24.05.2015 Views

Sealed Rad. Sources ANG.qxd - Epsilon NDT

Sealed Rad. Sources ANG.qxd - Epsilon NDT

Sealed Rad. Sources ANG.qxd - Epsilon NDT

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Sealed</strong><br />

<strong>Rad</strong>iation <strong>Sources</strong>


The company<br />

POLATOM Sp. z o.o. is an enterprise focused on production and trade activity in the field of<br />

isotope application. Our production range includes radiopharmaceuticals for nuclear medicine,<br />

radiochemicals, standard solutions and reference sources for R&D, and sealed radiation sources<br />

for industrial applications.<br />

POLATOM Sp. z o.o. is present in the market of radioisotope products for over 50 years, until<br />

the end of 2004 in the structure of <strong>Rad</strong>ioisotope Centre POLATOM and since then as a company<br />

Ltd. The company is located in vicinity of the Nuclear Reactor in Otwock-Âwierk, near Warsaw.<br />

Reliable supplier of sealed radiation sources<br />

The quality sealed source for gamma radiography should have active part sizes as small as<br />

possible. POLATOM cares for the quality of your radiographic images and supplies high activity<br />

Ir-192 sources with the smallest active part available in the market.<br />

We have experience, qualifications and facilities to provide the highest level of service in<br />

handling radioactive materials and various types of gamma radiography equipment.<br />

We can offer you reloading of sealed source in your projector or holder in our facility, including<br />

disposal of the spent source, and send back the projector ready to work.<br />

In case you require a source dispatched in our container – we use containers type A or the<br />

following B(U) containers: UKI 4x135; ZKI 4x150; UK12S; UK50S.<br />

The overall sizes, weight and maximum activity for typical containers are specified below:<br />

maximum activity for nuclide<br />

Container type/ Height Diameter Weight Ir-192 Co-60 Se-75 Yb-169<br />

[mm] [mm] [kg] [TBq] [GBq] [TBq] [TBq]<br />

UKI 4x135* 270 146 41 4.99 3.36 37 74<br />

ZKI 4x150* 298 150 65 5.55 3.73 41.15 82.30<br />

UK 12S 330 280 100 44 29.60 370 -<br />

UK 50S 420 325 185 185 74.00 1630 -<br />

* Maximum activity in each of four channels<br />

2


Standards, quality control and safety<br />

POLATOM Sp. z o.o. implemented Quality Assurance System according to PN-EN-ISO 9001: 2001<br />

in desing, production, sales isotopic products and radiopharmaceuticals, services of isotopic<br />

equipment, transport and dispatching of radioactive materials. And also follows the standards<br />

for International Control System of radioactive materials.<br />

ISO 2919 – this international standard establishes a system of classification of sealed<br />

radioactive sources based on tests and specifies general requirements, performance tests,<br />

production tests, marking and certification.<br />

It provides a set of tests by which manufacturer can evaluate the safety of his products in use.<br />

And also specifies the sealed sources classification (performance) requirements for typical use.<br />

Classification of sealed source performance:<br />

Test / Class 1 2 3 4 5 6<br />

Temperature No test -40°C (20min) -40°C (20min) -40°C (20min) -40°C (20min) -40°C (20min)<br />

+80°C (1h) +180°C (1h) +400°C (1h) +600°C (1h) +800°C (1h)<br />

and thermal and thermal and thermal<br />

shock 400°C shock 600°C shock 800°C<br />

to 20°C to 20°C to 20°C<br />

External No test 25kPa 25kPa 25kPa 25kPa 25kPa<br />

pressure absolute to absolute to absolute to absolute to absolute to<br />

atmospheric 2 MPa 7 MPa 70 MPa 170 MPa<br />

pressure absolute absolute absolute absolute<br />

Impact No test 50g from 1m 200g from 1m 2kg from 1m 5kg from 1m 20kg from 1m<br />

Vibrations No test 3x10 min at 3x10 min at 3x30 min<br />

25Hz to 50Hz 25Hz to 50Hz 25Hz to 80Hz<br />

at 5g n peak 5g n peak 1.5mm amplitude<br />

amplitude amplitude and peak to peak<br />

50Hz to 90Hz and 80Hz to<br />

at 0.635mm 2000Hz at<br />

amplitude 20g n peak<br />

peak to peak<br />

and 90Hz to<br />

500Hz at 10g n<br />

Puncture No test 1g from 1m 10g from 1m 50g from 1m 300g from 1m 1kg from 1m<br />

Quality control<br />

Testing for leakage and contamination - ISO 9978.<br />

Wipe test - with a swab or tissue, moistened with ethanol or water, the removed activity is<br />

measured. Acceptance limit: 200 Bq (5 nCi).<br />

Immersion test - in water or other solvent at 50°C for 4 hours and then the activity in the solvent<br />

is measured. Acceptance limit: 200 Bq (5 nCi).<br />

3


Safety<br />

International basic safety standards for protection against ionizing radiation, personal measurements,<br />

measurements of containers, holders, projectors etc. are applied to all our sources. Our priority is to<br />

ensure safety to the user and anyone handling the transport.<br />

The special form sources according to IAEA Special Form - requires tests for sealed sources given<br />

in the IAEA Regulations for the Safe Transport of <strong>Rad</strong>ioactive Material 2005 Edition<br />

No. TS-R-1. This is to determine the acceptable maximum activity for various transport containers.<br />

After each required test the source must be subjected to immersion testing.<br />

<strong>Sealed</strong> <strong>Sources</strong> for <strong>Rad</strong>iography<br />

The following sources are used for approximate steel working thickness:<br />

Source Class A Class B<br />

Ytterbium Yb-169 1 - 15 mm 2 - 12 mm<br />

Selenium Se-75 10 - 40 mm 14 - 40 mm<br />

Iridium Ir-192 20 - 100 mm 20 - 90 mm<br />

Cobalt Co-60 40 - 200 mm 60 - 150 mm<br />

Yb-169 for Al and Ti 10 - 70 mm 25 - 55 mm<br />

Se-75 for Al and Ti 35-120 mm –<br />

Steel thickness may be reduced to 10mm for Ir-192 end to 5 mm for Se-75<br />

Exposure rate at 1 meter<br />

Nuclide Equivalent activity Exposure rate Air KERMA rate<br />

Yb-169 37GBq (1 Ci) 0.125 R/h 1.1 mGy/h<br />

Se-75 37GBq (1 Ci) 0.203 R/h 1.8 mGy/h<br />

Ir-192 37GBq (1 Ci) 0.48 R/h 4.2 mGy/h<br />

Co-60 37GBq (1 Ci) 1.30 R/h 11 mGy/h<br />

4


Ytterbium-169<br />

Main application:<br />

Gamma <strong>Rad</strong>iography<br />

Half-life:<br />

32 days<br />

Recommended working life: 6 months<br />

<strong>Rad</strong>iation energies Eγ [MeV]:<br />

0.063 (43.9%) 0.118 (1.9%) 0.198 (35.1%)<br />

0.094 (2.6%) 0.131 (11.2%) 0.261 (1.7%)<br />

0.110 (17.6%) 0.177 (21.5%) 0.308 (10.8%)<br />

<strong>Rad</strong>ioactive decay:<br />

Yb-169<br />

Days from date of measurement 0 2 4 6 8<br />

0 1.00 0.96 0.92 0.88 0.84<br />

10 0.81 0.77 0.74 0.71 0.68<br />

20 0.65 0.62 0.59 0.57 0.55<br />

30 0.52 0.50 0.48 0.46 0.44<br />

40 0.42 0.40 0.39 0.37 0.35<br />

50 0.34 0.32 0.31 0.30 0.29<br />

60 0.27 0.26 0.25 0.24 0.23<br />

70 0.22 0.21 0.20 0.19 0.18<br />

80 0.18 0.17 0.16 0.15 0.15<br />

90 0.14 0.14 0.13 0.13 0.12<br />

Description:<br />

Capsules:<br />

Identification:<br />

Double titanium capsule argon arc welded, containing<br />

the isotope as pressed ytterbium oxide.<br />

YA<br />

by serial number<br />

Code capsule type Active part Φ [mm] x h [mm] Maximum Activity [GBq] [Ci]<br />

YB1YA YA 1x1 166.5 4.5<br />

YB2YA YA 1.4x1.6 444 12*<br />

YB3YA YA 1(spherical) 259 7*<br />

* activity depends on enrichment of target material<br />

Capsule dimensions and safety performance testing<br />

Code Capsule type External dimensions Capsule material ISO classification<br />

Φ [mm] x h [mm]<br />

YB1YAT YA 5 x 8 titanium C 64445<br />

YA Capsule<br />

5


Selenium-75<br />

Main application:<br />

Gamma <strong>Rad</strong>iography<br />

Half-life:<br />

120 days<br />

Recommended working life: 2 years<br />

<strong>Rad</strong>iation energies Eγ [MeV]:<br />

0.066 (1.1%) 0.121 (17.3%) 0.199 (1.5%) 0.280 (25.2%) 0.401 (11.6%)<br />

0.097 (3.5%) 0.136 (59.0%) 0.265 (59.1%) 0.305 (1.4%) and others<br />

<strong>Rad</strong>ioactive decay:<br />

Se-75<br />

Days from date of measurement 0 4 8 12 16<br />

0 1.0000 0.9771 0.9548 0.9329 0.9116<br />

20 0.8907 0.8703 0.8504 0.8310 0.8120<br />

40 0.7934 0.7752 0.7575 0.7402 0.7232<br />

60 0.7067 0.6905 0.6747 0.6593 0.6442<br />

80 0.6295 0.6151 0.6010 0.5873 0.5738<br />

100 0.5607 0.5479 0.5353 0.5231 0.5111<br />

120 0.4994 0.4880 0.4768 0.4659 0.4553<br />

140 0.4448 0.4347 0.4247 0.4150 0.4055<br />

160 0.3962 0.3872 0.3783 0.3697 0.3612<br />

180 0.3529 0.3449 0.3370 0.3293 0.3217<br />

200 0.3144 0.3072 0.3002 0.2933 0.2866<br />

220 0.2800 0.2736 0.2674 0.2612 0.2553<br />

240 0.2494 0.2437 0.2381 0.2327 0.2274<br />

260 0.2222 0.2171 0.2121 0.2073 0.2025<br />

280 0.1979 0.1934 0.1889 0.1846 0.1804<br />

300 0.1763 0.1722 0.1683 0.1644 0.1608<br />

320 0.1570 0.1534 0.1499 0.1465 0.1431<br />

340 0.1398 0.1366 0.1335 0.1305 0.1275<br />

Description:<br />

Capsules:<br />

Identification:<br />

Double capsule containing the isotope as pressed selenium powder. Internal<br />

titanium capsule laser welded, external stainless steel capsule argon arc welded.<br />

M12<br />

by serial number<br />

Code capsule type Active part Φ [mm] x h [mm] Maximum Activity [GBq] [Ci]<br />

GS75M12.111 M12 1x1 111 3<br />

GS75M12.311 1.5x1.5 296 8<br />

GS75M12.711 2x2 740 20<br />

GS75M12.112 2.5x2.5 1480 40<br />

GS75M12.412 3x3 2960 80<br />

Capsule dimensions and safety performance testing<br />

Code Capsule type External dimensions Capsule material ISO classification<br />

Φ [mm] x h [mm]<br />

GS75M12 M12 6 x 20 Titanium/steel C 63545<br />

6<br />

M12 Capsule


Iridium-192<br />

Main application:<br />

Gamma <strong>Rad</strong>iography<br />

Half-life:<br />

74 days<br />

Recommended working life: 1 year<br />

<strong>Rad</strong>iation energies Eγ [MeV]:<br />

0.206 (3.4%) 0.308 (30.7%) 0.468 (47.0%) 0.589 (4.4%) 0.612 (5.3%)<br />

0.296 (29.6%) 0.316 (82.7%) 0.484 (2.9%) 0.604 (8.2%)<br />

<strong>Rad</strong>ioactive decay:<br />

Ir-192<br />

Days from date<br />

of measurement 0 5<br />

0 1.00 0.95<br />

10 0.91 0.87<br />

20 0.83 0.79<br />

30 0.75 0.72<br />

40 0.69 0.66<br />

50 0.63 0.60<br />

<strong>Rad</strong>ioactive decay:<br />

Ir-192<br />

Days from date<br />

of measurement 0 5<br />

60 0.57 0.54<br />

70 0.52 0.49<br />

80 0.47 0.45<br />

90 0.43 0.41<br />

100 0.39 0.37<br />

110 0.36 0.34<br />

Description:<br />

Capsules:<br />

Identification:<br />

Stainless steel capsule argon arc welded, containing iridium pellets.<br />

HA, HB, YA<br />

by serial number<br />

Code capsule type Active part Φ [mm] x h [mm] Maximum Activity [GBq] [Ci]<br />

IR1HA HA 1.0x0.4 148 4<br />

1.0x0.6 222 6<br />

1.0x1.0 370 10<br />

1.5x1.0 666 18<br />

1.5x1.2 777 21<br />

1.5x1.6 1110 30<br />

2.0x1.0 1184 32<br />

2.0x1.2 1460 38<br />

2.0x1.6 1850 50<br />

2.0x2.0 2294 62<br />

IR1HB HB 3.0x2.0 3700 100<br />

3.0x2.2 4255 115<br />

3.0x2.4 4440 120<br />

3.0x3.0 6475 175<br />

IR1YA YA 3.0x4.0 8140 220<br />

Capsule dimensions and safety performance testing<br />

Code Capsule type External dimensions Capsule material ISO classification<br />

Φ [mm] x h [mm]<br />

IR1HA HA 4x5 Stainless steel (1H18N9T) C 64344<br />

IR1HB HB 4x6 Stainless steel (1H18N9T) C 64344<br />

IR1YA YA 5x8 Stainless steel (1H18N9T) C 64344<br />

7


HA Capsule<br />

HB Capsule<br />

YA Capsule<br />

Cobalt-60<br />

Application:<br />

Gamma radiography and process control, point or linear sources.<br />

Half-life:<br />

5.27 years<br />

Recommended working life: 10 years<br />

<strong>Rad</strong>iation energies Eγ [MeV]:<br />

1.17 (100%) 1.33 (100%)<br />

<strong>Rad</strong>ioactive decay Cobalt-60:<br />

Co-60<br />

Months from date of measurement 0 2 4 6 8<br />

0 1.00 0.98 0.96 0.94 0.92<br />

10 0.90 0.88 0.86 0.84 0.82<br />

20 0.80 0.79 0.77 0.75 0.74<br />

30 0.72 0.70 0.69 0.67 0.66<br />

40 0.65 0.63 0.62 0.60 0.59<br />

50 0.58 0.57 0.55 0.54 0.53<br />

8


Point sources in capsules: HB, YA, HB/HK<br />

Description:<br />

Identification:<br />

Nickel plated disks of cobalt are sealed in stainless steel capsule welded<br />

in argon arc. Alternatively in double stainless steel capsule.<br />

by serial number<br />

Code capsule type Active part Φ [mm] x h [mm] Maximum Activity [GBq] [Ci]<br />

CO1HB HB 3x3 37 1<br />

CO1YA YA 3x3 37 1<br />

CO1HK HB/HK 3x3 370 10<br />

Capsule dimensions and safety performance testing<br />

Code Capsule type External dimensions Capsule material ISO classification<br />

Φ [mm] x h [mm]<br />

CO1HB HB 4x6 Stainless steel C 64344<br />

(1H18N9T)<br />

CO1YA YA 5x8 Stainless steel C 64344<br />

CO1HK HB/HK 5x10 Stainless steel C 64344<br />

HB Capsule<br />

YA Capsule<br />

HB/HK Capsule<br />

9


Linear <strong>Sources</strong> in capsules: LA - LG<br />

Description:<br />

Identification:<br />

Nickel plated rods 40mm long, diameter 1mm. The active rods of cobalt are sealed<br />

in aluminium and stainless steel capsules welded in argon arc.<br />

by serial number<br />

Code Capsule type External dimensions Active part Maximum Activity<br />

Φ [mm] x h [mm] Φ [mm] x h [mm] [GBq] [mCi]<br />

CO1LA LA 8x50-490 1x40-480<br />

CO1LB LB 8x500 1x490<br />

CO1LC LC 8x600 1x590<br />

CO1LD LD 8x750 1x740 1.85 50<br />

CO1LE LE 8x900 1x890<br />

CO1LF LF 8x1100 1x1090<br />

CO1LG LG 8x1300 1x1290<br />

Container for linear sources<br />

Source loading services<br />

The sources may be loaded<br />

to various types of projector<br />

holders<br />

Gammamat holder<br />

Sentinel holder<br />

10


SI Units<br />

The following units are recommended for radioactivity and absorbed dose. The equivalence<br />

between the SI units and traditional units is specified in the table below.<br />

Physical quantity SI unit Traditional unit Relationship<br />

<strong>Rad</strong>ioactivity becquerel [Bq] curie [Ci] 1 Ci = 3.7x10 10 Bq<br />

1Bq = 2.7x10 -11 Ci<br />

Absorbed dose gray [Gy] rad 1 rad = 0.01 Gy<br />

1 Gy = 100 rad<br />

Changing the units<br />

Curies to Becquerels<br />

0.1 mCi 3.7 MBq<br />

0.2 mCi 7.4 MBq<br />

0.5 mCi 18.5 MBq<br />

1 mCi 37 MBq<br />

2 mCi 74 MBq<br />

5 mCi 185 MBq<br />

10 mCi 370 MBq<br />

20 mCi 740 MBq<br />

50 mCi 1.85 GBq<br />

100 mCi 3.7 GBq<br />

200 mCi 7.4 GBq<br />

500 mCi 18.5 GBq<br />

1 Ci 37 GBq<br />

2 Ci 74 GBq<br />

5 Ci 185 GBq<br />

10 Ci 370 GBq<br />

100 Ci 3.7 TBq<br />

Becquerels to Curies<br />

1 MBq 0.027 mCi<br />

2 MBq 0.054 mCi<br />

5 MBq 0.135 mCi<br />

10 MBq 0.270 mCi<br />

20 MBq 0.540 mCi<br />

50 MBq 1.350 mCi<br />

100 MBq 2.703 mCi<br />

200 MBq 5.405 mCi<br />

500 MBq 13.50 mCi<br />

1 GBq 27.03 mCi<br />

2 GBq 54.04 mCi<br />

5 GBq 135.0 mCi<br />

10 GBq 270.3 mCi<br />

20 GBq 540.5 mCi<br />

50 GBq 1.350 Ci<br />

100 GBq 2.703 Ci<br />

1 TBq 27.03 Ci<br />

11


POLATOM Sp. z o.o. 05-400 Otwock-Świerk, POLAND<br />

phone: (+48 22) 718 07 37; 718 07 64; 718 07 54, fax: (+48 22) 779 73 81<br />

e-mail: polatom@polatom.pl, www.polatom.pl<br />

2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!