Probe Start, Pulse Start and E-<strong>Ballast</strong>s<br />

TECHNICAL POWERPOINT


INCOMPATIBILITY<br />

If a consumer bought a stereo, <strong>the</strong>y’d expect <strong>the</strong> system<br />

components to be compatible.<br />

If a consumer buys a lighting system, <strong>the</strong>y would also expect<br />

<strong>the</strong> system components to work toge<strong>the</strong>r properly.<br />

What if consumers were intentionally, or ignorantly, sold a<br />

mis-matched lighting system that was sure to fail?<br />

Electronic ballast and probe-start lamp failures have been<br />

happening for almost 10 years.


PROBLEM SOLVING<br />

Recognizing that lamp/ballast conflicts were<br />

running amok in <strong>the</strong> industry, Solistek hired <strong>the</strong><br />

world’s leading light and e-ballast engineering<br />

group, GAS Technologies, to uncover <strong>the</strong> hidden<br />

truths behind chronic electronic ballast and<br />

probe-start lamp failures.


Metal Halide magnetic ballasts have 2 main components.<br />

1 Transformer & 1 Capacitor


HPS <strong>Ballast</strong>s have a transformer, a capacitor and an ignitor


Traditional metal halide lamps<br />

use probe-start technology.<br />

To start <strong>the</strong> lamp, a discharge is<br />

created between <strong>the</strong> starting probe<br />

electrode and <strong>the</strong> operating<br />

electrode.<br />

The electrons travel across <strong>the</strong> arc<br />

tube to <strong>the</strong> o<strong>the</strong>r operating electrode<br />

to start <strong>the</strong> lamp.<br />

Pulse start metal halide lamps do<br />

not have a starting probe and require a<br />

1-5kv ignition instead.<br />

After <strong>the</strong> lamp is started, <strong>the</strong> bi-metal<br />

switch opens up and takes <strong>the</strong><br />

starting probe electrode out of <strong>the</strong><br />

circuit.<br />

The lamp has to cool down before<br />

that bi-metal switch will close again,<br />

allowing <strong>the</strong> lamp to restart properly.


IMPROPER LAMPS CAN BREAK BALLASTS<br />

50/60 Hertz Probe Start metal halide lamps should<br />

never be used on high frequency electronic ballasts.<br />

When <strong>the</strong> lamp fails, <strong>the</strong> ballast will try to re-start it.<br />

When <strong>the</strong> bi-metal switch is open, <strong>the</strong> lamp wont restart.<br />

The electronic ballast will be damaged trying to<br />

continually restart a lamp that won’t restart until <strong>the</strong><br />

bi-metal switch closes.


SWITCHABLE BALLASTS<br />

There’s a switch on <strong>the</strong>se magnetic ballasts that can be set for<br />

MH (metal halide) or HPS (high pressure sodium).<br />

The switch ei<strong>the</strong>r puts <strong>the</strong> ignitor in <strong>the</strong> circuit or takes it out<br />

HPS lamps require <strong>the</strong> ignitor, Probe Start MH lamps don’t.


QUESTIONS<br />

Why are <strong>the</strong>re no “switchable” electronic ballasts?<br />

Fact: HPS lamps need an ignitor, and probe start MH lamps don’t.<br />

Why do <strong>the</strong> majority of high frequency e-ballast makers claim<br />

consumers can use probe start MH lamps on <strong>the</strong>ir ballasts?<br />

If lamp & ballast companies understand this fact, <strong>the</strong>y didn’t share<br />

that information with consumers to avoid lamp & ballast failures.<br />

If <strong>the</strong>y didn’t understand this fact, <strong>the</strong>n it’s just poor engineering.


CONSUMER DIS-SERVICE<br />

The two largest US distributors of indoor garden lighting<br />

have known about <strong>the</strong> incompatibility of probe start MH<br />

lamps and e-ballasts for many years, but continue to sell<br />

<strong>the</strong>m toge<strong>the</strong>r and never inform <strong>the</strong>ir customers.<br />

In <strong>the</strong> end, <strong>the</strong> customer suffers from having to deal with<br />

mismatched lighting components and premature failure of<br />

<strong>the</strong>ir gear.<br />

The growers crop also suffers because lighting system<br />

failures can be devastating to plants.


METAL HALIDE LAMPS YOU SHOULD NOT USE<br />

ON HIGH FREQUENCY ELECTRONIC BALLASTS<br />

SunMaster<br />

(Probe Start)<br />

Plantmax<br />

(Probe Start)


METAL HALIDE LAMPS YOU SHOULD NOT<br />

USE ON HIGH FREQUENCY ELECTRONIC BALLASTS<br />

Venture brand lamps<br />

(Probe Start)<br />

Hortilux Blue<br />

(Probe Start)


Pulse Start MH Lamps you can use on<br />

Solistek Electronic <strong>Ballast</strong>s