POULTRY<br />

<strong>F42</strong> FEED WEIGHER<br />

Standard I/O<br />

IOB.4<br />

• 4 analog inputs<br />

• 4 relays, voltage free<br />

• 1 alarm relay<br />

• 4 0-10V voltage outputs<br />

• 4 digital inputs for the registration inputs<br />

Wiring<br />

FRM.8<br />

• 8 relays, voltage free<br />

<strong>F42</strong>.2<br />

DI.4<br />

• 4 digital inputs for the registration inputs<br />

Power<br />

3 x 2,5 mm 2 Alarm relay<br />

2 x 0,8 mm (0,5 mm 2 )<br />

2 x 0,8 mm (0,5 mm 2 )<br />

2 x 0,8 mm (0,5 mm 2 )<br />

2 x 0,8 mm (0,5 mm 2 )<br />

Analog input (4x)<br />

Digital input (4x)<br />

Analog output (4x)<br />

Relay output (12x)<br />

2 x 0,8 mm (0,5 mm 2 )<br />

I/O-net*<br />

24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />

WU.70i<br />

or<br />

I/O-net*<br />

24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />

ILM.c1<br />

(option)<br />

6 x 0,8 mm<br />

(0,5 mm 2 )<br />

shielded,<br />

max. 50mtr.<br />

Connection box weighbar<br />

I/O-net*<br />

24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />

FNet*<br />

**<br />

IRM.16 / IDM.16<br />

(option)<br />

Relay output (16x) /<br />

Digital input (16x)<br />

Network communication<br />

Technical specifications<br />

* Greenlink: 2 x 0,8 mm 2 twisted pair<br />

** Maximum 30 F-net modules in 1 network<br />

Power supply 45W<br />

Power supply<br />

Mains supply<br />

Mains frequency<br />

Maximum power consumption<br />

90Vac – 264Vac<br />

50/60Hz<br />

45VA<br />

28-02-11 / Modifications reserved PAGE 04-55-04