<strong>TEL12</strong>-<strong>90</strong><br />

<strong>TEL12</strong>-<strong>90</strong> – Specifications<br />

Cells<br />

Per Unit<br />

Voltage<br />

Per Unit Weight Electrolyte<br />

6 12.84 72.0 lbs.<br />

32.5 kg<br />

Absorbed H 2<br />

SO 4<br />

SG = 1.300<br />

Maximum<br />

Discharge Current<br />

Short Circuit<br />

Currrent<br />

800 Amps 3600 Amps<br />

@ 0.1 sec.<br />

Ohms Imped.<br />

60 Hz (Ω)<br />

0.0035 Ohms<br />

Capacity<br />

88 Ah @ 8 hour rate to 1.75 volts per cell @ 77°F (25°C)<br />

85.4 Ah @ 10 hour rate to 1.80 volts per cell @ 20°C (68°F)<br />

O perating Temperature Range D ischarge;<br />

- 40°F (-40°C) to +140°F (60°C),<br />

C harge;<br />

-4°F (-20°C) to +122°F (50°C)<br />

Nominal<br />

Range<br />

Operating Temperature<br />

+74°F (23°C) to +80°F (27°C)<br />

F loat Charging Voltage<br />

13.5 to 13.8 VDC/unit Average @ 77°F (25°C)<br />

Recommended<br />

Current Limit<br />

Maximum Charging<br />

C/5 amperes (16.2 amps @ 100% depth of discharge)<br />

M aximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results.<br />

Maximum voltage allowed = 4% P-P<br />

Maximum current allowed = 5.0 amperes RMS (C/20)<br />

Self Discharge<br />

Dynasty Telecom batteries may be stored for up to 6 months at 77°F (25°C) and<br />

then a freshening charge is required. For higher temperatures the time interval will<br />

be shorter.<br />

A ccessories<br />

Inter unit connectors, racks and cabinet systems are available.<br />

T erminal<br />

Threaded copper alloy insert terminal to accept 1/4-20 UNC bolt.<br />

T erminal Hardware Torque<br />

110 in.-lbs. (12.4 n-m) .<br />

Constant Current Discharge Ratings – Amperes @ 77°F (25°C)<br />

Note:<br />

End Point<br />

Volts/Cell 1.00<br />

Operating Time to End Point Voltage (in hours)<br />

2.00 3.00 4.00 5.00 6.00 7.00 8.00 10.00 12.00 20.00 24.00 72.00 100.00<br />

1.75 61.5 34.8 25.0 19.6 16.2 14.0 12.3 11.0 9.08 7.79 5.00 4.19 1.43<br />

1.80 60.1 34.0 24.2 19.0 15.8 13.6 11.9 10.7 8.80 7.58 4.89 4.10 1.42<br />

1.85 55.0 31.4 22.8 18.0 15.0 12.9 11.3 10.1 8.44 7.23 4.67 3.92 1.37<br />

1.<strong>90</strong> 47.0 28.9 21.0 16.8 14.0 12.0 10.6 9.50 7.<strong>90</strong> 6.73 4.34 3.65 1.26<br />

Batteries to be mounted with 0.5 in. spacing minimum and free air ventilation.<br />

1.04<br />

1.03<br />

0.99<br />

0.91