<strong>End</strong>-<strong>Suction</strong> Pumps<br />

The protection of life is not a matter for compromise.<br />

This is particularly true for fire protection systems where they are<br />

only as strong as their ‘weakest link’ and compromise may result<br />

in avoidable loss of life or property.<br />

That is why SPP fire pumps are designed specifically for the very<br />

particular needs of fire protection and are approved by most of the<br />

major fire protection bodies around the world.<br />

Fire Pump approvals are of course ess<strong>en</strong>tial for the peace of mind<br />

of those that build, operate or use buildings. The approval<br />

demonstrates that an indep<strong>en</strong>d<strong>en</strong>t assessm<strong>en</strong>t has be<strong>en</strong> made of<br />

the Fire Pump Manufacturer’s packages and processes and that<br />

they conform to industry standards.<br />

<strong>End</strong> <strong>Suction</strong> Fire Pumps<br />

SPP Pumps have be<strong>en</strong> manufacturing fire pumps for over 100<br />

years and has one of the widest ranges of approvals of any<br />

manufacturer in the world. Experi<strong>en</strong>ce gained from extreme<br />

<strong>en</strong>vironm<strong>en</strong>ts such as off-shore oil & gas installations has led to<br />

the creation of the SPP Unistream and Eurostream range of<br />

<strong>en</strong>d-suction fire pumps, approved for fire protection by the Loss<br />

Prev<strong>en</strong>tion Certification Board (LPCB), Factory Mutual Approvals<br />

(FM) and Underwriter Laboratories Inc. (UL), all of which are fully<br />

compliant to NFPA 20. Other approvals held by SPP include<br />

APSAD, CNBOP, ZUS and PSB.<br />

SPP <strong>End</strong>-<strong>Suction</strong> fire pumps can be found in most<br />

types of installation around the world including:<br />

• Office buildings<br />

• Hospitals<br />

• Airports<br />

• Manufacturing facilities<br />

• Power stations<br />

• Pharmaceutical facilities<br />

• Schools/colleges<br />

• Warehouses<br />

Typical Applications:<br />

• Sprinkler systems<br />

• Hydrant systems<br />

• Deluge systems<br />

• Monitor systems<br />

• <strong>Water</strong> curtain<br />

SPP PUMPS<br />

<strong>Jans<strong>en</strong></strong> Pomp<strong>en</strong>techniek T: +31(0)485-371318 E: info@pomp<strong>en</strong>techniek.nl


SPP <strong>End</strong>-<strong>Suction</strong> fire pumps are available for duties ranging from 200 USgpm to 1500 USgpm and are suitable for electric or diesel drives. The table<br />

below demonstrates how the range of <strong>End</strong>-<strong>Suction</strong> pumps are designed to meet most normal requirem<strong>en</strong>ts. SPP also supplies Vertical Turbine, Split Case<br />

and Multi-Stage fire pumps. SPP <strong>End</strong>-<strong>Suction</strong> pumps are available with either inch or metric fittings.<br />

Examples of FM and UL Approvals up to 1500 USgpm<br />

160.00<br />

140.00<br />

120.00<br />

100.00<br />

80.00<br />

60.00<br />

40.00<br />

20.00<br />

0.00<br />

200<br />

AVO3N<br />

3500<br />

200<br />

KP08V<br />

2950<br />

200<br />

KP06D<br />

2950<br />

200<br />

KP05E<br />

2600<br />

200<br />

KP08V<br />

3500<br />

200<br />

KP05E<br />

2950<br />

250<br />

AVO3N<br />

3500<br />

250<br />

KPO8V<br />

2950<br />

250<br />

KPO6D<br />

2950<br />

250<br />

KPO8V<br />

3500<br />

250<br />

KPO5E<br />

2950<br />

250<br />

KPO5E<br />

2950<br />

300<br />

AVO3N<br />

3500<br />

300<br />

KPO8V<br />

2950<br />

300<br />

KPO6D<br />

2950<br />

300<br />

KPO8E<br />

2350<br />

300<br />

KPO8E<br />

2600<br />

300<br />

KPO8V<br />

3500<br />

300<br />

KPO8E<br />

2800<br />

300<br />

KPO8E<br />

2950<br />

300<br />

KPO5E<br />

2950<br />

400<br />

AVO3N<br />

3500<br />

400<br />

KPO8V<br />

2950<br />

400<br />

KPO8E<br />

2350<br />

400<br />

KP12Y<br />

1450<br />

400<br />

KP06D<br />

2950<br />

400<br />

KP08E<br />

2600<br />

400<br />

KP12Y<br />

1500<br />

400<br />

KP08V<br />

3500<br />

400<br />

KP08E<br />

2800<br />

400<br />

KP08E<br />

2950<br />

400<br />

KP12Y<br />

1800<br />

400<br />

KP12Y<br />

1900<br />

180.00<br />

160.00<br />

140.00<br />

120.00<br />

100.00<br />

80.00<br />

60.00<br />

40.00<br />

20.00<br />

0.00<br />

450<br />

AVO3N<br />

3500<br />

450<br />

KPO8V<br />

2950<br />

450<br />

KPO8E<br />

2350<br />

450<br />

KPO8E<br />

2600<br />

450<br />

KPO8V<br />

3500<br />

450<br />

KPO8E<br />

2800<br />

450<br />

KPO8E<br />

2950<br />

500<br />

KPO8E<br />

2350<br />

500<br />

KPO8E<br />

2600<br />

500<br />

KPO8V<br />

3500<br />

500<br />

KPO8E<br />

2800<br />

500<br />

KP08E<br />

2950<br />

500<br />

KP15Y<br />

2600<br />

500<br />

KP15Y<br />

2800<br />

500<br />

KP15Y<br />

2950<br />

500<br />

KP15Y<br />

3000<br />

750<br />

KP15Y<br />

2600<br />

750<br />

KP15Y<br />

2800<br />

750<br />

KP15Y<br />

2950<br />

750<br />

KP15Y<br />

3000<br />

1000<br />

KP15Y<br />

2600<br />

1000<br />

KP15Y<br />

2800<br />

1000<br />

KP15Y<br />

2950<br />

1000<br />

KP15Y<br />

3000<br />

1250<br />

KP15Y<br />

2600<br />

1250<br />

KP15Y<br />

2800<br />

1250<br />

KP15Y<br />

2950<br />

1250<br />

KP15Y<br />

3000<br />

1500<br />

KP15Y<br />

2800<br />

1500<br />

KP15Y<br />

2950<br />

1500<br />

KP15Y<br />

3000<br />

For detailed information on the LPCB range coverage please refer to the<br />

LPCB’s List of Approved Fire and Security Products and Services<br />

(Red Book) or visit the website at www.brecertification.co.uk.<br />

Controllers<br />

Due to frequ<strong>en</strong>t updates to the FM and UL range coverage, please refer to<br />

the following sources for up to date information:<br />

For FM listings please refer to the FM Approval Guide<br />

For UL listings please refer to the UL website at www.ul.com<br />

To <strong>en</strong>sure total compatibility of equipm<strong>en</strong>t, controllers are manufactured or sourced by SPP. These can be Direct-On-Line, Star-Delta, Auto-Transformer,<br />

Soft Start, etc. Diesel controllers can be supplied for 12V or 24V DC electric, air or hydraulic cranking. Controllers can be supplied free standing or<br />

mounted on the baseplate, completely wired and connected into the pump set package. Remote alarm panels can also be supplied.<br />

<strong>Jans<strong>en</strong></strong> Pomp<strong>en</strong>techniek T: +31(0)485-371318 E: info@pomp<strong>en</strong>techniek.nl

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!