F42 EasyBlend⢠feed weigher, 1 house F42.2 ... - Farmi Tilatech Oy
F42 EasyBlend⢠feed weigher, 1 house F42.2 ... - Farmi Tilatech Oy
F42 EasyBlend⢠feed weigher, 1 house F42.2 ... - Farmi Tilatech Oy
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
POULTRY<br />
<strong>F42</strong> FEED WEIGHER<br />
Contents<br />
<strong>F42</strong> EasyBlend <strong>feed</strong> <strong>weigher</strong>, 1 <strong>house</strong><br />
<strong>F42</strong>.2 EasyBlend <strong>feed</strong> <strong>weigher</strong>, 2 <strong>house</strong>s<br />
Application _________________________ 1<br />
Features __________________________ 1<br />
Concept ___________________________ 2<br />
Screen examples ___________________ 3<br />
Options ___________________________ 3<br />
Standard I/O _______________________ 4<br />
Wiring ____________________________ 4<br />
Technical specifications _____________ 4<br />
A7022119<br />
A7022120<br />
Application<br />
The <strong>F42</strong> activates the EasyBlend concept.<br />
EasyBlend uses a batch <strong>weigher</strong> positioned between the silo and the hoppers in the <strong>house</strong>.<br />
EasyBlend is specially for situations where 1 or 2 ingredients, usually wheat, are mixed with a<br />
core <strong>feed</strong>. This concept is not suitable for preparing <strong>feed</strong> yourself.<br />
The system consists of the <strong>F42</strong> control computer and a <strong>weigher</strong>. The entire process is accurately<br />
controlled, from preparing the <strong>feed</strong> in the batch <strong>weigher</strong>, filling the hoppers in the <strong>house</strong> right up<br />
to supplying the <strong>feed</strong>ing lines in the <strong>house</strong>.<br />
The <strong>F42</strong> controls 1 (<strong>F42</strong>) or 2 (<strong>F42</strong>.2) <strong>house</strong>s with maximum 4 silos and registers the consumption<br />
of 5 <strong>feed</strong> types. It is also possible to mix two <strong>feed</strong> types or cereals to reduce <strong>feed</strong> costs and<br />
to control the growth of your animals more accurately.<br />
Features • Accurate control of the <strong>feed</strong>ing process from silo to pan<br />
• Possibility to mix wheat<br />
• Unrestricted or rationed <strong>feed</strong>ing<br />
• Several <strong>feed</strong>ing cycles per 24 hours (8 maximum).<br />
• Stock control<br />
• Registration of water consumption<br />
• A <strong>feed</strong> curve enables the daily <strong>feed</strong> amount to be programmed (maximum 10 <strong>feed</strong> curves<br />
with 20 bending points).<br />
• Timer functions for water, light or <strong>feed</strong>. Water, <strong>feed</strong> and light are always geared to one<br />
another.<br />
• 8 extended light clocks, with ON/OFF control, dimmer function, including light measurement<br />
and control.<br />
• EasyBlend perfectly fits in existing situations.<br />
• When the silo is empty, EasyBlend automatically switches to another silo with the same<br />
<strong>feed</strong> type.<br />
• To prevent premature switching to another <strong>feed</strong> type with bridge forming, EasyBlend uses<br />
the day number to check if switching over is allowed.<br />
• Using an optional manual operation box enables the <strong>feed</strong>ing system to be controlled<br />
manually in the event of trouble without interrupting animal growth. During manual operation<br />
wheat cannot be mixed.<br />
28-02-11 / Modifications reserved PAGE 04-55-01
POULTRY<br />
<strong>F42</strong> FEED WEIGHER<br />
<strong>F42</strong> EasyBlend<br />
<strong>F42</strong>.2 EasyBlend<br />
Broilers Yes Yes<br />
Rearers and parent stock NO NO<br />
Number of <strong>house</strong>s 1 2<br />
Number of bunkers 1 2X1<br />
Number of valves NONE NONE<br />
'Weigher' 1 1<br />
Ingredients 5 5<br />
Stock silos 3 4<br />
Curves 10 10<br />
Blends (max. 3 ingredients) 10 10<br />
Feeding times 24 24<br />
Time clocks 1 2X1<br />
Light clocks 8 2X8<br />
Light schemes 1 1<br />
Light control and measurement 8 2X8<br />
Feed clocks<br />
linked to<br />
<strong>feed</strong>ing times<br />
linked to<br />
<strong>feed</strong>ing times<br />
Water clocks 1 2X1<br />
Concept<br />
Registration groups 32 2X32<br />
Registration mode Yes Yes<br />
Rationed <strong>feed</strong>ing mode Yes Yes<br />
Skip-a-day functionality NO NO<br />
• In the start situation the storage hoppers in the <strong>house</strong> are filled with <strong>feed</strong>.<br />
• As soon as the <strong>feed</strong> process starts, a new portion of <strong>feed</strong> is prepared in the batch <strong>weigher</strong>,<br />
in the right mixing ratio.<br />
• While the <strong>feed</strong> is transported to the hopper in the <strong>house</strong>, the <strong>feed</strong> types are well mixed.<br />
• The last hopper in the <strong>house</strong> at the end of the <strong>feed</strong>ing lines contains sensors, which control<br />
a correct supply of <strong>feed</strong>.<br />
28-02-11 / Modifications reserved PAGE 04-55-02
POULTRY<br />
<strong>F42</strong> FEED WEIGHER<br />
Screen<br />
examples<br />
Options A4230060 WU.70 Weighing unit 70 liter<br />
A4230095<br />
WU.70i Weighing unit 70 liter + LCC<br />
A4230064<br />
A4230091<br />
Weighing unit table 70 liter<br />
Weighing unit table 70 liter high<br />
A4230065<br />
Weighing unit dust hopper<br />
A3230001<br />
Weighing unit polyester<br />
A7130013<br />
Manual operation box FWBSK.3e<br />
A4240004<br />
Prox 230V with settable time delay<br />
A4240006<br />
Prox 24V with settable time delay<br />
A4240007<br />
Prox 24V without settable time delay<br />
A7018014.01 IRM.16 relay station to increase the number of relays<br />
A7019101.05 IDM.16 digital input station to increase the number of digital inputs<br />
A5261001<br />
Water meter 3m³/h ¾”+ pulse<br />
A5261002<br />
Water meter 5m³/h 1”+ pulse<br />
28-02-11 / Modifications reserved PAGE 04-55-03
POULTRY<br />
<strong>F42</strong> FEED WEIGHER<br />
Standard I/O<br />
IOB.4<br />
• 4 analog inputs<br />
• 4 relays, voltage free<br />
• 1 alarm relay<br />
• 4 0-10V voltage outputs<br />
• 4 digital inputs for the registration inputs<br />
Wiring<br />
FRM.8<br />
• 8 relays, voltage free<br />
<strong>F42</strong>.2<br />
DI.4<br />
• 4 digital inputs for the registration inputs<br />
Power<br />
3 x 2,5 mm 2 Alarm relay<br />
2 x 0,8 mm (0,5 mm 2 )<br />
2 x 0,8 mm (0,5 mm 2 )<br />
2 x 0,8 mm (0,5 mm 2 )<br />
2 x 0,8 mm (0,5 mm 2 )<br />
Analog input (4x)<br />
Digital input (4x)<br />
Analog output (4x)<br />
Relay output (12x)<br />
2 x 0,8 mm (0,5 mm 2 )<br />
I/O-net*<br />
24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />
WU.70i<br />
or<br />
I/O-net*<br />
24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />
ILM.c1<br />
(option)<br />
6 x 0,8 mm<br />
(0,5 mm 2 )<br />
shielded,<br />
max. 50mtr.<br />
Connection box weighbar<br />
I/O-net*<br />
24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />
FNet*<br />
**<br />
IRM.16 / IDM.16<br />
(option)<br />
Relay output (16x) /<br />
Digital input (16x)<br />
Network communication<br />
Technical specifications<br />
* Greenlink: 2 x 0,8 mm 2 twisted pair<br />
** Maximum 30 F-net modules in 1 network<br />
Power supply 45W<br />
Power supply<br />
Mains supply<br />
Mains frequency<br />
Maximum power consumption<br />
90Vac – 264Vac<br />
50/60Hz<br />
45VA<br />
28-02-11 / Modifications reserved PAGE 04-55-04
POULTRY<br />
<strong>F42</strong> FEED WEIGHER<br />
IOB.4<br />
Power available for sensors and peripheral equipment<br />
24Vdc (fused )<br />
12Vdc, short circuit resistant<br />
max. 500mA<br />
max. 70mA<br />
4 Analog inputs<br />
Type selection via Jumper<br />
resistance or voltage<br />
Resistance: Temperature range sensor type S.7 -50°C to +110°C<br />
- accuracy (-25C to +100C) < 0,5°C<br />
- accuracy (0C to +60C) < 0,2°C<br />
Position <strong>feed</strong>back measuring range<br />
0-20kΩ<br />
Voltage: Measuring range (input resistance 100kΩ) 0-10Vdc<br />
Accuracy<br />
+/- 15mVdc<br />
4 Digital inputs<br />
Open contact (high level)<br />
24Vdc<br />
Low level<br />