FF(UK):10/08/A<br />

VSC®6000<br />

<strong>an</strong> adv<strong>an</strong>ced <strong>workstation</strong> <strong>for</strong> <strong>the</strong> <strong>visual</strong><br />

<strong>examination</strong> of questioned documents<br />

<strong>an</strong>d security documents<br />

● Technology in use by immigration authorities, government<br />

agencies <strong>an</strong>d <strong>for</strong>ensic laboratories worldwide<br />

● Effective on all types of passports <strong>an</strong>d ID cards<br />

● Detects alterations <strong>an</strong>d counterfeits<br />

● Reveals covert security features<br />

● Provides documentary evidence<br />

<strong>for</strong> prosecutions<br />

● Helps generate security alerts<br />

● Comprehensive passport &<br />

b<strong>an</strong>knote reference databases<br />

● Now featuring 'HFi' imaging<br />

technology <strong>for</strong> exceptional<br />

image quality


VSC ® 6000<br />

is <strong>an</strong> <strong>examination</strong> system <strong>for</strong> detecting altered <strong>an</strong>d<br />

counterfeit security documents<br />

The VSC ® 6000 is a high resolution imaging system <strong>for</strong><br />

au<strong>the</strong>nticating passports, visas, ID cards <strong>an</strong>d m<strong>an</strong>y<br />

o<strong>the</strong>r security documents.<br />

The multi-functional <strong>workstation</strong> provides<br />

facilities <strong>for</strong> examining...<br />

● UV activated luminescent features under short, medium<br />

<strong>an</strong>d long wave UV.<br />

● Tampering <strong>an</strong>d photo-substitution under high magnification.<br />

● <strong>an</strong>ti-Stokes security features using intense IR lighting.<br />

● Retro-reflective features with coaxial lighting.<br />

● Embossed stamps under oblique lighting.<br />

● Watermarks using tr<strong>an</strong>smitted lighting.<br />

● OVDs using multi-<strong>an</strong>gled lighting.<br />

● Suspected alterations using differential<br />

infrared absorption <strong>an</strong>d luminescence<br />

properties of inks.<br />

● Embedded personal in<strong>for</strong>mation.<br />

● ICAO coded data.<br />

● Passport & B<strong>an</strong>knote databases<br />

Two reference databases of passports, ID<br />

cards <strong>an</strong>d b<strong>an</strong>knotes issued by 180 countries<br />

provide au<strong>the</strong>ntic images of watermarks,<br />

holograms, UV activated features allowing<br />

direct comparison to samples under <strong>examination</strong>.<br />

Databases are updated monthly <strong>an</strong>d supplied on DVD.<br />

TAMPERING<br />

zoom magnification is essential <strong>for</strong> scrutinising fine detail <strong>an</strong>d to<br />

identify alterations.<br />

validity<br />

5 years, page 2 entry 'Date of expiry'<br />

booklet<br />

c. 125 x 88mm / 4.9 x 3.5 in.<br />

32 pag., pages 2 <strong>an</strong>d 3 not numbered<br />

laminate<br />

page 2, matt laminate with print, not sewn in<br />

photo<br />

integrated, second photo in image perf<br />

COMPREHENSIVE EXAMINATION SYSTEM<br />

High resolution, wide screen, a working gallery <strong>an</strong>d on-screen notepad are just a few of<br />

<strong>the</strong> new features that make document <strong>examination</strong> <strong>an</strong>d comparison much easier with <strong>the</strong> VSC6000.<br />

numbering<br />

6 digits, preceded by 2 letters<br />

page 1 printed<br />

page 2, machine-written<br />

pages 3 - 32, per<strong>for</strong>ated<br />

observations<br />

this passport was first issued February 2001<br />

passports issued since 15 November 2003 must<br />

contain a colour photo<br />

SEARCHABLE DATABASES<br />

Each database contains pictorial examples <strong>an</strong>d written<br />

descriptions of document security features.<br />

ANTI-STOKES SECURITY FEATURES<br />

revealed with high intensity IR lighting.<br />

LUMINESCENT SECURITY FEATURES<br />

embedded in identity cards <strong>an</strong>d passports viewed with<br />

tr<strong>an</strong>smitted or incident UV lighting.<br />

HOLOGRAMS AND OVDs<br />

viewed with <strong>an</strong>gled lighting.<br />

EMBEDDED INFORMATION<br />

revealed with software decoders.


VSC ® 6000<br />

is a comprehensive <strong>workstation</strong> <strong>an</strong>d casework<br />

m<strong>an</strong>agement system <strong>for</strong> questioned document examiners<br />

NEW <strong>an</strong>d IMPROVED features<br />

● NEW 5.0 million pixel FireWire camera <strong>for</strong> high resolution imaging.<br />

● NEW 'HFi' technology <strong>for</strong> improved image quality.<br />

● NEW 30” (75cm) wide screen monitor <strong>for</strong> improved image display.<br />

● NEW x86 zoom r<strong>an</strong>ge providing optical magnification up to x130 (approx).<br />

● IMPROVED field of view, enlarged to 210 x 160mm.<br />

● NEW on-screen note pad <strong>for</strong> report writing.<br />

● NEW image database search facility with keyword search engine.<br />

● IMPROVED 'thumbnail' gallery, enlarged <strong>for</strong> viewing casework images.<br />

● NEW ROI (Region of Interest) image processing – improves <strong>the</strong> effects of image<br />

enh<strong>an</strong>cing software.<br />

● NEW differential absorption imaging - amplifies small differences in <strong>the</strong><br />

spectral absorption characteristics of inks.<br />

● NEW high resolution, real-time grating spectrometer with 9nm FWHM resolution.<br />

● NEW wide field, broad b<strong>an</strong>d infrared illumination <strong>for</strong> examining <strong>an</strong>ti-Stokes<br />

fluorescence.<br />

● IMPROVED side lighting providing more even illumination <strong>for</strong> <strong>the</strong> <strong>examination</strong><br />

of security features.<br />

● NEW 14 LED sc<strong>an</strong>ning array provides sequential <strong>visual</strong>isation of OVDs with<br />

video recording facilities.<br />

● IMPROVED design <strong>for</strong> easier servicing <strong>an</strong>d lamp replacement plus automatic<br />

lamp failure diagnostics.<br />

● NEW e-passport <strong>an</strong>d ICAO card reader.<br />

Differences in infrared absorption reveals <strong>an</strong> alteration<br />

to a document.<br />

Differences in infrared fluorescence reveals <strong>an</strong> alteration<br />

to a document.<br />

Live <strong>an</strong>d stored images c<strong>an</strong> be overlayed <strong>for</strong> <strong>the</strong><br />

comparison of physical characteristics.<br />

Image measurement; comparison of feature areas c<strong>an</strong><br />

provide evidence of alterations or <strong>for</strong>gery.<br />

The image gallery, pictured left, is a fast way to review<br />

all images saved in a casework folder. Drag up to five<br />

images to <strong>the</strong> Preview Windows <strong>for</strong> full screen displays.


VSC ® 6000 Features in brief<br />

Full details of <strong>the</strong>se features c<strong>an</strong> be found in <strong>the</strong> specification section<br />

● 'HFi' IMAGING TECHNOLOGY<br />

An optical system that minimizes spatial<br />

distortion <strong>an</strong>d chromatic aberration<br />

throughout <strong>the</strong> entire magnification<br />

r<strong>an</strong>ge, offering exceptional image quality.<br />

● IMAGING SYSTEM<br />

A FireWire 5 Mpixel CCD colour camera<br />

with zoom magnification up to<br />

x130 (approx).<br />

● FULL RANGE OF LIGHT SOURCES<br />

Includes ultraviolet to infrared incident<br />

<strong>an</strong>d tr<strong>an</strong>smitted <strong>for</strong> <strong>the</strong> <strong>examination</strong> of<br />

fluorescent security features including<br />

<strong>an</strong>ti-Stokes inks, OVDs <strong>an</strong>d retro<br />

reflective images. High intensity<br />

illumination is also provided <strong>for</strong> <strong>the</strong><br />

<strong>examination</strong> of infrared fluorescence <strong>an</strong>d<br />

absorption characteristics of inks.<br />

● GRAPHIC USER INTERFACE<br />

A new, intuitive, on-screen control system<br />

allows <strong>the</strong> operator to navigate <strong>the</strong><br />

system more easily. Magnification, light<br />

sources, filters, image <strong>an</strong>alysis <strong>an</strong>d image<br />

processing functions are selected from<br />

simple on screen icons using <strong>the</strong> PC<br />

mouse.<br />

● INTERACTIVE TUTORIAL<br />

An on-screen, step by step guide to each<br />

facility.<br />

● INTELLIGENT SOFTWARE<br />

VSC ® 6000 ensures compatible<br />

combinations of illumination <strong>an</strong>d imaging<br />

filters automatically. When <strong>the</strong> operator<br />

selects a filter to generate fluorescence,<br />

<strong>the</strong> system automatically selects <strong>the</strong> first<br />

compatible imaging filter to prevent light<br />

leakage that would o<strong>the</strong>rwise mask <strong>the</strong><br />

fluorescence. The operator may override<br />

<strong>the</strong> automatic selection, if required.<br />

● MICROSPECTROMETER<br />

A new high resolution, real-time grating<br />

spectrometer provides absorption,<br />

reflect<strong>an</strong>ce, tr<strong>an</strong>smitt<strong>an</strong>ce <strong>an</strong>d<br />

fluorescence spectra.<br />

● IMAGE MEASUREMENT<br />

A software module that enables<br />

examiners to make a variety of<br />

measurements including dist<strong>an</strong>ces, <strong>an</strong>gles,<br />

areas, circle radii <strong>an</strong>d shape perimeters.<br />

A simple calibration procedure also<br />

enables absolute values to be computed.<br />

● IMAGE PROCESSING AND<br />

ENHANCEMENT<br />

A suite of programs <strong>for</strong> rotating <strong>an</strong>d<br />

reversing a displayed image plus image<br />

enh<strong>an</strong>cement by sharpening, noise<br />

reduction including FFT filters,<br />

background flattening, gamma correction<br />

<strong>an</strong>d contrast stretching.<br />

● IMAGE COMPARISON<br />

A r<strong>an</strong>ge of facilities <strong>for</strong> displaying <strong>the</strong><br />

images of two documents simult<strong>an</strong>eously<br />

including split screen, overlays <strong>an</strong>d<br />

alternate strobe.<br />

● IMAGE INTEGRATION<br />

A variation in <strong>the</strong> infra red fluorescence<br />

emitted by two inks provides a valuable<br />

me<strong>an</strong>s of detecting a fraudulent<br />

alteration to a document. On chip<br />

integration from 8ms to 22s allows <strong>the</strong><br />

examiner to enh<strong>an</strong>ce <strong>an</strong>d differentiate<br />

weakly fluorescent images.<br />

● COLOUR MEASUREMENT<br />

Characterises <strong>the</strong> colour of a selected area<br />

of <strong>an</strong> image in st<strong>an</strong>dard colour<br />

coordinates with displays on chromaticity<br />

charts <strong>for</strong> colour comparisons.<br />

● IMAGE ANNOTATION<br />

Includes text <strong>an</strong>d symbols such as arrows,<br />

lines, boxes <strong>an</strong>d circles.<br />

● ICAO DATA READER<br />

The OCR allows operators to check data in<br />

<strong>the</strong> Machine Readable Zone of passports<br />

<strong>an</strong>d ID cards.<br />

● CASEWORK MANAGEMENT<br />

The system, which is compatible with both<br />

Windows XP <strong>an</strong>d VISTA, allows <strong>the</strong><br />

operator to create casework files <strong>an</strong>d to<br />

store <strong>an</strong>d recall images, including<br />

instrument settings. Features include a<br />

pull-out gallery of recent work, notepad<br />

<strong>an</strong>d a key word search engine.<br />

● PROGRAMMED EXAMINATIONS<br />

The VSC6000 may be pre-programmed<br />

with instrument settings to facilitate<br />

multiple, st<strong>an</strong>dard <strong>examination</strong> tasks,<br />

ensuring consistency in <strong>the</strong> repetitive<br />

<strong>examination</strong> of identical documents such<br />

as cheques.<br />

● EMBEDDED INFORMATION DECODER<br />

(OPTIONAL FEATURE)<br />

Personal in<strong>for</strong>mation invisibly embedded<br />

in photographs is a valuable technique <strong>for</strong><br />

protecting passports against <strong>for</strong>gery.<br />

The operator selects <strong>the</strong> country <strong>an</strong>d <strong>the</strong><br />

VSC ® 6000 automatically applies <strong>the</strong><br />

appropriate decoding system. New coding<br />

systems c<strong>an</strong> be added by <strong>the</strong> operator as<br />

<strong>the</strong>y arise.<br />

Coaxial lighting reveals retro-reflective patterns on<br />

<strong>an</strong> identity card.<br />

Luminescent security features on <strong>an</strong> identity card<br />

seen when viewed with tr<strong>an</strong>smitted UV.<br />

Side by side <strong>examination</strong> of a live image <strong>an</strong>d a<br />

comparison image selected from <strong>the</strong> Working Gallery.<br />

Twin lamps provide orthogonal lighting to enh<strong>an</strong>ce<br />

shadow cast images of <strong>an</strong> embossed stamp.<br />

Sequential images of a b<strong>an</strong>knote OVD using <strong>the</strong><br />

VSC6000's programmed multi-<strong>an</strong>gled illumination.


VSC ® 6000 Specifications in detail<br />

COMPUTER AND PERIPHERALS<br />

All VSC ® 6000s are supplied with <strong>the</strong> latest<br />

computer systems <strong>an</strong>d a 30” (75cm) display.<br />

Please contact our Sales Office specifications.<br />

POWER<br />

Universal input, 85 - 250V, 50/60Hz, 700W.<br />

DOCUMENT CAPACITY<br />

Accommodates documents up to<br />

596mm x 422mm.<br />

IMAGING SYSTEM<br />

Featuring 'HFi' imaging technology <strong>an</strong>d<br />

FireWire digital 5.0 Mpixel CCD colour camera<br />

with 2584 x 1956 output pixels, spectral<br />

response 360 - 1100nm, preset iris positions<br />

<strong>an</strong>d automatic exposure with m<strong>an</strong>ual <strong>an</strong>d<br />

automatic contrast adjustment <strong>an</strong>d auto focus.<br />

IMAGING FILTERS<br />

15 long pass filters in <strong>the</strong> visible <strong>an</strong>d near<br />

infrared with thresholds at 530, 550, 570, 590,<br />

610, 630, 645, 665, 695, 715, 725, 780, 830, 850<br />

<strong>an</strong>d 925nm plus a broadb<strong>an</strong>d pass filter<br />

390-690nm, UV viewing filter 360 - 400nm,<br />

multi-b<strong>an</strong>d calibration filter.<br />

IMAGE DISPLAY<br />

30" (75cm) flat screen colour LCD monitor.<br />

MAGNIFICATION<br />

Zoom r<strong>an</strong>ge of x1.5 to x130 (approx) onscreen<br />

magnification.<br />

Fields of view: 2.5 x 1.9mm to 210 x 160mm.<br />

Digital x2 magnification provides a maximum<br />

magnification up to x200 at full resolution.<br />

(All magnifications <strong>an</strong>d fields of view are approximate<br />

<strong>an</strong>d based upon a 30” (75cm) monitor).<br />

ILLUMINATION MODES:<br />

Ultraviolet, incident flood light<br />

Long wave 365nm peak wavelength,<br />

4 x 9W.<br />

Medium wave 312nm peak wavelength,<br />

2 x 8W.<br />

Short wave 254nm peak wavelength,<br />

2 x 8W.<br />

(Medium <strong>an</strong>d short wave lamps operated with interlocking safety shields)<br />

Ultraviolet, tr<strong>an</strong>smitted flood light<br />

Long wave 365nm peak wavelength,<br />

2 x 9W.<br />

Visible, incident high intensity spot light<br />

250W tungsten halogen lamp with<br />

independent low pass <strong>an</strong>d high pass filters<br />

providing 80 different waveb<strong>an</strong>ds <strong>an</strong>d zoom<br />

lens, providing a broad beam to a focused<br />

spotlight (see table below).<br />

Visible/infrared, incident flood light<br />

4 x 20W halogen lamps + 2 x white 1W LEDs.<br />

Visible/infrared, continuous narrow b<strong>an</strong>d<br />

illumination<br />

100W halogen lamp filtered by a continuous<br />

interference b<strong>an</strong>d pass filter from 400 to<br />

1000nm, operated in 3.5nm steps <strong>an</strong>d with <strong>an</strong><br />

average b<strong>an</strong>d pass width of 40nm.<br />

Visible/infrared, incident background<br />

illumination<br />

2 x 5W inc<strong>an</strong>descent lamps with intensity<br />

control.<br />

OVD illumination<br />

14 x 1W LEDs in horizontal <strong>an</strong>d vertical arrays<br />

(<strong>for</strong> sequential sc<strong>an</strong>ning of OVDs).<br />

Visible, incident coaxial light<br />

11 x 1W white LEDs (illuminates retroreflective<br />

security features).<br />

Visible/infrared, oblique light<br />

2 x 20W halogen, orthogonal, variable height<br />

(creates shadow cast images).<br />

Visible/infrared, tr<strong>an</strong>smitted flood light<br />

4 x 12W inc<strong>an</strong>descent lamps.<br />

Visible/infrared, tr<strong>an</strong>smitted high<br />

intensity spot light<br />

20W halogen lamp, gives 25mm spot.<br />

Infrared, incident light<br />

High intensity broadb<strong>an</strong>d illumination <strong>for</strong><br />

<strong>an</strong>ti-Stokes inks.<br />

IMAGE INTEGRATION<br />

On-chip integration from 8ms to 22 seconds in<br />

33 steps.<br />

COLOUR MEASUREMENT<br />

Measures colour parameters: XYZ, xy, uv, Lab.<br />

Displays data on 1931 <strong>an</strong>d 1960 UCS<br />

chromaticity charts.<br />

MICROSPECTROMETRY<br />

Grating type spectrometer allowing <strong>for</strong> rapid<br />

measurement of absorption, reflect<strong>an</strong>ce,<br />

tr<strong>an</strong>smission <strong>an</strong>d fluorescence spectra. 400 to<br />

1000nm r<strong>an</strong>ge with a resolution of 9nm<br />

FWHM.<br />

IMAGE ANALYSIS<br />

Measurement facilities <strong>for</strong> dist<strong>an</strong>ce, <strong>an</strong>gle <strong>an</strong>d<br />

area measurement, calibrated grids,<br />

user-definable grids. Measurements c<strong>an</strong> be<br />

added to image.<br />

IMAGE ANNOTATION<br />

Editable image <strong>an</strong>notation facilities (text <strong>an</strong>d<br />

various shapes including arrows, lines, boxes <strong>an</strong>d<br />

circles).<br />

IMAGE ENHANCEMENT<br />

Image enh<strong>an</strong>cement functions including<br />

Contrast Stretch, HSL, RGB, Filters,<br />

Equalization, FFT, Gamma Correction, Sharpen.<br />

IMAGE COMPARISON AND<br />

TRANSFORMATIONS<br />

● Side by side comparison of live <strong>an</strong>d stored<br />

images on a vertical or horizontal split<br />

screen, user adjustable screen split position.<br />

● Superimposition of live <strong>an</strong>d stored image<br />

with adjustable mix, 0% to 100% (option<br />

of red/green rendered images <strong>for</strong> extra<br />

clarity).<br />

● Variable speed image strobe between live<br />

<strong>an</strong>d stored image<br />

● Subtraction of live <strong>an</strong>d stored images with<br />

adjustable mix, 0% to 100%<br />

● Mirror reversal modes; left to right reversal<br />

(horizontal) <strong>an</strong>d top to bottom (vertical).<br />

● Pixel value reversal in B&W <strong>an</strong>d colour,<br />

(positive to negative).<br />

● Image rotation through 90°, clockwise or<br />

<strong>an</strong>ticlockwise.<br />

● Reference image c<strong>an</strong> be positioned/rotated<br />

by mouse control.<br />

● Video capture of OVDs.<br />

CASEWORK MANAGEMENT SYSTEM<br />

● Similar file representation to Windows<br />

Explorer with facilities to org<strong>an</strong>ize <strong>an</strong>d<br />

store casework in<strong>for</strong>mation including text,<br />

images, spectra <strong>an</strong>d chromaticity charts.<br />

● Images c<strong>an</strong> be stored with full instrument<br />

settings (type of illumination, camera filter,<br />

integration time, magnification, etc) to<br />

enable <strong>the</strong> operator to recreate previous<br />

<strong>examination</strong> conditions. Instrument is reset<br />

automatically to stored conditions on<br />

dem<strong>an</strong>d.<br />

● Pull-out image gallery of all recent work<br />

allowing comparison with current or<br />

previously stored images. Images may be<br />

saved as BITMAP, JPEG, JPEG2000 or TIF<br />

files.<br />

● Interface to Microsoft Word, notepads <strong>for</strong><br />

making <strong>an</strong>d reviewing notes.<br />

● Comprehensive image search facility.


VSC ® 6000 Specifications in detail - continued<br />

ICAO DATA READER<br />

The optical character reader deciphers, checks<br />

<strong>an</strong>d displays <strong>the</strong> in<strong>for</strong>mation held in <strong>the</strong><br />

machine readable zone of <strong>the</strong> document.<br />

H<strong>an</strong>dles ICAO accredited <strong>an</strong>d similar <strong>for</strong>mat<br />

codes.<br />

LANGUAGES<br />

M<strong>an</strong>y l<strong>an</strong>guages are available, including<br />

interactive Help with <strong>the</strong> F1 key.<br />

REMOTE OPERATION<br />

The VSC ® 6000 is designed to facilitate remote<br />

operation using a high speed link. For fur<strong>the</strong>r<br />

in<strong>for</strong>mation please contact our Sales Office.<br />

PROGRAMMED EXAMINATIONS<br />

Allows <strong>the</strong> VSC ® 6000 to be pre-programmed<br />

with a number of fixed instrument settings<br />

including magnification, illumination <strong>an</strong>d<br />

filters to create a sequence of st<strong>an</strong>dard<br />

<strong>examination</strong> tasks.<br />

AFTER SALES SUPPORT<br />

Foster & Freem<strong>an</strong> are always pleased to offer<br />

advice, installation, training <strong>an</strong>d on-site<br />

mainten<strong>an</strong>ce world wide. Please contact our<br />

Sales Office <strong>for</strong> fur<strong>the</strong>r in<strong>for</strong>mation. VSC ® 6000<br />

software updates are supplied free of charge<br />

<strong>for</strong> 2 years.<br />

VSC ® 6000 Optional accessories<br />

E-PASSPORT & ICAO READER<br />

Product Code: V6/EPRT<br />

Desktop e-document reader <strong>for</strong> reading<br />

ISO14443-4 documents such as electronic<br />

passports <strong>an</strong>d identity cards with a Machine<br />

Readable Zone or ICAO coded data.<br />

EMBEDDED PERSONAL<br />

INFORMATION DECODERS<br />

Product Code: V6/IPI<br />

Software to detect <strong>an</strong>d display imbedded<br />

personal in<strong>for</strong>mation on passports <strong>an</strong>d ID<br />

cards, including pre-sets <strong>for</strong> different<br />

passports (<strong>an</strong>d ability to save future<br />

settings).<br />

IDENTITY DOCUMENT DATABASE<br />

Product Code: KD/IDENTITY<br />

A reference database of over 1,400 passports,<br />

driving licences <strong>an</strong>d identity cards from 180<br />

countries. Data includes descriptions <strong>an</strong>d over<br />

20,000 images of watermarks, holograms <strong>an</strong>d<br />

UV features. In<strong>for</strong>mation is supplied on DVD<br />

by <strong>an</strong>nual subscription with updates issued<br />

monthly.<br />

BANKNOTE DATABASE<br />

Product Code: KD/BANKNOTE<br />

A reference database of over 4,500 b<strong>an</strong>knotes<br />

from 180 countries. Data includes over 70,000<br />

images <strong>an</strong>d descriptions of watermarks,<br />

holograms <strong>an</strong>d UV features. In<strong>for</strong>mation is<br />

supplied on DVD by <strong>an</strong>nual subscription with<br />

updates issued monthly.<br />

www.fosterfreem<strong>an</strong>.com<br />

Head Office & UK Sales Office:<br />

Foster & Freem<strong>an</strong> Ltd.<br />

25 Sw<strong>an</strong> L<strong>an</strong>e, Evesham,<br />

Worcestershire, WR11 4PE. UK<br />

+44 (0) 1386 41061<br />

+44 (0) 1386 765351<br />

www.fosterfreem<strong>an</strong>.com<br />

sales@fosterfreem<strong>an</strong>.com<br />

USA Sales Office: For enquiries from <strong>the</strong> USA <strong>an</strong>d C<strong>an</strong>ada<br />

888 445 5048<br />

www.fosterfreem<strong>an</strong>.com<br />

888 445 5049<br />

usoffice@fosterfreem<strong>an</strong>.com<br />

AUXILIARY VIDEO MICROSCOPE<br />

Product Code: V6/CV/6K<br />

An imaging system<br />

that provides <strong>an</strong><br />

additional high<br />

magnification input<br />

into <strong>the</strong> VSC ® 6000.<br />

The microscope<br />

package includes <strong>the</strong><br />

V6/CAMFW 5 Mpixel<br />

high resolution colour<br />

video camera, new<br />

Leica M205C<br />

microscope with<br />

phototube, 1x<br />

objective, eye pieces<br />

<strong>an</strong>d multi – <strong>an</strong>gle LED illumination. Suitable <strong>for</strong><br />

<strong>the</strong> <strong>examination</strong> of A4 documents.<br />

Features<br />

● 20.5:1 zoom r<strong>an</strong>ge working<br />

dist<strong>an</strong>ce 61.5mm.<br />

● Eyepiece magnification: x7.8 to x160 fields of<br />

view 59mm to 2.88mm.<br />

● On-screen magnification (30”) monitor x54<br />

to x1108 fields of view 30.9mm to 1.51mm.<br />

Leica microscope<br />

● M205C optics carrier.<br />

● Trinocular tube 100%, M series.<br />

● Video-/photo objective 1.0x.<br />

● C-mount adaptor 1 x delta.<br />

● Eyepiece 10x/23B, adjustable x2.<br />

● Universal microscope carrier AX.<br />

● Focus drive coarse/fine.<br />

● Light base with <strong>an</strong>ti-shock feet.<br />

● LED5000 MCI multi <strong>an</strong>gle LED illumination<br />

module.<br />

● Objective Pl<strong>an</strong>apo 1.0x, M series.<br />

● Power cable.<br />

Foster & Freem<strong>an</strong> Ltd reserve <strong>the</strong> right to alter <strong>the</strong> specification<br />

of <strong>the</strong> VSC ® 6000 or <strong>an</strong>y accessories without prior notice.<br />

Appointed Agent:<br />

AUXILIARY HIGH RESOLUTION<br />

VIDEO CAMERA<br />

Product Code: V6/CAMFW<br />

A 5.0 Mpixel CCD colour digital camera that<br />

provides <strong>an</strong> alternative image input to <strong>the</strong><br />

VSC ® 6000 system. It c<strong>an</strong> be mounted on to <strong>an</strong>y<br />

suitable microscope <strong>an</strong>d connected to <strong>the</strong><br />

FireWire camera port on <strong>the</strong> VSC ® 6000 PC.<br />

Image integration r<strong>an</strong>ges from 8ms to 22<br />

seconds. Images input to <strong>the</strong> VSC ® 6000 may be<br />

processed under <strong>the</strong> VSC ® software including<br />

archiving, feature measurement, comparative<br />

display <strong>an</strong>d image enh<strong>an</strong>cement.<br />

TRANSLATION STAGE<br />

Product Code: V6/TRANS<br />

An XY tr<strong>an</strong>slation stage is now<br />

available <strong>for</strong> <strong>the</strong> VSC ® 6000<br />

document <strong>examination</strong> system<br />

to allow precise positioning of a<br />

document at high magnification.<br />

NEW<br />

PRODUCT<br />

allows <strong>for</strong><br />

precise<br />

document<br />

alignment<br />

The stage is m<strong>an</strong>ually adjustable, with a travel<br />

of +/- 20mm in both X <strong>an</strong>d Y directions, <strong>an</strong>d is<br />

tr<strong>an</strong>sparent from long wave UV to near<br />

infrared to facilitate tr<strong>an</strong>smitted light<br />

<strong>examination</strong>s.<br />

The tr<strong>an</strong>slation stage c<strong>an</strong> be easily fitted to <strong>the</strong><br />

VSC ® 6000 by <strong>the</strong> operator.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!