F42 EasyBlend⢠feed weigher, 1 house F42.2 ... - Farmi Tilatech Oy
F42 EasyBlend⢠feed weigher, 1 house F42.2 ... - Farmi Tilatech Oy
F42 EasyBlend⢠feed weigher, 1 house F42.2 ... - Farmi Tilatech Oy
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
POULTRY<br />
<strong>F42</strong> FEED WEIGHER<br />
Standard I/O<br />
IOB.4<br />
• 4 analog inputs<br />
• 4 relays, voltage free<br />
• 1 alarm relay<br />
• 4 0-10V voltage outputs<br />
• 4 digital inputs for the registration inputs<br />
Wiring<br />
FRM.8<br />
• 8 relays, voltage free<br />
<strong>F42</strong>.2<br />
DI.4<br />
• 4 digital inputs for the registration inputs<br />
Power<br />
3 x 2,5 mm 2 Alarm relay<br />
2 x 0,8 mm (0,5 mm 2 )<br />
2 x 0,8 mm (0,5 mm 2 )<br />
2 x 0,8 mm (0,5 mm 2 )<br />
2 x 0,8 mm (0,5 mm 2 )<br />
Analog input (4x)<br />
Digital input (4x)<br />
Analog output (4x)<br />
Relay output (12x)<br />
2 x 0,8 mm (0,5 mm 2 )<br />
I/O-net*<br />
24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />
WU.70i<br />
or<br />
I/O-net*<br />
24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />
ILM.c1<br />
(option)<br />
6 x 0,8 mm<br />
(0,5 mm 2 )<br />
shielded,<br />
max. 50mtr.<br />
Connection box weighbar<br />
I/O-net*<br />
24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />
FNet*<br />
**<br />
IRM.16 / IDM.16<br />
(option)<br />
Relay output (16x) /<br />
Digital input (16x)<br />
Network communication<br />
Technical specifications<br />
* Greenlink: 2 x 0,8 mm 2 twisted pair<br />
** Maximum 30 F-net modules in 1 network<br />
Power supply 45W<br />
Power supply<br />
Mains supply<br />
Mains frequency<br />
Maximum power consumption<br />
90Vac – 264Vac<br />
50/60Hz<br />
45VA<br />
28-02-11 / Modifications reserved PAGE 04-55-04