12.07.2015 Views

CLD 64 - Eco Physics

CLD 64 - Eco Physics

CLD 64 - Eco Physics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NITROGEN OXIDE ANALYZERECO PHYSICS <strong>CLD</strong> <strong>64</strong>• Compact design• Internal ozonegenerator andscrubber• Molybdenum or <strong>CLD</strong> 66steel converter forNO X detection• Four freelyselectable measurementranges <strong>CLD</strong> <strong>64</strong>• Operation andcontrol via keypador personal computer• Mobile DC operation<strong>CLD</strong> 62Application examplesMeasurement ofpollutants (fixedand mobile stations)Outdoor NO 225 ppm monitoringSeries checks andquality controlEfficiency control on100 ppm DeNO X installationsTotal nitrogenmonitoring (TN)5000 ppmThe new <strong>CLD</strong> <strong>64</strong> nitrogen oxide analyzer is the economicalsolution for the continuous measurement of NO, NO 2 and NO Xconcentrations even in the low parts per billion!Outdoor NO 2 and NO Xmonitoring.We show you even smallestvariationsFor years ECO PHYSICS has been oneof the leading firms in pollutant measurement.Our analyzers come into use,wherever concentrations of nitrogen oxidecompounds have to be measured.Either integrated into entire productionprocesses and systems, or asstand-alone devices in monitoring stations,they continuously deliver the exactNO, NO 2 and NO X values you require.The design of the instrument isoptimized for rack mount and standaloneapplications.User-friendlinessThe development of an ECO PHYSICSanalyzer always includes full user comfort.The user can adapt the operationaccording to his needs and applicationsby selection of predefined settingsvia the keypad and remotely from a PC.Warning and error messages aredisplayed coded and in full text. Theanalyzer guides the user step by step toreturn to normal operation.Maintenance simply means annualreplacement of filters and membranesbesides the consumables required byspecial sampling conditions.Quality controls inproduction processes.Mobile measurementstations.<strong>Eco</strong>nomical solutionThe <strong>CLD</strong> <strong>64</strong> fulfils the requirements ofoutdoor NO 2 and total NO X monitoringin fixed or mobile stations. Detectingand monitoring of smallest variationsof NO/NO X concentrations is oneof the key features. The fast responseand lag time in less than a second isunique of its class.NO 2 and total NO X is measuredby molybdenum or an optional steelconverter.Easy calibrationCalibration is quickly and automaticallycarried out. This extremely useful featureeliminates the potential risk of erroneouscalibrations.Compact and modular designThe <strong>CLD</strong> <strong>64</strong> is the most compact unit ofits class. Thanks to the totally modularlayout and integrated ozone generatorand scrubber it is designed for a multitudeof applications.


SpecificationsMeasuring rangesMin. detectable concentrationNoise at zero point (1)LagtimeRise time (0–90%)Temperature rangeHumidity toleranceSample flow rateInput pressureDry air use for O 3generatorPower requiredSupply voltagefour freely selectable rangesfrom 0.5 to 100 ppm2 ppb1 ppb1 sec1 sec5–40°C5–95% rel. h(non-condensing, ambient airand sample gas)300 ml/minambientinternally generated (no externalsupply gas required)250 VA, externalmembrane pump 250 VA100–230 V/50–60 Hz,external power supply<strong>CLD</strong> <strong>64</strong>Dimensions height: 133 mm (5 1 / 4 )width: 430 mm (17)depth: 455 mm (18)Weight13 kg (29 lb) without pumpDelivery includes<strong>CLD</strong> <strong>64</strong> analyzer, external powersupply, power cable, vaccumpump, operator’s manualStandard <strong>CLD</strong> <strong>64</strong> NO/NO X analyzer with internalmolybdenum converterOptions S steel converterIO analog I/O interface(dual output)L LANDC 24 V operation incl.DC vacuum pumpR rack mount slidesF inlet filter© ECO PHYSICS AG, Switzerland 2007–1/2InterfaceRS 232; LAN (optional)Analog output (optional)4–20 mA into 500 max.;0–1 V; 0–10 VECO PHYSICS reserves the right to change these specificationswithout notice.Flow diagramambient airinletsample gasinletair filterdryerozone generatorozone restrictorNOreaction chambersample gasrestrictorNO 2converterreactor pressure sensorozone scrubberexternalvacuum pumpECO PHYSICS AG · BUBIKONERSTRASSE 45 · CH-8635 DUERNTEN · TEL. +41 55 220 22 22 · FAX +41 55 220 22 55 · INFO@ECOPHYSICS.COMWWW.ECOPHYSICS.COM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!