OPTICAL LENGTH AND VELOCITY SENSOR OPTIPACT
OPTICAL LENGTH AND VELOCITY SENSOR OPTIPACT
OPTICAL LENGTH AND VELOCITY SENSOR OPTIPACT
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>OPTICAL</strong> <strong>LENGTH</strong> <strong>AND</strong> <strong>VELOCITY</strong> <strong>SENSOR</strong><br />
<strong>OPTIPACT</strong><br />
Optics and Illumination<br />
Sensor OPT-F1 OPT-S1 OPT-M1<br />
Nominal<br />
Working Distance (*)<br />
15.5 mm (0.6 in) 40 mm (1.5 in) 180 mm (7 in)<br />
Working Distance Tolerance ± 10 % ± 10 % ± 6 %<br />
Typical Measurement Area<br />
< 4 mm²<br />
(2 mm x 2 mm)<br />
< 64 mm²<br />
(8 mm x 8 mm)<br />
< 25 mm²<br />
(5 mm x 5 mm)<br />
Illumination<br />
Red LED<br />
(*) Greater working distances available upon request.<br />
Mechanical Data<br />
Sensor OPT-F1 OPT-S1 OPT-M1<br />
Housing<br />
Shock Resistance<br />
(EN 60068-2-27)<br />
Permanent Shock<br />
(EN 60028-2-29)<br />
Fatigue<br />
(EN 60068-2-6)<br />
Weight<br />
(Standard Version)<br />
Aluminum<br />
≤ 25 g (Half Sine, 6 ms) (*)<br />
≤ 10 g (Half Sine, 16 ms) (*)<br />
≤ 1 g (5 Hz ... 200 Hz, sine) (*)<br />
approx. 250 g ( 0.55 lb)<br />
approx. 3.5 kg<br />
(7.72 lb)<br />
Mounting holes M4 M6<br />
(*) Corresponding to class 3M5 (EN 60721-3-3: compliant to applications associated with significant<br />
vibrations, e.g. caused by machines or vehicles, or shocks with high density of energy, e.g. caused by heavy<br />
machines or conveyor belts)<br />
Page 5 E Info OPT F1/S1/M1 Version 6.0<br />
11/2008