POULTRY<br />

<strong>F42</strong> FEED WEIGHER<br />

Contents<br />

<strong>F42</strong> EasyBlend <strong>feed</strong> <strong>weigher</strong>, 1 <strong>house</strong><br />

<strong>F42</strong>.2 EasyBlend <strong>feed</strong> <strong>weigher</strong>, 2 <strong>house</strong>s<br />

Application _________________________ 1<br />

Features __________________________ 1<br />

Concept ___________________________ 2<br />

Screen examples ___________________ 3<br />

Options ___________________________ 3<br />

Standard I/O _______________________ 4<br />

Wiring ____________________________ 4<br />

Technical specifications _____________ 4<br />

A7022119<br />

A7022120<br />

Application<br />

The <strong>F42</strong> activates the EasyBlend concept.<br />

EasyBlend uses a batch <strong>weigher</strong> positioned between the silo and the hoppers in the <strong>house</strong>.<br />

EasyBlend is specially for situations where 1 or 2 ingredients, usually wheat, are mixed with a<br />

core <strong>feed</strong>. This concept is not suitable for preparing <strong>feed</strong> yourself.<br />

The system consists of the <strong>F42</strong> control computer and a <strong>weigher</strong>. The entire process is accurately<br />

controlled, from preparing the <strong>feed</strong> in the batch <strong>weigher</strong>, filling the hoppers in the <strong>house</strong> right up<br />

to supplying the <strong>feed</strong>ing lines in the <strong>house</strong>.<br />

The <strong>F42</strong> controls 1 (<strong>F42</strong>) or 2 (<strong>F42</strong>.2) <strong>house</strong>s with maximum 4 silos and registers the consumption<br />

of 5 <strong>feed</strong> types. It is also possible to mix two <strong>feed</strong> types or cereals to reduce <strong>feed</strong> costs and<br />

to control the growth of your animals more accurately.<br />

Features • Accurate control of the <strong>feed</strong>ing process from silo to pan<br />

• Possibility to mix wheat<br />

• Unrestricted or rationed <strong>feed</strong>ing<br />

• Several <strong>feed</strong>ing cycles per 24 hours (8 maximum).<br />

• Stock control<br />

• Registration of water consumption<br />

• A <strong>feed</strong> curve enables the daily <strong>feed</strong> amount to be programmed (maximum 10 <strong>feed</strong> curves<br />

with 20 bending points).<br />

• Timer functions for water, light or <strong>feed</strong>. Water, <strong>feed</strong> and light are always geared to one<br />

another.<br />

• 8 extended light clocks, with ON/OFF control, dimmer function, including light measurement<br />

and control.<br />

• EasyBlend perfectly fits in existing situations.<br />

• When the silo is empty, EasyBlend automatically switches to another silo with the same<br />

<strong>feed</strong> type.<br />

• To prevent premature switching to another <strong>feed</strong> type with bridge forming, EasyBlend uses<br />

the day number to check if switching over is allowed.<br />

• Using an optional manual operation box enables the <strong>feed</strong>ing system to be controlled<br />

manually in the event of trouble without interrupting animal growth. During manual operation<br />

wheat cannot be mixed.<br />

28-02-11 / Modifications reserved PAGE 04-55-01


POULTRY<br />

<strong>F42</strong> FEED WEIGHER<br />

<strong>F42</strong> EasyBlend<br />

<strong>F42</strong>.2 EasyBlend<br />

Broilers Yes Yes<br />

Rearers and parent stock NO NO<br />

Number of <strong>house</strong>s 1 2<br />

Number of bunkers 1 2X1<br />

Number of valves NONE NONE<br />

'Weigher' 1 1<br />

Ingredients 5 5<br />

Stock silos 3 4<br />

Curves 10 10<br />

Blends (max. 3 ingredients) 10 10<br />

Feeding times 24 24<br />

Time clocks 1 2X1<br />

Light clocks 8 2X8<br />

Light schemes 1 1<br />

Light control and measurement 8 2X8<br />

Feed clocks<br />

linked to<br />

<strong>feed</strong>ing times<br />

linked to<br />

<strong>feed</strong>ing times<br />

Water clocks 1 2X1<br />

Concept<br />

Registration groups 32 2X32<br />

Registration mode Yes Yes<br />

Rationed <strong>feed</strong>ing mode Yes Yes<br />

Skip-a-day functionality NO NO<br />

• In the start situation the storage hoppers in the <strong>house</strong> are filled with <strong>feed</strong>.<br />

• As soon as the <strong>feed</strong> process starts, a new portion of <strong>feed</strong> is prepared in the batch <strong>weigher</strong>,<br />

in the right mixing ratio.<br />

• While the <strong>feed</strong> is transported to the hopper in the <strong>house</strong>, the <strong>feed</strong> types are well mixed.<br />

• The last hopper in the <strong>house</strong> at the end of the <strong>feed</strong>ing lines contains sensors, which control<br />

a correct supply of <strong>feed</strong>.<br />

28-02-11 / Modifications reserved PAGE 04-55-02


POULTRY<br />

<strong>F42</strong> FEED WEIGHER<br />

Screen<br />

examples<br />

Options A4230060 WU.70 Weighing unit 70 liter<br />

A4230095<br />

WU.70i Weighing unit 70 liter + LCC<br />

A4230064<br />

A4230091<br />

Weighing unit table 70 liter<br />

Weighing unit table 70 liter high<br />

A4230065<br />

Weighing unit dust hopper<br />

A3230001<br />

Weighing unit polyester<br />

A7130013<br />

Manual operation box FWBSK.3e<br />

A4240004<br />

Prox 230V with settable time delay<br />

A4240006<br />

Prox 24V with settable time delay<br />

A4240007<br />

Prox 24V without settable time delay<br />

A7018014.01 IRM.16 relay station to increase the number of relays<br />

A7019101.05 IDM.16 digital input station to increase the number of digital inputs<br />

A5261001<br />

Water meter 3m³/h ¾”+ pulse<br />

A5261002<br />

Water meter 5m³/h 1”+ pulse<br />

28-02-11 / Modifications reserved PAGE 04-55-03


POULTRY<br />

<strong>F42</strong> FEED WEIGHER<br />

Standard I/O<br />

IOB.4<br />

• 4 analog inputs<br />

• 4 relays, voltage free<br />

• 1 alarm relay<br />

• 4 0-10V voltage outputs<br />

• 4 digital inputs for the registration inputs<br />

Wiring<br />

FRM.8<br />

• 8 relays, voltage free<br />

<strong>F42</strong>.2<br />

DI.4<br />

• 4 digital inputs for the registration inputs<br />

Power<br />

3 x 2,5 mm 2 Alarm relay<br />

2 x 0,8 mm (0,5 mm 2 )<br />

2 x 0,8 mm (0,5 mm 2 )<br />

2 x 0,8 mm (0,5 mm 2 )<br />

2 x 0,8 mm (0,5 mm 2 )<br />

Analog input (4x)<br />

Digital input (4x)<br />

Analog output (4x)<br />

Relay output (12x)<br />

2 x 0,8 mm (0,5 mm 2 )<br />

I/O-net*<br />

24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />

WU.70i<br />

or<br />

I/O-net*<br />

24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />

ILM.c1<br />

(option)<br />

6 x 0,8 mm<br />

(0,5 mm 2 )<br />

shielded,<br />

max. 50mtr.<br />

Connection box weighbar<br />

I/O-net*<br />

24 Vdc, 2x0,8 mm (0,5 mm 2 )<br />

FNet*<br />

**<br />

IRM.16 / IDM.16<br />

(option)<br />

Relay output (16x) /<br />

Digital input (16x)<br />

Network communication<br />

Technical specifications<br />

* Greenlink: 2 x 0,8 mm 2 twisted pair<br />

** Maximum 30 F-net modules in 1 network<br />

Power supply 45W<br />

Power supply<br />

Mains supply<br />

Mains frequency<br />

Maximum power consumption<br />

90Vac – 264Vac<br />

50/60Hz<br />

45VA<br />

28-02-11 / Modifications reserved PAGE 04-55-04


POULTRY<br />

<strong>F42</strong> FEED WEIGHER<br />

IOB.4<br />

Power available for sensors and peripheral equipment<br />

24Vdc (fused )<br />

12Vdc, short circuit resistant<br />

max. 500mA<br />

max. 70mA<br />

4 Analog inputs<br />

Type selection via Jumper<br />

resistance or voltage<br />

Resistance: Temperature range sensor type S.7 -50°C to +110°C<br />

- accuracy (-25C to +100C) < 0,5°C<br />

- accuracy (0C to +60C) < 0,2°C<br />

Position <strong>feed</strong>back measuring range<br />

0-20kΩ<br />

Voltage: Measuring range (input resistance 100kΩ) 0-10Vdc<br />

Accuracy<br />

+/- 15mVdc<br />

4 Digital inputs<br />

Open contact (high level)<br />

24Vdc<br />

Low level<br />