Read data sheet - Imper
Read data sheet - Imper
Read data sheet - Imper
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
BITEXTENE FLEX/MT SERIES<br />
Product description<br />
BITEXTENE/MT waterproofing membranes are produced by co-extruding a specially formulated elastomeric compound<br />
consisting of a complex dispersion of rubbers and copolymers in selected distilled bitumens with a non-woven continuous<br />
filament stabilized polyester fiber reinforcing mat located midway through the membrane’s thickness and acting in<br />
total synergy with it. The BITEXTENE/MT Series consists of two versions: BITEXTENE FLEX/MT3 and MT4, with thicknesses<br />
of 3 and 4 mm respectively.<br />
Both faces are coated with TEXTENE ® preformed textured polymer fiber film. BITEXTENE FLEX/MT Series membranes<br />
are supplied in strapped rolls, each accompanied by a Quality Control Certificate.<br />
They comply with CE marking requirements where applicable, and contain no asbestos, tar or other dangerous substances.<br />
Recommended uses<br />
BITEXTENE FLEX/MT Series membranes are ideal for all applications calling for excellent bonding to the substrate, as is<br />
needed when waterproofing below-grade walls, vehicular traffic-bearing surfaces, etc.<br />
Compared to ordinary finishes, the TEXTENE ® treatment is cleaner to work with and releases less dust, ensuring low environmental<br />
impact at the installation site. The two textured faces improve membrane torch application, making for faster<br />
installation and more effective adhesion to the substrate.<br />
Membrane suitability for applications where CE marking is required is detailed in the table below.<br />
For detailed documentation and guidance regarding product application, consult IMPER ITALIA S.p.A. Technical Services.<br />
PRODUCT USE (1)<br />
Single-ply<br />
Roofing Roofing Vapor Foundations<br />
(EN 13707) underlay control (EN 13969)<br />
(EN 13859-1) (EN 13970)<br />
Under heavy-duty<br />
Exposed<br />
Roof gardens<br />
pesante<br />
Multi-play<br />
Root<br />
Single-ply Multi-play<br />
Cap <strong>sheet</strong> Base ply resistant<br />
Multi-ply<br />
BITEXTENE FLEX/MT 3 • • •<br />
BITEXTENE FLEX/MT 4 • (2) • • • •<br />
(1) In compliance with applicable standards and AISPEC-MBP guidelines.<br />
(2) Overcoated with Elastomul series, Parwenol 4822 AL or ALLABIT 822 AL protective paints.<br />
Methods of application<br />
BITEXTENE FLEX/MT Series membranes are designed for easy torch application after priming, or are secured using<br />
mechanical means. They are also suitable for cold application using ADITHENE adhesive. Waterproofing performance<br />
will depend to a significant extent on application methods. Designed for versatility and ease of application, BITEXTENE<br />
FLEX/MT membranes are laid using standard tools: a propane torch, trowel and cutter. Special care must be taken at<br />
joins, which must be overlapped. Membrane must be laid to allow side laps of 8 to 10 cm and end laps of 12 to 15 cm.<br />
For detailed documentation and guidance in selecting the most appropriate procedures for any job, consult IMPER<br />
ITALIA S.p.A. Technical Services, who will be happy to provide assistance and advice in designing special waterproofing<br />
systems and helping you make the best use of these materials.
Properties<br />
EN<br />
standards<br />
(BITEXTENE FLEX/MT SERIES continued)<br />
SPECIFICATIONS (1)<br />
Unit of<br />
BITEXTENE FLEX/MT<br />
measure Tolerances(1) 3 4<br />
Roll dimensions 1848-1 m ≥ 10 × 1 (–1%)<br />
Thickness 1849-1 mm ±5 % 3 4<br />
Mass 1849-1 kg/m 2 ±10 % -<br />
Watertightness 1928-B kPa ≥ 60<br />
Cold flexibility 1109 °C ≤ –20<br />
Hot creep 1110 °C ≥ 110<br />
Tensile strength, L/T 12311-1 N/5cm ±20% 550/350<br />
Tensile elongation, L/T 12311-1 % ±15 40/45<br />
Dimensional stability, L/T 1107-1 % ≤ -<br />
Puncture resistance - Static indentation 12730 kg ≥ NPD (2) 20<br />
Puncture resistance - Dynamic indentation 12691-B mm ≥ NPD (2) 1000<br />
Tear resistance, L/T 12310-1 N ±30% 150/160<br />
Joint peel resistance 12316-1 N/5cm ±20 N NPD (2) 100<br />
Joint cut resistance (2) 12317-1 N/5cm ±20% NPD (2) 450/300 (3)<br />
Durability after aging:<br />
- Cold flexibility 1296-1109 °C +15°C -<br />
- Hot creep 1296-1110 °C –10°C +100<br />
- UV weathering exposure 1297 - - Test passes<br />
- Watertightness 1296-1928 kPa ≥ 60<br />
- Chemical resistance - - - NPD (2)<br />
- Tensile strength, L/T 12311-1 N/5cm ±20% NPD (2)<br />
- Tensile elongation, L/T 12311-1 % ±15 NPD (2)<br />
Water vapor permeability 1931 μ ≥ 20.000<br />
Root resistance LG Aispec - NPD (2)<br />
Fire resistance 13501-5 EC (4) - F Roof<br />
Fire reaction rating 13501-1 EC (4) - F<br />
(1) In compliance with applicable standards and AISPEC-MBP guidelines.<br />
(2) Not determined, because not relevant for application.<br />
(3) Or failure away from joints.<br />
(4) Euroclass.<br />
10/BFMT/I.2.<br />
10-10