IBERITAL DE RECAMBIOS, S.A.<br />
220V-240V SINGLE PHASE.<br />
The machine can be connected in single phase, in this case the black wire should be joined together<br />
with the red wire and then connected to phase. The white wire must be connected to other phase.<br />
Green wire to ground.<br />
Black Red White Green<br />
--///<br />
Phase (R)<br />
Phase (S)<br />
380V THREEE PHASE WITH NEUTRAL (TWO <strong>AND</strong> THREE GROUPS MACHINES)<br />
The machine can be connected in three phases 380V with neutral. In this case the black wire and the<br />
Red wire must be connected to one of the three phases, and the White wire to the neutral wire. The<br />
green conductor/wire must be connected to ground.<br />
Black Red White Green<br />
--///<br />
R<br />
S<br />
T<br />
N<br />
Página 13 de 17<br />
<strong>MANUAL</strong> IBERITAL JUNIOR INGLES<br />
11/05/2007