<strong>Machinery</strong> Health TM Management<br />

<strong>CSI</strong> <strong>4500</strong>M <strong>Machinery</strong> Health <strong>Monitor</strong> Power Supply Card<br />

Specifications PN A4532AC<br />

B4532AC Specifications<br />

Input Power<br />

120 – 240 VAC 50/60 Hz<br />

System Power Dissipation<br />

< 25 watts for 32 signals, 16 tachometers,<br />

16 relays<br />

< 55 watts with optional fan tray and aux<br />

power fully loaded<br />

< 80 watts with optional transient processor<br />

Optional Accessory Output Power -24 vdc @ 0.6 A for displacement probes<br />

Supplies Power to the Rack<br />

Supplies Power to<br />

Auxiliary Equipment<br />

5 vdc, 12 vdc, 24 vdc, 3.3 vdc, -12 vdc<br />

+24 vdc, 0.3 A output for optional fan tray<br />

±24 vdc, 0.6 A auxiliary output for displacement<br />

transducers or other<br />

<strong>CSI</strong> <strong>4500</strong>M <strong>Machinery</strong> Health <strong>Monitor</strong> Fan Tray<br />

Specifications PN B<strong>4500</strong>FT<br />

B<strong>4500</strong>FT Specifications<br />

The fan tray is intended to be used where ambient air temperature around the<br />

stainless steel enclosure of the <strong>CSI</strong> <strong>4500</strong> rack is between 110°F and 120°F.<br />

When ordered with a new <strong>CSI</strong> <strong>4500</strong> <strong>Monitor</strong>, the fan tray will be delivered<br />

installed<br />

Power to the fan tray is provided by a fan tray power auxiliary output from<br />

the front panel of the Power Supply card of the <strong>CSI</strong> <strong>4500</strong> <strong>Monitor</strong>.<br />

NOTE: In conditions above 120°F ambient, active cooling or conditioned<br />

plant air should be installed.<br />

NOTE: Fan tray required with the <strong>CSI</strong> <strong>4500</strong>T. The <strong>CSI</strong> <strong>4500</strong>T is the <strong>CSI</strong><br />

<strong>4500</strong>M with the transient option. The <strong>CSI</strong> <strong>4500</strong>T should be installed in a control<br />

room / computer room environment not to exceed 86F or 30C<br />

Page 13