POULTRY<br />

<strong>F37</strong> CLIMATE CONTROLLER<br />

Exhaust<br />

• Maximum 10 relays controlled, optionally combined with a linear fan control (Combi or EC-<br />

Combi).<br />

• Linear Fan control enables to control controllable fans (via triac, frequency controller, EC-fans,<br />

ITM) or modulating ON/OFF fans. Rotation (changing between fans) can be used with<br />

modulating fans.<br />

• Up to maximum 4 ITM’s can be controlled using the I/O network.<br />

• Separate vortex damper control, linked to linear exhaust using a settable factor.<br />

Inlet control<br />

• 2 Inlet controls (2 zones) to control inlets or valves using the same setting. The valves can<br />

mutually be corrected based on temperature difference.<br />

• 1 Tunnel inlet. Separate inlet control to control a tunnel shutter or curtain.<br />

Curve<br />

• The following settings can be programmed in a curve (maximum 20 setpoints):<br />

- Day number<br />

- House temperature<br />

- Extra temperature (e.g. for heating)<br />

- Desired RH<br />

- Animal weight<br />

- Minimum ventilation (in m 3 /kg/h)<br />

- Maximum ventilation (in % or a tunnel position)<br />

Heating / cooling / humidification<br />

• 3 Heating controls, ON/OFF, time modulating, analog, based on their own sensor and linked<br />

to:<br />

- the house temperature or<br />

- an extra temperature<br />

• 2 Cooling control, ON/OFF or time modulating, based on their own sensor and linked to:<br />

- the house temperature or<br />

- the house temperature + bandwidth or<br />

- an extra temperature or<br />

- the first tunnel position<br />

• 1 Humidification control, ON/OFF or time modulating based on relative humidity in the house.<br />

• Heat demand through F-Net; in combination with a central heating control (e.g. F21).<br />

• OptiSec® control<br />

Time clocks and registration<br />

• 1 Feed clock enabling to enter maximum 24 start and stop times for feeding. Feed<br />

consumption is registered for a settable time interval (Management & Monitoring ® ), of today,<br />

yesterday, day before yesterday and total. A pulsed weighing system or external weighing<br />

systems generating pulses (e.g. directly on an auger) can be used for registration. Feed flow<br />

(under- and overflow) alarm and maximum runtime alarm.<br />

• 1 Water clock enabling to enter maximum 24 start and stop times for water dosage. Water<br />

consumption is registered for a settable time interval (Management & Monitoring ® ), of today,<br />

yesterday, day before yesterday and total. A water meter can be used for the water<br />

registration. Water flow (leakage, under- and overflow) alarm.<br />

• 8 Light clocks enabling to enter maximum 24 start and stop times. Setting possibilities:<br />

increase/decrease times (dimmer functions), settable light intensity (with light meter) and<br />

connection to light curve.<br />

• 4 Time clock enabling to enter maximum 24 start and stop times. This time clock has several<br />

applications, but no registration functions.<br />

4-4-12 / All rights reserved PAGE <strong>04</strong>-<strong>31</strong>-2