Small in size, big on safety<br />
BEC44 range<br />
<strong>Conlog</strong>’s new BEC44 range builds upon the heritage of the world’s<br />
first, and smallest, DIN rail mounted prepayment meter. The compact<br />
design ensures that multiple units can be housed in one enclosure, with the<br />
associated installation cost saving and enhanced security as consumers<br />
are unable to access the metering device. In addition, the meter provides<br />
enhanced tamper detection as well as galvanic isolation as standard.<br />
Features<br />
> Reverse energy measurement<br />
> Configurable tamper detection<br />
> Programmable under and over voltage<br />
> Thermal shutdown protection<br />
> Display of the trip condition<br />
> Delayed reconnection<br />
> Communication status<br />
We see a world where we<br />
can all achieve more while<br />
using less<br />
We help utilities maximise<br />
their service delivery<br />
Our products, solutions<br />
and services are simple,<br />
efficient and innovative
Product specifications<br />
Voltage ratings<br />
Nominal voltage (-20% +±5%)<br />
Supply frequency (±5%)<br />
110VAC - 127VAC<br />
60Hz<br />
220VAC - 240VAC<br />
50Hz<br />
Current ratings<br />
Base current (I b )<br />
Max current (I max )<br />
Min starting current<br />
Class 1<br />
Class 2<br />
Utilisation category<br />
5A<br />
100A*<br />
20mA<br />
25mA<br />
UC2<br />
Nominal power<br />
consumption<br />
Accuracy<br />
Over voltage rating<br />
Short circuit rating<br />
Protection<br />
Environmental<br />
Operating temperature<br />
Storage temperature<br />
Humidity<br />
IP rating<br />
RF immunity<br />
1.6W / 9VA<br />
Class 1 and 2 (maintained throughout life cycle of product)<br />
420VAC for 48 hours<br />
Short-circuit withstand 3.0kA<br />
Power overload<br />
Thermal overload<br />
Current overload<br />
Line / load reversal<br />
Over / under voltage Galvanic isolation<br />
Delayed reconnection<br />
-10 °C to +55°C<br />
-25 °C to +70 °C<br />
39<br />
95% non-condensing<br />
IP 54<br />
30V/m<br />
71.55<br />
70.24<br />
Status indicators<br />
Installation<br />
Footprint<br />
Insulation class<br />
Terminals<br />
Type<br />
Maximum size<br />
Load / power status<br />
MCU / UIU communication<br />
Rate LED (1000 pulses / kWh)<br />
DIN rail mounted (35mm)<br />
Double insulation<br />
Live Neutral Communication<br />
Cage clamp Cage clamp Spring clamp<br />
25mm² 6mm² 0.7mm²<br />
148<br />
Security<br />
Meter housing<br />
Tamper protection<br />
Standards<br />
Packaging<br />
Units per carton<br />
Carton weight (incl box)<br />
Security seals<br />
Tamper terminal cover<br />
Load disconnection on tamper detection<br />
IEC 62052-11 IEC 60068-2-6<br />
IEC 62053-21 SANS 1524-1<br />
IEC 62055-41 ISO 14001:2004<br />
IEC 62056-21 ISO 9001:2008<br />
IEC 60068-2-27 ISO 18001:2007<br />
10<br />
3kg<br />
For further packaging information, kindly contact <strong>Conlog</strong><br />
* Subject to ambient conditions<br />
<strong>Conlog</strong><br />
P O Box 2332, Durban, 4000, South Africa<br />
Tel +27 (31) 268-1111 Fax +27 (31) 268-1500<br />