1. Hiawatha type 200H 6 inches by 16 inch unless otherwise indicated.<br />

2. Where width of door stile prevents use of 6 inch wide plate, provide push plate one inch<br />

less than width of stile but not less than 4 inches wide.<br />

C. Push Bars:<br />

1. Hiawatha type 1081LBP, unless otherwise indicated.<br />

D. Pulls:<br />

1. Hiawatha Series 658A, unless otherwise indicated.<br />

2. Where required, mount back to back with push bars.<br />

E. Kick Plates and Armor Plates: Minimum of 0.050 inch thick, beveled 4 edges.<br />

1. At single doors provide width 1-1/2 inch less than door width on stop side and one inch<br />

less than door width on face side.<br />

2. At pairs of doors provide width one inch less than door width on both sides.<br />

3. Height of 10 inches, unless otherwise indicated.<br />

F. Edge Guards: Minimum .050" thick, stainless steel,<br />

1. Hiawatha type DE-2AJ x 42 inches high as noted in Hardware Groups.<br />

2.20 COORDINATORS<br />

A. Acceptable Manufacturers:<br />

Trimco<br />

3094 Series<br />

B. Provide 3094 Series coordinator for labeled pairs of doors equipped with automatic flush bolts<br />

and those with vertical rod/mortise lock fire exit device combinations with astragals.<br />

C. Provide filler bars for total opening width, closer mounting brackets, carry bars, and special<br />

preparation for top latches where applicable.<br />

2.21 DOOR CLOSERS<br />

A. Acceptable Manufacturers and Types of Exposed Closers:<br />

<strong>Sargent</strong> Norton Yale<br />

351/351-P10 7500/PR7500 4400/PR4400<br />

B. Provide non-sized closers, adjustable to meet maximum opening force requirements of ADA.<br />

C. Provide drop plates, brackets, or adapters for arms as required to suit details.<br />

D. Mount closers on room side of corridor doors, inside of exterior doors, and stair side of stairway<br />

doors.<br />

E. Provide back-check for closers.<br />

F. Provide hold-open arms where indicated.<br />

G. Provide closers for doors as noted in Hardware Groups and, in addition, provide closers for<br />

labeled doors whether or not specifically noted in group.<br />

H. Provide closers meeting the requirements of UBC 7-2 and UL 10C positive pressure tests.<br />

2.22 CLOSER/HOLDERS<br />

A. Acceptable Manufacturers Types of Exposed Closer/Holders:<br />

<strong>Sargent</strong> Norton Yale<br />

<strong>Sargent</strong><br />

Hardware<br />

09/08/03 <strong>08710</strong> - 9