You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Emergency Lighting<br />
Emergency lighting is a vital and necessary safety requirement for most building types. The safety it provides for occupants is<br />
paramount and not negociable.<br />
Product Safety<br />
• All Concord fixtures carry the CE mark. This is a legal requirement<br />
which indicates that it is designed and tested to conform to BS EN<br />
60.598 2-22 and is manufactured in accordance<br />
with the quality system BS EN ISO 9001:2000 under certificate number<br />
FM01687.<br />
• Any emergency lighting fixture conversion other than by Concord to a<br />
CE marked fixture invalidates this CE marking and its associated<br />
legal protection.<br />
Emergency Lighting Equipment<br />
This comprises an inverter plus a set of batteries, which conform to BS EN<br />
60.598 2-22 and may be mounted:<br />
• Integral within the fixture (self contained – integral).<br />
• Remote from, but within 1 metre of, the fixture (self contained remote).<br />
Non-maintained Operation<br />
In this mode of operation the emergency lighting lamps are not normally<br />
energized. An automatic monitoring and switching system is provided to<br />
switch on the emergency lighting if the normal supply is interupted.<br />
Maintained Operation<br />
• A single lamp is used for both general and emergency modes.<br />
• In multi-lamp fixtures only one lamp will be used for the provision of<br />
emergency illumination.<br />
• Emergency lighting is provided for at least 3 hours.<br />
(1 hour duration available to special order).<br />
Maintained Remote Emergency Control<br />
The majority of Concord maintained emergency fixtures are supplied with<br />
integral emergency control gear. Where the housing design precludes<br />
integral gear a remote control box is provided complete with connection<br />
cables.<br />
420 TECHNICAL<br />
Product Combined Operation (also known as Sustained)<br />
• Separate lamps provide general and emergency illumination.<br />
• Emergency lighting is provided for at least 3 hours. (1 hour duration<br />
available to special order).<br />
Self-testing<br />
Automatic self-testing and monitoring of Concord fixtures is available to<br />
special order on a project basis.<br />
Central Battery<br />
Concord fixtures for use with a central battery system are available to<br />
special order on a<br />
project basis.<br />
LED Emergency<br />
Concord are at the forefront of Emergency LED technology with a broad<br />
range of product solutions;<br />
Lytebeam LED Emergency<br />
See page 287<br />
Lyteframe Suspended<br />
LED Emergency fitting<br />
See page 257<br />
Lytebeam LED Emergency<br />
See page 287<br />
Lytespan 3 LED Emergency<br />
module<br />
See page 286