TYPE EXAMINATION CERTIFICATE - Mettler Toledo
TYPE EXAMINATION CERTIFICATE - Mettler Toledo
TYPE EXAMINATION CERTIFICATE - Mettler Toledo
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
[1] <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICATE</strong><br />
[2] Equipment or Protective System intended for use<br />
in Potentially Explosive Atmospheres<br />
Directive 94/9/EC<br />
[3] Type Examination Certificate Number: DEMKO 07 ATEX 0520819X<br />
[4] Equipment: IND 780 Panel and IND 780 Harsh<br />
[5] Manufacturer: <strong>Mettler</strong>-<strong>Toledo</strong> Inc.<br />
[6] Address: 1900 Polaris Parkway, Columbus, OH 43240, USA<br />
[7] This equipment and any acceptable variation thereto are specified in the schedule to this certificate and the documents therein referred to.<br />
[8] UL International Demko A/S certifies that this equipment has been found to comply with the Essential Health and Safety Requirements that<br />
relate to the design of Category 3 equipment, which is intended for use in potentially explosive atmospheres. These Essential Health and<br />
Safety Requirements are given in Annex II to the European Union Directive 94/9/EC of 23 March 1994.<br />
The examination and test results are recorded in confidential report no. 10NK02765<br />
[9] Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the schedule of this certificate, has been<br />
assessed by reference to Standards:<br />
EN 60079-0:2006 EN 60079-0: 2009<br />
EN 60079-15:2005 EN 60079-31:2009<br />
[10] If the sign "X" is placed after the certificate number, it indicates that the equipment or protective system is subject to special conditions for safe<br />
use specified in the schedule to this certificate.<br />
[11] This Type examination certificate relates only to the design of the specified equipment, and not to specific items of equipment subsequently<br />
manufactured.<br />
[12] The marking of the equipment or protective system shall include the following:<br />
e II 3 G Ex nA nL [nL] IIB T4 e II 3 D Ex tc IIIC T85 C Dc IP69K<br />
e II 3 G Ex nA nL [nL] IIB T4 e II 3 D Ex tc IIIC T85 C Dc IP65<br />
Certification Manager<br />
Jan-Erik Storgaard<br />
Certification Body<br />
This certificate may only be reproduced in its entirety and without any change,<br />
schedule included<br />
Date of issue: 2008-02-14<br />
Re-issued: 2011-03-18<br />
UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730<br />
Herlev, Denmark, Tel. +45 44 85 65 65, info.dk@dk.ul.com<br />
www.ul-europe.com<br />
00-IC-F0060 – Issue 4.1 Page 1 of 5
[13] Schedule<br />
[14] <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICATE</strong> No.<br />
DEMKO 07 ATEX 0520819X<br />
Report: 10NK02765<br />
[15] Description of Equipment:<br />
These devices are Industrial Weighting Terminals intended to measure and send data. There is a stand-alone version and a panel<br />
mounted version. IND 780 Panel is the panel mounted version. IND 780 Harsh is the stand-alone version.<br />
Nomenclature:<br />
I<br />
IND 780<br />
II<br />
HARSH<br />
I<br />
II<br />
Basic Model Designation<br />
Enclosure<br />
Harsh – Fully enclosed<br />
Panel – Open type<br />
Protection method per Model:<br />
Model IND780 Harsh: Ex nA nL [nL] IIB T4 Ex tc IIIC T85 C Dc IP69K<br />
Model IND780 Panel: Ex nA nL [nL] IIB T4 Ex tc IIIC T85 C Dc IP65<br />
The relation between ambient temperature and the assigned temperature class is as follows:<br />
Ambient temperature range<br />
Temperature class<br />
-10 C to +40 C (for II 3 G) T4<br />
-10 0 C to +40 0 C (for II 3 D) T85C<br />
Electrical data<br />
100-240VAC, 50/60 Hz 400 mA<br />
For IDNET Output connection:<br />
Power Supply 16 Vdc max<br />
Current Loop 17 Vdc max., 26 mA max<br />
NonIncendive Field Parameters: for load cells installed per the manufacturer’s installation instructions (Drawing No. 64069877).<br />
1. Analog load cell board Connection J1<br />
Uo= 10V<br />
Io = 313 mA<br />
Po = 3.13 W<br />
Lo = 1.20 mH<br />
Co = 100 uF<br />
2. Flowmeter board connection J3,<br />
Pins 1 (CH1 Hi Input), 2 (CH1 Low Input), 3 (CH1 Frame GND), 8 (Ch2 Hi Input), 9 (CH2 Low Input, 10 (CH2 Frame GND)<br />
Ui= 26.8V<br />
Ii = 200 mA<br />
Li = 30 uH<br />
Ci = 0 uF<br />
3. PDX Board Connection J3<br />
Pins 3 (CAN_H) and 5 (CAN_L)<br />
CANbus Listening:<br />
CANbus Talking:<br />
Ui= 26.8V Uo= 5.277V<br />
Ii = 4 mA<br />
Io= 200 mA<br />
Li = 0 uH<br />
Lo= 2.0 mH<br />
Ci = 0.602 nF<br />
Co= 1000 uF<br />
Pins 6 (+12V PWR) and 7 (GND)<br />
Uo= 12.6V<br />
Io = 1181 mA<br />
Lo = 229 uH<br />
Co = 59.4 uF<br />
00-IC-F0060 – Issue 4.1 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 5
[13] Schedule<br />
[14] <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICATE</strong> No.<br />
DEMKO 07 ATEX 0520819X<br />
Report: 10NK02765<br />
Installation instructions<br />
Model IND 780 panel shall be mounted in an enclosure with a minimum ingress protection rating of at least IP65 as defined in EN60529<br />
and the combination of the Model 780 panel and IP65 enclosure must be mounted in a location providing adequate protection against the<br />
entry of solid foreign objects or water capable of impairing safety.<br />
Both versions of the IND780 terminal shall be used only in environments where UV light cannot influence the non-metallic parts.<br />
All cable entry devices and blanking elements shall be ATEX certified and suitable for at least IP65 and correctly installed.<br />
Routine tests<br />
No routine testing is required.<br />
[16] Descriptive Documents<br />
Project Report No.:<br />
10NK02765 (Hazardous Location Testing)<br />
Drawings:<br />
Description: Drawing No.: Rev. Level: Date:<br />
IND780 Installation Instructions 64063214 02 2011-02<br />
IND780 Harsh Final Assembly 174866R 1 2011-03<br />
IND780 Panel Final Assembly 174867R 1 2011-03<br />
Label Drawings, Hazloc 173858R 12A 2010-12<br />
Label Drawings, standard 174966R 2a 2011-01<br />
Label, warning marking 64085494 - 2011-03<br />
Label, warning marking 15544000A - 1998-07<br />
Label, battery marking 64085511 - 2011-03<br />
Keypad Overlay 22009012 4 2007-09<br />
Control Diagram 64069877 - 2011-03<br />
Base board (Main board) - Schematics ES-22009024 6 2006-12-01<br />
Base board (Main board) – bill of materials 22009023 4 2008-06<br />
Base board (Main board) – component layout ME-22009023 7 - 2008-04-15<br />
Base board (Main board) – PCB layout ME-22009025 8 - 2008-04-15<br />
Base board (Main board alternate) - Schematics ES-22009024 J - 2010-11-08<br />
Base board (Main board alternate) – Bill of materials SL-64084167 A - 2010-11-14<br />
Base board (Main board alternate) – component layout ME-64084167 A - 2010-11-08<br />
Base board (Main board alternate) – PCB trace ME-22009025 K - 2010-11-08<br />
Color HMI - schematics A172067R 0 2005-09<br />
Color HMI – bill of materials 22009072 3 2009-04<br />
Color HMI – PCB layout A17206600A 1 2006-05<br />
Color HMI (alternate) - schematics 64083689 A 2010-11<br />
Color HMI (alternate) – Bill of Materials 64083260 B 2 2011-02<br />
Color HMI (alternate)– PCB Trace 64083259 A 2010-11<br />
Monochrome HMI - schematics ES-22009027 5 - 2005.09.14<br />
Monochrome HMI – bill of materials 22009026 5 2009-05<br />
Monochrome HMI – PCB layout 22009028 7 2005-03-09<br />
ALC option board - schematics 174608R - 2007-08<br />
ALC option board – bill of materials 64062179 5 2010-05<br />
ALC option board - PCB layout 17460900A - 2007-08<br />
IDNET option board - schematics ES-22009905 5 - 2007-07-20<br />
IDNET option board - bill of materials 22009904 A8 2010-05<br />
00-IC-F0060 – Issue 4.1 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 3 of 5
[13] Schedule<br />
[14] <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICATE</strong> No.<br />
DEMKO 07 ATEX 0520819X<br />
Report: 10NK02765<br />
Description: Drawing No.: Rev. Level: Date:<br />
IDNET option board - PCB layout 22009906 8 2005-09-10<br />
Devicenet option board - schematics 169067AR - 2005-06<br />
Devicenet option board - bill of materials 168988BA B 2007-07<br />
Devicenet option board - PCB layout 169067F - 2005-06<br />
ABRIO option board - schematics 169069CR C 2005-06-25<br />
ABRIO option board - bill of materials 168990DA D 2005-07-05<br />
ABRIO option board - PCB layout 169069E - 2005-02-04<br />
Serial option board - schematics ES-22009902 5 - 2007-07-20<br />
Serial option board - PCB layout BE-22009903 6 - 2005-08-10<br />
Serial option board – component layout ME-22009901 4 - 2005-08-13<br />
Serial option board – bill of materials 22009901 7 2009-02<br />
Powercell option board - schematics 170389R 1 2010-06<br />
Powercell option board - PCB layout 64070350 0 2010-06<br />
Powercell option board - bill of materials 22009063 5 2010-06<br />
Profibus option board - schematics 169068BR B 2005-07-19<br />
Profibus option board - PCB layout 169068H - 2007-03-13<br />
Profibus (harsh) board - bill of materials 175240CA C 2005-07-19<br />
Profibus (panel) board - bill of materials 175241CA C 2005-07-19<br />
ControlNet option Board 22009111 A2 2010-10<br />
Ethernet option board 64057747 5 2009-12<br />
Photomos option board – schematics ES-22009908 5 - 2005-09-07<br />
Photomos option board – PCB layout 22009909 7 - 2008-04-14<br />
Photomos option board –bill of materials 22009913 4 2008-06<br />
Photomos option board – component layout ME-22009911 7 - 2008-04-15<br />
Analog option board - Schematics 169070AR - 2005-01-20<br />
Analog option board - bill of materials 72216499C - 2009-02<br />
Analog option board - PCB trace 72216508X - 2009-02<br />
Flowmeter option board - Schematics 175261R 0 2009-05<br />
Flowmeter option board - bill of materials 64067127 0 2009-05<br />
Flowmeter option board - PCB layout 64067126 0 2009-05<br />
PDX option board - Schematics 174897R 3 2010-04<br />
PDX option board - bill of materials 64064718 6 2010-04<br />
PDX option board - PCB layout 64064717 1 2010-04<br />
IND780 Gasket - Harsh 157780A - 2004-11-17<br />
IND780 Gasket – Panel 176941B B 2005-11-01<br />
00-IC-F0060 – Issue 4.1 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 4 of 5
[13] Schedule<br />
[14] <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICATE</strong> No.<br />
DEMKO 07 ATEX 0520819X<br />
Report: 10NK02765<br />
[17] Special conditions for safe use:<br />
Model IND 780 panel shall be mounted in an enclosure with a minimum ingress protection rating of<br />
at least IP65 as defined in EN60529.<br />
All cable entry devices and blanking elements shall be ATEX certified and suitable for at least IP65 (Panel) or IP69K (Harsh) and correctly<br />
installed.<br />
IDNET port does not meet ATEX Zone 2 wiring methods therefore ATEX certified cable glands must be used.<br />
Both versions of the IND780 terminal shall be used only in environments where UV light cannot influence the non-metallic parts.<br />
Provision shall be made to prevent the rated voltage being exceeded by the transient disturbances of more than 40%.<br />
[18] Essential Health and Safety Requirements<br />
Met by compliance with the standards EN 60079-0:2006, EN 60079-0:2009, EN 60079-15:2005, EN 60079-31:2009<br />
Additional information<br />
The Model IND780 Harsh has in addition passed the tests for Ingress Protection to IP69K in accordance with EN60529, Edition 2.1 +<br />
Corr. 1:2003 + Corr. 2:2007; and DIN 40 050 Part 9 DATED May 1993.<br />
The Model IND780 Panel has in addition passed the tests for Ingress Protection to IP65 in accordance with EN60529, Edition 2.1 + Corr.<br />
1:2003 + Corr. 2:2007.<br />
00-IC-F0060 – Issue 4.1 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 5 of 5