Small in size, big on safety<br />

BEC44 range<br />

<strong>Conlog</strong>’s new BEC44 range builds upon the heritage of the world’s<br />

first, and smallest, DIN rail mounted prepayment meter. The compact<br />

design ensures that multiple units can be housed in one enclosure, with the<br />

associated installation cost saving and enhanced security as consumers<br />

are unable to access the metering device. In addition, the meter provides<br />

enhanced tamper detection as well as galvanic isolation as standard.<br />

Features<br />

> Reverse energy measurement<br />

> Configurable tamper detection<br />

> Programmable under and over voltage<br />

> Thermal shutdown protection<br />

> Display of the trip condition<br />

> Delayed reconnection<br />

> Communication status<br />

We see a world where we<br />

can all achieve more while<br />

using less<br />

We help utilities maximise<br />

their service delivery<br />

Our products, solutions<br />

and services are simple,<br />

efficient and innovative


Product specifications<br />

Voltage ratings<br />

Nominal voltage (-20% +±5%)<br />

Supply frequency (±5%)<br />

110VAC - 127VAC<br />

60Hz<br />

220VAC - 240VAC<br />

50Hz<br />

Current ratings<br />

Base current (I b )<br />

Max current (I max )<br />

Min starting current<br />

Class 1<br />

Class 2<br />

Utilisation category<br />

5A<br />

100A*<br />

20mA<br />

25mA<br />

UC2<br />

Nominal power<br />

consumption<br />

Accuracy<br />

Over voltage rating<br />

Short circuit rating<br />

Protection<br />

Environmental<br />

Operating temperature<br />

Storage temperature<br />

Humidity<br />

IP rating<br />

RF immunity<br />

1.6W / 9VA<br />

Class 1 and 2 (maintained throughout life cycle of product)<br />

420VAC for 48 hours<br />

Short-circuit withstand 3.0kA<br />

Power overload<br />

Thermal overload<br />

Current overload<br />

Line / load reversal<br />

Over / under voltage Galvanic isolation<br />

Delayed reconnection<br />

-10 °C to +55°C<br />

-25 °C to +70 °C<br />

39<br />

95% non-condensing<br />

IP 54<br />

30V/m<br />

71.55<br />

70.24<br />

Status indicators<br />

Installation<br />

Footprint<br />

Insulation class<br />

Terminals<br />

Type<br />

Maximum size<br />

Load / power status<br />

MCU / UIU communication<br />

Rate LED (1000 pulses / kWh)<br />

DIN rail mounted (35mm)<br />

Double insulation<br />

Live Neutral Communication<br />

Cage clamp Cage clamp Spring clamp<br />

25mm² 6mm² 0.7mm²<br />

148<br />

Security<br />

Meter housing<br />

Tamper protection<br />

Standards<br />

Packaging<br />

Units per carton<br />

Carton weight (incl box)<br />

Security seals<br />

Tamper terminal cover<br />

Load disconnection on tamper detection<br />

IEC 62052-11 IEC 60068-2-6<br />

IEC 62053-21 SANS 1524-1<br />

IEC 62055-41 ISO 14001:2004<br />

IEC 62056-21 ISO 9001:2008<br />

IEC 60068-2-27 ISO 18001:2007<br />

10<br />

3kg<br />

For further packaging information, kindly contact <strong>Conlog</strong><br />

* Subject to ambient conditions<br />

<strong>Conlog</strong><br />

P O Box 2332, Durban, 4000, South Africa<br />

Tel +27 (31) 268-1111 Fax +27 (31) 268-1500<br />

www.conlog.co.za<br />