Hybrid - Ecotechnics
Hybrid - Ecotechnics
Hybrid - Ecotechnics
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
3<br />
All our services<br />
PATENT PENDING PATENT PENDING PATENTED PATENTED<br />
Saniflux <strong>Hybrid</strong> Diag Nitro Hermetic<br />
The first A/C system and<br />
passenger compartment<br />
air purification system fully<br />
integrated in a charging<br />
station. 2 services in a single<br />
station!<br />
<strong>Ecotechnics</strong>’ patented singlestation<br />
solution for charging<br />
standard, hybrid and electric<br />
vehicles, and vehicles with<br />
electric compressors.<br />
Integrated system for<br />
diagnosis of electromechanical<br />
problems on A/C<br />
systems, featuring printout<br />
of diagnosis and problem<br />
solutions.<br />
A/C system leak testing by<br />
charging with nitrogen from an<br />
external bottle (not included)<br />
and monitoring pressure drops,<br />
with leak alarm.<br />
Collapsible, hermetic<br />
cartridges offer full protection<br />
against ambient humidity for<br />
oil and dye, to guarantee full<br />
product efficiency.
4<br />
The first air purification system integrated<br />
in an A/C charging station
5<br />
Saniflux<br />
PATENT PENDING<br />
The Saniflux integrated<br />
system applies ultrasound<br />
technology (the same used<br />
in aerosols) to passenger<br />
compartment air purification<br />
and evaporator sanitising, to<br />
eliminate annoying odours<br />
and infuse a pleasant scent.<br />
With the certified Saniflux<br />
Liquid in the tank, select the<br />
service time from the station<br />
menu according to vehicle<br />
type (small, medium, large)<br />
and start treatment, which may<br />
be carried out simultaneously<br />
with A/C system charging in full<br />
automation.<br />
The passenger compartment<br />
air purification treatment<br />
uses a long hose, with a<br />
terminal drip-catcher, to<br />
permit directing the flow of<br />
nebulised product toward the<br />
evaporator, where bacteria,<br />
moulds, and other irritants<br />
and allergens may hide.<br />
The concentrated, continuous<br />
flow guarantees highlyeffective<br />
and long-lasting<br />
bactericide treatment.
6<br />
Suitable for all hybrid vehicles<br />
<strong>Hybrid</strong><br />
PATENT PENDING<br />
The new A/C systems on<br />
many latest-generation<br />
vehicles, such as hybrid or<br />
electric vehicles, are equipped<br />
with compressors operated<br />
by high-voltage electric<br />
motors containing a specific<br />
high-performance electrical<br />
insulating oil.<br />
Use of other oils may prove<br />
dangerous for the operator<br />
during system testing if high<br />
voltages are present.<br />
Preliminary flushing of the<br />
station and the service hoses<br />
is recommended before<br />
servicing a system of this<br />
type. Flushing eliminates the<br />
risk that residues of different<br />
(non-insulating) oils may be<br />
injected into the A/C system,<br />
jeopardising its safety and<br />
good operation.<br />
The patented <strong>Ecotechnics</strong><br />
system permits running this<br />
flushing cycle automatically,<br />
thanks to the specific lateral<br />
couplings, integrated with the<br />
station, for connecting the<br />
service hoses.
7<br />
Diag<br />
PATENTED<br />
The importance of patented<br />
diagnosis in recycling stations<br />
Diagnosis is an increasingly critical tool for anyone - climatecontrol<br />
specialists and not - wanting to expand their business<br />
to include A/C system repair. <strong>Ecotechnics</strong> offers the following<br />
patented solutions:<br />
1 Static Diagnosis 2<br />
The station uses the<br />
pressure and temperature<br />
values entered by the<br />
operator to perform<br />
automatic diagnosis.<br />
Dynamic Diagnosis<br />
With the pressure and<br />
temperature sensors A/C<br />
connected to the system, the<br />
station conducts analysis<br />
with no further need of<br />
operator intervention. The<br />
station prints a report for<br />
each type of diagnosis.<br />
ALL THE ADVANTAGES<br />
• Easy to use<br />
• Fast, accurate diagnosis<br />
• Printout of diagnosis and list<br />
of remedial actions<br />
• Reliability<br />
• Perfect integration with the<br />
stations
8<br />
Nitrogen leak testing<br />
Nitro<br />
The nitrogen leak testing system is an alternative to traditional<br />
leak detection methods (testing during the vacuum phase or<br />
dye injection). The advantage offered by nitrogen is that leak<br />
testing may be conducted under pressure with an inert gas. It<br />
is useful above all in those cases in which use of a dye is not<br />
permissible (for example, in automobile manufacturing).<br />
This system is fully integrated with the <strong>Ecotechnics</strong> recharging<br />
stations to eliminate the need for operator intervention during<br />
service. The system prints a leak test report at the end of<br />
testing.
9<br />
Hermetic<br />
PATENTED<br />
Hermetic oil and dye cartridges<br />
An A/C station equipped with<br />
hermetic cartridges offers<br />
the advantage of eliminating<br />
contact between the humidity<br />
naturally present in ambient<br />
air and the oil or dye, which<br />
are hygroscopic substances<br />
(that is, substances that easily<br />
absorb humidity).<br />
The collapsible, accordiontype<br />
hermetic cartridges<br />
guarantee the high quality<br />
of the product charged<br />
and protect the internal<br />
components of the station<br />
from possible damage from<br />
oils and/or dyes of uncertain<br />
provenance. Moreover,<br />
many vehicle manufacturers<br />
recommend use of hermetic<br />
cartridges in their authorised<br />
repair shops.
10<br />
Eck 800<br />
Fully automatic station<br />
for recovering, recycling,<br />
and recharging R134a refrigerant.<br />
Eck 890<br />
Type of refrigerant<br />
R134a<br />
Service procedure<br />
Fully automatic or manual<br />
Voltage<br />
50/60 Hz<br />
Scale resolution<br />
10 g<br />
Oil scale resolution 5 g<br />
Working temperature range 11/49°C<br />
Filter system<br />
1 filter for humidity<br />
Vacuum pump<br />
72 litre/min capacity, 0.1 mbar vacuum level<br />
Compressor<br />
Hermetically sealed, 12 cc, high pressure<br />
Recovery speed<br />
300 g/min in liquid phase<br />
Refrigerant bottle<br />
12 litres, refillable<br />
Hoses<br />
3 metres<br />
Overall size<br />
55 x 60 x 105 cm<br />
Weight<br />
80 kg<br />
Thermal printer<br />
Optional<br />
Pressure gauges Class 1<br />
Bottle pressure gauge Class 2.5<br />
Display<br />
Graphic<br />
Bottle temperature sensor Integrated<br />
Bottle heater<br />
Optional
11<br />
High precision<br />
<strong>Ecotechnics</strong> technology<br />
for maximum precision in<br />
recovery and recharging.<br />
Automatic Leak Testing<br />
The station checks for leaks<br />
during the vacuum phase. If<br />
leaks are found, it interrupts<br />
operation and gives an alarm.<br />
Refrigerant Management<br />
Each service is saved in<br />
station memory, offering<br />
the option of creating a<br />
customised archive of all<br />
refrigerant transactions.<br />
Database<br />
Automobile + truck database<br />
with user option to enter new<br />
vehicle models.<br />
Graphic Display<br />
Multi-language, new<br />
generation.<br />
STANDARD FEATURES<br />
OPTIONS<br />
Thermal Printer<br />
For a complete, detailed<br />
report.<br />
Automatic Bottle Heater<br />
For fast recharging at high or<br />
low ambient temperatures.<br />
Automatic Dye Injection<br />
With refillable cartridges and<br />
electronic scale.
12<br />
Eck 1000-up<br />
Fully automatic station for<br />
recovering, recycling, and<br />
recharging R134a refrigerant.<br />
SPECULARE<br />
rispetto alla foto<br />
originale<br />
Eck 1090-up<br />
Type of refrigerant R134a<br />
Service procedure Fully automatic or manual<br />
Voltage<br />
220-240V 50/60 Hz<br />
Scale resolution 10 g<br />
Oil scale resolution 5 g<br />
Working temperature range 11/49°C<br />
Filter system<br />
2 filters for humidity<br />
Vacuum pump<br />
100 litre/min capacity, 0.1 mbar vacuum level<br />
Compressor<br />
Hermetically sealed, 12 cc, high pressure<br />
Recovery speed<br />
300 g/min in liquid phase<br />
Refrigerant bottle 12 litres, refillable<br />
Hoses<br />
3 metres<br />
Overall size<br />
55 x 60 x 105 cm<br />
Weight<br />
80 kg<br />
Thermal printer<br />
Standard equipment<br />
Pressure gauges Class 1<br />
Bottle pressure gauge Class 2,5<br />
Display<br />
Graphic<br />
Bottle temperature sensor Integrated<br />
Bottle heater<br />
Standard equipment
13<br />
Refrigerant Management<br />
Each service is saved in<br />
station memory, offering<br />
the option of creating a<br />
customised archive of all<br />
refrigerant transactions.<br />
Thermal Printer for a<br />
complete, detailed report.<br />
STANDARD FEATURES<br />
OPTIONS<br />
Automatic Dye and Oil<br />
Injection with electronic<br />
scale and hermetic cartridges<br />
to protect the contents<br />
against contact with ambient<br />
humidity. (PATENTED)<br />
HFO UPgradable option<br />
of upgrading the charging<br />
station for use with the new<br />
HFO1234yf refrigerant, using<br />
a specific kit.<br />
Graphic Display<br />
multi-language, new<br />
generation.<br />
Diag<br />
Static diagnosis kit.<br />
Flushing kit<br />
For cleaning A/C systems by<br />
flushing with refrigerant.<br />
PATENTED<br />
PATENTED
14<br />
Eck 2500-up<br />
Fully automatic station for<br />
recovering, recycling, and<br />
recharging R134a refrigerant.<br />
Eck 2900-up<br />
Type of refrigerant R134a<br />
Service procedure Fully automatic or manual<br />
Voltage<br />
220-240V 50/60 Hz<br />
Scale resolution 10 g<br />
Oil scale resolution 5 g<br />
Working temperature range 11/49°C<br />
Filter system<br />
2 filters for humidity<br />
Vacuum pump<br />
100 litre/min capacity, 0.1 mbar vacuum level<br />
Compressor<br />
Hermetically sealed, 12 cc, high pressure<br />
Recovery speed<br />
300 g/min in liquid phase<br />
Refrigerant bottle 22 litres, refillable<br />
Hoses<br />
3 metres<br />
Overall size<br />
55 x 60 x 105 cm<br />
Weight<br />
80 kg<br />
Thermal printer<br />
Standard equipment<br />
Pressure gauges Class 1<br />
Display<br />
Graphic<br />
Bottle temperature sensor Integrated<br />
Bottle heater<br />
Standard equipment
15<br />
High precision<br />
<strong>Ecotechnics</strong> technology<br />
for maximum precision in<br />
recovery and recharging.<br />
Automatic Taps on high and<br />
low pressure lines for simpler,<br />
more practical use.<br />
STANDARD FEATURES<br />
OPTIONS<br />
Automatic Discharge of<br />
non-condensable gases via<br />
solenoid valves, with bottle<br />
temperature and pressure<br />
sensors. (PATENT PENDING)<br />
HFO UPgradable option<br />
of upgrading the charging<br />
station for use with the new<br />
HFO1234yf refrigerant, using<br />
a specific kit.<br />
Automatic Dye and Oil<br />
Injection with electronic<br />
scale and hermetic cartridges<br />
to protect the contents<br />
against contact with ambient<br />
humidity. (PATENTED)<br />
Saniflux<br />
Integrated passenger<br />
compartment air purification<br />
system.<br />
Diag<br />
Static diagnosis module.<br />
Dynamic diagnosis module.<br />
Nitro<br />
Automatic leak testing with<br />
nitrogen.<br />
<strong>Hybrid</strong><br />
Flushing of station and<br />
service hoses for use with<br />
vehicles equipped with electric<br />
compressors.<br />
Flushing kit<br />
For cleaning A/C systems by<br />
flushing with refrigerant.<br />
PATENT PENDING<br />
PATENTED<br />
PATENT PENDING<br />
PATENTED
16<br />
➜ Fast changeover from one<br />
gas to another<br />
➜ Protection against crosscontamination<br />
thanks to<br />
separate circuits for the 2<br />
gases<br />
➜ User savings<br />
➜ Compact design, 2-in-1<br />
station<br />
➜ 4 pressure gauges<br />
➜ 7” colour touch screen<br />
display<br />
➜ Automatic discharge of<br />
non-condensable gases<br />
➜ Automatic service taps<br />
➜ 2 pairs of service hoses<br />
➜ 4 separate lines for oil and<br />
dye<br />
➜ 2 compressors<br />
➜ Simple filter replacement<br />
➜ High-capacity fan / air<br />
exhaust<br />
Eck twin<br />
PATENT PENDING<br />
Fully automatic Dual-Gas station<br />
for recovering, recycling, and<br />
recharging R134a and HFO1234yf<br />
refrigerants.<br />
Type of refrigerant R134a and HFO1234yf<br />
Service procedure Fully automatic or manual<br />
Voltage<br />
220-240V - 50 Hz<br />
Scale resolution 10 g<br />
Oil scale resolution 5 g<br />
Working temperature range 11/49°C<br />
Filter system<br />
2 filters for humidity<br />
Vacuum pump<br />
100 litre/min capacity, 0.1 mbar vacuum level<br />
Compressor<br />
Hermetically sealed, 2x12 cc, high pressure<br />
Recovery speed<br />
300 g/min in liquid phase<br />
Refrigerant bottle 2x12 litres, refillable<br />
Hoses<br />
2 pairs, each 3 metres<br />
Overall size<br />
67 x 62 x 107 cm<br />
Weight<br />
110 kg<br />
Thermal printer<br />
Standard equipment<br />
Pressure gauges Class 1<br />
Display<br />
Colour graphic, touch screen<br />
Bottle temperature sensor Integrated<br />
Bottle heater<br />
Automatic
17<br />
Large 7” Colour Display with<br />
touch-screen icon messaging<br />
for easy use.<br />
Automatic Discharge of<br />
non-condensable gases via<br />
solenoid valves, with bottle<br />
temperature and pressure<br />
sensors. (PATENT PENDING)<br />
Automatic Leak Testing<br />
The station checks for leaks<br />
during the vacuum phase. If<br />
leaks are found, it interrupts<br />
operation and gives an alarm.<br />
Automatic Dye and Oil<br />
Injection with electronic<br />
scale and hermetic cartridges<br />
to protect the contents<br />
against contact with ambient<br />
humidity. (PATENTED)<br />
Automatic Taps on high and<br />
low pressure lines for simpler,<br />
more practical use.<br />
STANDARD FEATURES<br />
OPTIONS<br />
<strong>Hybrid</strong><br />
Flushing of station and<br />
service hoses for use with<br />
vehicles equipped with electric<br />
compressors.<br />
Flushing kit<br />
For cleaning A/C systems by<br />
flushing with refrigerant.<br />
PATENT PENDING<br />
PATENTED
18<br />
Eck 2500-hfo<br />
Fully automatic station for recovering,<br />
recycling, and recharging HFO1234yf<br />
refrigerant.<br />
Eck 2900-hfo<br />
Type of refrigerant HFO1234yf<br />
Service procedure Fully automatic or manual<br />
Voltage<br />
220-240V - 50 Hz<br />
Scale resolution 10 g<br />
Oil scale resolution 5 g<br />
Working temperature range 11/49°C<br />
Filter system<br />
2 filters for humidity<br />
Vacuum pump<br />
100 litre/min capacity, 0.1 mbar vacuum level<br />
Compressor<br />
Hermetically sealed, 12 cc, high pressure<br />
Recovery speed<br />
300 g/min in liquid phase<br />
Refrigerant bottle 12 litres, refillable<br />
Hoses<br />
3 metres<br />
Overall size<br />
55 x 60 x 105 cm<br />
Weight<br />
80 kg<br />
Thermal printer<br />
Standard equipment<br />
Pressure gauges Class 1<br />
Display<br />
Graphic<br />
Bottle temperature sensor Integrated<br />
Bottle heater<br />
Automatic
19<br />
High precision<br />
<strong>Ecotechnics</strong> technology<br />
for maximum precision in<br />
recovery and recharging.<br />
Automatic Taps on high and<br />
low pressure lines for simpler<br />
more practical use.<br />
STANDARD FEATURES<br />
OPTIONS<br />
Automatic Discharge of<br />
non-condensable gases via<br />
solenoid valves, with bottle<br />
temperature and pressure<br />
sensors. (PATENT PENDING)<br />
Automatic Leak Testing<br />
The station checks for leaks<br />
during the vacuum phase. If<br />
leaks are found, it interrupts<br />
operation and gives an alarm.<br />
Automatic Dye and Oil<br />
Injection with electronic<br />
scale and hermetic cartridges<br />
to protect the contents<br />
against contact with ambient<br />
humidity. (PATENT PENDING)<br />
Saniflux<br />
Integrated passenger<br />
compartment air purification<br />
system.<br />
Nitro<br />
Automatic leak testing with<br />
nitrogen.<br />
<strong>Hybrid</strong><br />
Flushing of station and<br />
service hoses for use with<br />
vehicles equipped with electric<br />
compressors.<br />
Flushing kit<br />
For cleaning A/C systems by<br />
flushing with refrigerant.<br />
PATENT PENDING PATENT PENDING PATENTED
20<br />
Fully automatic station for recovering, recycling,<br />
and recharging R134a refrigerant, for use with<br />
buses and industrial vehicles.<br />
STANDARD FEATURES<br />
Automatic Leak Testing<br />
The station checks for leaks<br />
during the vacuum phase. If<br />
leaks are found, it interrupts<br />
operation and gives an alarm.<br />
Automatic Discharge<br />
(PATENT PENDING)<br />
of non-condensable gases via<br />
solenoid valves, with bottle<br />
temperature and pressure<br />
sensors.<br />
Gear Pump<br />
for refrigerant charging.<br />
Eck bus<br />
Features identical to<br />
ECK BUS-PRO but:<br />
➜ without gear pump<br />
➜ with automatic bottle<br />
heater<br />
OPTIONS<br />
Type of refrigerant R134a<br />
Service procedure Fully automatic or manual<br />
Voltage<br />
220-240V - 50/60 Hz<br />
Scale resolution 10 g<br />
Oil scale resolution 5 g<br />
Working temperature range 11/49°C<br />
Filter system<br />
2 filters for humidity<br />
Vacuum pump<br />
170 litre/min capacity, 0.1 mbar vacuum level<br />
Compressor<br />
Hermetically sealed, 21 cc, high pressure<br />
Gear pump<br />
1 kg/min capacity<br />
Refrigerant bottle 40 litres, refillable<br />
Hoses<br />
6 metres<br />
Overall size<br />
80 x 120 x 115 cm<br />
Weight<br />
140 kg<br />
Thermal printer<br />
Standard equipment<br />
Display<br />
LCD<br />
Pressure gauges Class 1<br />
Flushing kit<br />
For cleaning A/C systems by<br />
flushing with refrigerant.<br />
PATENTED<br />
Eck bus-pro
Leak Detection Products & Consumables<br />
21<br />
AEK203 - Cobra kit HD<br />
Leak detector kit for A/C circuits<br />
including: goggles,<br />
UV lamp, hermetic<br />
dye cartridge<br />
(55 ml), injector<br />
AEK126-3-6 - Box of 6 hermetic<br />
cartridges of dye (125 ml) for R134a<br />
PAG46<br />
AEK265-6<br />
Box of 6 hermetic cartridges<br />
of oil (270 ml) for HFO1234yf<br />
AEK203-H - COBRA KIT HD HYBRID<br />
Identical to the AEK203 but with dye<br />
cartridge for hybrid vehicles<br />
AEK270-6 - Box of 6 hermetic cartridges<br />
of dye (125 ml) for HFO1234yf<br />
AEK222-1 - SANIFLUX LIQUID<br />
1000-ml bottle<br />
AEK203-C-5 - Box of 5 hermetic cartridges<br />
of dye (55 ml)<br />
AEK203-H-C-5 - Box of 5 hermetic cartridges<br />
of dye (55 ml) for hybrid vehicles<br />
AEK133-1<br />
Box of 12 – 7.4-ml cartridges<br />
AEK107-3 - Electronic LEAK DETECTOR:<br />
one instrument for identifying all halogen<br />
gases, including CFC, HCFC, HFC.<br />
AEK145-4 - COBRA CARTRIDGE KIT<br />
A/C circuit leak detector kit:<br />
UV lamp, goggles,<br />
6 cartridges (7.4 ml each) of dye,<br />
injector, 120-ml bottle of dye cleaner<br />
AEK204<br />
Oil kit for hybrid vehicles: hybrid-vehicle<br />
oil cartridge (55 ml), injector<br />
AEK107-6 - Electronic leak detector for<br />
combustible gases<br />
(50-1000 ppm) ideal for nitrogen +<br />
hydrogen mix<br />
AEK145<br />
Cobra lamp + goggles<br />
AEK204-H-5<br />
Box of 5 hermetic cartridges of<br />
oil for hybrid vehicles (55 ml)<br />
AEK147-1<br />
Rechargeable UV lamp: 12V, 50W<br />
AEK146 - DYE INJECTOR GUN,<br />
including dye (bottle for 64 applications),<br />
hose and coupling for R134a,<br />
high/low pressure adapter, air discharge<br />
coupling<br />
AEK125-1-6<br />
Box of 6 cartridges of A/C<br />
POE oil (237 ml)<br />
AEK160<br />
Air Fresh Spray deodorant spray<br />
AEK126-4<br />
350-ml bottle of universal dye<br />
PAG46<br />
PAG100<br />
PAG150<br />
AEK250 - 6<br />
AEK255 - 6<br />
AEK260 - 6<br />
Box of 6 hermetic<br />
cartridges of oil (270 ml)<br />
for R134a<br />
AEK161 - DYE CLEANER<br />
Liquid detergent for removing dye<br />
(474 ml)
22<br />
A/C Accessories<br />
XK184.000000 - EASYREC<br />
Refrigerant recovery unit<br />
- For use with all refrigerants<br />
- Compressor type: oilless<br />
- Air cooled<br />
- For use with gas and liquid refrigerant<br />
- Recovery rate (vapour): 17 kg/h<br />
- Recovery rate (liquid): 50 kg/h<br />
- Recovery rate (push-pull): 240 kg/h<br />
XK184.000039<br />
Easyrec plus<br />
Identical to EASYREC with carry case<br />
for R12/R134a hoses and couplings<br />
AEK302 - Electronic scale<br />
- LCD display<br />
- Max capacity: 100 kg<br />
- Resolution: 10 g<br />
- Charging accuracy: ± 10 g<br />
- Working temperature: -10°C / +50°C<br />
AEK515 - AEK525 - AEK535<br />
Set of flexible hoses<br />
90 cm<br />
150 cm<br />
180 cm<br />
CNT4010<br />
40 - litre bottle for R134a, R22, R404a,<br />
R507, R407C<br />
AEK214<br />
Rubber hose cutter<br />
AEK102-N7-R5<br />
Set of bypass adapters for AEK 102-N12<br />
flushing kit<br />
AEK102-N7-R6<br />
Pair of universal bus adapter disks for<br />
AEK 102-N12 flushing kit<br />
AEK102-N7-R3<br />
Set of 5 filters for AEK 102-N12<br />
flushing kit<br />
AEK215<br />
Valve-extractor screwdriver<br />
AEK120-E<br />
Digital thermometer<br />
AEK211<br />
Special quick-connect coupling<br />
AEK303<br />
Digital vacuum meter:<br />
0-12000 micron range<br />
AEK221<br />
Laser thermometer<br />
KITDB003.13<br />
2013 Data Base upgrade<br />
AEK118<br />
Compressor vane comb<br />
AEK220<br />
Digital thermometer with probe<br />
SCH8182<br />
USB-RS232 adapter for downloading<br />
station data to a USB memory key<br />
TUB1149 - Low-pressure service hose,<br />
6 m<br />
AEK116<br />
Reducer fitting for bottle<br />
AEK109A<br />
High-pressure terminal valve<br />
TUB1148 - High-pressure service hose,<br />
6 m<br />
+<br />
AEK116-1<br />
ACME hose reducer fitting for bottle<br />
AEK109B<br />
Low-pressure terminal valve
Functions Table<br />
23<br />
R134a<br />
HFO1234yf<br />
R134a<br />
ECK 890<br />
ECK 800<br />
ECK 1090-UP<br />
ECK 1000-UP<br />
ECK 2900-UP<br />
ECK 2500-UP<br />
ECK TWIN<br />
ECK 2900-HFO<br />
ECK 2500-HFO ECK BUS-PRO ECK BUS<br />
HIGH PRECISION<br />
● – ● ● ● – –<br />
HFO UPGRADABLE<br />
– ● ● – – – –<br />
Automatic<br />
leak check<br />
REFRIGERANT<br />
MANAGEMENT<br />
● – ● ● ● ● ●<br />
● ● ● ● ● ● ●<br />
DATA BASE<br />
● ● ● ● ● ● ●<br />
Graphic display<br />
● ● ● – ● LCD LCD<br />
TOUCH SCREEN<br />
DISPLAY<br />
collapsible<br />
cartridges<br />
REFILLABLE<br />
CONTAINERS<br />
– – – ● – – –<br />
– ● ● ● ● ● ●<br />
● – – – – – –<br />
AUTOMATIC TAPS<br />
AUTOMATIC Discharge of<br />
non-condensable gases<br />
– – ● ● ● – –<br />
– – ● ● ● ● ●<br />
105 cm<br />
gear pump<br />
– – – – – ● –<br />
55 cm<br />
60 cm<br />
Flushing software<br />
– ● ● ● ● ● ●<br />
USB PORT<br />
● ● ● ● ● ● ●<br />
SANIFLUX<br />
– – ❍ – ❍ – –<br />
HYBRID<br />
– – ❍ ❍ ❍ – –<br />
DIAG (STATIC)<br />
– ❍ ❍ – – – –<br />
DIAG (DINAMIC)<br />
– – ❍ – – – –<br />
NITRO<br />
– – ❍ – ❍ – –<br />
Printer<br />
❍ ● ● ● ● ● ●<br />
bottle heather<br />
❍ ● ● ● ● – ●<br />
122 cm<br />
AUTOMATIC DYE<br />
❍ ● ● ● ● ● ●<br />
FLUSHING KIT<br />
– ❍ ❍ ❍ ❍ ❍ ❍<br />
KIT UP<br />
– ❍ ❍ – – – –<br />
69 cm<br />
70 cm<br />
● STANDARD EQUIPMENT – Not Available ❍ Optional<br />
Information regarding dimensions, data, models, and colors is not binding. <strong>Ecotechnics</strong> reserves the right to make<br />
any modifications deemed necessary. The products are not covered by any other express or implicit warranties.<br />
90 Kg
STUDIO Mirannalti<br />
<strong>Ecotechnics</strong> S.p.A<br />
Via L. Longo, 21/23<br />
50019 Sesto F.no (FI)<br />
Tel. +39 055 4207372<br />
Fax +39 055 4217972<br />
www.ecotechnics.com<br />
email: ecotechnics@ecotechnics.com