDUM<br />

FDUT<br />

FDUH<br />

FDK<br />

FDE<br />

FDFW<br />

FDFL FDFU FDU-F SAF<br />

SAF-DX<br />

34


KXR6 heat recovery <strong>system</strong>s - for simultaneous heating and cooling<br />

The KXR6 <strong>system</strong> interconnecting pipework has a unique arrangement, with two of the interconnecting pipes routed through a<br />

PFD Distribution Controller, and the third pipe connected directly to each indoor unit from the main pipe run. This reduces<br />

installation time, and the number of brazed connections on site. The PFD Distribution Controllers are available for single<br />

connection, or as a combined PFD 4-way connection, with each connected unit having independent cooling or heating operation.<br />

Cooling and heating balanced operation<br />

During defrosting or during automatic protection of a compressor, which is activated every several hours in heating operation, heating operation temporarily<br />

stops and restarts after some period. KXR6 series has the same automatic protection of compressor in cooling operation also. During this protection period air<br />

flow only comes on and cooling operation restarts after some period.<br />

This model is not suitable for the usage of annual cooling operation such as for the server room, especially in the area where the outdoor air temperature<br />

becomes below 5ºC. In case of mixed opeartion in cooling and heating mode below 5ºC of outdoor air temperature, the cooling capacity may decrease in<br />

comparison with that for the operation only in cooling mode.<br />

The industry's highest COP levels<br />

We have cleared the class A standard, the highest energy saving level, with our high COP (Coefficient Of Performance).<br />

EER in Cooling<br />

COP<br />

4.5<br />

4.0<br />

3.5<br />

3.80<br />

3.47<br />

A<br />

CLASS<br />

3.36 3.45<br />

3.34<br />

3.32<br />

3.2<br />

COP in Heating<br />

COP<br />

4.5<br />

4.0<br />

3.5<br />

4.24<br />

3.88<br />

3.93<br />

A<br />

CLASS<br />

3.77<br />

3.75<br />

3.74<br />

3.6<br />

3.0<br />

3.0<br />

*<br />

*<br />

2.5<br />

2.5<br />

8 10 12 14 16 18 HP<br />

8 10 12 14 16 18 HP<br />

(ISO-T1 conditions)<br />

COP = Capacity[kW] / Power Consumption[kW]<br />

COP across the KXR6 range ensures reduced running costs and reduced environmental impact.<br />

35


R410A<br />

Outdoor units<br />

Heat recovery 3-pipe <strong>system</strong>s 8, 10, 12, 14, 16hp<br />

(22.4kW – 45.0kW) for simultaneous heating and cooling<br />

Model No.<br />

FDC224KXRE6<br />

FDC280KXRE6<br />

FDC335KXRE6<br />

FDC400KXRE6<br />

FDC450KXRE6<br />

Nominal Cooling Capacity<br />

22.4kW<br />

28.0kW<br />

33.5kW<br />

40.0kW<br />

45.0kW<br />

•The KXR6 heat recovery <strong>system</strong>s offer high performance <strong>VRF</strong> for almost<br />

every type of building, with the capacity for simultaneous heating and<br />

cooling operations of individual indoor units. Energy efficiency is<br />

maximised by employing DC <strong>inverter</strong> compressors ONLY, and distributing<br />

surplus heat from cooling operations to areas where it is required (and<br />

vice versa) resulting in COP (in cooling) from 3.7 to 4.2.<br />

•Connect from 50% up to 200% capacity indoor units.<br />

•Industry leading total piping length up to 1000m and a maximum pipe run<br />

of 160m.<br />

Uniform footprint of all models (from<br />

8hp~24 hp) allows continuous sideby-side<br />

installation<br />

Total length: 1000m<br />

Outdoor unit<br />

Range of operation<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

To the<br />

first branch:<br />

max 130m<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 90m*<br />

Specifications<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Operating<br />

current<br />

HxWxD<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Suction Gas line<br />

Discharge Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

in (mm)<br />

%<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

* The difference between the longest and the shortest indoor unit piping<br />

from the first branch must be within 40m.<br />

FDC224KXRE6<br />

8HP<br />

22.4<br />

25.0<br />

5.90<br />

5.90<br />

9.1-8.3<br />

9.2-8.4<br />

269<br />

8.7<br />

57/57<br />

ø9.52(3/8”)<br />

ø19.05(3/4”)<br />

ø15.88(5/8”)<br />

20<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

18m<br />

Furthest<br />

indoor unit: 160m<br />

28.0<br />

31.5<br />

5<br />

8.08<br />

8.11<br />

12.9-11.7<br />

12.8-11.8<br />

9.9<br />

58/59<br />

-10<br />

-20<br />

10<br />

0<br />

20<br />

30<br />

40<br />

50<br />

ø25.4(1”) [ø22.22(7/8")]<br />

ø19.05(3/4”)<br />

50~200<br />

25<br />

30<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

-20ºC<br />

+15.5ºC<br />

Heating<br />

FDC280KXRE6 FDC335KXRE6 FDC400KXRE6 FDC450KXRE6<br />

10HP<br />

12HP<br />

14HP<br />

16HP<br />

3 Phase 380-415V, 50Hz<br />

33.5<br />

40.0<br />

45.0<br />

37.5<br />

45.0<br />

50.0<br />

9.98<br />

9.55<br />

15.9-14.8<br />

15.5-14.2<br />

1690x1350x720<br />

273<br />

11.4<br />

62/63<br />

11.61<br />

11.93<br />

19.0-17.4<br />

19.9-18.2<br />

358<br />

11.5<br />

60/60<br />

62.5/62.5<br />

ø12.7(1/2”)<br />

ø25.4(1”) [ø28.58(1 1/8")]<br />

ø22.22(7/8”)<br />

36<br />

8<br />

13.49<br />

13.32<br />

21.6-19.8<br />

22.0-20.1<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

40<br />

36


Dimensions<br />

All measurements in mm.<br />

Mark Content 224<br />

280<br />

335<br />

A Refrigerant suction gas piping connection entrance ø19.05(Brazing) ø22.22(Brazing)<br />

B Refrigerant liquid piping connection entrance<br />

ø9.52(Flare)<br />

C Refrigerant discharge gas piping connection entrance ø15.88(Brazing)<br />

ø19.05(Brazing)<br />

D Power supply entry hole<br />

F Anchor bolt hole<br />

G Drain waste water hose hole<br />

H Drain hole<br />

K * Refrigerant oil equalization piping connection entrance<br />

L Carrying in or hole for hanging<br />

N Refrigerant piping exit hole<br />

*14,16HP models only<br />

335-K<br />

ø25.4(Brazing)<br />

ø12.7(Flare)<br />

400<br />

450<br />

ø28.58(Brazing)<br />

ø22.22(Brazing)<br />

ø50(right . left . front),long hole 40x80(under side)<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø9.52(Flare)<br />

180x44.7<br />

ø88(or ø100)<br />

Notes:<br />

(1) Make sure to secure the unit with anchor bolts.<br />

(2) Make sure to allow the space of 2m or more above the unit.<br />

(3) Connect the refrigerant piping (suction gas side, discharge gas side, liquid side) at local site.<br />

(4) The refrigerant piping connection entrance and the power supply intake are of the half blank<br />

shape. Cut it with the nipper etc., when you use.<br />

(5) Use ø88 (or ø100) for the refrigerant piping connection entrance.<br />

(6) Please use the anchor hole (M10x10) marked I and J and M for a renewal purpose.<br />

(7) Please connect the oil equalization pipe marked K with only the outdoor combination unit.<br />

(for 14,16HP only)<br />

(8) Please use combination trestle (option) when you use the trestle by outdoor combination<br />

unit. (for 14,16HP only)<br />

Installation example<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

H1<br />

H2<br />

1<br />

500<br />

10<br />

100<br />

10<br />

1500<br />

No limited<br />

2<br />

Open<br />

10<br />

100<br />

Open<br />

–<br />

No limited<br />

H3<br />

H4<br />

1000<br />

No limited<br />

No limited<br />

–<br />

37


R410A<br />

Outdoor units<br />

Heat recovery 3-pipe <strong>system</strong>s 18, 20, 22, 24hp<br />

(50.4kW – 68.0kW) for simultaneous heating and cooling<br />

Model No.<br />

FDC504KXRE6<br />

FDC560KXRE6<br />

FDC615KXRE6<br />

FDC680KXRE6<br />

Nominal Cooling Capacity<br />

50.4kW<br />

56.0kW<br />

61.5kW<br />

68.0kW<br />

•The KXR6 heat recovery <strong>system</strong>s offer high performance <strong>VRF</strong> for almost<br />

every type of building, with the capacity for simultaneous heating and<br />

cooling operations of individual indoor units. Energy efficiency is<br />

maximised by employing DC <strong>inverter</strong> compressors ONLY, and distributing<br />

surplus heat from cooling operations to areas where it is required (and<br />

vice versa) resulting in COP (in cooling) from 2.6 to 3.3.<br />

•Connect from 50% up to 160% capacity indoor units.<br />

•Industry leading total piping length up to 1000m and a maximum pipe run<br />

of 160m.<br />

Uniform footprint of all models (from<br />

8hp~24hp) allows continuous sideby-side<br />

installation<br />

Specifications<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Total length: 1000m<br />

To the<br />

first branch:<br />

max 130m<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 90m*<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Operating<br />

current<br />

HxWxD<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Suction Gas line<br />

Discharge Gas line<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

in (mm)<br />

Outdoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

* The difference between the longest and the shortest indoor unit piping<br />

from the first branch must be within 40m.<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

FDC504KXRE6 FDC560KXRE6 FDC615KXRE6 FDC680KXRE6<br />

18HP<br />

20HP<br />

22HP<br />

24HP<br />

3 Phase 380-415V, 50Hz<br />

50.4<br />

56.5<br />

15.18<br />

15.12<br />

23.8-21.8<br />

25.2-23.1<br />

62/62<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

18m<br />

Furthest<br />

indoor unit: 160m<br />

380<br />

11.5<br />

ø22.22(7/8”)<br />

Range of operation<br />

Capacity connection<br />

%<br />

50~160<br />

Number of connectable indoor units<br />

36<br />

40<br />

44<br />

49<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

56.0<br />

63.0<br />

17.95<br />

16.79<br />

28.4-26.0<br />

28.0-25.7<br />

63.5/63.5<br />

-10<br />

-20<br />

10<br />

0<br />

20<br />

30<br />

40<br />

8<br />

50<br />

2048x1350x720<br />

ø12.7(1/2”)<br />

ø28.58(1 1/8”)<br />

-15ºC<br />

+43ºC<br />

Cooling<br />

61.5<br />

69.0<br />

21.47<br />

19.11<br />

34.7-31.8<br />

31.6-28.9<br />

64/64.5<br />

-20ºC<br />

+15.5ºC<br />

Heating<br />

399<br />

11.5<br />

ø25.4(1”) [ø22.22(7/8")]<br />

68.0<br />

73.0<br />

25.99<br />

19.69<br />

44.9-41.1<br />

34.0-31.1<br />

65.5/65.5<br />

38


Dimensions<br />

All measurements in mm.<br />

Mark Content 504 560 560-K 615 680<br />

A<br />

B<br />

Refrigerant suction gas piping connection entrance<br />

Refrigerant liquid piping connection entrance<br />

ø28.58(Brazing)<br />

ø12.7(Flare)<br />

C Refrigerant discharge gas piping connection entrance ø22.22(Brazing) ø25.4(Brazing)<br />

D<br />

F<br />

G<br />

H<br />

K<br />

L<br />

N<br />

Power supply entry hole<br />

Anchor bolt hole<br />

Drain waste water hose hole<br />

Drain hole<br />

Refrigerant oil equalization piping connection pipe<br />

Carrying in or hole for hanging<br />

Refrigerant piping exit hole<br />

ø50(right . left . front),long hole 40x80(under side)<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø9.52(Flare)<br />

180x44.7<br />

ø88(or ø100)<br />

Installation example<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

H1<br />

H2<br />

H3<br />

H4<br />

1<br />

500<br />

10<br />

100<br />

10<br />

1500<br />

No limited<br />

1000<br />

No limited<br />

2<br />

Open<br />

10<br />

100<br />

Open<br />

–<br />

No limited<br />

No limited<br />

–<br />

Notes:<br />

(1) Make sure to secure the unit with anchor bolts.<br />

(2) Make sure to allow the space of 2m or more above the unit.<br />

(3) Connect the refrigerant piping (suction gas side, discharge gas side, liquid side) at local site.<br />

(4) The refrigerant piping connection entrance and the power supply intake are of the half blank<br />

shape. Cut it with the nipper etc., when you use.<br />

(5) Use ø88 (or ø100) for the refrigerant piping connection entrance.<br />

(6) Please use the anchor hole (M10x10) marked I and J and M for a renewal purpose.<br />

(7) Please connect the oil equalization pipe marked K with only the outdoor combination unit.<br />

(8) Please use combination trestle (option) when you use the trestle by outdoor combination<br />

unit.<br />

39


R410A<br />

Outdoor units<br />

Heat recovery 3-pipe combination <strong>system</strong>s 26, 28, 30, 32hp<br />

(73.5kW – 90.0kW) for simultaneous heating and cooling<br />

Model No.<br />

FDC735KXRE6 (FDC335-K+FDC400)<br />

FDC800KXRE6 (FDC400x2)<br />

FDC850KXRE6 (FDC400+FDC450)<br />

FDC900KXRE6 (FDC450x2)<br />

Nominal Cooling Capacity<br />

73.5kW<br />

80.0kW<br />

85.0kW<br />

90.0kW<br />

•The KXR6 heat recovery <strong>system</strong>s offer high performance <strong>VRF</strong> for almost<br />

every type of building, with the capacity for simultaneous heating and<br />

cooling operations of individual indoor units. Energy efficiency is<br />

maximised by employing DC <strong>inverter</strong> compressors ONLY, and distributing<br />

surplus heat from cooling operations to areas where it is required (and<br />

vice versa) resulting in COP (in cooling) from 3.3 to 3.5.<br />

•Connect from 50% up to 160% capacity indoor units.<br />

•Industry leading total piping length up to 1000m and a maximum pipe run<br />

of 160m.<br />

Uniform footprint of all<br />

models (from 8hp~24hp)<br />

allows continuous side-byside<br />

installation<br />

Total length: 1000m<br />

Outdoor unit<br />

Specifications<br />

Item<br />

Combination (FDC)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

To the<br />

first branch:<br />

max 130m<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 90m*<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Operating<br />

current<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Suction Gas line<br />

Discharge Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

in (mm)<br />

%<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

* The difference between the longest and the shortest indoor unit piping<br />

from the first branch must be within 40m.<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

Range of operation<br />

FDC735KXRE6 FDC800KXRE6 FDC850KXRE6 FDC900KXRE6<br />

335KXRE6-K<br />

400KXRE6<br />

26HP<br />

73.5<br />

82.5<br />

21.08<br />

21.3<br />

34.4-31.5<br />

35.4-32.4<br />

ø25.4(1”)[ø28.58(1 1/8”)]<br />

53<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

18m<br />

Furthest<br />

indoor unit: 160m<br />

400KXRE6<br />

400KXRE6<br />

28HP<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

80.0<br />

90.0<br />

23.22<br />

23.86<br />

38.0-34.8<br />

39.8-36.4<br />

-10<br />

-20<br />

10<br />

0<br />

20<br />

30<br />

40<br />

50<br />

-15ºC<br />

3 Phase 380-415V, 50Hz<br />

16<br />

+43ºC<br />

Cooling<br />

400KXRE6<br />

450KXRE6<br />

30HP<br />

85.0<br />

95.0<br />

25.10<br />

25.25<br />

40.6-37.2<br />

41.9-38.3<br />

-20ºC<br />

1690x2700x720<br />

358x2<br />

33<br />

ø15.88(5/8”)<br />

ø31.75(1 1/4”)[ø34.92(1 3/8”)]<br />

ø28.58(1 1/8”)<br />

50~160<br />

58<br />

61<br />

+15.5ºC<br />

Heating<br />

450KXRE6<br />

450KXRE6<br />

32HP<br />

90.0<br />

100.0<br />

26.98<br />

26.64<br />

43.2-39.6<br />

44.0-40.2<br />

65<br />

40


Dimensions<br />

All measurements in mm.<br />

Mark Content 335-K<br />

400<br />

450<br />

A Refrigerant suction gas piping connection entrance<br />

ø25.4(Brazing) ø28.58(Brazing)<br />

B Refrigerant liquid piping connection entrance<br />

ø12.7(Flare)<br />

C Refrigerant discharge gas piping connection entrance ø19.05(Brazing) ø22.22(Brazing)<br />

D Power supply entry hole<br />

ø50(right . left . front),long hole 40x80(under side)<br />

F Anchor bolt hole<br />

M10 x 4 places<br />

G Drain waste water hose hole<br />

ø45 x 3 places<br />

H Drain hole<br />

ø20 x 6 places<br />

K * Refrigerant oil equalization piping connection entrance<br />

ø9.52(Flare)<br />

L Carrying in or hole for hanging<br />

180x44.7<br />

N Refrigerant piping exit hole<br />

ø88(or ø100)<br />

Installation example<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

H1<br />

H2<br />

H3<br />

H4<br />

1<br />

500<br />

10<br />

100<br />

10<br />

1500<br />

No limited<br />

1000<br />

No limited<br />

2<br />

Open<br />

10<br />

100<br />

Open<br />

–<br />

No limited<br />

No limited<br />

–<br />

*14,16HP models only<br />

Notes:<br />

(1) Make sure to secure the unit with anchor bolts.<br />

(2) Make sure to allow the space of 2m or more above the unit.<br />

(3) Connect the refrigerant piping (suction gas side, discharge gas side, liquid side) at local site.<br />

(4) The refrigerant piping connection entrance and the power supply intake are of the half blank<br />

shape. Cut it with the nipper etc., when you use.<br />

(5) Use ø88 (or ø100) for the refrigerant piping connection entrance.<br />

(6) Please use the anchor hole (M10x10) marked I and J and M for a renewal purpose.<br />

(7) Please connect the oil equalization pipe marked K with only the outdoor combination unit.<br />

(for 14,16HP only)<br />

(8) Please use combination trestle (option) when you use the trestle by outdoor combination<br />

unit. (for 14,16HP only)<br />

41


R410A<br />

Outdoor units<br />

Heat recovery 3-pipe combination <strong>system</strong>s<br />

34, 36, 38, 40, 42, 44, 46, 48hp (96.0kW – 136.0kW)<br />

for simultaneous heating and cooling<br />

Model No.<br />

FDC960KXRE6 (FDC450+FDC504)<br />

FDC1010KXRE6 (FDC504x2)<br />

FDC1065KXRE6 (FDC504+FDC560)<br />

FDC1130KXRE6 (FDC560x2)<br />

FDC1180KXRE6 (FDC560-K+FDC615)<br />

FDC1235KXRE6 (FDC615x2)<br />

FDC1300KXRE6 (FDC615+FDC680)<br />

FDC1360KXRE6 (FDC680x2)<br />

Nominal Cooling Capacity<br />

96.0kW<br />

101.0kW<br />

106.5kW<br />

113.0kW<br />

118.0kW<br />

123.5kW<br />

130.0kW<br />

136.0kW<br />

•The KXR6 heat recovery <strong>system</strong>s offer high performance <strong>VRF</strong> for almost every type<br />

of building, with the capacity for simultaneous heating and cooling operations of<br />

individual indoor units. Energy efficiency is maximised by employing DC <strong>inverter</strong><br />

compressors ONLY, and distributing surplus heat from cooling operations to areas<br />

where it is required (and vice versa) resulting in COP (in cooling) from 3.3 to 3.8.<br />

•Connect from 50% up to 130% capacity indoor units (960KXRE6:160%).<br />

•Industry leading total piping length up to 1000m and a maximum pipe run of 160m.<br />

Total length: 1000m<br />

Outdoor unit<br />

Range of operation<br />

42<br />

Specifications<br />

Item<br />

Combination (FDC)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

To the<br />

first branch:<br />

max 130m<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 90m*<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Operating<br />

current<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Suction Gas line<br />

Discharge Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg 358+380<br />

kg<br />

ø15.88(5/8”)<br />

in (mm) ø31.75(1 1/4”)[ø34.92(1 3/8”)]<br />

%<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

* The difference between the longest and the shortest indoor unit piping<br />

from the first branch must be within 40m.<br />

FDC960KXRE6 FDC1010KXRE6 FDC1065KXRE6 FDC1130KXRE6 FDC1180KXRE6 FDC1235KXRE6 FDC1300KXE6 FDC1360KXRE6<br />

450KXRE6 504KXRE6 504KXRE6 560KXRE6 560KXRE6-K 615KXRE6 615KXRE6 680KXRE6<br />

504KXRE6 504KXRE6 560KXRE6 560KXRE6 615KXRE6 615KXRE6 680KXRE6 680KXRE6<br />

34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP<br />

3 Phase 380-415V, 50Hz<br />

96.0<br />

108.0<br />

28.67<br />

28.44<br />

45.4-41.6<br />

47.2-43.2<br />

50~160<br />

69<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

18m<br />

Furthest<br />

indoor unit: 160m<br />

101.0<br />

113.0<br />

30.36<br />

30.24<br />

47.6-43.6<br />

50.4-46.2<br />

59<br />

106.5<br />

119.5<br />

33.13<br />

31.91<br />

52.2-47.8<br />

53.2-48.8<br />

380x2<br />

62<br />

-10<br />

-20<br />

113.0<br />

127.0<br />

35.9<br />

33.58<br />

56.8-52.0<br />

56.0-51.4<br />

10<br />

0<br />

20<br />

30<br />

40<br />

16<br />

50<br />

-15ºC<br />

118.0<br />

132.0<br />

+43ºC<br />

Cooling<br />

39.42<br />

35.9<br />

63.1-57.8<br />

59.6-54.6<br />

2048x2700x720<br />

-20ºC<br />

123.5<br />

138.0<br />

42.94<br />

38.22<br />

69.4-63.6<br />

63.2-57.8<br />

33<br />

ø19.05(3/4”)<br />

ø38.1(1 1/2”)[ø34.92(1 3/8”)]<br />

ø28.58(1 1/8”)<br />

50~130<br />

66<br />

69<br />

72<br />

+15.5ºC<br />

Heating<br />

399x2<br />

130.0<br />

142.0<br />

47.46<br />

38.80<br />

79.6-72.9<br />

65.6-60.0<br />

76<br />

136.0<br />

146.0<br />

51.98<br />

39.38<br />

89.8-82.2<br />

68.0-62.2<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

80


Dimensions<br />

All measurements in mm.<br />

Mark Content 504 560 560-K 615 680<br />

A<br />

B<br />

Refrigerant suction gas piping connection entrance<br />

Refrigerant liquid piping connection entrance<br />

ø28.58(Brazing)<br />

ø12.7(Flare)<br />

C Refrigerant discharge gas piping connection entrance ø22.22(Brazing) ø25.4(Brazing)<br />

D<br />

F<br />

G<br />

H<br />

K<br />

L<br />

N<br />

Power supply entry hole<br />

Anchor bolt hole<br />

Drain waste water hose hole<br />

Drain hole<br />

Refrigerant oil equalization piping connection pipe<br />

Carrying in or hole for hanging<br />

Refrigerant piping exit hole<br />

ø50(right . left . front),long hole 40x80(under side)<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø9.52(Flare)<br />

180x44.7<br />

ø88(or ø100)<br />

Installation example<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

H1<br />

H2<br />

H3<br />

H4<br />

1<br />

500<br />

10<br />

100<br />

10<br />

1500<br />

No limited<br />

1000<br />

No limited<br />

2<br />

Open<br />

10<br />

100<br />

Open<br />

–<br />

No limited<br />

No limited<br />

–<br />

Notes:<br />

(1) Make sure to secure the unit with anchor bolts.<br />

(2) Make sure to allow the space of 2m or more above the unit.<br />

(3) Connect the refrigerant piping (suction gas side, discharge gas side, liquid side) at local site.<br />

(4) The refrigerant piping connection entrance and the power supply intake are of the half blank<br />

shape. Cut it with the nipper etc., when you use.<br />

(5) Use ø88 (or ø100) for the refrigerant piping connection entrance.<br />

(6) Please use the anchor hole (M10x10) marked I and J and M for a renewal purpose.<br />

(7) Please connect the oil equalization pipe marked K with only the outdoor combination unit.<br />

(8) Please use combination trestle (option) when you use the trestle by outdoor combination<br />

unit.<br />

43


R410A<br />

PFD refrigerant flow<br />

branch control<br />

Branch control<br />

PFD1123-E<br />

PFD1803-E<br />

PFD2803-E<br />

PFD1123X4-E<br />

Total downstream indoor unit capacity<br />

less than 11.2kW<br />

less than 18.0kW<br />

28.0kW or less<br />

less than 44.8kW(less than 11.2kWx4 branches)<br />

Relay kit<br />

(Relay kit comes attached<br />

to the branch control)<br />

•The remote control setting (as individual indoor unit on-off, temperature<br />

setting other than cooling/heating mode control) is possible with one<br />

remote control connected to each indoor unit, while at the same time,<br />

Center Control (SC-SL1N/2NA/3NA-E) can be used together with the<br />

individual remote control.<br />

•It is necessary to set the central control to use this function. Please<br />

refer to the Installation Manual for details.<br />

KXR<br />

PFD<br />

PFD<br />

Same mode (Heating or Cooling)<br />

Individual on-off, temperature setting<br />

Heating<br />

Heating<br />

Heating<br />

•In case of the mode changeover from cooling to heating and from cooling<br />

to heating, by the use of only the indoor units and PFD box combination,<br />

the mode changeover sound was reduced. All this made possible without<br />

turning off the compressor and at the same time without the reduction of<br />

capacity.<br />

•The risk of refrigerant leakage was reduced by changing piping connection<br />

at the PFD box to brazing method.<br />

•By the use of optional PFD box<br />

extension cable that has a connector<br />

at ends, makes it possible to further<br />

separate the indoor unit and PFD<br />

box. This will enable the PFD box to<br />

be located away from the indoor<br />

unit and help reduce the influence of<br />

sound caused by PFD box and<br />

refrigerant flow.<br />

extension cable 15m<br />

PFD-15WR-E (option)<br />

Cooling<br />

SC-SL1N/2NA/3NA-E<br />

central control<br />

Easy installation<br />

New PFD design means the<br />

connection of the indoor unit liquid<br />

pipe is made directly to the liquid<br />

line - bypassing the PFD. This<br />

means (x2) less pipe connections<br />

per indoor unit, reducing<br />

installation time and cost.<br />

Outdoor<br />

unit<br />

suction gas pipe<br />

discharge gas pipe<br />

PFD<br />

controller<br />

liquid pipe<br />

gas pipe<br />

Indoor<br />

unit<br />

The PFD is connected to the<br />

indoor unit by 3 core signal wire<br />

via a relay kit (supplied) to be<br />

located within 2m of each other.<br />

The indoor unit however can be<br />

up to 40m away. Power to the<br />

PFD can be connected from the<br />

indoor unit or other supply.<br />

PFD<br />

Power cable 240v AC<br />

relay kit<br />

240v AC<br />

12v DC<br />

up to 2m<br />

up to 40m<br />

Indoor<br />

unit<br />

Groups of indoor units can be connected up to a total<br />

capacity 44.8kW to a single PFD with branch piping and<br />

all units in that group will operate in the same mode<br />

only (cooling or heating).<br />

We also have introduced the 4-way PFD control<br />

PFD1123X4-E which can connect up to four indoor<br />

units with individual control - simultaneous cooling or<br />

heating.<br />

Branch control Total downstream capacity * Connectable indoor units<br />

PFD1123-E less than 11.2kW 1-5<br />

PFD1803-E less than 18.0kW 1-8<br />

PFD2803-E 28.0kW or less 1-10<br />

PFD1123X4-E less than 44.8kW(less than 11.2kWx4 branches) Up to 20<br />

*Refer to Data Book for details<br />

PFD1123-E PFD1123-E PFD1123X4-E PFD1123-E<br />

4-Way PFD box<br />

90 56 36 56<br />

36 90<br />

28 90<br />

44


Dimensions<br />

All measurements in mm.<br />

PFD1123-E<br />

PFD1803-E<br />

PFD2803-E<br />

PFD1123X4-E<br />

45


R410A<br />

refrigerant piping<br />

Installation of Interconnecting Pipework<br />

Mitsubishi KXR6 equipment is manufactured to<br />

the highest standards of quality and reliability.<br />

It is imperative the method of installation and<br />

the materials used are also to high standards,<br />

to ensure trouble free operation and long term<br />

reliability.<br />

The interconnecting pipework must be installed<br />

by a competent and trained engineer.<br />

Refrigeration quality copper tube must be used,<br />

soft copper coils or half-hard straight lengths.<br />

The refrigeration quality tube must be soft<br />

drawn seamless high grade copper pipe. The<br />

copper tube must be selected taking into<br />

account the higher operating pressures of<br />

R410A refrigerant, and that high pressures will<br />

occur throughout the <strong>system</strong> because of the<br />

reverse cycle operation. All pipework material<br />

used should be EN12735 European standard.<br />

The supplied branch pipe kits, must be used<br />

to make connections to indoor units, and the<br />

supplied manifold kits must be used to make<br />

connections between outdoor units (where<br />

applicable); it is not permitted to use standard<br />

fittings such as elbows, tees etc. The branch<br />

pipes shall be installed in accordance with the<br />

manufacturer’s instructions, allowing<br />

unrestricted flow of refrigerant, and in<br />

accordance with European standard E378:2000.<br />

All brazed joints shall be made with dry<br />

nitrogen purge to ensure the prevention of<br />

oxidisation to the internal surface of the copper<br />

pipes.<br />

The ingress of moisture, dirt and any other<br />

contaminants to the interior of the copper<br />

pipes, and air conditioning units, must be<br />

prevented during the installation procedure.<br />

After the installation of pipework, prior to the<br />

connection of the outdoor units, and sealing of<br />

insulation joints, the pipework must be<br />

pressure tested for leakage, using dry nitrogen.<br />

Additional Refrigerant<br />

Additional R410A refrigerant only shall be used,<br />

and must be charged by weight only, using<br />

electronic scales. The amount of additional<br />

refrigerant must be accurately calculated from<br />

the manufacturerís data, based on the length<br />

and diameter of each section of the liquid<br />

refrigerant pipework of the <strong>system</strong>.<br />

Single outdoor unit piping examples:<br />

PFD1123-E PFD1123-E PFD1123X4-E<br />

PFD1123-E<br />

Liquid pipe<br />

Suction gas pipe<br />

Discharge gas pipe<br />

90 56 36 56<br />

36 90<br />

28 90<br />

PFD1123X4-E<br />

PFD1123-E<br />

PFD1123X4-E<br />

PFD2803-E<br />

56 36 56 36 56<br />

36 90 140<br />

28 90<br />

28 90<br />

46


efrigerant piping<br />

Pipe sizes applicable to European installations.<br />

Outdoor unit (HP) 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48<br />

Liquid pipe ø9.52<br />

ø12.7 ø15.88 ø19.05<br />

Suction Gas pipe Furthest indoor unit<br />

=90m<br />

ø22.22 ø28.58<br />

ø34.92<br />

Discharge Gas Pipe<br />

ø15.88 ø19.05 ø22.22<br />

ø28.58<br />

mm inch<br />

ø9.52 3/8"<br />

ø12.7 1/2"<br />

ø15.88 5/8"<br />

ø19.05 3/4"<br />

ø22.22 7/8"<br />

ø25.4 1"<br />

mm inch<br />

ø28.58 1 1/8 "<br />

ø31.8 1 1/4 "<br />

ø34.92 1 3/8 "<br />

ø38.1 1 1/2 "<br />

ø44.5 1 3/4 "<br />

ø50.8 2"<br />

Horizontally<br />

Floor<br />

Good<br />

Good<br />

No<br />

DIS-22-1-RG/DIS-180-1-RG<br />

DOS-2A-1-RG<br />

Vertically<br />

Floor<br />

Floor<br />

No<br />

Floor<br />

Oil equalisation<br />

pipe(1)<br />

Outdoor unit branch<br />

pipe set (DOS-2A-1-RG)<br />

PFD1123-E PFD1123X4-E PFD2803-E<br />

PFD1123-E<br />

90 56<br />

36 140 90 90<br />

28 90<br />

Outdoor unit's branching piping<br />

Outdoor unit<br />

2 units (for 735~1360)<br />

Branch piping set<br />

DOS-2A-1-RG<br />

Oil equalisation<br />

pipe(1)<br />

Outdoor unit branch<br />

pipe set (DOS-2A-1-RG)<br />

PFD1123X4-E<br />

PFD1123X4-E<br />

PFD1123-E<br />

PFD1123-E<br />

Indoor unit's first branching piping<br />

Total capacity of indoor units<br />

~179<br />

180~370<br />

371~539<br />

540~<br />

Branch piping set<br />

DIS-22-1-RG<br />

DIS-180-1-RG<br />

DIS-371-2-RG<br />

DIS-540-2-RG<br />

56<br />

28 90<br />

36 56 56<br />

28 90<br />

36 90 90<br />

For Down Stream of PFD box<br />

Total capacity of indoor units<br />

~179<br />

180~370<br />

371~539<br />

Branch piping set<br />

DIS-22-1G<br />

DIS-180-1G<br />

DIS-371-1G<br />

47


R410A<br />

electrical wiring – power supply<br />

KXR6 new design includes greatly simplified wiring requirements utilising a ‘polarity-free’ two wire control loop connecting the indoor units.<br />

Power wiring<br />

Cables can be laid through the front, right, left or bottom of the outdoor unit casing.<br />

Separate power supplies should be used for the outdoor unit (3/phase) and the indoor units (1/phase).<br />

Only control wiring is connected from outdoor to indoor unit.<br />

Outdoor unit power supply: 3 phase 4 wiring 380-415V<br />

Distributed, separate power supply <strong>system</strong><br />

Earth leakage breaker<br />

(Impulse withstanding type)<br />

Circuit breaker<br />

for cabling<br />

Grounding<br />

wire<br />

A<br />

A<br />

Outdoor unit<br />

A Power cable (Main Power cable)[4 cores]<br />

B Signal wire (Super Link wire)[2 cores]<br />

C Power cable (Indoor unit power cable)<br />

[2 cores]<br />

D Remote control cord<br />

[2 cores]<br />

B<br />

B<br />

C<br />

Circuit breaker<br />

for cabling<br />

Indoor unit<br />

Earth leakage breaker<br />

D<br />

R<br />

R R R R R<br />

Remote control unit<br />

Indoor unit power supply: Single phase 220-240V<br />

CAUTION<br />

If the earth leakage breaker is exclusively for ground fault protection, then you will need to install a circuit breaker for wiring work.<br />

KXR6 outdoor unit mechanical compartment<br />

Electrical<br />

component box<br />

Outdoor unit power supply terminal block<br />

48


1.<br />

The control wiring is 5 Volt DC,<br />

non-polarised, two wire connection<br />

notated as ‘A1’ and ‘B1’. This ‘AB’ wiring<br />

connects outdoor unit to indoor unit and<br />

indoor unit to indoor unit.<br />

2. This wiring must be a 2-core shielded<br />

cable size 0.75mm 2 or 1.25mm 2 .<br />

0.75mm 2 1.25mm 2<br />

~1000m YES YES<br />

1000~1500m YES NO<br />

3.<br />

4.<br />

5.<br />

We recommend the both ends of the<br />

shield of the cable are connected to<br />

ground (earth) at all the indoor units and<br />

outdoor units.<br />

When plural outdoor units are used,<br />

. Connect the signal cable between indoor<br />

and outdoor units and the signal cable<br />

between outdoor units belonging to the<br />

same refrigerant line to A1 and B1.<br />

. Connect the signal line between outdoor<br />

units on different refrigerant lines to A2<br />

and B2.<br />

For current specification of 2-core (AB)<br />

wiring, please consult your MHI dealer.<br />

electrical wiring – control wiring<br />

(1) When one outdoor unit is used<br />

Outdoor signal line<br />

terminal block<br />

Indoor signal line<br />

terminal block<br />

A1<br />

B1<br />

(2) When plural outdoor units are used<br />

A B A B A B<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

Indoor unit<br />

A<br />

B<br />

Indoor unit<br />

A<br />

B<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

Signal line<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

Indoor unit<br />

Indoor unit<br />

A<br />

B<br />

Indoor and outdoor signal line do not have a polarity.<br />

Any of the connections in the following illustration can be made.<br />

(a) The maximum number of indoor units that can be connected in a <strong>system</strong> is 128 and it is possible to configure<br />

outdoor units and/or indoor units as an outdoor or indoor unit group connected with each other with two wires.<br />

(b) The signal wires can also be connected using the method shown below.<br />

A<br />

B<br />

A1<br />

B1<br />

A<br />

B<br />

Outdoor unit<br />

A1·B1 A2·B2<br />

A1<br />

B1<br />

Refrigerant pipe<br />

A<br />

B<br />

Network connector<br />

(3) The signal lines can also be connected using the method shown below.<br />

Important<br />

Loop wiring prohibited<br />

Outdoor unit<br />

Outdoor unit<br />

Outdoor unit<br />

Outdoor unit Outdoor unit Outdoor unit Outdoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

The signal lines cannot form a loop,<br />

so the wirings shown as<br />

in the diagram are prohibited.<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit Indoor unit Indoor unit Indoor unit<br />

Remote control wiring specifications<br />

For interconnecting wiring between the remote control<br />

and indoor units (XY wiring) use 2-core cable size<br />

0.3mm 2 . The maximum length of 2-core cable is 600<br />

metres. Where the 2-core wiring exceeds 100m, use the<br />

wire size detailed on the table opposite.<br />

Outdoor unit<br />

A B<br />

A B<br />

A B<br />

A B<br />

A B<br />

Length (m)<br />

Wire size<br />

100 to 200 0.5mm 2 x 2 core<br />

To 300<br />

0.75mm 2 x 2 core<br />

To 400<br />

1.25mm 2 x 2 core<br />

To 600<br />

2.0mm 2 x 2 core<br />

Indoor unit<br />

Remote control<br />

Indoor unit<br />

Indoor unit<br />

Indoor unit<br />

Wires can be connected<br />

across different refrigerant<br />

<strong>system</strong>s when wired within<br />

1 Superlink <strong>system</strong><br />

49


R410A<br />

Indoor units<br />

Ceiling Cassette -4way-<br />

FDT<br />

Model No.<br />

FDT28KXE6F<br />

FDT36KXE6F<br />

FDT45KXE6F<br />

FDT56KXE6F<br />

FDT71KXE6F<br />

FDT90KXE6F<br />

FDT112KXE6F<br />

FDT140KXE6F<br />

FDT160KXE6F<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-T-36W-E<br />

Individual flap control <strong>system</strong><br />

According to room temperature conditions, four directions of air flow<br />

can be controlled by individual flap as preferred.<br />

As individual flap control is available even after installation,<br />

installation area became wider than before.<br />

The thinnest design<br />

Thanks to new design of heat exchanger<br />

changed from 2 parts to 1 part, the<br />

height of indoor unit is reduced<br />

drastically.<br />

Furthermore applying DC fan motors to<br />

FDT models, the highest energy<br />

efficiency level, reduction of weight and<br />

significant compact design are realized.<br />

Shape of Heat exchanger<br />

KX4<br />

KX6<br />

Due to optimization of outlet<br />

design of air flow with our<br />

new advanced technology,<br />

sufficient air flow is secured<br />

and long reach of air flow is<br />

realized.<br />

KX4<br />

KX6<br />

270mm<br />

246<br />

mm<br />

FDT28~71<br />

9%<br />

reduction!!<br />

365mm<br />

298<br />

mm<br />

FDT112~160<br />

18%<br />

reduction!!<br />

Flap control <strong>system</strong><br />

Selection of flap<br />

position is possible.<br />

Individual flaps can<br />

be set at different<br />

angles.<br />

Specifications<br />

RCH-E3 is not applicable to the<br />

Individual flap control <strong>system</strong><br />

and the Flap control <strong>system</strong>.<br />

*<br />

Upper<br />

position<br />

Movable<br />

range<br />

Lower<br />

position<br />

for person who is far from<br />

the indoor unit<br />

for both persons who are<br />

feeling hot or cold<br />

can cool both the kitchen and<br />

the guests<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

Sound pressure level<br />

Exterior dimensions<br />

H x W x D<br />

Model<br />

kW<br />

kW<br />

kW<br />

dB(A)<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow<br />

CMM<br />

Outside air intake<br />

Panel<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDT28KXE6F<br />

2.8<br />

3.2<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

FDT36KXE6F<br />

3.6<br />

4.0<br />

0.03-0.03<br />

0.03-0.03<br />

FDT45KXE6F<br />

4.5<br />

5.0<br />

Hi:33 Me:31 Lo:30<br />

FDT56KXE6F<br />

5.6<br />

6.3<br />

Unit:246x840x840 Panel:35x950x950<br />

FDT71KXE6F<br />

7.1<br />

8.0<br />

FDT90KXE6F<br />

9.0<br />

10.0<br />

FDT112KXE6F<br />

11.2<br />

12.5<br />

Hi:40 Me:37 Lo:35<br />

FDT140KXE6F<br />

14.0<br />

16.0<br />

FDT160KXE6F<br />

16.0<br />

18.0<br />

Hi:42 Me:40 Lo:37 Hi:43 Me:41 Lo:38<br />

Unit:298x840x840 Panel:35x950x950<br />

Unit:22 Panel:5.5 Unit:24 Panel:5.5 Unit:27 Panel:5.5<br />

Hi:18 Me:16 Lo:14<br />

Hi:27 Me:24 Lo:20<br />

Hi:30 Me:27 Lo:23<br />

Possible<br />

T-PSA-3BW-E<br />

Pocket Plastic net x1 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-T-36W-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

1 Phase 220-240V, 50Hz<br />

0.04-0.04 0.08-0.08<br />

0.04-0.04 0.08-0.08<br />

0.15-0.15<br />

0.15-0.15<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDT28/36/45 37dB(A), FDT56 39dB(A), FDT71 46dB(A), FDT90/112/140/160 51dB(A). <strong>Air</strong> flow: FDT28/36/45/56 20CMM, FDT71 28CMM, FDT90/112/140/160 37CMM.<br />

50


Dimensions<br />

All measurements in mm.<br />

FDT28KXE6F, 36KXE6F, 45KXE6F, 56KXE6F, 71KXE6F<br />

FDT90KXE6F, 112KXE6F, 140KXE6F, 160KXE6F<br />

51


R410A<br />

Ceiling Cassette -4way Compact (600x600mm)-<br />

FDTC<br />

Model No.<br />

FDTC22KXE6F<br />

FDTC28KXE6F<br />

FDTC36KXE6F<br />

FDTC45KXE6F<br />

FDTC56KXE6F<br />

Fits into standard<br />

600 x 600 ceiling<br />

Remote control (option)<br />

Wired<br />

RC-EX1A<br />

RC-E5<br />

RCH-E3<br />

Wireless<br />

RCN-TC-24W-ER<br />

Specifications<br />

Taking OA (Outside <strong>Air</strong>) into inside<br />

OA Spacer TC-OAS-E (option)<br />

Joint Duct TC-OAD-E (option)<br />

Utilizing OA spacer which comes as optional equipment, outside air<br />

can be taken into inside.<br />

Using 1 joint duct:<br />

OA comes up to 1.3m 3 /min.<br />

Using 2 joint ducts:<br />

OA comes from 1.3 to<br />

2.6m 3 /min.<br />

OA Spacer<br />

Individual flap control <strong>system</strong><br />

Ceiling<br />

surface<br />

According to room temperature conditions, four directions of air flow<br />

can be controlled by individual flap as preferred.<br />

As individual flap control is available even after installation,<br />

installation area became wider than before.<br />

OA<br />

Indoor Unit FDTC<br />

Panel<br />

300mm<br />

OA<br />

Joint Duct<br />

Quiet operation (Sound level in the Lo mode.)<br />

(dB) 36<br />

35<br />

34<br />

33<br />

32<br />

31<br />

30<br />

29<br />

28<br />

27<br />

26<br />

25<br />

(dB) 40<br />

39<br />

38<br />

37<br />

36<br />

35<br />

34<br />

33<br />

32<br />

31<br />

30<br />

29<br />

28<br />

27<br />

26<br />

25<br />

32<br />

dB<br />

KX4<br />

(Cooling/Heating)<br />

36<br />

dB<br />

KX4<br />

(Cooling/Heating)<br />

Flap control <strong>system</strong><br />

2dB<br />

Down<br />

30<br />

dB<br />

KX6<br />

(Cooling)<br />

32<br />

dB<br />

KX6<br />

(Heating)<br />

FDTC22KX, 28KX<br />

5dB<br />

Down<br />

31<br />

dB<br />

KX6<br />

(Cooling)<br />

FDTC45KX<br />

2dB<br />

Down<br />

34<br />

dB<br />

KX6<br />

(Heating)<br />

Selection of flap position is<br />

possible. Individual flaps can be<br />

set at different angles.<br />

RCH-E3 is not applicable to the Individual flap<br />

*<br />

control <strong>system</strong> and the Flap control <strong>system</strong>.<br />

(dB) 36<br />

35<br />

34<br />

33<br />

32<br />

31<br />

30<br />

29<br />

28<br />

27<br />

26<br />

25<br />

(dB) 40<br />

39<br />

38<br />

37<br />

36<br />

35<br />

34<br />

33<br />

32<br />

31<br />

30<br />

29<br />

28<br />

27<br />

26<br />

25<br />

34<br />

dB<br />

KX4<br />

(Cooling/Heating)<br />

39<br />

dB<br />

KX4<br />

(Cooling/Heating)<br />

Upper<br />

position<br />

3dB<br />

Down<br />

31<br />

dB<br />

KX6<br />

(Cooling)<br />

FDTC36KX<br />

8dB<br />

Down<br />

31<br />

dB<br />

KX6<br />

(Cooling)<br />

FDTC56KX<br />

Movable<br />

range<br />

Lower<br />

position<br />

34<br />

dB<br />

KX6<br />

(Heating)<br />

5dB<br />

Down<br />

34<br />

dB<br />

KX6<br />

(Heating)<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Sound pressure<br />

level<br />

Cooling<br />

Heating<br />

Exterior dimensions<br />

H x W x D<br />

kW<br />

kW<br />

kW<br />

Cooling<br />

dB(A)<br />

Heating<br />

Net weight<br />

Cooling<br />

<strong>Air</strong> flow<br />

Heating<br />

Outside air intake<br />

Panel<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Model<br />

mm<br />

kg<br />

CMM<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDTC22KXE6F<br />

2.2<br />

2.5<br />

Hi:35 Me:33 Lo:30<br />

Hi:35 Me:33 Lo:32<br />

Unit:14 Panel:3.5<br />

Hi:9.5 Me:8.5 Lo:7<br />

Hi:9.5 Me:8.5 Lo:8<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

FDTC28KXE6F<br />

2.8<br />

3.2<br />

0.03-0.03<br />

0.03-0.03<br />

FDTC36KXE6F<br />

3.6<br />

4.0<br />

1 Phase 220-240V, 50Hz<br />

Hi:38 Me:36 Lo:31<br />

Hi:38 Me:36 Lo:34<br />

Unit:248x570x570 Panel:35x700x700<br />

Hi:10 Me:9 Lo:7<br />

Hi:10 Me:9 Lo:8<br />

FDTC45KXE6F<br />

4.5<br />

5.0<br />

Hi:40 Me:37 Lo:31<br />

Hi:40 Me:37 Lo:34<br />

Unit:15 Panel:3.5<br />

Hi:11 Me:9 Lo:7<br />

Hi:11 Me:9 Lo:8<br />

Not possible<br />

TC-PSA-25W-E<br />

Pocket Plastic net x1 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TC-24W-ER<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

0.05-0.05<br />

0.05-0.05<br />

FDTC56KXE6F<br />

5.6<br />

6.3<br />

Hi:45 Me:39 Lo:31<br />

Hi:45 Me:39 Lo:34<br />

Hi:13 Me:10 Lo:7<br />

Hi:13 Me:10 Lo:8<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDTC22/28 44dB(A), FDTC36 46dB(A), FDTC45 48dB(A), FDTC56 49dB(A). <strong>Air</strong> flow: FDTC22/28 12CMM, FDTC36 13CMM, FDTC45 15CMM. FDTC56 16CMM.<br />

52


Dimensions<br />

All measurements in mm.<br />

Ultra slim design at just 248mm above the ceiling<br />

Condensate drain pump included as standard<br />

53


R410A<br />

Ceiling Cassette -2way-<br />

FDTW<br />

Model No.<br />

FDTW28KXE6F<br />

FDTW45KXE6F<br />

FDTW56KXE6F<br />

FDTW71KXE6F<br />

FDTW90KXE6F<br />

FDTW112KXE6F<br />

FDTW140KXE6F<br />

NEW<br />

FDTW28~71<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-TW-E<br />

FDTW90~140<br />

750mm Drain Pump<br />

Drain can be discharged upward by 750mm from the<br />

ceiling surface close to the indoor unit.<br />

It allows a piping layout with a high degree of freedom<br />

depending on the installation location.<br />

Flexible hose<br />

750mm<br />

Installation workability<br />

Drainage spout<br />

Drainage flow test can be<br />

done easily by use of this<br />

drainage spout.<br />

Transparent<br />

access hole to<br />

drain pan<br />

Dirt condition of the<br />

bottom of a drain pan can<br />

be checked through this<br />

transparent access hole<br />

without removing drain<br />

pan.<br />

A cross is visible<br />

invisible<br />

Cleaning<br />

not required<br />

Cleaning<br />

required<br />

Specifications<br />

A circumscribes<br />

circle is visible<br />

invisible<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

kW<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

mm<br />

FDTW28KXE6F<br />

2.8<br />

3.2<br />

0.09-0.09<br />

0.09-0.09<br />

Net weight<br />

<strong>Air</strong> flow<br />

kg<br />

CMM<br />

Unit:20 Panel:8.5<br />

Outside air intake<br />

Panel<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data Liquid line:ø6.35(1/4")<br />

Refrigerant piping size<br />

mm(in)<br />

Gas line:ø9.52(3/8")<br />

FDTW45KXE6F<br />

4.5<br />

5.0<br />

0.10-0.10<br />

0.10-0.10<br />

Hi:38 Me:34 Lo:31<br />

FDTW56KXE6F<br />

5.6<br />

6.3<br />

Unit:325x820x620 Panel:20x1120x680<br />

FDTW71KXE6F<br />

7.1<br />

8.0<br />

1 Phase 220-240V, 50Hz<br />

0.14-0.14<br />

0.14-0.14<br />

FDTW90KXE6F<br />

9.0<br />

10.0<br />

Unit:21 Panel:8.5<br />

Unit:23 Panel:8.5<br />

Hi:12 Me:10 Lo:9<br />

Possible<br />

TW-PSA-26W-E<br />

Pocket Plastic net x2 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TW-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

FDTW112KXE6F<br />

11.2<br />

12.5<br />

0.19-0.19<br />

0.19-0.19<br />

Hi:45 Me:41 Lo:37<br />

Unit:325x1535x620 Panel:20x1835x680<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

Unit:35 Panel:13<br />

Hi:27 Me:23 Lo:20<br />

TW-PSA-46W-E<br />

Pocket Plastic net x3 (Washable)<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDTW28/45/56/71 42dB(A), FDTW90/112/140 48dB(A). <strong>Air</strong> flow: FDTW28/45/56/71 14.5CMM, FDTW90/112/140 31CMM.<br />

FDTW140KXE6F<br />

14.0<br />

16.0<br />

54


Dimensions<br />

All measurements in mm.<br />

FDTW28KXE6F, 45KXE6F, 56KXE6F, 71KXE6F<br />

VP25 (I.D. 25, O.D. 32) Note(2)<br />

FDTW90KXE6F, 112KXE6F, 140KXE6F<br />

VP25 (I.D. 25, O.D. 32) Note(2)<br />

55


R410A<br />

Ceiling Cassette -1way-<br />

FDTS<br />

Model No.<br />

FDTS45KXE6F<br />

FDTS71KXE6F<br />

NEW<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-TS-E<br />

600mm Drain Pump<br />

Drain can be discharged upward by 600mm from the<br />

ceiling surface close to the indoor unit.<br />

It allows a piping layout with a high degree of freedom<br />

depending on the installation location.<br />

Compact design<br />

Indoor unit size (W:1,150 x D:565) brings easy installation<br />

for 1,200 x 600 ceiling and Panel size (1,250 x 650) is<br />

suitable for 1,200 x 600 ceiling. Height is the industry's<br />

lowest height level 220mm and weight is 27/28kg only.<br />

Flexible hose<br />

600mm<br />

220mm<br />

Specifications<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

kW<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow<br />

CMM<br />

Outside air intake<br />

Panel<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDTS45KXE6F<br />

4.5<br />

5.0<br />

0.04<br />

0.04<br />

Hi:40 Me:38 Lo:35<br />

Unit:27 Panel:5<br />

Hi:12 Me:11 Lo:9.5<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

1 Phase 220-240V, 50Hz<br />

Unit:220x1150x565 Panel:35x1250x650<br />

Possible<br />

TS-PSA-3AW-E<br />

Pocket Plastic net x2 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TS-E<br />

FDTS71KXE6F<br />

7.1<br />

8.0<br />

0.09<br />

0.09<br />

Hi:46 Me:41 Lo:36<br />

Unit:28 Panel:5<br />

Hi:15 Me:12 Lo:9.5<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDTS45 42dB(A), FDTS71 49dB(A). <strong>Air</strong> flow: FDTS45 13CMM, FDTS71 17CMM.<br />

56


Dimensions<br />

All measurements in mm.<br />

57


R410A<br />

Ceiling Cassette -1way Compact-<br />

FDTQ<br />

Model No.<br />

FDTQ22KXE6F<br />

FDTQ28KXE6F<br />

FDTQ36KXE6F<br />

Fits into standard<br />

600 x 600 ceiling<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-KIT3-E<br />

Compact design<br />

• Comfortable effective cooling for small rooms,<br />

with low fan speed air flow at just 5.4m 3 /min.<br />

Holes for<br />

tapping screws<br />

Fresh air<br />

opening<br />

for ducting<br />

(Knock out)<br />

or less Max.Drain up<br />

600<br />

210<br />

295~325<br />

63<br />

35 250<br />

285<br />

Specifications<br />

Optional wide panel shown for solid ceiling<br />

Condensate drain pump<br />

included as standard<br />

Ultra slim design at just 250mm above the ceiling<br />

Item<br />

Model FDTQ22KXE6F FDTQ28KXE6F FDTQ36KXE6F<br />

Panel Name<br />

Direct blow panel Duct panel Direct blow panel Duct panel Direct blow panel Duct panel<br />

Panel mode (Option) TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

kW<br />

kW<br />

2.2<br />

2.5<br />

2.8<br />

3.2<br />

3.6<br />

4.0<br />

Power source<br />

1 Phase 220-240V, 50Hz<br />

Power Cooling<br />

0.05-0.07<br />

0.05-0.07<br />

0.05-0.07<br />

consumption<br />

kW<br />

Heating<br />

0.05-0.07<br />

0.05-0.07<br />

0.05-0.07<br />

Sound pressure level dB(A) Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33 Hi:41 Me:38 Lo:33<br />

Exterior dimensions Unit<br />

250x570x570 250x570x570 250x570x570<br />

H x W x D<br />

mm<br />

Panel 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650<br />

Net weight<br />

kg Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3<br />

<strong>Air</strong> flow<br />

CMM Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5 Hi:7 Me:6 Lo:5<br />

Outside air intake<br />

Possible<br />

<strong>Air</strong> filter, Q’ty<br />

Pocket Plastic net x1 (Washable)<br />

Remote control(option)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDTQ22/38/36 45dB(A). <strong>Air</strong> flow: FDTQ22/38/36 8CMM.<br />

58


Dimensions<br />

All measurements in mm.<br />

Direct blow panel (TQ-PSA-15W-E)<br />

Direct blow panel (TQ-PSB-15W-E)<br />

Duct panel (QR-PNA-14W-ER)<br />

Duct panel (QR-PNB-14W-ER)<br />

*<br />

In case of Direct blow panel<br />

*<br />

Dimension Table<br />

Unit:mm<br />

model<br />

a b c d<br />

TQ-PSA-15W-E 625 514 650 580<br />

TQ-PSB-15W-E 780 514 650 580<br />

Dimension Table<br />

Unit:mm<br />

model<br />

a b c<br />

QR-PNA-14W-ER 625 650 580<br />

QR-PNB-14W-ER 780 650 580<br />

59


R410A<br />

Duct Connected -High Static Pressure-<br />

FDU<br />

Model No.<br />

FDU45KXE6F<br />

FDU56KXE6F<br />

FDU71KXE6F<br />

FDU90KXE6F<br />

FDU112KXE6F<br />

FDU140KXE6F<br />

FDU160KXE6F<br />

NEW<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-KIT3-E<br />

External Static Pressure(E.S.P) control<br />

You can set External Static Pressure (E.S.P.) by method of<br />

manual setting on remote control. Indoor unit will control<br />

fan-speed to keep rated air flow volume at each fan speed<br />

setting. You can set required E.S.P. by wired remote<br />

control that calculated with the set air flow rate and<br />

pressure loss of the duct connected.<br />

RC-E5<br />

E.S.P. button<br />

External Static Pressure (E.S.P.) can<br />

be set by E.S.P. button.<br />

Thin design<br />

Current New<br />

FDU71KXE6F 297 280 17mm less!!<br />

FDU112/140KXE6F 350 280 70mm less!!<br />

Reduction of weight<br />

Duct<br />

New<br />

FDU<br />

Duct<br />

Longer Duct<br />

Setting No.<br />

E.S.P.<br />

No.8<br />

80Pa<br />

No.9<br />

90Pa<br />

No.10<br />

Specifications<br />

Ceiling<br />

No.11<br />

No.12<br />

case1<br />

No.13<br />

Keep the same<br />

air flow volume<br />

No.14<br />

No.15<br />

100Pa 110Pa 120Pa 130Pa 140Pa 150Pa<br />

*Range of 80~150 Pa is set at ex-factory default.<br />

Range of 10~200 Pa is available by setting SW8-4 switch on at site.<br />

<br />

Current<br />

New<br />

10~130Pa 10~200Pa<br />

case2<br />

Current New<br />

FDU71KXE6F 40 34 6kg less!!<br />

FDU90KXE6F 63 34 29kg less!!<br />

FDU112/140KXE6F 63 54 9kg less!!<br />

Reduction of sound pressure level<br />

Current<br />

New<br />

(FDU71KXE6F, in the Lo mode)<br />

12dB(A) less!!<br />

0 5 10 15 20 25 30 35 40 dB(A)<br />

Current New<br />

Lo mode<br />

FDU90KXE6F 37 25 12dB(A) less!!<br />

FDU112KXE6F 38 30 8dB(A) less!!<br />

FDU140KXE6F 39 29 10dB(A) less!!<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

kW<br />

kW<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

Model<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow (Standard) CMM<br />

External Static pressure Pa<br />

Outside air intake<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDU45KXE6F FDU56KXE6F FDU71KXE6F FDU90KXE6F FDU112KXE6F<br />

4.5<br />

5.0<br />

5.6<br />

6.3<br />

7.1<br />

8.0<br />

9.0<br />

10.0<br />

11.2<br />

12.5<br />

1 Phase 220-240V, 50Hz<br />

0.10-0.10/0.10<br />

0.10-0.10/0.10<br />

Hi:32 Me:29 Lo:26<br />

280x750x635<br />

29 34 54<br />

Hi:10 Me:9 Lo:8<br />

200 (at 13CMM)<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

0.24-0.25/0.24<br />

0.24-0.25/0.24<br />

Hi:33 Me:29 Lo:25<br />

280x950x635<br />

Hi:19 Me:15 Lo:10<br />

200 (at 24CMM)<br />

0.31-0.32/0.31<br />

0.31-0.32/0.32<br />

Hi:38 Me:36 Lo:30<br />

Hi:28 Me:25 Lo:19<br />

200 (at 36CMM)<br />

Possible<br />

Procure locally<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

FDU140KXE6F<br />

14.0<br />

16.0<br />

0.35-0.36/0.35<br />

0.35-0.36/0.35<br />

Hi:40 Me:34 Lo:29<br />

280x1370x740<br />

Hi:32 Me:26 Lo:20<br />

200 (at 39CMM)<br />

FDU160KXE6F<br />

16.0<br />

18.0<br />

0.42-0.43/0.42<br />

0.42-0.43/0.42<br />

Hi:40 Me:35 Lo:30<br />

Hi:35 Me:28 Lo:22<br />

200 (at 48CMM)<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. External static<br />

pressure of indoor unit is 60Pa.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. Powerful-Hi can be selected. Sound pressure level: FDU45/56 37dB(A), FDU71/90 38dB(A), FDU112 44dB(A), FDU140 45dB(A),FDU160 47dB(A). <strong>Air</strong> flow: FDU45/56 13CMM, FDU71/90 24CMM, FDU112 36CMM, FDU140 39CMM,<br />

FDU160 48CMM.<br />

60


Dimensions<br />

All measurements in mm.<br />

FDU45KXE6F, 56KXE6F<br />

FDU71KXE6F, 90KXE6F<br />

FDU112KXE6F, 140KXE6F, 160KXE6F<br />

61


R410A<br />

Duct Connected -High Static Pressure-<br />

FDU<br />

Model No.<br />

FDU224KXE6F<br />

FDU280KXE6F<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-KIT3-E<br />

Fan control kit (option)<br />

(100~200Pa)<br />

U-FCRA<br />

Adaptability to higher static pressures<br />

High static pressure of 200Pa<br />

Control box<br />

Slide type fan <strong>system</strong><br />

Thin type duct connection<br />

opening<br />

Fan motor<br />

High static pressure<br />

silent fan<br />

Specifications<br />

Item<br />

Model FDU224KXE6F FDU280KXE6F<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

kW<br />

kW<br />

22.4<br />

25.0<br />

28.0<br />

31.5<br />

Power source<br />

1 Phase 220-240V, 50Hz<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow (Standard) CMM<br />

External Static pressure Pa<br />

Outside air intake<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

0.94-1.03<br />

0.86-0.90<br />

Hi:51<br />

Hi:51<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø19.05(3/4")<br />

360x1570x830<br />

92<br />

200<br />

Possible(on Return duct)<br />

Procure locally<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

0.96-1.05<br />

0.88-0.96<br />

Hi:52<br />

Hi:68<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø22.22(7/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. External static<br />

pressure of indoor unit is 100Pa.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. Values of sound pressure level become increased 5dB(A), when external static pressure is 200Pa (factory setting).<br />

4. Values of air flow volume are those at external static pressure 200Pa (factory setting).<br />

62


Dimensions<br />

All measurements in mm.<br />

VIEW A<br />

VIEW A<br />

63


R410A<br />

Duct Connected -Low/Middle Static Pressure-<br />

FDUM<br />

Model No.<br />

FDUM22KXE6F<br />

FDUM28KXE6F<br />

FDUM36KXE6F<br />

FDUM45KXE6F<br />

FDUM56KXE6F<br />

FDUM71KXE6F<br />

FDUM90KXE6F<br />

FDUM112KXE6F<br />

FDUM140KXE6F<br />

FDUM160KXE6F<br />

NEW<br />

Filter kit (option)<br />

UM-FL1E : for 22~56<br />

UM-FL2E : for 71, 90<br />

UM-FL3E : for 112, 140, 160<br />

Remote control (option)<br />

Wired<br />

Wireless<br />

Filter pressure loss:5pa<br />

*<br />

RC-EX1A<br />

RC-E5<br />

RCH-E3<br />

RCN-KIT3-E<br />

Improvement of low tap noise dB(A)<br />

<strong>Air</strong> flow sound was reduced by new fan and casing design.<br />

Refrigerant flow sound was decreased by advanced refrigerant distributor design.<br />

Indoor model name 22/28/36 45/56 71 90 112 140<br />

NEW 26 26 25 25 30<br />

Current FDUM dB(A) 28 29 29 30 32 33<br />

Improvement 2 3 4 5 2 4<br />

29<br />

Thin design<br />

The height of all FDUM models is only 280mm.<br />

70mm less<br />

H 350<br />

H 280<br />

FDUM112/140KXE6F<br />

Improvement of the serviceability<br />

19mm less<br />

Fan unit (impeller and motor) can be pulled out<br />

from the right side or the bottom side of the unit.<br />

Maintenance can be available from the right side<br />

or the bottom side.<br />

Maintenance<br />

hole<br />

Service<br />

space<br />

Unit<br />

Pipe<br />

Fan unit<br />

H 299<br />

H 280<br />

FDUM22~90KXE6F<br />

Specifications<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

kW<br />

kW<br />

Power source<br />

Power Cooling<br />

consumption<br />

kW<br />

Heating<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

mm<br />

Net weight<br />

<strong>Air</strong> flow<br />

External<br />

Static pressure<br />

Outside air intake<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Model<br />

kg<br />

CMM<br />

Pa<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDUM22KXE6F FDUM28KXE6F FDUM36KXE6F FDUM45KXE6F FDUM56KXE6F FDUM71KXE6F FDUM90KXE6F FDUM112KXE6F FDUM140KXE6F<br />

2.2<br />

2.5<br />

2.8<br />

3.2<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

3.6<br />

4.0<br />

0.10-0.10<br />

0.10-0.10<br />

Hi:32 Me:29 Lo:26<br />

4.5<br />

5.0<br />

(mm)<br />

5.6<br />

6.3<br />

7.1<br />

8.0<br />

9.0<br />

10.0<br />

1 Phase 220-240V, 50Hz<br />

0.20-0.20<br />

0.20-0.20<br />

Hi:33 Me:29 Lo:25<br />

29 34<br />

Hi:10 Me:9 Lo:8<br />

Hi:19 Me:15 Lo:10<br />

100<br />

100(at 13CMM)<br />

(at 24CMM)<br />

Possible<br />

Procure locally<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

11.2<br />

12.5<br />

14.0<br />

16.0<br />

0.29-0.29 0.33-0.33 0.45-0.45<br />

0.29-0.29 0.33-0.33 0.45-0.45<br />

Hi:38 Me:36 Lo:30 Hi:40 Me:34 Lo:29 Hi:40 Me:35 Lo:30<br />

280 x 750 x 635 280 x 950 x 635<br />

280 x 1370 x 740<br />

54<br />

Hi:28 Me:25 Lo:19 Hi:32 Me:26 Lo:20 Hi:35 Me:28 Lo:22<br />

100<br />

(at 36CMM)<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

100<br />

(at 39CMM)<br />

FDUM160KXE6F<br />

16.0<br />

18.0<br />

100<br />

(at 48CMM)<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. External static<br />

pressure of indoor unit is 35Pa(22/28/36/45/56/71/90), 60Pa(112/140/160).<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDUM22/28/36/45/56 37dB(A), FDUM71/90 38dB(A), FDUM112 44dB(A), FDUM140 45dB(A), FDUM160 47dB(A). <strong>Air</strong> flow: FDUM22/28/36/45/56 13CMM, FDUM71/90 24CMM,<br />

FDUM112 36CMM, FDUM140 39CMM, FDUM160 48CMM.<br />

64


Dimensions<br />

All measurements in mm.<br />

FDUM22KXE6F, 28KXE6F, 36KXE6F, 45KXE6F, 56KXE6F<br />

FDUM71KXE6F, 90KXE6F<br />

FDUM112KXE6F, 140KXE6F, 160KXE6F<br />

65


R410A<br />

Duct Connected (thin) -Low Static Pressure-<br />

FDUT<br />

Model No.<br />

FDUT15KXE6F-E<br />

FDUT22KXE6F-E<br />

FDUT28KXE6F-E<br />

FDUT36KXE6F-E<br />

FDUT45KXE6F-E<br />

FDUT56KXE6F-E<br />

FDUT71KXE6F-E<br />

Expansion of lineup<br />

NEW<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-KIT3-E<br />

15KXE6F-E 22KXE6F-E 28KXE6F-E 36KXE6F-E 45KXE6F-E 56KXE6F-E 71KXE6F-E<br />

Current<br />

New<br />

*<br />

FOUT15KXE6F-E:Suitable for small divided rooms<br />

FOUT71KXE6F-E:Suitable for large rooms<br />

*Comming soon<br />

(1) Can not be connected to some KX outdoor units. Please consult your dealer for further details.<br />

(2) Regarding pipe length (150m or more is required) and temperature condition (the lowest is 10ºC) in the cooling operation etc. , please refer to our technical manual.<br />

Option<br />

Item Contents for FDUT15/22/28/36KXE6F-E for FDUT45/56KXE6F-E for FDUT71KXE6F-E<br />

Duct kit (out)<br />

1<br />

UT-SAT1EF<br />

UT-SAT2EF<br />

UT-SAT3EF<br />

Filter set<br />

2 + 3<br />

UT-FL1EF<br />

UT-FL2EF<br />

UT-FL3EF<br />

Filter pressure loss : 5 Pa<br />

2<br />

Duct kit (in)<br />

1 Duct kit (out)<br />

Specifications<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

Sound pressure level 1<br />

Sound pressure level 2<br />

Model<br />

kW<br />

kW<br />

kW<br />

dB(A)<br />

dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow (Standard) CMM<br />

External Static pressure Pa<br />

Outside air intake<br />

Suction guard(<strong>Air</strong> filter)<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDUT15KXE6F-E<br />

1.5<br />

1.7<br />

0.06-0.06/0.06<br />

0.06-0.06/0.06<br />

Hi:28 Me:26 Lo:22<br />

Hi:32 Me:29 Lo:25<br />

FDUT22KXE6F-E<br />

2.2<br />

2.5<br />

0.07-0.07<br />

0.07-0.07<br />

Hi:28 Me:26 Lo:22<br />

Hi:32 Me:29 Lo:26<br />

200x750x500<br />

FDUT28KXE6F-E FDUT36KXE6F-E FDUT45KXE6F-E FDUT56KXE6F-E FDUT71KXE6F-E<br />

2.8<br />

3.2<br />

3.6<br />

4.0<br />

4.5<br />

5.0<br />

5.6<br />

6.0<br />

7.1<br />

8.0<br />

1 Phase 220-240V, 50Hz<br />

0.08-0.08<br />

0.08-0.08<br />

Hi:33 Me:30 Lo:26<br />

Hi:37 Me:34 Lo:28<br />

Hi:34 Me:32 Lo:28<br />

Hi:36 Me:33 Lo:27<br />

200x950x500<br />

Hi:35 Me:33 Lo:30<br />

Hi:38 Me:33 Lo:29<br />

0.08-0.08<br />

0.07-0.07<br />

Hi:35 Me:31 Lo:28<br />

Hi:41 Me:37 Lo:32<br />

220x1150x565<br />

21 22<br />

25<br />

31<br />

Hi:6 Me:5 Lo:4 Hi:7.5 Me:6 Lo:5<br />

Hi:8.5 Me:7 Lo:5.5 Hi:11.5 Me:9 Lo:7 Hi:12.5 Me:9 Lo:7.2 Hi:16 Me:13 Lo:9.5<br />

Standard:10, Max:35<br />

Standard:10, Max:50<br />

Not possible<br />

Procure locally<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. External static<br />

pressure of indoor unit is 10Pa.<br />

2. The data of nominal cooling and heating capacity and sound pressure level are measured with 10Pa of external static pressure.<br />

3. The sound level indicates the value of rear-intake type with duct in anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

4. Sound pressure levels are values when 2m supply duct and 1m return duct are connected.<br />

1 : Mike position is 1.5m below unit, 2 : Mike position is 1m in front and 1m below the air supply duct.<br />

3<br />

Filter<br />

66


Dimensions<br />

All measurements in mm.<br />

FDUT15KXE6F-E, 22KXE6F-E, 28KXE6F-E, 36KXE6F-E<br />

15,22,28<br />

FDUT45KXE6F-E, 56KXE6F-E<br />

FDUT71KXE6F-E<br />

67


R410A<br />

Duct Connected (Compact & Flexible)<br />

FDUH<br />

Remote control (option)<br />

Wired<br />

Model No.<br />

FDUH22KXE6F<br />

FDUH28KXE6F<br />

FDUH36KXE6F<br />

Drain up kit (option)<br />

(600mm)<br />

UH-DU-E<br />

RC-EX1A RC-E5<br />

Wireless<br />

RCN-KIT3-E<br />

RCH-E3<br />

Filter kit (option)<br />

UH-FL1E<br />

Compact and thin size, light weight<br />

Quiet operation<br />

Our leading high technology has realized the<br />

best solution for air conditioning in hotels with<br />

compact and thin size units and high energy<br />

efficiency. In addition, weight is only 20kg.<br />

257<br />

mm<br />

570mm<br />

* Filter pressure loss:5pa Liquid line:ø6.35(1/4")<br />

The lowest sound level in the industry can ensure<br />

comfortable stay and rest in hotels.<br />

530mm<br />

Installation Flexibility<br />

Control box and drain piping can be installed on both side of the unit and air intake<br />

to the unit is available from bottom or back side. Our highest technology can satisfy<br />

diverse installation requirements.<br />

Control box<br />

Wired remote control<br />

RCH-E3<br />

(option)<br />

Simple remote control<br />

Considering specialized<br />

usage in hotel rooms,<br />

control buttons are limited<br />

only to minimum required<br />

functions such as ON/OFF,<br />

mode, temperature setting<br />

and fan speed. It is really<br />

simple and easy to use.<br />

Specifications<br />

Drain piping<br />

Item<br />

Model FDUH22KXE6F FDUH28KXE6F FDUH36KXE6F<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

kW<br />

kW<br />

2.2<br />

2.5<br />

2.8<br />

3.2<br />

3.6<br />

4.0<br />

Power source<br />

1 Phase 220-240V, 50Hz<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions HxWxD mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow<br />

CMM<br />

External static pressure Pa<br />

Outside air intake<br />

<strong>Air</strong> filter, Q'ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

0.05-0.07<br />

0.05-0.07<br />

HI: 33 Me: 30 Lo: 27<br />

257x570x530<br />

22<br />

HI: 7 Me: 6.5 Lo: 6<br />

30<br />

Not possible<br />

Procure locally<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

Gas line:ø12.7(1/2")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDUH22/28/36 39dB(A). <strong>Air</strong> flow: FDUH22/28/36 8.5CMM.<br />

68


Dimensions<br />

All measurements in mm.<br />

30.8<br />

12-ø4<br />

Holes for<br />

tapping screws<br />

53<br />

32<br />

27.6<br />

150 150 150 32<br />

494 27.6<br />

(Duct dimension)<br />

32.5 100 32.5<br />

145 83.3<br />

(Duct dimension)<br />

Supply air duct<br />

Symbol<br />

A<br />

B<br />

M o d e l<br />

Gas piping<br />

C o n t e n t<br />

FDUH22KXE6F,28KXE6F<br />

ø9.52 (3/8") (Flare)<br />

ø6.35 (1/4") (Flare)<br />

Liquid piping<br />

C1,C2 Drain piping<br />

VP20(I.D.20, O.D.26) Note (2)<br />

D<br />

E<br />

Hole for wiring<br />

Suspension bolts<br />

ø30<br />

(M10)<br />

F Inspection hole (635X890) Note (3)<br />

FDUH36KXE6F<br />

ø12.7 (1/2") (Flare)<br />

30.8<br />

C1<br />

145.6<br />

<strong>Air</strong><br />

outlet<br />

66<br />

95.3<br />

Drain hose piece<br />

(Standard Accessory)<br />

(Installed on site)<br />

Note(4)<br />

273<br />

66.4<br />

575.2<br />

(Suspension bolts pitch)<br />

21<br />

40<br />

255.8<br />

30.8<br />

Space for installation and service<br />

F<br />

66<br />

A<br />

B<br />

156.8<br />

Control box<br />

Note(4)<br />

62.1<br />

488<br />

(Suspension bolts pitch)<br />

530<br />

C2<br />

610<br />

890<br />

600 100<br />

<strong>Air</strong><br />

inlet<br />

(D)<br />

68<br />

21<br />

Unit:mm<br />

188.5<br />

148.5<br />

12-ø4<br />

Holes for<br />

tapping screws<br />

37.6<br />

D<br />

38.2<br />

32<br />

27.5<br />

549.2<br />

<strong>Air</strong> inlet<br />

150 150 150 32<br />

494.2 27.5<br />

574<br />

E<br />

30 160 30<br />

28.3 200<br />

Notes<br />

( 1 ) The model name label is attached on the fan case<br />

inside the air return grille.<br />

( 2 ) Prepare the connecting socket (VP20) on site.<br />

(As for drain piping, it is possible to choose C1 or C2)<br />

( 3 ) When control box is located on the reverse side, Installation<br />

space should be modified to new location.<br />

( 4 ) Contorl box and Drain hose piece are able to be relocated<br />

on the reverse side.<br />

G<br />

Bottom plate<br />

(Able to be located on the back side)<br />

View G<br />

In case of Bottom air intake<br />

50.5 150 150 150 50.5<br />

12-ø4<br />

Holes for<br />

tapping screws<br />

18.2 537.6<br />

<strong>Air</strong> inlet<br />

160 30<br />

198.2<br />

30<br />

28.5<br />

Simple remote control<br />

120<br />

70<br />

15<br />

View G<br />

(After bottom plate is replaced to back side)<br />

69


R410A<br />

Wall Mounted<br />

FDK<br />

Remote control (option)<br />

Wired<br />

Model No.<br />

FDK22KXE6F<br />

FDK28KXE6F<br />

FDK36KXE6F<br />

FDK45KXE6F<br />

FDK56KXE6F<br />

FDK71KXE6F<br />

FDK22~56<br />

RC-EX1A<br />

Wireless<br />

RC-E5<br />

RCH-E3<br />

RCN-K-E : FDK22~56<br />

RCN-K71-E : FDK71<br />

FDK71<br />

Innovative Design<br />

Installation Workability<br />

New FDK models adopt the air<br />

flow design that's proven to<br />

minimise resistance in a CFD<br />

analysis to achieve uniform air<br />

conditioning to the furthest<br />

corners of the room.<br />

259<br />

The new slimmer design allows<br />

easy & neat installation even in tight<br />

spaces.<br />

Specifications<br />

Fast<br />

Slow<br />

Colors in the figure show the air speed.<br />

Flap control <strong>system</strong><br />

Selection of flap position is<br />

possible. A flap can be set at<br />

different angles.<br />

RCH-E3 is not applicable to the Flap control <strong>system</strong>.<br />

*<br />

Upper<br />

position<br />

Movable<br />

range<br />

Lower<br />

position<br />

Improved Maintainability<br />

Also included is a new easy clean mechanism where the front<br />

panel is opened/closed simply from the bottom to easily access<br />

the detachable filters.<br />

Item<br />

Model FDK22KXE6F FDK28KXE6F FDK36KXE6F FDK45KXE6F FDK56KXE6F FDK71KXE6F<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

kW<br />

kW<br />

2.2<br />

2.5<br />

2.8<br />

3.2<br />

3.6<br />

4.0<br />

4.5<br />

5.0<br />

5.6<br />

6.3<br />

7.1<br />

8.0<br />

Power source<br />

1 Phase 220-240V, 50Hz<br />

Power<br />

consumption<br />

Sound pressure<br />

level<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Exterior dimensions<br />

H x W x D<br />

kW<br />

dB(A)<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow<br />

CMM<br />

Outside air intake<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

Hi:35 Me:33 Lo:31<br />

Hi:35 Me:33 Lo:31<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

0.05<br />

0.04<br />

Hi:41 Me:35 Lo:31<br />

Hi:39 Me:35 Lo:31<br />

Hi:42 Me:37 Lo:33<br />

Hi:42 Me:37 Lo:33<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

Hi:46 Me:42 Lo:37<br />

Hi:46 Me:42 Lo:37<br />

0.09<br />

0.09<br />

Hi:47 Me:43 Lo:39<br />

Hi:47 Me:43 Lo:39<br />

298 x 840 x 259 318 x 1098 x 248<br />

12 12.5 13<br />

15.5<br />

Hi:8 Me:7 Lo:6<br />

Hi:10 Me:9 Lo:7 Hi:11 Me:9 Lo:7 Hi:14 Me:12 Lo:10 Hi:21 Me:18 Lo:15<br />

Not possible<br />

Polypropylene net x2 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-K-E (for FDK22~56), RCN-K71-E (for FDK71)<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

0.05<br />

0.05<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

Powerful-Hi can be selected. Sound pressure level: FDK22/28 38dB(A), FDK36 48dB(A)(Cooling)&42dB(A)(Heating), FDK45 48dB(A)(Cooling)&43dB(A)(Heating), FDK56 48dB(A)(Cooling)&47dB(A)(Heating), FDK71 48dB(A).<br />

<strong>Air</strong> flow: FDK22/28 11CMM, FDK36/45 15CMM, FDK56 16CMM, FDK71 24CMM.<br />

70


Dimensions<br />

All measurements in mm.<br />

FDK22KXE6F, 28KXE6F, 36KXE6F, 45KXE6F, 56KXE6F<br />

FDK71KXE6F<br />

71


R410A<br />

Ceiling Suspended<br />

FDE<br />

Model No.<br />

FDE36KXE6F<br />

FDE45KXE6F<br />

FDE56KXE6F<br />

FDE71KXE6F<br />

FDE112KXE6F<br />

FDE140KXE6F<br />

•<br />

•<br />

•<br />

•<br />

Small<br />

Light-weight<br />

Quiet<br />

Sleek, intelligent design<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-E-E<br />

Flap control <strong>system</strong><br />

Selection of flap<br />

position is possible.<br />

A flap can be set at<br />

different angles.<br />

RCH-E3 is not applicable to<br />

*<br />

the Flap control <strong>system</strong>.<br />

Upper<br />

position<br />

Movable<br />

range<br />

Lower<br />

position<br />

New Slim Design<br />

210mm<br />

Slim and sleek design starting at just 28kgs in weight means quick,<br />

easy & neat installation.<br />

Installation Workability<br />

Up<br />

Rear<br />

Right<br />

Specifications<br />

Refrigerant piping can be routed in three directions (rear, up, right)<br />

& drain piping in left or right directions, allowing free layout to meet<br />

installation conditions.<br />

Item<br />

Model FDE36KXE6F FDE45KXE6F FDE56KXE6F FDE71KXE6F FDE112KXE6F FDE140KXE6F<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

kW<br />

kW<br />

3.6<br />

4.0<br />

4.5<br />

5.0<br />

5.6<br />

6.3<br />

7.1<br />

8.0<br />

11.2<br />

12.5<br />

14.0<br />

16.0<br />

Power source<br />

1 Phase 220-240V, 50Hz<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

Sound pressure level<br />

Exterior dimensions<br />

H x W x D<br />

kW<br />

dB(A)<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow<br />

CMM<br />

Outside air intake<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

0.05-0.06<br />

0.05-0.06<br />

Hi:39 Me:38 Lo:36<br />

28 37 49<br />

Hi:10 Me:9 Lo:7<br />

Hi:16 Me:14 Lo:12 Hi:26 Me:23 Lo:21<br />

Not possible<br />

Pocket Plastic net x2 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-E-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

0.10-0.11<br />

0.09-0.10<br />

Hi:41 Me:39 Lo:37<br />

0.14-0.16<br />

0.13-0.15<br />

Hi:44 Me:41 Lo:39<br />

210 x 1070 x 690 210 x 1320 x 690<br />

250 x 1620 x 690<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

Powerful-Hi can be selected. Sound pressure level: FDE36/45/56 46dB(A), FDE71 50dB(A), FDE112 46dB(A), FDE140 50dB(A). <strong>Air</strong> flow: FDE36/45/56 11CMM, FDE71 18CMM, FDE112 28CMM, FDE140 32CMM.<br />

0.16-0.18<br />

0.15-0.17<br />

Hi:46 Me:44 Lo:43<br />

Hi:29 Me:26 Lo:23<br />

72


Dimensions<br />

All measurements in mm.<br />

C1,C2<br />

FDE36KXE6F, 45KXE6F, 56KXE6F<br />

24<br />

1022 (Suspension bolts pitch)<br />

24<br />

40 990<br />

40<br />

1070<br />

<strong>Air</strong> supply<br />

173<br />

210 5<br />

215<br />

290 (Suspension bolts pitch)<br />

135<br />

68<br />

410<br />

690<br />

D<br />

145<br />

52<br />

195<br />

235<br />

271<br />

53<br />

109<br />

B<br />

A<br />

C1,C2<br />

108<br />

27<br />

Drain hose piece (Accessory, 0.3m)<br />

(Installed on site)<br />

10<br />

Note) The slope of drain piping inside the<br />

unit must take decline of 10mm.<br />

40<br />

15<br />

20 100<br />

60<br />

53<br />

7<br />

27 31<br />

Symbol<br />

A<br />

B<br />

C 1,2<br />

D<br />

E<br />

F<br />

G<br />

Content<br />

Gas piping<br />

Liquid piping<br />

Drain piping<br />

Hole for suspension bolt<br />

Back cutout<br />

Top cutout<br />

Hole for drain piping (for left back)<br />

ø12.7 (1/2") (Flare)<br />

ø6.35 (1/4") (Flare)<br />

VP20 (I.D.20)<br />

(M10 or M8)<br />

PE cover<br />

Plate cover<br />

(Knock out)<br />

Space for installation and service<br />

20 120<br />

Position of top cutout and back cutout<br />

175 19<br />

Hole for<br />

drain piping<br />

(for left)<br />

C2<br />

76<br />

<strong>Air</strong> return grille<br />

A<br />

C1<br />

75<br />

110<br />

135<br />

308<br />

B<br />

100 or more<br />

300 or more<br />

150 or more<br />

5 or more<br />

Obstacle<br />

Make a space of 4000 or more between the units when installing more than one.<br />

F<br />

Right side cutout<br />

Remove the cutout using side cutter or similar tool.<br />

E<br />

G<br />

Note(1)The model name label is attached on the<br />

fan casing inside the air return grille.<br />

C1,C2<br />

FDE71KXE6F<br />

290 (Suspension bolts pitch)<br />

D<br />

10<br />

53<br />

24<br />

1272 (Suspension bolts pitch)<br />

40 1240<br />

1320<br />

24<br />

40<br />

<strong>Air</strong> supply<br />

173<br />

210 5<br />

215<br />

135<br />

68<br />

410<br />

690<br />

145<br />

52<br />

195<br />

235<br />

271<br />

53<br />

109<br />

B<br />

A<br />

C1,C2<br />

108<br />

27<br />

40<br />

15<br />

20 100<br />

Drain hose piece (Accessory, 0.3m)<br />

(Installed on site)<br />

Note)The slope of drain piping inside the<br />

unit must take decline of 10mm.<br />

60<br />

7<br />

27 31<br />

Symbol<br />

Content<br />

A Gas piping<br />

B Liquid piping<br />

C 1,2 Drain piping<br />

D Hole for suspension bolt<br />

E Back cutout<br />

F Top cutout<br />

G Hole for drain piping(for left back)<br />

ø15.88 (5/8") (Flare)<br />

ø9.52 (3/8") (Flare)<br />

VP20 (I.D.20)<br />

(M10 or M8)<br />

PE cover<br />

Plate cover<br />

(Knock out)<br />

Space for installation and service<br />

20<br />

Position of top cutout and back cutout<br />

120<br />

175 19<br />

Hole for<br />

drain piping<br />

(for left)<br />

C2<br />

76<br />

<strong>Air</strong> return grille<br />

A<br />

C1<br />

75<br />

110<br />

135<br />

308<br />

B<br />

100 or more<br />

300 or more<br />

150 or more<br />

5 or more<br />

Right side cutout<br />

F<br />

G<br />

E<br />

Obstacle<br />

Remove the cutout using side cutter or similar tool.<br />

Make a space of 4500 or more between the units when installing more than one.<br />

Note(1)The model name label is attached on the<br />

fan casing inside the air return grille.<br />

FDE112KXE6F, 140KXE6F<br />

290 (Suspension bolts pitch)<br />

D<br />

C1,C2<br />

10<br />

53<br />

24<br />

40<br />

1572 (Suspension bolts pitch)<br />

1540<br />

1620<br />

24<br />

40<br />

<strong>Air</strong> supply<br />

173<br />

250 5<br />

255<br />

135<br />

68<br />

410<br />

690<br />

145<br />

52<br />

195<br />

235<br />

271<br />

53<br />

109<br />

B<br />

A<br />

C1,C2<br />

108<br />

27<br />

40<br />

20<br />

Drain hose piece (Accessory, 0.3m)<br />

(Installed on site)<br />

Note) The slope of drain piping inside the<br />

unit must take decline of 10mm.<br />

15 60<br />

100<br />

7<br />

27 31<br />

Symbol<br />

A<br />

B<br />

C1,2<br />

D<br />

E<br />

F<br />

G<br />

Content<br />

Gas piping<br />

Liquid piping<br />

Drain piping<br />

Hole for suspension bolt<br />

Back cutout<br />

Top cutout<br />

Hole for drain piping (for left back)<br />

ø15.88 (5/8") (Flare)<br />

ø9.52 (3/8") (Flare)<br />

VP20 (I.D.20)<br />

(M10 or M8)<br />

PE cover<br />

Plate cover<br />

(Knock out)<br />

Space for installation and service<br />

Position of top cutout and back cutout<br />

Hole for<br />

drain piping<br />

(for left)<br />

120<br />

175 19<br />

20<br />

C2<br />

76<br />

<strong>Air</strong> return grille<br />

A<br />

C 1<br />

75<br />

110<br />

135<br />

308<br />

B<br />

100 or more<br />

300 or more<br />

150 or more<br />

5 or more<br />

Obstacle<br />

Make a space of 5000 or more between the units when installing more than one.<br />

F<br />

Right side cutout<br />

Remove the cutout using side cutter or similar tool.<br />

Note(1)The model name label is attached on the<br />

fan casing inside the air return grille.<br />

E<br />

G<br />

73


R410A<br />

Floor Standing -2way-<br />

FDFW<br />

Model No.<br />

FDFW28KXE6F<br />

FDFW45KXE6F<br />

FDFW56KXE6F<br />

Remote control (option)<br />

Wired<br />

Wireless<br />

RC-EX1A<br />

RC-E5<br />

RCH-E3<br />

RCN-FW-E<br />

Sophisticated Design<br />

With classy semi flat front panel in chic white, the new<br />

series fit in various kinds of rooms and create relaxing<br />

atmosphere. Choice of wall hanging, floor standing or<br />

behind gallery installation is available.<br />

Quiet Operation<br />

Thanks to optimum balance of air outlet direction and<br />

sufficient air flow volume, the sound level has been<br />

minimized. The level of FDFW28KXE6F in the cooling lo<br />

mode is 30dB(A) only.<br />

Flap control <strong>system</strong><br />

Selection of flap<br />

position is possible.<br />

A flap can be set at<br />

different angles.<br />

Movable<br />

range<br />

Upper<br />

position<br />

Convenient to use operation<br />

Simultaneous lower and upper air outlets or upper outlet<br />

can be selected by air flow direction button. Further<br />

control can be arranged by a remote control.<br />

RCH-E3 is not applicable to<br />

*<br />

the Flap control <strong>system</strong>.<br />

Lower<br />

position<br />

Specifications<br />

(In case of use of wireless remote control)<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

kW<br />

kW<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

Model<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow (Standard) CMM<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDFW28KXE6F<br />

2.8<br />

3.2<br />

0.02-0.02<br />

0.02-0.02<br />

Hi:36 Me:34 Lo:30<br />

19<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

Hi:9 Me:8 Lo:7<br />

FDFW45KXE6F<br />

4.5<br />

5.0<br />

1 Phase 220-240V, 50Hz<br />

0.02-0.02<br />

0.02-0.02<br />

Hi:38 Me:36 Lo:33<br />

600x860x238<br />

Polypropylene net x1 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-FW-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

FDFW56KXE6F<br />

5.6<br />

6.3<br />

0.03-0.03<br />

0.03-0.03<br />

Hi:44 Me:37 Lo:33<br />

Hi:11 Me:9 Lo:8<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

20<br />

74


Dimensions<br />

All measurements in mm.<br />

75


R410A<br />

Floor Standing (with casing)<br />

FDFL<br />

Floor Standing (without casing)<br />

FDFU<br />

Model No.<br />

FDFL71KXE6F<br />

Remote control (option)<br />

Wired<br />

RC-EX1A RC-E5 RCH-E3<br />

Wireless<br />

RCN-KIT3-E<br />

FDFU28KXE6F<br />

FDFU45KXE6F<br />

FDFU56KXE6F<br />

FDFU71KXE6F<br />

FDFL<br />

FDFU (concealed type)<br />

Compact design at 630mm height<br />

Wider airflow for optimum comfort<br />

Specifications<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

Power<br />

consumption<br />

Cooling<br />

Heating<br />

kW<br />

kW<br />

kW<br />

Sound pressure level dB(A)<br />

Exterior dimensions<br />

H x W x D<br />

Model<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow (Standard) CMM<br />

<strong>Air</strong> filter, Q’ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

FDFL71KXE6F<br />

7.1<br />

8.0<br />

0.09-0.10<br />

0.09-0.10<br />

Hi:43 Me:41 Lo:40<br />

630x1481x225<br />

FDFU28KXE6F<br />

2.8<br />

3.2<br />

Hi:41 Me:38 Lo:36<br />

FDFU45KXE6F<br />

4.5<br />

5.0<br />

1 Phase 220-240V, 50Hz<br />

0.09-0.10<br />

0.09-0.10<br />

FDFU56KXE6F<br />

5.6<br />

6.3<br />

Hi:43 Me:41 Lo:40<br />

FDFU71KXE6F<br />

7.1<br />

8.0<br />

40 25<br />

32<br />

Hi:18 Me:15 Lo:12<br />

Hi:12 Me:11 Lo:10<br />

Hi:14 Me:12 Lo:10<br />

Hi:18 Me:15 Lo:12<br />

Polypropylene net x1 (Washable)<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

630x1077x225<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

630x1362x225<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

76


Dimensions<br />

All measurements in mm.<br />

FDFL<br />

FDFU<br />

Dimension Table<br />

model<br />

FDFU28KXE6F, 45KXE6F, 56KXE6F<br />

FDFU71KXE6F<br />

Unit:mm<br />

a b c d e<br />

786 810 722<br />

1071 1095 1007<br />

750 806<br />

1035 1091<br />

77


R410A<br />

Outdoor <strong>Air</strong> Processing unit<br />

FDU-F<br />

Remote control (option)<br />

Wired<br />

Model No.<br />

FDU500FKXE6F<br />

FDU850FKXE6F<br />

FDU1300FKXE6F<br />

FDU1800FKXE6F<br />

RC-EX1A<br />

RC-E5<br />

Wireless<br />

RCH-E3<br />

Fan control kit (option)<br />

(100~200Pa)<br />

U-FCRB<br />

RCN-KIT3-E<br />

<strong>Air</strong> conditioning and intake of outdoor air are in the same <strong>system</strong><br />

Outdoor <strong>Air</strong> processing unit can<br />

be connected in a KX6 <strong>system</strong> as<br />

one of indoor unit series and can<br />

create fresh and comfortable air<br />

supply together from our high<br />

advanced technology.<br />

Outdoor <strong>Air</strong><br />

Processing unit<br />

indoor unit<br />

air<br />

conditioning<br />

indoor unit<br />

outside<br />

air supply<br />

office<br />

KX6 outdoor unit<br />

refresh room,<br />

corridor<br />

rest room<br />

Compact design<br />

Compact design at just 360mm in<br />

height, high static pressure of<br />

200Pa and the industry's lowest<br />

noise level can meet various kind<br />

of installation location for office,<br />

refresh room, restroom and<br />

kitchen of restaurant etc.<br />

exhaust air<br />

supply air<br />

outdoor air<br />

outdoor air<br />

supply air<br />

(1) This unit is the specific unit for processing the outdoor air temperature closer to the room temperature. For conditioning the room temperature a<br />

dedicated air-conditioner is required additionally.<br />

(2) This unit monitors the outdoor air temperature and controls thermostat ON/OFF at the setting temperature by the remote controller, which<br />

indicates the outdoor air temperature for controlling thermostat ON/OFF. When thermostat is turned OFF, the operation is changed to the fan mode<br />

so that unprocessed outdoor air will be blown into the room directly. Therefore place the air outlet port or orient the air outlet direction not to blow<br />

air directly to persons in the room, especially in the small room such as a restroom and/or sanitary hot water supplying room.<br />

(3) It is strictly prohibited to monitor the room temperature by switching to the thermistor at remote controller side and/or the optional remote<br />

thermistor. Otherwise dew formation at air outlet port and/or dew dripping may occur during cooling operation due to the lower outdoor air<br />

temperature. Therefore keep the remote controller of this unit in place closer to the administrator so as not to be touched it freely by the end user.<br />

(4) Dehumidifying operation with this unit is prohibited.<br />

(5) When handing over this unit to the end user, make sure to explain sufficiently about the foregoing cautions, the installation place and usage of<br />

remote control for this unit and the location of the air outlet.<br />

78


Connectivity with KX6 series<br />

FDU-F series are connectable to 8~48HP KX6 outdoor units, not connectable to 4~6HP.<br />

8 ~ 48 HP : Yes , 4 ~ 6 HP : No<br />

Combination with KX6 series<br />

A<br />

B<br />

case<br />

In case OA processing units only<br />

are connected with KX6 outdoor units<br />

In case both of OA processing units<br />

and dedicated air-conditioner<br />

are connected with KX6 outdoor unit.<br />

Combination<br />

The total capacity of FDU-F is 50~100% of outdoor capacity<br />

and max quantity of FDU-F is 2 units.<br />

The total capacity of FDU-F and dedicated air-conditioners is 50~100% of outdoor<br />

capacity and max quantity of FDU-F should be below 30% of outdoor unit capacity.<br />

[A]<br />

10HP<br />

FDU850FKXE6F<br />

(5HP)<br />

FDU850FKXE6F<br />

(5HP)<br />

[B]<br />

Less than 30%<br />

FDU850FKXE6F<br />

18HP (5HP)<br />

6HP 6HP<br />

Concept (Difference between FDU-F and SAF)<br />

SAF is the energy recovery ventilation unit which can recover heat energy from exhaust air to supply air and "has no air processing<br />

function, but FDU-F is air processing unit which can treat the supply air closer to room temperature by cooling or heating in connection<br />

with KX6 refrigerant <strong>system</strong> and exhaust air is discharged to outside of the room.<br />

FDU-F OA Processing units<br />

Outside<br />

<strong>Air</strong> Supply<br />

Exhaust <strong>Air</strong><br />

Direct Expansion<br />

Heat Exchanger<br />

SAF<br />

Outside<br />

<strong>Air</strong> Supply<br />

Exhaust <strong>Air</strong><br />

79


R410A<br />

Specifications<br />

Item<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Power source<br />

kW<br />

kW<br />

Power Cooling<br />

consumption<br />

kW<br />

Heating<br />

Sound pressure level dB(A)<br />

Exterior dimension<br />

HxWxD<br />

mm<br />

Net weight<br />

kg<br />

CMM<br />

<strong>Air</strong> flow (Standard)<br />

CMH<br />

External static pressure Pa<br />

<strong>Air</strong> filter, Q'ty<br />

Remote control(option)<br />

Installation data<br />

Refrigerating piping size<br />

Model<br />

mm<br />

(in)<br />

FDU500FKXE6F<br />

9.0<br />

4.2<br />

0.11<br />

0.11<br />

38<br />

360x820x830<br />

48<br />

8.5<br />

510<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

FDU850FKXE6F<br />

14.0<br />

7.0<br />

0.16<br />

0.16<br />

41<br />

360x1200x830<br />

62<br />

14<br />

840<br />

1 Phase 220-240V, 50Hz<br />

FDU1300FKXE6F<br />

22.4<br />

10.9<br />

0.27<br />

0.27<br />

43<br />

82<br />

22<br />

1320<br />

200<br />

Procure locally<br />

wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø19.05(3/4")<br />

360x1570x830<br />

FDU1800FKXE6F<br />

28.0<br />

14.8<br />

0.31<br />

0.31<br />

46<br />

84<br />

30<br />

1800<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø22.22(7/8")<br />

1. The data are measured at 33ºCDB 28ºCWB (68%RH) during cooling and 0ºCDB-2.9ºCWB (50%RH) during heating (no frost). External static pressure of indoor unit with optional fan controlling kit "U-FCRB" is 100Pa.<br />

2. Temperature range of outdoor air must be 20~40ºCDB (32ºCWB) during cooling and -10~24ºCDB during heating.<br />

3. Operation sound is measured in an anechoic room based on JIS standard. In case of actual room installation, it usually becomes higher than the displayed value due to the surrounding noise and echo.<br />

4. The total connection capacity of the other standard air conditioning units and the outdoor air processing units must be from 50% to 100% (the total includes the outdoor air processing unit). The connection capacity<br />

of the outdoor air processing unit must not exceed 30% of the capacity of the outdoor unit.<br />

5. Single outdoor air processing unit can be used alone. The connection capacity of the outdoor air processing unit must be from 50% to 100% of the total capacity of the outdoor unit.<br />

6. Single outdoor air processing unit can be used alone. Maximum number of outdoor air processing units that can be connected to the outdoor unit is 2units.<br />

7. Values of sound pressure level become increased 5dB(A), when external static pressure is 200Pa (factory setting).<br />

8. Values of air flow volume are those at external static pressure 200Pa (factory setting).<br />

Dimensions<br />

All measurements in mm.<br />

FDU500FKXE6F<br />

Suspension bolts pitch<br />

Suspension bolts pitch<br />

(Inner size of duct flange)<br />

12-M5 screw<br />

Duct connection port<br />

for outdoor air inlet<br />

Above<br />

Control box<br />

12-M5 screw Port for air outlet<br />

(Inner size of duct flange)<br />

or more<br />

Service space<br />

or more<br />

(Inner size of duct flange)<br />

Plan view<br />

Installation space<br />

or more<br />

Piping space<br />

Installation space<br />

or more<br />

(Below suspension<br />

bolt pitch)<br />

Installation space<br />

Below<br />

Front view<br />

(Service from side) (Service from below) (Service from side and below)<br />

Slab<br />

Ceiling<br />

or more<br />

or more<br />

(Inner size of duct flange)<br />

Symbol<br />

Content<br />

Gas piping<br />

Liquid piping<br />

Drain piping connection<br />

Power supply wiring connection<br />

Suspension bolt<br />

Inspection Opening<br />

Inspection Opening<br />

80


FDU850FKXE6F<br />

Suspension bolts pitch<br />

(Inner size of duct flange)<br />

FDU1300FKXE6F, FDU1800FKXE6F<br />

Suspension bolts pitch<br />

Suspension bolts pitch<br />

Suspension bolts pitch<br />

16-M5 screw<br />

Duct connection port<br />

for outdoor air inlet<br />

Above<br />

Control box<br />

12-M5 screw Port for air outlet<br />

(Inner size of duct flange)<br />

(Inner size of duct flange)<br />

(Below suspension<br />

bolt pitch)<br />

or more or more<br />

Plan view<br />

Installation space<br />

or more Installation space Front view<br />

Installation space<br />

Slab<br />

Ceiling<br />

Service space<br />

or more<br />

(Service from side)<br />

Piping space<br />

(Service from below) (Service from side and below)<br />

Below<br />

or more<br />

or more<br />

(Inner size of duct flange)<br />

Symbol<br />

Content<br />

Gas piping<br />

Liquid piping<br />

Drain piping connection<br />

Power supply wiring connection<br />

Suspension bolt<br />

Inspection Opening<br />

Inspection Opening<br />

(Inner size of duct flange)<br />

20-M5 screw<br />

Duct connection port<br />

for outdoor air inlet<br />

Above<br />

Control box<br />

20-M5 screw Port for air outlet<br />

(Inner size of duct flange)<br />

or more<br />

(Inner size of duct flange)<br />

Installation space<br />

or more<br />

or more Installation space<br />

Plan view<br />

(Below suspension<br />

bolt pitch)<br />

Below<br />

Front view<br />

or more<br />

(Inner size of duct flange)<br />

Slab<br />

Ceiling<br />

Service space Service space<br />

or more<br />

Piping space<br />

(Service from side) (Service from below) (Service from side and below)<br />

or more<br />

Symbol<br />

Content<br />

Gas piping<br />

Liquid piping<br />

Drain piping connection<br />

Power supply wiring connection<br />

Suspension bolt<br />

Inspection Opening<br />

Inspection Opening<br />

81


Capacity<br />

R410A<br />

Fresh <strong>Air</strong> Ventilation and Heat Exchange unit<br />

SAF-E4<br />

Model No.<br />

SAF250E4<br />

SAF350E4<br />

SAF500E4<br />

SAF800E4<br />

SAF1000E4<br />

Re; Building Regulations Part L2<br />

The Part L2 (April 2006) regulations limit the amount of electrical/gas<br />

power to be used to provide heating or cooling in commercial<br />

buildings. Therefore the building designer needs to select energy<br />

efficient heating/cooling equipment, and to minimise energy losses<br />

through ventilation <strong>system</strong>s.<br />

The SAF recovers heat energy which would otherwise be exhausted<br />

to atmosphere, and uses this energy to warm the air entering the<br />

building. The reverse happens in warmer climates, where the<br />

exhausted cool air is used to partially cool the incoming air.<br />

Capturing this waste energy, means the heating/<br />

cooling requirements of the building are reduced, so<br />

smaller size plant can be selected, savings can be<br />

made in long term energy consumption, and carbon<br />

emissions are reduced.<br />

The inclusion of the SAF energy recovery ventilation<br />

units in the building design, will reduce the total<br />

amount of carbon emissions.<br />

Structure (SAF1000E4)<br />

Plate heat exchanger<br />

Damper<br />

Principle of operation (simple ventilation)<br />

FREE COOLING<br />

Principle of operation (heat exchanging)<br />

ENERGY RECOVERY<br />

Exhaust <strong>Air</strong><br />

outdoor<br />

indoor<br />

Supply <strong>Air</strong><br />

Exhaust <strong>Air</strong><br />

outdoor<br />

indoor<br />

Supply <strong>Air</strong><br />

EA<br />

(Exhaust <strong>Air</strong>)<br />

RA<br />

(Room <strong>Air</strong>)<br />

27deg<br />

10deg<br />

33deg<br />

29deg<br />

Outside <strong>Air</strong><br />

Room <strong>Air</strong><br />

Outside <strong>Air</strong><br />

Room <strong>Air</strong><br />

OA<br />

(Outside <strong>Air</strong>)<br />

Specifications<br />

SA<br />

(Supply <strong>Air</strong>)<br />

10deg<br />

27deg<br />

e.g. For cooling<br />

in winter time<br />

35deg<br />

27deg<br />

Item Model SAF250E4 SAF350E4 SAF500E4 SAF800E4 SAF1000E4<br />

Power source<br />

1 Phase 220-240V, 50Hz<br />

Exterior dimensions<br />

Height x Width x Depth mm 270x882x599 270x882x804 270x962x904 388x1322x884 388x1322x1135<br />

Exterior appearance<br />

Galvanised steel sheet<br />

Power input<br />

W 99-114 124-137 169-188 309-359 360-399<br />

Running current A 0.46-0.48 0.59-0.60 0.79-0.81 1.48-1.50 1.85-1.93<br />

Enthalpy Cooling 63 66 62 65<br />

exchange<br />

UHi efficiency Heating 70 69 67 71<br />

Temperature exchange efficiency 75<br />

Enthalpy Cooling 63 66 62 65<br />

exchange<br />

Hi efficiency Heating %<br />

70 69 67 71<br />

Temperature exchange efficiency 75<br />

Enthalpy Cooling 66 69 77 68 68<br />

exchange<br />

Lo efficiency Heating 73 71 67 74 73<br />

Temperature exchange efficiency 77 77 75 76 76<br />

Motor & Q’ty kW 0.02x2 0.044x2 0.062x2 0.117x2 0.137x2<br />

<strong>Air</strong> handling equipment Fan type & Q’ty Sirocco fan x 2<br />

UHi 250 350 500 800 1000<br />

<strong>Air</strong> flow Hi m 3 /h 250 350 500 800 1000<br />

Lo 170 280 370 650 810<br />

UHi 90 95 105 140 90<br />

Available static pressure Hi Pa 80 65 70 110 55<br />

Lo 37 42 38 70 35<br />

Remote control<br />

Out take intake air<br />

<strong>Air</strong> filter<br />

Exhaust air<br />

Standard equipment<br />

Protection for element (Washable) PS400<br />

82


Dimensions<br />

All measurements in mm.<br />

SAF250E4,350E4,500E4<br />

SAF800E4<br />

SAF1000E4<br />

Installation reference<br />

Pipe Hood<br />

Outside Intake Duct<br />

Ceiling Suspension Bolt<br />

Supply <strong>Air</strong> Duct<br />

SA<br />

(Supply <strong>Air</strong>)<br />

OA<br />

(Outside <strong>Air</strong>)<br />

EA<br />

Exhaust<br />

<strong>Air</strong><br />

Room Intake Duct<br />

Heat Insulation<br />

Material<br />

Exhaust <strong>Air</strong> Duct<br />

RA<br />

(Room <strong>Air</strong>)<br />

Room Intake Opening<br />

(Supply/Exhaust <strong>Air</strong> Grill)<br />

Inside Supply Opening<br />

(Supply/Exhaust <strong>Air</strong> Grill)<br />

Dimension table<br />

Unit:mm<br />

NO. Name Quantity Material Remarks<br />

1 Frame 1 Zinc-plated steel<br />

2 Adaptor 4 ABS Resin<br />

3 Electrical Equipment Box 1<br />

Model a b c d e<br />

SAF250E4 142 810 599 315 655<br />

SAF350E4 162 810 804 480 860<br />

SAF500E4 202 890 904 500 960<br />

4 Inspection Cover 1 Zinc-plated steel<br />

5 Fan 2 ABS Resin<br />

6 Motor 2<br />

7 Heat Exchange Element 2 Flame Retardant Paper + Plastic <strong>Air</strong> to air Heat Exchanger<br />

Model f g h i j<br />

SAF250E4 ø219 ø164 ø144 882 95<br />

SAF350E4 ø219 ø164 ø144 882 95<br />

8 Filter 2 Non-woven Cloth<br />

9 Damper 1<br />

10 Damper Motor 1<br />

11 Ceiling Suspension Fixture 4 Zinc-plated Steel<br />

Collection Efficiency<br />

Gravimetric Method 82%<br />

SAF500E4 ø246 ø210 ø194 962 107<br />

Note(1) An inspection port is needed for cleaning the heat exchanger and filter 1 or 2 times a year.<br />

83


R410A<br />

Fresh <strong>Air</strong> DX Assembly<br />

Drain up kit<br />

(option, built-in type)<br />

(600mm)<br />

DXA-DU-E<br />

Remote control<br />

(option)<br />

Wired<br />

RC-E5<br />

RCH-E3<br />

Model No.<br />

SAF-DX250E6<br />

SAF-DX350E6<br />

SAF-DX500E6<br />

SAF-DX800E6<br />

SAF-DX1000E6<br />

Wireless<br />

RCN-KIT3-E<br />

•SAF-DX is a heating or cooling coil incorporating MHI KX6 series controls. It can be used in combination with our SAF series of total heat exchanger.<br />

•Combination of SAF-DX together with other KX6/KXR6 indoor units is possible. The capacity code index of each model is shown below and must be used<br />

when making the <strong>system</strong> selection. Total capacity code index must be within 100% of outdoor unit capacity code index.<br />

•Remote control option is the same as with other KX6/KXR6 indoor units (see above). Connection to all superlink controls is also possible.<br />

•Optional condensate lift mechanism is also available (600mm height).<br />

•Return air temp. control or supply air temp. control can be selectable.<br />

OA<br />

(Outside <strong>Air</strong>)<br />

EA<br />

(Exhaust <strong>Air</strong>)<br />

Total heat<br />

exchanger<br />

Return / fresh air<br />

temp.sensor<br />

RA<br />

(Room <strong>Air</strong>)<br />

SAF-DX<br />

Supply / fresh air temp.<br />

sensor<br />

SA<br />

Heating or cooling coil<br />

(Supply <strong>Air</strong>)<br />

SAF-DX can provide heating or cooling to the fresh air supplied through a 3rd party air handling unit or total heat exchanger such as our SAF series.<br />

Specifications<br />

Item<br />

Model SAF-DX250E6 SAF-DX350E6<br />

Nominal cooling capacity *1<br />

Nominal heating capacity *2<br />

Capacity code<br />

kW<br />

kW<br />

2.0<br />

1.8<br />

22<br />

2.8<br />

2.2<br />

28<br />

Power source<br />

Power<br />

consumption<br />

Running<br />

current<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

W<br />

Exterior dimensions<br />

H x W x D<br />

mm<br />

Net weight<br />

kg<br />

<strong>Air</strong> flow (Standard) CMH<br />

Internal resistance Pa<br />

Remote control(option)<br />

Installation data<br />

Refrigerant piping size<br />

mm(in)<br />

A<br />

250<br />

38<br />

SAF-DX500E6 SAF-DX800E6 SAF-DX1000E6<br />

3.6<br />

2.8<br />

36<br />

5.6<br />

4.5<br />

56<br />

6.3<br />

5.6<br />

71<br />

1 Phase 220-240V, 50Hz<br />

7.2<br />

7.2<br />

0.05<br />

0.05<br />

12.3 13.6 16.1<br />

18.4<br />

350<br />

500 800<br />

1000<br />

66<br />

wired: RC-E5, RCH-E3 wireless: RCN-KIT3-E<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø9.52(3/8")<br />

(1) The data are measured at the following conditions.<br />

Item Return/fresh air temperature Outdoor air temperature Standards<br />

Operation DB<br />

WB<br />

DB<br />

WB<br />

Cooling*1 27ºC 19ºC 35ºC 24ºC<br />

ISO-T1<br />

Heating*2<br />

20ºC<br />

7ºC<br />

6ºC<br />

(2) This air-conditioner is manufactured and tested in conformity with ISO-T1 "UNITARY AIR-CONDITIONERS".<br />

315 x 452 x 422 315 x 537 x 422<br />

315 x 682 x 422<br />

315 x 822 x 422<br />

Liquid line:ø6.35(1/4")<br />

Gas line:ø12.7(1/2")<br />

Liquid line:ø9.52(3/8")<br />

Gas line:ø15.88(5/8")<br />

84


Dimensions<br />

All measurements in mm.<br />

SAF-DX250E6,350E6<br />

SAF-DX500E6<br />

SAF-DX800E6<br />

SAF-DX1000E6<br />

85


R410A<br />

Control Systems<br />

<br />

Remote Control line up (except SAF)<br />

indoor unit remote control indoor unit remote control indoor unit remote control indoor unit remote control<br />

RC-EX1A<br />

FDT RCN-T-36W-E FDTS RCN-TS-E FDE RCN-E-E<br />

wired all models RC-E5 wireless FDTC RCN-TC-24W-ER FDK22~56 RCN-K-E FDFW RCN-FW-E<br />

RCH-E3<br />

FDTW RCN-TW-E FDK71 RCN-K71-E others* RCN-KIT3-E<br />

The wireless remote control is not applicable to the Individual flap control <strong>system</strong> and the Flap control <strong>system</strong>.<br />

* When the wireless remote control is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo). *FDTQ, FDU, FDUM, FDUT, FDUH, FDU-F<br />

Wired remote control with weekly timer (option)<br />

RC-E5<br />

Run hour meters to facilitate maintenance checking<br />

The RC-E5 controller enables<br />

RC-E5 stores operation data when an anomaly occurs and indicates<br />

extensive access to service and<br />

the error on the LCD. It also displays cumulative operation hours of<br />

maintenance technical data<br />

the air conditioner and compressor since commissioning.<br />

combined with easy to use<br />

functions and a clear LCD display.<br />

Room temperature controlled by the remote control sensor<br />

The temperature sensor is housed in the top<br />

section of the remote control unit. This arrangement<br />

has improved the sensitivity of the remote control<br />

unit’s sensor, which permits more finely<br />

controlled air conditioning.<br />

Weekly timer function as standard<br />

RC-E5 provides (as a standard feature) a weekly timer, which<br />

allows one-week operation schedules to be registered. A user can<br />

specify up to four times a day to start/stop the air conditioner.<br />

(Temperature setting is also possible with the timer).<br />

Changeable set temperature ranges<br />

RC-E5 allows the upper and lower limits of a set temperature range<br />

to be specified separately.<br />

By adjusting a set temperature range, you can ensure energy saving<br />

air conditioning by avoiding excessive cooling or heating.<br />

Timer operation<br />

Changeable range<br />

Upper limit<br />

20~30ºC(effective for heating operation)<br />

Lower limit 18~26ºC(effective for non-heating operation)<br />

Simple remote control (option)<br />

RCH-E3 (wired)<br />

Considering specialized usage in hotel rooms, control buttons are limited only to<br />

minimum required functions such as ON/OFF, mode, temperature setting and fan<br />

speed. It is really simple and easy to use.<br />

Thermistor (option)<br />

SC-THB-E3<br />

In case sensor in the indoor units or the<br />

remote control sensor can not sense the<br />

room temperature correctly, or individual<br />

Up to 16 units<br />

AUTO restart<br />

remote control in each room is not required<br />

but only sensor is required (as when center<br />

It can control up to 16 units This function allows starting the air conditioner control <strong>system</strong> is in<br />

individually, with pressing the automatically when power supply is restored after<br />

place), install SC-<br />

AIR CON No. button.<br />

power failure or by turning on the power switch.<br />

THB-E3 at proper<br />

RCH-E3 is not applicable to the Individual flap control <strong>system</strong> and the Flap control <strong>system</strong>.<br />

place in the rooms.<br />

When RCH-E3 is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo).<br />

*<br />

8m<br />

Wireless remote control (option)<br />

For wireless control simply insert the infra-red receiver kit on a corner of the panel<br />

RCN-T-36W-E,<br />

RCN-TC-24W-ER<br />

RCN-TW-E RCN-TS-E RCN-K-E,<br />

RCN-K71-E<br />

RCN-E-E RCN-FW-E RCN-KIT3-E<br />

86


SUPERLINK-<br />

MHI has now combined simplicity of installation with our highly sophisticated<br />

Superlink- control <strong>system</strong>, to offer building owners and occupiers a<br />

comprehensive control and management <strong>system</strong>, while providing complete<br />

commissioning and service maintenance assistance for installers and service<br />

engineers. The Superlink- network utilises two wire, non-polar cable - for<br />

further details of wiring.<br />

Superlink- is an advanced high speed data transmission <strong>system</strong> that can<br />

connect up to 128 indoor units and 32 outdoor units as a network. MHI offers<br />

a wide range of control options for the Superlink- network to suit any<br />

application large or small, as well as connection to new or existing building<br />

management <strong>system</strong>s. Individual MHI split <strong>system</strong>s can also be integrated on<br />

to the Superlink- network using SC-ADNA-E.<br />

Multi-KX6 outdoor units<br />

"Micro KX"<br />

Multi-KX6 indoor units<br />

Center Control SC-SL2NA-E<br />

Capable of control and monitoring up to 64<br />

indoor units. All operational functions, plus<br />

enable/disable connected remote control.<br />

Individual On/Off Control<br />

KX6 Outdoor units<br />

Multi-KX6 indoor units<br />

SC-WGWNA-A/B<br />

PC Control Interface<br />

KX6 twined Outdoor units<br />

Center Control<br />

SC-SL3NA-AE/BE<br />

Multi-KX6 indoor units<br />

with individual room control<br />

Center Control SC-SL1N-E<br />

3-core + earth cable<br />

for connecting indoor<br />

and outdoor units<br />

3-core cable for<br />

connecting indoor<br />

and outdoor units<br />

3-core cable for<br />

connecting indoor<br />

and outdoor units<br />

3-core + earth cable<br />

for connecting indoor<br />

and outdoor units<br />

Wireless<br />

remote<br />

control<br />

SRK/SRF-ZJXseries<br />

SC-BIKN-E<br />

SC-ADNA-E<br />

SC-ADNA-E<br />

SC-ADNA-E<br />

SC-ADNA-E<br />

One-to-one<br />

Wireless<br />

87


R410A<br />

<br />

SC-SL1N-E<br />

Start/stop control of up to 16 indoor units either<br />

individually or collectively.<br />

Simple centralised control.<br />

1. The SC-SL1N-E is connected to the Superlinknetwork<br />

via 2-core, non-polar wires (‘AB’ connection).<br />

2. It will monitor and control the start/stop function of up<br />

to 16 units, with the sixteen operation button.<br />

3. The unit or group numbers in operation or in need of<br />

service are displayed with an LED.<br />

4. Collective start/stop is also available through the<br />

simultaneous on/off button.<br />

5. Up to 12 SC-SL1N-E units can be connected to a Superlink- network (consisting of up<br />

to 128 indoor units).<br />

6. If a power failure occurs, the SC-SL1N-E will resume the operation of the <strong>system</strong><br />

according to a stored operation condition, once power is restored.<br />

SC-SL2NA-E<br />

Central control of up to 64 indoor units including weekly timer function as standard.<br />

1. The SC-SL2NA-E is connected to the<br />

Superlink- network via 2-core, non-polar<br />

wires (‘AB’ connection).<br />

2. It will monitor and control the start/stop<br />

function of up to16 units, or 16 groups of<br />

units, with the sixteen operation buttons.<br />

3. It also monitors and controls the following<br />

functions for individual units, groups of<br />

units or the complete network: operation<br />

mode, set point temperature, return air<br />

temperature, louvre position, error code. <strong>Air</strong> flow and center lock function.<br />

4. The unit or group numbers in operation or in need of service are displayed with an LCD.<br />

5. Collective start/stop is also available through the simultaneous on/off button.<br />

6. If a power failure occurs, the SC-SL2NA-E will resume the operation of the <strong>system</strong><br />

according to a stored operation condition, once power is restored.<br />

7. The SC-SL2NA-E can be connected to an external timer to facilitate timed on/off cycles.<br />

8. The number of units connected to one network are detailed on the table below.<br />

Example of control by a centre control SC-SL1N-E<br />

SL1N-E<br />

More than one unit (up to 16) can be controlled for individual or collective<br />

start/stop operation and indication of unit statuses such as in operation or in<br />

need of service.<br />

• Outer dimensions: H120 x W120 x D15+62*mm.<br />

62* is the measurement including the part contained in a recess.<br />

Example of control by a centre control SC-SL2NA-E<br />

SL1N-E<br />

An SC-SL2NA-E performs the start/stop control, monitoring and mode<br />

setting of up to 64 units. It is a high quality air conditioner control <strong>system</strong><br />

that allows up to 64 indoor units to be freely grouped into 1 to 16 groups.<br />

It allows not only the start/stop control but also the monitoring, display of<br />

operation statuses such as in operation or in need of service and mode<br />

setting such as switching of operation modes of connected units collectively,<br />

by group or individually.<br />

• Outer dimensions: H120 x W215 x D25+35*mm.<br />

35* is the measurement including the part contained in a recess.<br />

Combination of Center Control and BMS interface unit<br />

SC-SL1N-E<br />

SC-SL2NA-E<br />

SC-SL3NA-AE/BE<br />

SC-WGWNA-A/B<br />

SC-BGWNA-A/B<br />

SC-LGWNA-A<br />

SC-SL1N-E<br />

Yes( 1)<br />

Yes( 1)<br />

Yes( 1)<br />

Yes( 2)<br />

Yes( 2)<br />

Yes( 2)<br />

SC-SL2NA-E<br />

Yes( 1)<br />

Yes( 1)<br />

Yes( 1)<br />

Yes( 2)<br />

Yes( 2)<br />

Yes( 2)<br />

Yes:connectable No:not connectable<br />

SC-SL3NA-AE/BE<br />

Yes( 1)<br />

Yes( 1)<br />

Yes( 1)<br />

Yes( 2)<br />

Yes( 2)<br />

Yes( 2)<br />

SC-WGWNA-A/B<br />

Yes( 2)<br />

Yes( 2)<br />

Yes( 2)<br />

No<br />

No<br />

No<br />

SC-BGWNA-A/B<br />

Yes( 2)<br />

Yes( 2)<br />

Yes( 2)<br />

No<br />

No<br />

No<br />

SC-LGWNA-A<br />

Yes( 2)<br />

Yes( 2)<br />

Yes( 2)<br />

No<br />

No<br />

No<br />

( 1) Number of units in combination of SC-SL1N-E, SC-SL2NA-E and SC-SL3NA-AE/BE<br />

SC-SL3NA-AE/BE<br />

SC-SL2NA-E<br />

SC-SL1N-E<br />

Connectable number of controls in one superlink-<br />

0<br />

1<br />

0<br />

12<br />

1-2<br />

8<br />

3-4<br />

4<br />

5-8<br />

0<br />

0-2<br />

8<br />

3-4<br />

4<br />

5-8<br />

0<br />

0-2<br />

8<br />

network<br />

2<br />

3-4<br />

4<br />

Regarding previous Superlink, refer to Technical Manual '06 SC-T-111, '08 SC-T-119.<br />

5-8<br />

0<br />

( 2) Number of units in combination of SC-WGWNA-A/B, SC-BGWNA-A/B, SC-LGWNA-A, SC-SL3NA-AE/BE, SC-SL2NA-E and SC-SL1N-E<br />

Connectable number of controls in one superlink- network<br />

SC-WGWNA-A/B or SC-BGWNA-A/B or SC-LGWNA-A<br />

1<br />

SC-SL1N-E<br />

0-4<br />

SC-SL2NA-E<br />

0-1<br />

SC-SL3NA-E-AE/BE<br />

0-1<br />

Regarding previous Superlink, refer to Technical Manual '06 SC-T-111, '08 SC-T-119.<br />

88


SC-SL3NA-AE/BE<br />

MHI introduces the full colour touch<br />

screen central control SC-SL3NA-<br />

AE/BE, with 7 inch interactive LCD<br />

display. Offers control, monitoring,<br />

scheduling and service/maintenance<br />

functions for up to 128 indoor units.<br />

Indoor unit 128 units<br />

Indoor units can be controlled,<br />

scheduled, monitored and<br />

interrogated either individually, as<br />

groups or as blocks of groups with<br />

the following functions:<br />

Control Monitoring Scheduling Administration/Service<br />

Run/Stop Operating state Yearly schedule Block definition<br />

Mode (cool/heat/fan) Mode Today's schedule Group definition<br />

Set temperature Set temperature Special day schedule Unit definition<br />

Operation permitted/prohibited Room temperature Time and date setting<br />

Fan speeds Operation enabled Alarm history<br />

<strong>Air</strong> direction Fan speed Energy consumption calculation period<br />

Filter reset <strong>Air</strong> direction Energy consumption cumulative operation time<br />

Filter sign<br />

Maintenance (1, 2 or back-up)<br />

Demand control<br />

Breakdown<br />

Emergency stop<br />

Power failure recovery control<br />

SC-GIFN-E<br />

Interface kit<br />

Collective stop signal input<br />

NEW<br />

• Applicable products<br />

Ventilation fan, <strong>Air</strong> purifier<br />

• By using SC-GIFN-E together with central control such as SC-SL1N-E,<br />

SC-SL2NA-E and SC-SL3NA-AE/BE, you can start-stop, operate & monitor<br />

the operation of applicable products.<br />

SLA3R-BX<br />

Control Box (option)<br />

In case SC-SL3NA-AE/BE is fixed in the wall, use SLA3R-BX as optional parts.<br />

Inner wall<br />

Central Control<br />

40<br />

more than<br />

105mm<br />

Electric power calculation function:<br />

Electric wires<br />

Beam of building<br />

Fix the SLA3R-BX to the<br />

beam in the building<br />

SLA3R-BX<br />

(for SC-SL3NA-BE only) Item Model SC-SL3NA-AE/SC-SL3NA-BE<br />

SC-SL3NA-BE gives outputs as “electric power consumption kW data -each<br />

indoor unit, each group, each SUPERLINK- <strong>system</strong> and each power pulse<br />

<strong>system</strong>-” and uses USB memory.<br />

The data can be edited by using the software that comes with the unit.<br />

Method of data saving<br />

Calculation software<br />

<strong>Air</strong>-conditioner power proportional distribution<br />

pulse input<br />

Connecting indoor units number (Maximum)<br />

SC-SL3NA-BE<br />

USB<br />

Standard<br />

8 <strong>system</strong>s<br />

128<br />

Ambient temperature during use<br />

Power supply<br />

Power consumption<br />

External dimensions<br />

(Height x Width x Depth)<br />

Net weight<br />

Number of<br />

connectable units (indoor units)<br />

LCD touch panel<br />

Outputs Inputs<br />

SL (Superlink) signal inputs<br />

Gas, Power pulse input*<br />

Emergency stop signal input*<br />

Demand signal input*<br />

Simultaneous operation output<br />

Simultaneous error output<br />

Printed board<br />

Terminal block<br />

0 ~ 40 o C<br />

1 Phase 100-240V 50/60Hz<br />

18W<br />

162mm x 240mm x 108mm<br />

2.0kg<br />

up to 128 units<br />

Colour LCD, 7 inches wide<br />

3 <strong>system</strong>s<br />

8-point pulse width 100ms or more<br />

1 point non-voltage a contact input<br />

continuous input (closed, forced stop)<br />

1 point non-voltage a contact input<br />

continuous input (closed, demand control)<br />

1 point maximum rated current 40mA, 24 V<br />

During full stop; Open. If even one unit is operating; Closed<br />

1 point maximum rated current 40mA, 24 V<br />

Normal; closed. If even one unit is abnormal; Open<br />

*The receiving side power supply is DC 12V (10mA).<br />

The air conditioning charges calculations of this unit are based on OIML, the international standard.<br />

* In case embodying in a wall, please be sure to special box SLA3R-BX (option).<br />

SW1<br />

SW2<br />

SW3<br />

ten's place<br />

one's place<br />

hundred's<br />

place<br />

51X 52 52R<br />

Address setting switch<br />

Set address number will<br />

be the address for<br />

SC-SL1N-E,<br />

SC-SL2NA-E,<br />

SC-SL3NA-AE/BE<br />

1 2 3 4 5 6 7 8 A B<br />

Net work communication line<br />

AC220-240V<br />

To A & B terminal block on<br />

SC-SL1N-E,<br />

Anomalous signal input<br />

SC-SL2NA-E,<br />

SC-SL3NA-AE/BE<br />

Operation signal input<br />

Net work<br />

Start-Stop command output<br />

89


R410A<br />

<br />

SC-WGWNB-A/SC-WGWNB-B (Web gateway)<br />

(SC-WGWNB-B is with electric power calculation function)<br />

Internet<br />

Explorer<br />

HUB<br />

Ethernet 10 BASE-T/<br />

100BASE-TX<br />

pulse<br />

Watt meter pulse input P1<br />

P2<br />

P3<br />

P4<br />

(in case of SC-WGWNB-B)<br />

48 cells<br />

48 cells<br />

SC-ADNA-E<br />

<br />

SC-BGWNA-A/A1, SC-BGWNA-B (BACnet gateway)<br />

48 cells<br />

SUPERLINK-<br />

SUPERLINK-<br />

64 units<br />

64 units<br />

No. 1 <strong>system</strong><br />

No. 2 <strong>system</strong><br />

SUPERLINK-<br />

64 units<br />

Cell<br />

No. 1 <strong>system</strong><br />

Production by order<br />

Control and monitoring of up to 96 cells (some cells can have two or more indoor units and total number of<br />

indoor units can be up to 128 units) centralised to a network PC using the Superlink- web gateway. Simple<br />

installation is assured with no special software requirements, operation is via Internet Explorer. A low power<br />

embedded CPU and compact flash ROM ensure a large storage capacity with high reliability (no moving parts<br />

such as a PC fan, etc). An IP address filter function combined with three-level user authentication check also<br />

ensures security.<br />

Additional engineering service cost etc. is required.<br />

Please consult your dealer when using this central control.<br />

PC requirements: Windows XP or Windows Vista or Windows 7.<br />

Monitor resolution 1024 x 768.<br />

Web browser requirements: Internet Explorer 6.0 or 7.0.<br />

(SC-BGWNA-A1 is with BLT Certification, SC-BGWNA-B is with electric power calculation function)<br />

SC-BGWNA-A/B is an interface device that converts MHI’s Superlink- communication data to BACnet code.<br />

Control and monitoring functions of the a/c <strong>system</strong> for up to 96 cells (some cells can have two or more indoor<br />

units and total number of indoor units can be up to 128 units) can be integrated to a central control point via<br />

the building management <strong>system</strong> network.<br />

Production by order<br />

Ethernet 10 BASE-T/100BASE-TX<br />

BACnet I/P Protocol.<br />

Network<br />

for<br />

lighting<br />

Emergency<br />

sensor<br />

network<br />

pulse<br />

Watt meter pulse input P1<br />

P2<br />

P3<br />

P4<br />

(in case of SC-BGWNA-B)<br />

48 cells<br />

SC-ADNA-E<br />

SUPERLINK-<br />

64 units<br />

No. 2 <strong>system</strong><br />

Cell<br />

Additional engineering service cost etc. is required.<br />

In case of SC-BGWNA-B, communication test by<br />

qualified person regarding electric cost calculation<br />

function is required before commissioning.<br />

Please consult your dealer when using this gateway.<br />

SC-LGWNA-A (LonWorks gateway)<br />

SC-LGWNA-A is an interface device that converts MHI’s Superlink- communication data to LonWorks code.<br />

Control and monitoring functions of the a/c <strong>system</strong> for up to 96 indoor units can be integrated to a central<br />

control point via the building management <strong>system</strong> network.<br />

SUPERLINK- No. 1 <strong>system</strong><br />

48 units<br />

Production by order<br />

LonWorks network<br />

(FTT-10)<br />

Network<br />

for<br />

lighting<br />

Emergency<br />

sensor<br />

network<br />

SC-ADNA-E<br />

SUPERLINK- No. 2 <strong>system</strong><br />

48 units<br />

Additional engineering service cost etc. is required.<br />

Please consult your dealer when using this gateway.<br />

90


Service/maintenance and monitoring<br />

The design of the outdoor units separates the air flow compartment from<br />

the mechanical compartment, allowing easy access to serviceable parts<br />

by simply removing the panel.<br />

<strong>Air</strong> flow chamber<br />

This design also means that the base plate of the air flow compartment<br />

acts as a drain tray connected to a drain pipe that runs through the<br />

mechanical compartment, so a simple connection of a drain hose to the<br />

base of the unit is all that is required, no need for a separate drain tray to<br />

be installed.<br />

Mechanical<br />

chamber<br />

Service maintenance and trouble shooting tasks can be carried out easily<br />

via the wired remote controller, as well as a cooling test operation to<br />

assist commissioning.<br />

The outdoor unit control box is also equipped with a switch to invoke a<br />

'test-run' mode. This function can be used to help detect any installation<br />

errors, indoor/outdoor unit matching errors, EEV and valve operation. A<br />

'pump-down' switch on the PCB allows refrigerant to be recovered with<br />

the compressor protected.<br />

All outdoor unit PCBs are also equipped with a 7-segment digital display<br />

for detailed operation history and fault finding. Operation data is stored<br />

for the 30 minute period preceding a fault occurring and details are<br />

displayed on the 7-segment reading.<br />

Outdoor unit PCB 7-segment display<br />

Automatically produced test-run report<br />

Operation data storage during servicing<br />

6<br />

Operation data storage when a fault occurs<br />

Method of connecting Mente PC in the combination Multi <strong>system</strong><br />

Indoor<br />

unit<br />

Indoor<br />

unit<br />

Indoor<br />

unit<br />

Indoor<br />

unit<br />

Indoor<br />

unit<br />

Indoor<br />

unit<br />

91


INTESIS BMS Interface for MHI air conditioners<br />

All technical support, including specifying work, compatibility issues, product quality (repair and replacement issues), product liability issues<br />

and the required after sales service (including spare parts supply) will be provided by Intesis as it is an Intesis product.<br />

Product sales and delivery will be conducted by Intesis as well.<br />

For details concerning such matters please directly contact Intesis.<br />

Integration of MHI KX in your KNX installation by Superlink<br />

MH-AC-KNX-48<br />

(Max 48 indoor units / Superlink I & II)<br />

MH-AC-KNX-128<br />

(Max 128 indoor units / Superlink II)<br />

TOUCH SCREEN<br />

Alams<br />

Windows<br />

blinds<br />

Lighting Energy<br />

management<br />

HVAC<br />

INTEGRATED GATEWAY<br />

• Bidirectional: Supervision and Control<br />

• Robust and reliable hardware<br />

• Direct connection to KNX TP-1 BUS<br />

• Independent management of communications<br />

• Power supply: 230 VAC 50/60Hz<br />

• Wall mounting case<br />

Integration of MHI KX in your Modbus installation by Superlink<br />

MH-AC-MBS-48<br />

(Max 48 indoor units / Superlink I & II)<br />

MH-AC-MBS-128<br />

(Max 128 indoor units / Superlink II)<br />

MODBUS<br />

INTEGRATED GATEWAY<br />

• Bidirectional: Supervision and Control<br />

• Robust and reliable hardware<br />

• Modbus TCP or Modbus RTU RS-485/RS-232<br />

• Independent management of communications<br />

• Power supply: 230 VAC 50/60Hz<br />

• Wall mounting case<br />

92


Integration of MHI PAC in your KNX installation by Remote control line<br />

MH-RC-KNX-1i<br />

Example :<br />

Device as Master<br />

TOUCH SCREEN<br />

Example :<br />

Device as Slave<br />

TOUCH SCREEN<br />

Windows<br />

blinds<br />

Energy<br />

management<br />

Windows<br />

blinds<br />

Energy<br />

management<br />

RC-E5<br />

• Protocol : KNX TP-1 bus<br />

• Dimension : 71 x 71 x 27 mm<br />

• External Power supply : no need<br />

Alams<br />

Lighting<br />

HVAC<br />

Alams<br />

Lighting<br />

HVAC<br />

Integration of MHI PAC in your Modbus installation by Remote control line<br />

MH-RC-MBS-1<br />

Example :<br />

Device as Master<br />

MODBUS<br />

Example :<br />

Device as Slave<br />

MODBUS<br />

• Protocol : Modbus RTU (RS-485)<br />

• Dimension : 93 x 53 x 58 mm<br />

• External Power supply : no need<br />

RC-E5<br />

Integration of MHI PAC in your EnOcean installation by Remote control line<br />

MH-RC-ENO-1i/1iC<br />

Example :<br />

Device as Master<br />

Example :<br />

Device as Slave<br />

RC-E5<br />

• Protocol : EnOcean<br />

1i : 868MHz@EU<br />

1iC : 315MHz@USA, ASIA<br />

• Dimension : 100 x 70 x 28 mm<br />

• External Power supply : no need<br />

Please access the followings for details.<br />

URL<br />

email<br />

tel<br />

http://www.intesis.com<br />

info@intesis.com<br />

+34 938047 134<br />

93


R410A<br />

Outdoor units<br />

High Head series (90m)<br />

14~48hp (40.0~136.0kW)<br />

Model No.<br />

FDCH335KXE6-K<br />

FDCH400KXE6<br />

FDCH450KXE6<br />

FDCH504KXE6<br />

FDCH560KXE6<br />

FDCH560KXE6-K<br />

FDCH615KXE6<br />

FDCH680KXE6<br />

Nominal Cooling Capacity<br />

33.5 kW<br />

40.0 kW<br />

45.0 kW<br />

50.4 kW<br />

56.0 kW<br />

56.0 kW<br />

61.5 kW<br />

68.0 kW<br />

FDCH335KXE6-K & FDCH560KXE6-K are only used for combining with other models.<br />

•Maximum allowable height difference between the outdoor and<br />

the indoor unit located at the lowest height position has been<br />

increased from 50m to 90m.<br />

(When the outdoor unit is located at higher position than the<br />

indoor unit)<br />

Model No.<br />

FDCH735KXE6 (FDCH335-K+FDCH400)<br />

FDCH800KXE6 (FDCH400x2)<br />

FDCH850KXE6 (FDCH400+FDCH450)<br />

FDCH900KXE6 (FDCH450x2)<br />

FDCH960KXE6 (FDCH450+FDCH504)<br />

FDCH1010KXE6 (FDCH504x2)<br />

FDCH1065KXE6 (FDCH504+FDCH560)<br />

FDCH1130KXE6 (FDCH560x2)<br />

FDCH1180KXE6 (FDCH560-K+FDCH615)<br />

FDCH1235KXE6 (FDCH615x2)<br />

FDCH1300KXE6 (FDCH615+FDCH680)<br />

FDCH1360KXE6 (FDCH680x2)<br />

Production by order<br />

Nominal Cooling Capacity<br />

73.5 kW<br />

80.0 kW<br />

85.0 kW<br />

90.0 kW<br />

96.0 kW<br />

101.0 kW<br />

106.5 kW<br />

113.0 kW<br />

118.0 kW<br />

123.5 kW<br />

130.0 kW<br />

136.0 kW<br />

FDCH335KXE6-K<br />

FDCH400KXE6<br />

FDCH450KXE6<br />

FDCH504~680KXE6<br />

Total length:<br />

1000m<br />

To the<br />

first branch:<br />

max 130m<br />

Max: 10m<br />

Max: 5m<br />

Indoor unit<br />

Indoor unit<br />

Outdoor<br />

unit<br />

Max height difference:<br />

0.4m<br />

Height<br />

difference<br />

50~90m<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

15m<br />

Range of operation<br />

50<br />

+43ºC<br />

40<br />

30<br />

Cooling<br />

20<br />

+15.5ºC<br />

* 2<br />

from the first branch must be within 40m.<br />

* 3 In case of less than 50m, the High Head models can not be applied.<br />

In case Indoor unit is higher than outdoor unit, the High Head models<br />

can not be applied.<br />

* 1 * 3<br />

From the first<br />

10<br />

branch to the<br />

Heating<br />

furthest<br />

Indoor unit<br />

0<br />

indoor unit:<br />

-5ºC<br />

-5ºC<br />

90m* 2 -10<br />

Furthest<br />

indoor unit : 160m<br />

-20<br />

*<br />

1 Select the total pipe length depending on the connectable capacity of indoor units.<br />

Outdoor units' capacity A = Max. connectable capacity of indoor units (%)<br />

The difference between the longest and shortest indoor unit piping<br />

Connectable<br />

capacity<br />

A%<br />

130%<br />

400~450<br />

504~960<br />

1010~1360<br />

150%<br />

140%<br />

130%<br />

100%<br />

300 m<br />

510 m<br />

1000 m<br />

Total pipe length<br />

94


Specifications<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Cooling<br />

Power consumption<br />

Running current<br />

HxWxD<br />

Capacity connection<br />

Number of connectable indoor units<br />

Heating<br />

Cooling<br />

Heating<br />

R410A<br />

Cooling / Heating<br />

Liquid line<br />

Gas line<br />

Model<br />

kW<br />

kW<br />

A<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

FDCH400KXE6<br />

14HP<br />

40.0<br />

45.0<br />

11.27<br />

11.73<br />

18.4-16.9<br />

19.6-17.9<br />

1690x1350x720<br />

336<br />

FDCH450KXE6<br />

16HP<br />

45.0<br />

50.0<br />

12.97<br />

13.10<br />

21.1-19.3<br />

21.7-19.9<br />

59.5 / 59.5 62.5 / 62.5<br />

ø12.7(1/2")<br />

mm(in)<br />

ø25.4(1") [ø28.58(1 1/8")] ø28.58(1 1/8")<br />

%<br />

36<br />

40<br />

FDCH504KXE6 FDCH560KXE6<br />

18HP<br />

20HP<br />

3 Phase 380-415V, 50Hz<br />

50.4<br />

56.0<br />

56.5<br />

63.0<br />

8<br />

14.73<br />

15.12<br />

24.1-22.0<br />

25.2-23.1<br />

61.5 / 61.5<br />

36<br />

358<br />

11.5<br />

not fixed<br />

16.79<br />

16.79<br />

27.4-25.1<br />

28.0-25.7<br />

63.0 / 63.0 64.5 / 64.5<br />

ø15.88(5/8")<br />

ø28.58(1 1/8")<br />

40<br />

2048x1350x720<br />

FDCH615KXE6<br />

22HP<br />

61.5<br />

69.0<br />

20.37<br />

18.48<br />

33.1-30.3<br />

30.7-28.1<br />

44<br />

377<br />

FDCH680KXE6<br />

24HP<br />

68.0<br />

73.0<br />

24.98<br />

19.08<br />

40.3-36.9<br />

31.6-29.0<br />

65.0 / 65.0<br />

49<br />

Item<br />

Combination (FDCH)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Starting current<br />

Cooling<br />

Power consumption<br />

Heating<br />

Cooling<br />

Running current<br />

Heating<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Gas line<br />

Model<br />

kW<br />

kW<br />

A<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

kg<br />

kg<br />

mm(in)<br />

%<br />

FDCH735KXE6 FDCH800KXE6 FDCH850KXE6 FDCH900KXE6<br />

335KXE6-K<br />

400KXE6<br />

400KXE6<br />

450KXE6<br />

400KXE6<br />

400KXE6<br />

450KXE6<br />

450KXE6<br />

26HP<br />

28HP<br />

30HP<br />

32HP<br />

3 Phase 380-415V, 50Hz<br />

73.5<br />

82.5<br />

20.21<br />

20.66<br />

32.9-30.2<br />

34.4-31.4<br />

53<br />

80.0<br />

90.0<br />

22.54<br />

23.46<br />

36.8-33.8<br />

39.2-35.8<br />

16<br />

85.0<br />

95.0<br />

24.24<br />

24.83<br />

39.5-36.2<br />

41.3-37.8<br />

1690x2700x720<br />

336x2<br />

11.5x2<br />

ø19.05(3/4")<br />

ø31.8(1 1/4") [ø34.92(1 3/8")]<br />

not fixed<br />

58<br />

61<br />

90.0<br />

100.0<br />

25.94<br />

26.20<br />

42.2-38.6<br />

43.4-39.8<br />

65<br />

Item<br />

Combination (FDCH)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Starting current<br />

Cooling<br />

Power consumption<br />

Heating<br />

Cooling<br />

Running current<br />

Heating<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Gas line<br />

Model<br />

kW<br />

kW<br />

A<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

kg<br />

kg<br />

mm(in)<br />

%<br />

FDCH960KXE6 FDCH1010KXE6 FDCH1065KXE6 FDCH1130KXE6<br />

450KXE6<br />

504KXE6<br />

504KXE6<br />

560KXE6<br />

504KXE6<br />

504KXE6<br />

560KXE6<br />

560KXE6<br />

34HP<br />

36HP<br />

38HP<br />

40HP<br />

3 Phase 380-415V, 50Hz<br />

96.0<br />

108.0<br />

27.70<br />

28.22<br />

45.2-41.3<br />

46.9-43.0<br />

336+358<br />

69<br />

ø19.05(3/4")<br />

ø31.8(1 1/4")[ø34.92(1 3/8")]<br />

101.0<br />

113.0<br />

29.46<br />

30.24<br />

48.2-44.0<br />

50.4-46.2<br />

59<br />

16<br />

2048x2700x720<br />

11.5x2<br />

not fixed<br />

106.5<br />

119.5<br />

31.52<br />

31.91<br />

51.5-47.1<br />

53.2-48.8<br />

358x2<br />

62<br />

ø22.22(7/8")<br />

ø38.1(1 1/2")<br />

113.0<br />

127.0<br />

33.58<br />

33.58<br />

54.8-50.2<br />

56.0-51.4<br />

66<br />

Item<br />

Combination (FDCH)<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Refrigerant piping size<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Starting current<br />

Cooling<br />

Power consumption<br />

Heating<br />

Cooling<br />

Running current<br />

Heating<br />

HxWxD<br />

R410A<br />

Liquid line<br />

Gas line<br />

Model<br />

kW<br />

kW<br />

A<br />

kW<br />

kW<br />

A<br />

A<br />

mm<br />

kg<br />

kg<br />

mm(in)<br />

%<br />

FDCH1180KXE6<br />

560KXE6-K<br />

615KXE6<br />

42HP<br />

118.0<br />

132.0<br />

37.16<br />

35.27<br />

60.5-55.4<br />

58.7-53.8<br />

69<br />

FDCH1235KXE6<br />

615KXE6<br />

615KXE6<br />

44HP<br />

123.5<br />

138.0<br />

40.74<br />

36.96<br />

66.2-60.6<br />

61.4-56.2<br />

72<br />

3 Phase 380-415V, 50Hz<br />

16<br />

2048x2700x720<br />

377x2<br />

11.5x2<br />

ø22.22(7/8")<br />

ø38.1(1 1/2")<br />

not fixed<br />

FDCH1300KXE6<br />

615KXE6<br />

680KXE6<br />

46HP<br />

130.0<br />

142.0<br />

45.35<br />

37.56<br />

73.4-67.2<br />

62.3-57.1<br />

76<br />

FDCH1360KXE6<br />

680KXE6<br />

680KXE6<br />

48HP<br />

136.0<br />

146.0<br />

49.96<br />

38.16<br />

80.6-73.8<br />

63.2-58.0<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB. Piping length is 7.5m.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.<br />

80<br />

95


R410A<br />

Dimensions<br />

All measurements in mm.<br />

FDCH335KXE6-K, 400KXE6, 450KXE6<br />

Rear<br />

Dimensions of refrigerant<br />

pipe connection (plan)<br />

141<br />

234<br />

K<br />

B<br />

A<br />

95<br />

140.5<br />

75<br />

142.5<br />

19 726 19<br />

58.5 Anchor bolt positions for F, J<br />

647 58.5<br />

Anchor bolt positions for I<br />

250 850<br />

250<br />

175 1000 175<br />

J F I I F<br />

J I<br />

F<br />

I<br />

J<br />

F<br />

For dimensions of anchor bolt hole<br />

J<br />

<strong>Air</strong> intake<br />

74.5<br />

594 85<br />

232 101<br />

57<br />

85<br />

G<br />

232<br />

D(lower)<br />

185 H<br />

G<br />

148 352 158 342<br />

410 530 235<br />

80.5<br />

71<br />

C<br />

G<br />

140 120<br />

240<br />

296.7<br />

295 174<br />

22 720 22<br />

720<br />

126.2<br />

1350<br />

Drain pipe<br />

175<br />

80<br />

7-segment display<br />

inspection port<br />

Signal wire<br />

terminal block<br />

1690<br />

682 797.8<br />

Terminal block 6 Instruction plate<br />

6<br />

D (left) for power cable<br />

104.9<br />

95<br />

86.1<br />

connection<br />

D (front)<br />

84<br />

K<br />

B<br />

A<br />

C (front)<br />

166<br />

169<br />

211<br />

259<br />

291.6<br />

C (right)<br />

172<br />

90<br />

D (right)<br />

C (rear)<br />

172<br />

86.5<br />

220<br />

180<br />

550<br />

180<br />

214<br />

L<br />

44.7<br />

20<br />

Mark Item Installation example<br />

A Service valve connection (gas side)<br />

For refrigerant piping, please<br />

Dimensions 1<br />

2<br />

B Service valve connection (liquid line) refer to the unit specifications. L1 500 Open<br />

C Refrigerant pipe draw-out port<br />

ø88<br />

L2 10<br />

200<br />

D Power cable draw-in port<br />

ø50<br />

L3 100<br />

300<br />

F Anchor bolt hole<br />

M10 x 4 places<br />

L4 10<br />

Open<br />

G Drain hose hole<br />

ø45 x 3 places<br />

H1 1500<br />

–<br />

H Drain discharge port<br />

ø20 x 6 places<br />

H2 No restrictions No restrictions<br />

K * Oil-equalising pipe joint<br />

ø3/8” flare<br />

H3 1000 No restrictions<br />

L Sling holes for haulage or hoisting 180 x 44.7<br />

H4 No restrictions –<br />

*14, 16HP models only<br />

Wall<br />

height H2<br />

Intake<br />

L2<br />

Intake<br />

Service<br />

space<br />

L3<br />

L1<br />

Intake<br />

Installation space<br />

2m overhead clearance required<br />

Wall<br />

height H3<br />

L4<br />

Intake<br />

Wall height H4<br />

Wall height H1<br />

Notes:<br />

(1) The unit must be fixed with anchor bolts.<br />

(2) Leave a 2m or larger space above the unit.<br />

(3) The unit name plate is attached on the lower right corner of<br />

the front panel.<br />

(4) The ports for refrigerant pipe and power cable penetrations<br />

are covered with half-blanks. Please cut off a half-blank with<br />

nippers in using these ports.<br />

(5) Use a ø88 port for refrigerant pipe connection.<br />

(6) Anchor holes marked “L J” (four holes for M10) are for a<br />

renewal installation.<br />

(7) The oil-equalising pipe K should be used when outdoor units<br />

are used in combination. (For 14,16Hp only)<br />

When more than one unit is installed<br />

Wall height<br />

H2<br />

Wall height<br />

H3<br />

L2 L5 L6 L4<br />

L3<br />

Wall height<br />

H2<br />

L1 (Unit front side)<br />

Wall height<br />

H4<br />

Installation example<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

L5<br />

L6<br />

H1<br />

A<br />

500<br />

10<br />

100<br />

10<br />

0<br />

0<br />

1500<br />

B<br />

Open<br />

200<br />

300<br />

Open<br />

400<br />

400<br />

No restrictions<br />

H2<br />

No restrictions<br />

No restrictions<br />

H3<br />

1000<br />

No restrictions<br />

H4<br />

No restrictions<br />

No restrictions<br />

96


Dimensions<br />

All measurements in mm.<br />

FDCH504KXE6, 560KXE6, 560KXE6-K, 615KXE6, 680KXE6<br />

Rear<br />

Dimensions of refrigerant<br />

pipe connection (plan)<br />

141<br />

234<br />

K<br />

B<br />

A<br />

95<br />

140.5<br />

75<br />

142.5<br />

19 726 19<br />

58.5 Anchor bolt positions for F, J<br />

647 58.5<br />

Anchor bolt positions for I<br />

250 850<br />

250<br />

175 1000 175<br />

J F I I F<br />

J I<br />

F<br />

I<br />

J<br />

F<br />

For dimensions of anchor bolt hole<br />

J<br />

<strong>Air</strong> intake<br />

594 85<br />

232 101<br />

57<br />

85<br />

74.5<br />

G<br />

232<br />

D(lower)<br />

185 H<br />

G<br />

148 352 158 342<br />

410 530 235<br />

80.5<br />

71<br />

C<br />

G<br />

140 120<br />

240<br />

296.7<br />

295 174<br />

22 720 22<br />

720<br />

126.2<br />

1350<br />

Drain pipe<br />

D (left)<br />

80<br />

175<br />

7-segment display<br />

inspection port<br />

Signal wire<br />

terminal block<br />

Terminal block<br />

for power cable<br />

connection<br />

2048<br />

682 1155.8<br />

84<br />

6<br />

K<br />

B<br />

A<br />

C (front)<br />

166<br />

169<br />

211<br />

259<br />

291.6<br />

C (right)<br />

172<br />

Instruction plate<br />

104.9<br />

6<br />

86.1<br />

95<br />

D (front)<br />

90<br />

D (right)<br />

C (rear)<br />

172<br />

86.5<br />

220<br />

180<br />

550<br />

180<br />

214<br />

L<br />

44.7<br />

20<br />

Mark Item Installation example<br />

A<br />

B<br />

C<br />

D<br />

F<br />

G<br />

H<br />

K<br />

L<br />

Service valve connection (gas side)<br />

Service valve connection (liquid line)<br />

Refrigerant pipe draw-out port<br />

Power cable draw-in port<br />

Anchor bolt hole<br />

Drain hose hole<br />

Drain discharge port<br />

Oil-equalising pipe joint<br />

Sling holes for haulage or hoisting<br />

For refrigerant piping, please<br />

refer to the unit specifications.<br />

ø100<br />

ø50<br />

M10 x 4 places<br />

ø45 x 3 places<br />

ø20 x 6 places<br />

ø9.52 flare<br />

180 x 44.7<br />

Dimensions<br />

L1<br />

L2<br />

L3<br />

L4<br />

H1<br />

H2<br />

H3<br />

H4<br />

1<br />

500<br />

10<br />

100<br />

10<br />

1500<br />

No restrictions<br />

1000<br />

No restrictions<br />

2<br />

Open<br />

200<br />

300<br />

Open<br />

–<br />

No restrictions<br />

No restrictions<br />

–<br />

Wall<br />

height H2<br />

Intake<br />

L2<br />

Intake<br />

Service<br />

space<br />

L3<br />

L1<br />

Intake<br />

Installation space<br />

2m overhead clearance required<br />

Wall<br />

height H3<br />

L4<br />

Intake<br />

Wall height H4<br />

Wall height H1<br />

Notes:<br />

(1) The unit must be fixed with anchor bolts.<br />

(2) Leave a 2m or larger space above the unit.<br />

(3) The unit name plate is attached on the lower right corner of<br />

the front panel.<br />

(4) The ports for refrigerant pipe and power cable penetrations<br />

are covered with half-blanks. Please cut off a half-blank with<br />

nippers in using these ports.<br />

(5) Use a ø88 port for refrigerant pipe connection.<br />

(6) Anchor holes marked “L J” (four holes for M10) are for a<br />

renewal installation.<br />

(7) The oil-equalising pipe K should be used when outdoor units<br />

are used in combination.<br />

97


R410A<br />

Refresh KX outdoor units<br />

If replacing a used unit with a new one, Refresh KX can reuse existing piping.<br />

Model No.<br />

FDCR224KXE6<br />

FDCR280KXE6<br />

<br />

FDCR-V-KIT-E : Service valve kit<br />

Nominal Cooling Capacity<br />

22.4kW<br />

28.0kW<br />

•Applies to a wide range of pipe sizes (R22, R407C, R410A standard size).<br />

•Meets to a short period of renewal installation.<br />

•Savings on replacement expenses such as scrapping waste material or procuring new pipe.<br />

•Possible to replace the existing unit with a new larger capacity unit.<br />

•Possible to replace plural <strong>system</strong>s with one <strong>system</strong>.<br />

For example:Existing 5HP x 2units can be replaced with a new 10HP x 1unit.<br />

NEW<br />

5HP x 2 10HP x 1<br />

Total length: 510m<br />

To the<br />

first branch:<br />

max 130m<br />

Outdoor unit<br />

Indoor unit<br />

Height difference<br />

50m(outdoor unit above)<br />

40m(outdoor unit below)<br />

40<br />

50<br />

Range of operation<br />

+43ºC<br />

From the first<br />

branch to the<br />

furthest indoor<br />

unit: 90m<br />

Furthest<br />

indoor unit: 160m<br />

Indoor unit<br />

Indoor unit<br />

Max height<br />

difference<br />

between<br />

indoor units:<br />

15m<br />

30<br />

20<br />

10<br />

0<br />

-10<br />

-20<br />

Cooling<br />

+15.5ºC<br />

Heating<br />

-15ºC<br />

-20ºC<br />

Specifications<br />

Item<br />

Nominal horse power<br />

Power source<br />

Nominal capacity<br />

Electrical characteristics<br />

Exterior dimensions<br />

Net weight<br />

Refrigerant charge<br />

Sound pressure level<br />

Refrigerant piping size<br />

Cooling<br />

Heating<br />

Starting current<br />

Power<br />

consumption<br />

Running<br />

current<br />

HxWxD<br />

R410A<br />

Cooling/Heating<br />

Liquid line<br />

Gas line<br />

Capacity connection<br />

Number of connectable indoor units<br />

Cooling<br />

Heating<br />

Cooling<br />

Heating<br />

Model<br />

kW<br />

A<br />

kW<br />

A<br />

mm<br />

kg<br />

kg<br />

dB(A)<br />

mm(in)<br />

%<br />

FDCR224KXE6<br />

8HP<br />

1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB. Heating: Indoor temp. of 20ºCDB, and outdoor temp. of 7ºCDB, 6ºCWB.<br />

2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.<br />

22.4<br />

25.0<br />

5.60<br />

6.03<br />

9.25-8.47<br />

9.85-9.02<br />

58/58<br />

ø19.05( 3 /4")~ø25.4(1")<br />

13<br />

3 Phase 380-415V, 50Hz<br />

5<br />

1675x1080x480<br />

224<br />

11.5<br />

ø9.52( 3 /8")~ø15.88( 5 /8")<br />

50~130<br />

FDCR280KXE6<br />

10HP<br />

28.0<br />

31.5<br />

8.09<br />

8.21<br />

13.22-12.10<br />

13.41-12.28<br />

59/60<br />

ø22.22( 7 /8")~ø28.58(1 1 /8")<br />

16<br />

98


Advanced refresh function<br />

When the existing unit is operable<br />

The existing pipe can be reused by cooling operation only.<br />

Pipe refresh kit and Service valve kit are not required.<br />

1.Implement cooling operation of all indoor units for more than 30 minutes.<br />

2.Implement pump-down after cooling operation.<br />

3.Recover refrigerant and remove the existing outdoor unit and indoor unit.<br />

When the existing unit is not operable<br />

The existing pipe can be reused by washing<br />

operation after connecting Refresh KX, Pipe refresh<br />

kit and Service valve kit.<br />

Connecting and removing of Refresh KX and Pipe<br />

refresh kit is very easy by use of flexible pipe and<br />

flanges.<br />

Dimensions<br />

All measurements in mm.<br />

1.Pipe washing operation is implemented by changing<br />

dip switch on the outdoor unit PCB.<br />

2.Completing washing is monitored via 7-segment<br />

display on the outdoor unit PCB.<br />

3.As washing operation is about 60 minutes, it can<br />

meet to a required short period of renewal<br />

installation.<br />

7-segment display<br />

Piping <strong>system</strong><br />

outdoor unit<br />

compressor accumlator<br />

high efficiency<br />

strainer<br />

oil separator<br />

Pipe refresh kit<br />

heat exchanger<br />

high<br />

efficiency<br />

strainer<br />

Service valve kit<br />

Service valve kit<br />

indoor unit<br />

refrigerant flow<br />

easy local connection (flexbile pipe)<br />

remove the pipe refresh kit after cleaning the used pipe<br />

Pipe refresh kit<br />

(FDCR-KIT-E)<br />

Mark<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F1<br />

F2<br />

F3<br />

F4<br />

G<br />

Item<br />

Service valve connection of the attached connecting pipe (gas side)<br />

Service valve connection (liquid side)<br />

Pipe/cable draw-out hole<br />

Drain discharge hole<br />

Anchor bolt hole<br />

Cable draw-out hole<br />

Cable draw-out hole<br />

Cable draw-out hole<br />

Cable draw-out hole<br />

Connecting position of the local pipe. (gas side)<br />

ø19.05 (3/4") (Flare)<br />

ø12.7 (1/2) (Flare)<br />

4places<br />

ø20 x 4places<br />

M10 x 4places<br />

ø30<br />

ø45<br />

ø22<br />

ø34<br />

ø25.4 (1")(Brazing)<br />

Notes:<br />

(1) It must not be surrounded by walls on the four sides.<br />

(2) The unit must be fixed with anchor bolts. An anchor bolt must not<br />

protrude more than 15mm.<br />

(3) Where the unit is subject to strong winds, lay it in such a direction that the<br />

blower outlet faces perpendicularly to the dominant wind direction.<br />

(4) Leave a 1m or larger space above the unit.<br />

(5) A wall in front of the blower outlet must not exceed the units height.<br />

(6) The model name label is attached on the lower right corner of the front.<br />

(7) Connect the Service valve with local pipe by using the pipe of the<br />

attachment.(Gas side only)<br />

(8) Mark shows the connecting position of the local pipe.(Gas side only)<br />

99


R410A<br />

Mitsubishi Heavy Industries<br />

Mitsubishi Heavy Industries operates a continuous CSR (Corporate Social Responsibility) policy, with a role to realise a sustainable society through it’s<br />

various areas of business.<br />

Creed<br />

•<br />

•<br />

•<br />

We strongly believe that the customer comes first and that we are obliged to be an innovative partner to society.<br />

We base our activities on honesty, harmony, and a clear distinction between public and private life.<br />

We shall strive for innovative management and technological development from an international perspective.<br />

/further information<br />

Reason for Instituting the Creed<br />

In Japan there are many enterprises with their own “creeds” which simply represent their management<br />

concept.<br />

Mitsubishi Heavy Industries, Ltd. has a creed of this type, also. It was instituted in 1970 on the basis of<br />

the policy advocated by Koyata Iwasaki, president of Mitsubishi Goshi Kaisha in the 1920’s, to indicate<br />

the essential attitude of the company, the mental attitude of the employees, and the future directions of<br />

the company.<br />

The reason for instituting the present creed is so that all of us can call to mind our one hundred years of<br />

tradition, and strive for further development in the future.<br />

Issued 1 June 1970<br />

Environment,<br />

Human Rights<br />

and Labour<br />

Contribution to<br />

Society through<br />

Company Business<br />

MHI’s creed was established based on “The Three Corporate Principles” shared by the Mitsubishi Group<br />

from the company’s beginnings. In the spirit of this creed, MHI continues its efforts to fulfil its three<br />

corporate social responsibilities (CSRs): “corporate governance and compliance,” “the environment, human<br />

rights and labour,” and “contribution to society through business activities.”<br />

Corporate Governance and Compliance<br />

Contribution to Society through Company Business<br />

Power &<br />

Energy<br />

MISSION<br />

Supply all areas of the<br />

world with highly<br />

efficient, clean energy<br />

Environment<br />

& Society<br />

MISSION<br />

Help people lead<br />

fulfilled lives<br />

VISION<br />

“MHI, a premier global organization.”<br />

MHI is a global enterprise with a vision<br />

for sustainable growth, living up to the<br />

trust of customers with outstanding<br />

technology, and helping people<br />

worldwide lead safe and<br />

fulfilling lives.<br />

Transportation<br />

& Security<br />

MISSION<br />

A company with expertise in<br />

all modes of transportation,<br />

from land and sea to air<br />

and space, and in the<br />

defence sector<br />

Industries<br />

MISSION<br />

Support manufacturing<br />

activities worldwide<br />

100


The KX6 product range has been developed in compliance with the Mitsubishi Heavy Industries Policy on the Environment.<br />

In order to make the sustainable development of society possible, a basic policy on environmental matters has been established.<br />

Pursuant to the express provision of Section 1 of its creed that “We strongly believe that customers come first and that we are obligated to be an<br />

innovative partner to society,” MHI shall, as a matter of primary importance, strive, through its R&D, manufacturing and other business activities, to play<br />

a useful role in the development of society. To this end, while remaining aware that a business enterprise is a member of society, MHI shall endeavour,<br />

in all aspects of its business activities, to reduce the burden on the environment and shall concentrate and fully utilise its technological capabilities for<br />

the development of technologies and products that will protect the environment, thus contributing to the establishment of a society in which sustainable<br />

development is possible.<br />

In order to realise its basic policy, MHI has set the following seven conduct guidelines.<br />

1. Recognise that environmental protection is top priority in the companyís operations, and encourage the entire company in its endeavours to protect and<br />

improve the environment.<br />

2. Define roles and responsibilities regarding environmental protection by developing and maintaining a corporate organisation designated for environmental<br />

protection, and create and implement corporate policies and procedures on environmental matters.<br />

3. Endeavour to reduce the burden on the environment by preventing pollution, saving resources, saving energy, reducing waste, reusing materials, and recycling<br />

in all aspects of the companyís business activities in R&D, designing, procurement of materials, manufacturing, transportation, use, service and disposal.<br />

4. Endeavour to develop and provide advanced, highly reliable, unique technologies and products that contribute to solving environmental and energy problems.<br />

5. Comply with national and local environmental laws and regulations, beyond mere compliance by enacting, implementing and evaluating voluntary<br />

standards where necessary, and to endeavour to continuously improve and promote environmental protection activities by establishing environmental<br />

goals and targets.<br />

6. Endeavour to protect the environments of foreign countries by carefully examining the consequences of the companyís overseas business operations and<br />

the exportation of its products, and to become actively involved in technological co-operation overseas in areas of environmental protection.<br />

7. Provide environmental training and other programs to enhance the environmental awareness of all company employees, and take steps to expand public<br />

relations activities, such as providing environment-related information to the public and social contribution activities.<br />

Number of offices/plants by region (Consolidated)<br />

as of March, 2011<br />

Europe<br />

Major subsidiaries 12<br />

Asia<br />

Major subsidiaries 40<br />

Japan<br />

Head office & domestic offices 9<br />

Research & development centres 6<br />

Works 14<br />

Major domestic subsidiaries 109<br />

North, Central & South America<br />

Major subsidiaries 23<br />

Africa<br />

Major subsidiary 1<br />

Oceania<br />

Major subsidiaries 2<br />

101


global activity<br />

On the land and sea, in the sky and even in space,<br />

MHIís stage of operations is expanding limitlessly.<br />

We manufacture more than 700 different products which<br />

support various industrial and civil activities in both domestic<br />

and international markets.<br />

Ships, steel structures, power <strong>system</strong>s, machinery for<br />

both industrial and general use, air-conditioners, pollution<br />

reduction and environmental control <strong>system</strong>s, aerospace<br />

<strong>system</strong>s – the MHI product lines which create rich and<br />

comfortable living environments, are as harmonious as<br />

an orchestra.<br />

What creates this harmony is MHIís general technological<br />

expertise developed over more than a century of hard work. We<br />

are highly esteemed in the world for providing high<br />

quality products through untiring technological research<br />

and development. From new energy development and<br />

environmental concerns to the exploration of space, with<br />

the advent of the 21st century MHI is confronting a variety of<br />

issues to ensure the realisation of a society in which there is<br />

harmony between mankind and technology.<br />

• Ultra-High Steel Stacks<br />

• Refuse Incineration Plants<br />

• Night Soil Treatment Plants<br />

• Electrostatic Precipitators<br />

• Flue Gas Desulfurization<br />

System<br />

• Fluidized Incinerators<br />

• CFC Collecting Equipment<br />

• Crude Oil Storage Barges<br />

• LNG Tanks<br />

• Boilers & Turbines<br />

• Oil Production Plants<br />

• Contra-Rotating Propellers<br />

• Thermal Power Plants<br />

• Combined Cycle Plants<br />

• Fuel Cells<br />

• Water Turbines<br />

• Wind Turbines<br />

• Geothermal Power Plants<br />

• PWR Nuclear Power Plants<br />

• Uranium Enrichment<br />

Equipment<br />

• FBRs<br />

• Co-Generation Systems<br />

• Spillway Radial Gates<br />

• Steel Bridges<br />

• Penstocks<br />

• Desalination Plants<br />

• Physical Distribution<br />

Equipment<br />

• Engines<br />

• Unloader & Container Cranes<br />

• Mechanical Parking Facilities<br />

• Integrated Automated Storage<br />

Systems<br />

• Rubber & Tyre Machinery<br />

• Skyrails<br />

• Monorail Cars<br />

• New Transportation Systems<br />

• Passenger Boarding Bridges<br />

• Toll Collection Machine<br />

Systems<br />

• Forklift Trucks<br />

• Helicopters<br />

• <strong>Air</strong>craft<br />

• Railway Maintenance<br />

Equipment<br />

• LNG Carrier<br />

• Container Ships<br />

LOCAL DEVELOPMENT<br />

TRANSPORTATION<br />

ENVIRONMENT<br />

RESOURCES/ENERGY<br />

102


• Chemical Plants<br />

• Wind Tunnel/Experiment<br />

Equipment<br />

• Casting Machines<br />

• Strip Mill<br />

• Cement Plant<br />

• Stepless Variable Speed Gears<br />

• Industrial Robots<br />

• Injection Moulding Machines<br />

• Pulp & Paper Machinery<br />

• Corrugation Machines<br />

• Box Making Machines<br />

• Machine Tools<br />

• Ceiling Recess Packaged <strong>Air</strong><br />

<strong>Conditioners</strong><br />

• Automotive <strong>Air</strong> <strong>Conditioners</strong><br />

• Residential Use Split <strong>Air</strong><br />

<strong>Conditioners</strong><br />

• Refrigeration Units<br />

• Dry Cleaning Machines<br />

• Food Machinery<br />

• Cruise Ships<br />

• Multi-purpose Dome<br />

• Stage Machinery Systems<br />

• Cable Layer<br />

• Printing Machinery<br />

• Oceanographic Research<br />

Ships<br />

• Deep Submergence Research<br />

Vehicles<br />

• Communications Satellite<br />

Rockets<br />

• Space Transportation<br />

• Rockets & Engines<br />

INDUSTRIAL<br />

LEISURE/LIFESTYLE<br />

DEVELOPMENT<br />

INFORMATION SYSTEM<br />

DEFENCE<br />

• Submarines<br />

• Naval Vessels<br />

• Jet Fighters<br />

• Helicopters<br />

• Missiles<br />

• Tanks & Infantry Fighting<br />

Vehicles<br />

103


Before starting use<br />

Heating performance<br />

The heating performance values (kW) described in catalog are the values<br />

obtained by operating at an outdoor temperature of 7C and indoor<br />

temperature of 20 C as set forth in the ISO Standards. As the heating<br />

performance decreases as the outdoor temperature drops, if the outdoor<br />

temperature is too low and the heating performance is insufficient, use other<br />

heating appliances as well.<br />

Indication of sound values<br />

The sound values are the values (A scale) measured in a chamber such as an<br />

anechoic chamber following the ISO Standards. In the actual installation<br />

state, the value is normally larger than the values given in the catalog due to<br />

the effect of surrounding noise and echo. Take this into consideration when<br />

installing.<br />

Use in oil atmosphere<br />

Avoid installing this unit in as atmosphere where oil scatters or builds up,<br />

such as in a kitchen or machine factory.<br />

If the oil adheres to the heat exchanger, the heat exchanging performance<br />

will drop, mist may be generated, and the synthetic resin parts may deform<br />

and break.<br />

Use in acidic or alkaline atmosphere<br />

If this unit is used in acidic atmosphere such as hot spring areas having high<br />

level of sulfuric gases or in alkaline atmosphere including ammonia or<br />

calcium chloride, places where the exhaust of the heat exchanger is sucked<br />

in, or at coastal areas where the unit is subject to salt breezes, the outer plate<br />

or heat exchanger, etc., will corrode. Please ask a dealer or specialist when<br />

you use an air conditioner in places differing from a general atmosphere.<br />

Use in places with high ceilings<br />

If the ceiling is high, install a circulator to improve the heat and air flow<br />

distribution when heating.<br />

Refrigerant leakage<br />

The refrigerant (R410A) used for <strong>Air</strong> conditioner is non-toxic and<br />

inflammable in its original state.<br />

However, in consideration of a state where the refrigerant leaks into the<br />

room, measures against refrigerant leaks must be taken in small rooms<br />

where the tolerable level could be exceeded. Take measures by installing<br />

ventilation devices, etc.<br />

Use in snowy areas<br />

Take the following measures when installing the outdoor unit in snowy areas.<br />

·Snow prevention<br />

Install a snow-prevention hood so that the snow does not obstruct the air<br />

intake port or enter and freeze in the outdoor unit.<br />

·Snow piling<br />

In areas with heavy snow fall, the piled snow could block the air intake<br />

port. In this case, a frame that is 50cm or higher than the estimated snow<br />

fall must be installed underneath the outdoor unit.<br />

Automatic defrosting device<br />

If the temperature is low, and the humidity is high, frost will stick to the<br />

heat exchanger of the outdoor unit. If use is continued, the heating<br />

performance will drop.<br />

The "Automatic defrosting device" will function to remove this frost.<br />

After heating for approx, three to ten minutes, it will stop, and the frost will<br />

be removed. After defrosting, hot air will be blown again.<br />

Servicing the air-conditioner<br />

After the air-conditioner is used for several seasons, dirt will build up in<br />

the air-conditioner causing the performance to drop. In addition to regular<br />

servicing, we recommend the maintenance contract (charged for) by a<br />

specialist.<br />

Safety Precautions<br />

<strong>Air</strong>-conditioner usage target<br />

The air-conditioner described in this catalog is a dedicated cooling/heating<br />

device for human use.<br />

Do not use it for special applications such as the storage of foodstuffs,<br />

animals or plants, precision devices or valuable art, etc.<br />

This could cause the quality of the items to drop, etc.<br />

Do not use this for cooling vehicles or ships. Water leakage or current leaks<br />

could occur.<br />

Before use<br />

Always read the "User , s Manual" thoroughly before starting use.<br />

Installation<br />

Always commission the installation to a dealer or specialist. Improper<br />

installation will lead to water leakage, electric shocks and fires.<br />

Make sure that the outdoor unit is stable in installation. Fix the unit to<br />

stable base.<br />

Usage place<br />

Do not install in places where combustible gas could leak or where there<br />

are sparks.<br />

Installation in a place where combustible gas could be generated, flow or<br />

accumulate, or places containing carbon fibers could lead to fires.<br />

Mitsubishi Heavy Industries, Ltd.<br />

<strong>Air</strong>-Conditioning & Refrigeration Systems<br />

16-5, Konan 2-chome, Minato-ku, Tokyo, 108-8215 Japan<br />

http://www.mhi.co.jp<br />

Our factories are ISO9001 and ISO14001 certified.<br />

Certified ISO 9001 Certified ISO 14001<br />

ISO 14001<br />

Certificate 04104 1998 0813 E5<br />

BIWAJIMA PLANT<br />

Mitsubishi Heavy Industries, Ltd.<br />

<strong>Air</strong>-conditioning & Refrigeration Systems Headquarters<br />

MITSUBISHI HEAVY INDUSTRIES-<br />

MAHAJAK AIR CONDITIONERS CO., LTD.<br />

Mitsubishi Heavy<br />

Industries-Haier (Quingdao)<br />

<strong>Air</strong>-conditioners Co.,Ltd.<br />

BIWAJIMA PLANT<br />

Mitsubishi Heavy Industries, Ltd.<br />

<strong>Air</strong>-conditioning & Refrigeration Systems Headquarters<br />

MITSUBISHI HEAVY INDUSTRIES-<br />

MAHAJAK AIR CONDITIONERS CO.,LTD.<br />

Mitsubishi Heavy<br />

Industries-Haier (Quingdao)<br />

<strong>Air</strong>-conditioners Co.,Ltd.<br />

HB91-12KX01E-A-0<br />

September 2012<br />

R<br />

Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.<br />