Specifications<br />
Ratings<br />
Switching capacity<br />
Insulation voltage<br />
5 to 24 VDC, 1 to 50 mA (resistive load)<br />
30 VDC<br />
Characteristics<br />
Contact configuration<br />
Contact resistance<br />
Insulation resistance<br />
Dielectric strength<br />
Bounce time<br />
Vibration resistance<br />
Shock resistance<br />
Life expectancy<br />
Ambient temperature<br />
SPST-NO<br />
100 mΩ max. (Rated 5 VDC, 1 mA)<br />
100 MΩ min. (at 250 VDC)<br />
500 VAC, 50/60 Hz for 1 min<br />
5 ms max.<br />
Ambient humidity 35% to 85%<br />
Weight<br />
Operating Characteristics<br />
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude<br />
Destruction: 1,000 m/s 2 min. (Approx. 100 G min.)<br />
Malfunction: 100 m/s 2 min. (Approx. 10 G min.)<br />
<strong>B3W</strong>-1000:<br />
General purpose:1,000,000 operations min.<br />
High-force: 300,000 operations min.<br />
<strong>B3W</strong>-4000:<br />
General purpose:3,000,000 operations min.<br />
High-force: 1,000,000 operations min.<br />
-25°C to 70°C (with no icing)<br />
6 x 6 mm: approx. 0.3 g, 12 x 12: approx. 1.00 g<br />
Item <strong>B3W</strong>-1000 <strong>B3W</strong>-4000<br />
General purpose High-force General purpose High-force<br />
Operating force (OF) 1.57 N (160 gf max.) 2.25 N (230 gf max.) 1.96 N (200 gf max.) 3.43 N (350 gf max.)<br />
Reset force (RF min.) 0.2 N (20 gf max.) 0.49 N (50 gf) 0.29 N (30 gf) 0.49 N (50 gf)<br />
Pretravel (PT) 0.25 +0.2 / –0.1 mm 0.3 +0.2 / –0.1 mm<br />
Engineering Data<br />
Operating Force vs. Stroke (Typical)<br />
<strong>B3W</strong>-1<br />
<strong>B3W</strong>-4<br />
Operating force (gf)<br />
High-force<br />
Operating force (gf)<br />
High-force<br />
General purpose<br />
General purpose<br />
Stroke S (mm)<br />
Stroke S (mm)