BITEXTENE FLEX/MT SERIES<br />

Product description<br />

BITEXTENE/MT waterproofing membranes are produced by co-extruding a specially formulated elastomeric compound<br />

consisting of a complex dispersion of rubbers and copolymers in selected distilled bitumens with a non-woven continuous<br />

filament stabilized polyester fiber reinforcing mat located midway through the membrane’s thickness and acting in<br />

total synergy with it. The BITEXTENE/MT Series consists of two versions: BITEXTENE FLEX/MT3 and MT4, with thicknesses<br />

of 3 and 4 mm respectively.<br />

Both faces are coated with TEXTENE ® preformed textured polymer fiber film. BITEXTENE FLEX/MT Series membranes<br />

are supplied in strapped rolls, each accompanied by a Quality Control Certificate.<br />

They comply with CE marking requirements where applicable, and contain no asbestos, tar or other dangerous substances.<br />

Recommended uses<br />

BITEXTENE FLEX/MT Series membranes are ideal for all applications calling for excellent bonding to the substrate, as is<br />

needed when waterproofing below-grade walls, vehicular traffic-bearing surfaces, etc.<br />

Compared to ordinary finishes, the TEXTENE ® treatment is cleaner to work with and releases less dust, ensuring low environmental<br />

impact at the installation site. The two textured faces improve membrane torch application, making for faster<br />

installation and more effective adhesion to the substrate.<br />

Membrane suitability for applications where CE marking is required is detailed in the table below.<br />

For detailed documentation and guidance regarding product application, consult IMPER ITALIA S.p.A. Technical Services.<br />

PRODUCT USE (1)<br />

Single-ply<br />

Roofing Roofing Vapor Foundations<br />

(EN 13707) underlay control (EN 13969)<br />

(EN 13859-1) (EN 13970)<br />

Under heavy-duty<br />

Exposed<br />

Roof gardens<br />

pesante<br />

Multi-play<br />

Root<br />

Single-ply Multi-play<br />

Cap <strong>sheet</strong> Base ply resistant<br />

Multi-ply<br />

BITEXTENE FLEX/MT 3 • • •<br />

BITEXTENE FLEX/MT 4 • (2) • • • •<br />

(1) In compliance with applicable standards and AISPEC-MBP guidelines.<br />

(2) Overcoated with Elastomul series, Parwenol 4822 AL or ALLABIT 822 AL protective paints.<br />

Methods of application<br />

BITEXTENE FLEX/MT Series membranes are designed for easy torch application after priming, or are secured using<br />

mechanical means. They are also suitable for cold application using ADITHENE adhesive. Waterproofing performance<br />

will depend to a significant extent on application methods. Designed for versatility and ease of application, BITEXTENE<br />

FLEX/MT membranes are laid using standard tools: a propane torch, trowel and cutter. Special care must be taken at<br />

joins, which must be overlapped. Membrane must be laid to allow side laps of 8 to 10 cm and end laps of 12 to 15 cm.<br />

For detailed documentation and guidance in selecting the most appropriate procedures for any job, consult IMPER<br />

ITALIA S.p.A. Technical Services, who will be happy to provide assistance and advice in designing special waterproofing<br />

systems and helping you make the best use of these materials.


Properties<br />

EN<br />

standards<br />

(BITEXTENE FLEX/MT SERIES continued)<br />

SPECIFICATIONS (1)<br />

Unit of<br />

BITEXTENE FLEX/MT<br />

measure Tolerances(1) 3 4<br />

Roll dimensions 1848-1 m ≥ 10 × 1 (–1%)<br />

Thickness 1849-1 mm ±5 % 3 4<br />

Mass 1849-1 kg/m 2 ±10 % -<br />

Watertightness 1928-B kPa ≥ 60<br />

Cold flexibility 1109 °C ≤ –20<br />

Hot creep 1110 °C ≥ 110<br />

Tensile strength, L/T 12311-1 N/5cm ±20% 550/350<br />

Tensile elongation, L/T 12311-1 % ±15 40/45<br />

Dimensional stability, L/T 1107-1 % ≤ -<br />

Puncture resistance - Static indentation 12730 kg ≥ NPD (2) 20<br />

Puncture resistance - Dynamic indentation 12691-B mm ≥ NPD (2) 1000<br />

Tear resistance, L/T 12310-1 N ±30% 150/160<br />

Joint peel resistance 12316-1 N/5cm ±20 N NPD (2) 100<br />

Joint cut resistance (2) 12317-1 N/5cm ±20% NPD (2) 450/300 (3)<br />

Durability after aging:<br />

- Cold flexibility 1296-1109 °C +15°C -<br />

- Hot creep 1296-1110 °C –10°C +100<br />

- UV weathering exposure 1297 - - Test passes<br />

- Watertightness 1296-1928 kPa ≥ 60<br />

- Chemical resistance - - - NPD (2)<br />

- Tensile strength, L/T 12311-1 N/5cm ±20% NPD (2)<br />

- Tensile elongation, L/T 12311-1 % ±15 NPD (2)<br />

Water vapor permeability 1931 μ ≥ 20.000<br />

Root resistance LG Aispec - NPD (2)<br />

Fire resistance 13501-5 EC (4) - F Roof<br />

Fire reaction rating 13501-1 EC (4) - F<br />

(1) In compliance with applicable standards and AISPEC-MBP guidelines.<br />

(2) Not determined, because not relevant for application.<br />

(3) Or failure away from joints.<br />

(4) Euroclass.<br />

10/BFMT/I.2.<br />

10-10