BCA164 RANGE - Frontier Power Products
BCA164 RANGE - Frontier Power Products
BCA164 RANGE - Frontier Power Products
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BCA-164 7/11/02 11:24 am Page 1<br />
product profile<br />
<strong>BCA164</strong> <strong>RANGE</strong><br />
Voltages<br />
120V - 600V<br />
Outputs<br />
from 8.1 - 35.6 kVA (3 Phase)<br />
FEATURES:<br />
• Specially tailored single bearing generator for the Lister Petter Alpha engine range<br />
• 12 wire reconnectable stator/terminal arrangement<br />
• Class ‘H’ insulation with severe environmental protection as standard<br />
• Self excited control or auxillary winding to provide sustained short circuit capability<br />
• Advanced automatic voltage regulator (AVR) control<br />
• 2/3 pitch winding as standard, to avoid excessive neutral currents<br />
• IP23 as standard<br />
OPTIONS & ACCESSORIES:<br />
• Upgrade to SA465 AVR with improved regulation 0.5%<br />
• Quadrature Droop kit for Parallel Operation<br />
• Anti Condensation Heaters
BCA-164 7/11/02 11:24 am Page 2<br />
product profile<br />
<strong>BCA164</strong> <strong>RANGE</strong><br />
TYPICAL APPLICATIONS:<br />
Combined Heat & <strong>Power</strong><br />
Parallel Operation<br />
Base Load Prime<br />
Standby<br />
Rental<br />
Telecommunication<br />
Due to our policy of continuous improvement, details in this leaflet which were correct at time of printing<br />
may now be due for amendment. Information included must therefore not be regarded as binding<br />
Rating/Ambient<br />
Application/Temp Rise<br />
Voltage<br />
<strong>Power</strong> Factor<br />
BCA 164A kVA<br />
kW<br />
BCA 164B kVA<br />
kW<br />
BCA 164C kVA<br />
kW<br />
BCA 164D kVA<br />
kW<br />
BCA 164E kVA<br />
BCA 164F<br />
kW<br />
kVA<br />
kW<br />
BCA 164G kVA<br />
kW<br />
Winding<br />
Rating/Ambient<br />
Application/Temp Rise<br />
Voltage<br />
<strong>Power</strong> Factor<br />
BCA 164A kVA<br />
kW<br />
BCA 164B kVA<br />
kW<br />
BCA 164C kVA<br />
kW<br />
BCA 164D kVA<br />
kW<br />
BCA 164E kVA<br />
kW<br />
BCA 164F kVA<br />
kW<br />
BCA 164G kVA<br />
kW<br />
©Newage International 2002<br />
3 Phase Ratings for STAMFORD <strong>BCA164</strong> Generators<br />
50Hz (1500 rpm)<br />
Base 40ºC<br />
Continuous 125ºC<br />
380 - 415V<br />
0.8<br />
8.1<br />
6.5<br />
11.0<br />
8.8<br />
13.5<br />
10.8<br />
16.0<br />
12.8<br />
21.4<br />
17.1<br />
26.2<br />
21.0<br />
30.0<br />
24.0<br />
416V<br />
0.8<br />
9.6<br />
7.7<br />
13.0<br />
10.4<br />
16.0<br />
12.8<br />
18.9<br />
15.1<br />
26.1<br />
20.9<br />
30.9<br />
24.7<br />
33.3<br />
26.6<br />
STAMFORD 1 Phase Ratings for STAMFORD <strong>BCA164</strong> Generators<br />
12 Wire Reconnectable<br />
50Hz (1500 rpm) 60Hz (1800 rpm)<br />
Base 40ºC<br />
Continuous 125ºC<br />
220 - 240V<br />
PF 1<br />
4.7<br />
4.7<br />
6.4<br />
6.4<br />
7.8<br />
7.8<br />
9.3<br />
9.3<br />
12.4<br />
12.4<br />
15.1<br />
15.1<br />
17.3<br />
17.3<br />
PF 0.8<br />
4.7<br />
3.8<br />
6.4<br />
5.1<br />
7.8<br />
6.2<br />
9.3<br />
7.4<br />
12.4<br />
9.9<br />
15.1<br />
12.1<br />
17.3<br />
13.8<br />
Base 40ºC<br />
Continuous 125ºC<br />
240V<br />
PF 1<br />
5.6<br />
5.6<br />
7.5<br />
7.5<br />
9.3<br />
9.3<br />
11.0<br />
11.0<br />
15.1<br />
15.1<br />
17.9<br />
17.9<br />
19.3<br />
19.3<br />
PF 0.8<br />
5.6<br />
4.5<br />
7.5<br />
6.0<br />
9.3<br />
7.4<br />
11.0<br />
8.8<br />
15.1<br />
12.1<br />
17.9<br />
14.3<br />
19.3<br />
15.4<br />
60Hz (1800 rpm)<br />
Base 40ºC<br />
Continuous 125ºC<br />
460 - 480V<br />
0.8<br />
10.2<br />
8.2<br />
13.8<br />
11.0<br />
16.9<br />
13.5<br />
20.0<br />
16.0<br />
27.4<br />
21.9<br />
32.6<br />
26.1<br />
35.6<br />
28.5<br />
4Wire Dedicated<br />
50Hz (1500 rpm) 60Hz (1800 rpm)<br />
Base 40ºC<br />
Continuous 125ºC<br />
220 - 240V<br />
PF 1<br />
6.8<br />
6.8<br />
8.4<br />
8.4<br />
11.0<br />
11.0<br />
13.0<br />
13.0<br />
16.6<br />
16.6<br />
20.0<br />
20.0<br />
22.8<br />
22.8<br />
PF 0.8<br />
5.4<br />
4.3<br />
7.4<br />
5.9<br />
9.0<br />
7.2<br />
10.7<br />
8.6<br />
14.3<br />
11.4<br />
17.5<br />
14.0<br />
20.0<br />
16.0<br />
Base 40ºC<br />
Continuous 125ºC<br />
240V<br />
PF 1<br />
8.2<br />
8.2<br />
11.0<br />
11.0<br />
13.5<br />
13.5<br />
16.5<br />
16.5<br />
22.3<br />
22.3<br />
26.1<br />
26.1<br />
30.8<br />
30.8<br />
Standard Winding (311)<br />
PF 0.8<br />
6.4<br />
5.1<br />
8.8<br />
7.0<br />
10.8<br />
8.6<br />
13.5<br />
10.8<br />
17.5<br />
14.0<br />
20.8<br />
16.6<br />
24.0<br />
19.2<br />
PM_<strong>BCA164</strong> PP GB_11.02_02_GB<br />
NEWAGE International Limited PO Box 17 · Barnack Road · Stamford Lincolnshire · PE9 2NB · England<br />
Tel.: +44 (0) 17 80 48 40 00 · Fax: + 44 (0) 17 80 48 41 00 e-mail: info@newage-avkseg.com · internet: www.newage-avkseg.com