15.05.2015 Views

CE EMC TEST REPORT - pc winner international inc.

CE EMC TEST REPORT - pc winner international inc.

CE EMC TEST REPORT - pc winner international inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>CE</strong> <strong>EMC</strong> <strong>TEST</strong> <strong>REPORT</strong><br />

Report No. : EC5N2204<br />

5. Test of Conducted Powerline<br />

Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz on the power and<br />

return leads of the EUT according to the methods defined in European Standard EN55022 Clause 9. The<br />

EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in<br />

section 5.3. The interface cables and equipment positioning were varied within limits of reasonable<br />

applications to determine the position producing maximum conducted emissions.<br />

5.1 Description of Major Test Instruments<br />

• Test Receiver ( R&S ESCS 30 )<br />

Attenuation<br />

10 dB<br />

Start Frequency<br />

0.15 MHz<br />

Stop Frequency<br />

30 MHz<br />

IF Bandwidth<br />

9 KHz<br />

SPORTON International Inc. Page Number : 8 of 54<br />

TEL : 886-2-2696-2468 Issued Date : Dec. 13, 2005<br />

FAX : 886-2-2696-2255