gas sensor/ transmitter - Trolex
gas sensor/ transmitter - Trolex
gas sensor/ transmitter - Trolex
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
GAS SENSOR/<br />
TRANSMITTER<br />
CAR PARKS<br />
•<br />
TUNNELS<br />
•<br />
STORAGE AREAS<br />
•<br />
LPG PLANTS<br />
•<br />
BOTTLING PLANTS<br />
•<br />
CHEMICAL<br />
PROCESSING<br />
•<br />
POWER<br />
DISTRIBUTION<br />
•<br />
TELECOMS<br />
•<br />
WATER UTILITIES<br />
•<br />
WASTE<br />
MANAGEMENT<br />
•<br />
INCINERATORS<br />
•<br />
PUBLIC BUILDINGS<br />
SAFETY MONITORING of<br />
TOXIC and FLAMMABLE<br />
<strong>gas</strong>es in heavy duty<br />
applications<br />
modular, intelligent,<br />
plug-in <strong>gas</strong> sensing<br />
module that<br />
thinks for itself...<br />
...ultimate ease of installation<br />
and maintenance<br />
1 /9<br />
ISSUE B 10/08
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
SENTRO <strong>gas</strong> <strong>sensor</strong>s incorporate advanced design technology<br />
to combine simple installation with rapid, cost-efficient maintenance<br />
and the highest safety performance...<br />
...built to<br />
withstand<br />
adversity<br />
HIGH STRENGTH<br />
MOULDED HOUSING<br />
• Dual wall construction for<br />
maximum impact strength.<br />
• Field mounting; sealed<br />
against dust and moisture<br />
to IP65 standard.<br />
• EMC protected.<br />
LARGE LCD READOUT<br />
• High-brightness, dot matrix<br />
display provides clear<br />
information with direct<br />
on-screen instructions and<br />
diagnostic data.<br />
PRE-CALIBRATED<br />
GAS SENSING<br />
MODULES<br />
• Intelligent and standardised<br />
sensing modules can be<br />
interchanged in seconds.<br />
• Data storage of all sensing<br />
parameters and service history.<br />
• No danger of inserting a wrong<br />
module; up to 20 insert codes<br />
can be user configured and<br />
SENTRO will automatically<br />
identify the module.<br />
• Data logging.<br />
SECURE, EASY<br />
CONNECTION<br />
• Large terminals with open visual<br />
access; can easily clamp two<br />
4mm 2 conductors.<br />
• Spring loaded wire clamping<br />
plate ensures safe and<br />
vibration secure connections.<br />
RAPID & ROBUST MOUNTING<br />
• All SENTRO series housings are designed to easily<br />
fit onto standard Unistrut rails.<br />
SIMPLE CABLE<br />
TERMINATION<br />
• Large spacious terminal<br />
chamber with adequate space<br />
for terminating heavy plant<br />
cables.<br />
• Two M20 threaded cable entries<br />
for simple fitting of cable glands.<br />
• Hinged segregation cover for<br />
added operator safety.<br />
ISSUE B 10/08<br />
2 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
sentro modules...<br />
There is a wide choice of sensing modules and each one stores all the<br />
necessary data about its type identification, sensing range and specific<br />
calibration. This data is automatically recognised by SENTRO when the<br />
eModule is plugged in.<br />
4000 points of date-stamped measurements are also logged and can be<br />
reviewed by connecting the module to a USB port of a standard PC.<br />
The service history of the module and the condition of the sensing<br />
element are also recorded.<br />
The eModules are pre-calibrated so can be substituted at any time by a<br />
replacement module – usually of the same type, but an alternative may<br />
be inserted if required.<br />
Security coding can be used to ensure that the same type of SENTRO<br />
eModule is always used.<br />
...'smart'<br />
<strong>gas</strong><br />
modules<br />
SENTRO eModule<br />
TOXIC GASES • ELECTROCHEMICAL CELLS<br />
SENTRO eModule for monitoring toxic <strong>gas</strong>es present in the environment using<br />
electrochemical cells, combining good sensitivity at low <strong>gas</strong> concentrations with<br />
high range capability and excellent stability.<br />
The cells have a natural life of about two years, dependent upon monitoring<br />
conditions and the module can be quickly replaced and serviced at the end of its<br />
working life.<br />
Toxic <strong>gas</strong> SENTRO eModules have very low power consumption so enabling the<br />
4...20mA two wire, line powered version of SENTRO (TX6352) to be used when<br />
preferred.<br />
TX6350.250.50 Carbon monoxide 0...50ppm<br />
TX6350.250.250 Carbon monoxide 0...250ppm<br />
TX6350.250.500 Carbon monoxide 0...500ppm<br />
TX6350.251 Hydrogen sulphide 0...100ppm<br />
TX6350.252 Sulphur dioxide 0...20ppm<br />
TX6350.254 Nitrogen dioxide 0...20ppm<br />
TX6350.255 Chlorine 0...10ppm<br />
TX6350.257 Oxygen 0...25%<br />
TX6350.259 Nitrous oxide 0...200ppm<br />
TX6350.261 Hydrogen 0...1000ppm<br />
ISSUE B 10/08<br />
3 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
SENTRO eModule<br />
FLAMMABLE GASES • POISON RESISTANT CATALYTIC SENSOR<br />
SENTRO eModule utilising a poison resistant catalytic combustion <strong>sensor</strong> to<br />
monitor flammable <strong>gas</strong>es present in the atmosphere. The <strong>sensor</strong> will respond to<br />
most flammable <strong>gas</strong>es and vapours to varying degrees; it is normally calibrated<br />
to methane in terms of %LEL or %volume. Very good sensitivity at low levels of<br />
concentration but not suitable for use above the LEL level. Calibration for other<br />
flammable <strong>gas</strong>es can also be provided.<br />
The relatively large mass of the sensing element assures a long and reliable<br />
operating life with exceptional stability, even in conditions of high vibration.<br />
The natural life of the <strong>sensor</strong> is about five years depending upon the monitoring<br />
conditions and the module can be quickly replaced and serviced at the end of its<br />
operating life.<br />
TX6350.240 Methane 0...100% LEL<br />
Can also be calibrated for other flammable <strong>gas</strong>es to specification<br />
eg. LPG, Propane, Butane, etc.<br />
SENTRO eModule<br />
CARBON DIOXIDE/ METHANE GASES • INFRARED SENSOR<br />
SENTRO eModules with an infrared <strong>sensor</strong> are used for monitoring environmental<br />
concentrations of either carbon dioxide or methane <strong>gas</strong>es.<br />
This <strong>sensor</strong> is highly specific to the selected <strong>gas</strong> and exhibits consistent sensing<br />
accuracy with superior long term stability; so minimising calibration and<br />
maintenance.<br />
The essentially linear response and high sensitivity of the <strong>sensor</strong> means that it<br />
can be calibrated equally well for low <strong>gas</strong> concentrations and high<br />
concentrations up to 100% by volume.<br />
TX6353.242 Methane 0...100% v/v<br />
TX6353.243 Methane 0...100% LEL<br />
TX6353.253 Carbon dioxide 0...2000ppm<br />
GAS SENSING MODULE SETTINGS<br />
Gas sensing modules are normally supplied with preset function data and no<br />
further setting-up will be necessary – SENTRO will immediately recognise the<br />
module and its settings when it is loaded.<br />
Module parameters can also be setup to individual requirements when requested.<br />
Scaling, duty text and setpoint alarm values are pre-programmed.<br />
ISSUE B 10/08<br />
4 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
convenient and rapid calibration...<br />
A <strong>gas</strong> <strong>sensor</strong> will not protect lives and plant equipment if it is out of<br />
service, waiting for a complex calibration procedure by a specialist<br />
technician – so swift and simple re-calibration, at the point of use, is<br />
crucial to efficient performance and safety.<br />
SENTRO achieves this in a choice of<br />
three uniquely simple ways:<br />
REPLACE THE MODULE<br />
choice of<br />
calibration<br />
methods<br />
• False alarms will be automatically inhibited during change-out.<br />
• The SENTRO cover stays anchored in place, ready for 'quick' replacement.<br />
IR COMMANDER<br />
• Apply test <strong>gas</strong> using the convenient<br />
bayonet fixed <strong>gas</strong> hood and<br />
calibrate using the two button<br />
remote IR Commander –<br />
no need to remove the cover.<br />
• Follow the simple,<br />
step-by-step, on-screen<br />
instructions.<br />
• The same thing can be done<br />
using the internal calibration<br />
buttons if required.<br />
ISSUE B 10/08<br />
5 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
efficient maintenance...<br />
Service and maintenance can be a high cost factor in supporting an<br />
efficient and safe <strong>gas</strong> monitoring programme.<br />
One of the main objectives of SENTRO was to move on from<br />
traditional methods and produce a <strong>sensor</strong> that could be easily<br />
maintained by Plant Engineers without the need for intervention by<br />
qualified specialists.<br />
Whatever service needs to be carried out, it is simple and quick –<br />
engendering confidence in the product so ensuring a greater level<br />
of plant safety.<br />
...highly<br />
costeffective<br />
Recalibrate by changing<br />
the <strong>gas</strong> sensing module.<br />
Simple push-in robust filter system can<br />
be changed in seconds without tools.<br />
The complete main<br />
internal control module<br />
can be changed if major<br />
service is required.<br />
Rapid calibration using<br />
the IR Commander.<br />
Clear and concise<br />
diagnostic messages<br />
and function data.<br />
Additional detailed technical data is available in the<br />
SENTRO INSTALLATION AND OPERATING DATA<br />
trolex.com<br />
ISSUE B 10/08<br />
6 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
choice of power and output options...<br />
One of the most important characteristics of a <strong>sensor</strong> is its ability to<br />
integrate directly in a trouble-free way, with other plant equipment<br />
and monitoring devices. SENTRO has no equal in its choice of direct<br />
power-up options and a range of fully conditioned output signals to<br />
satisfy most plant preferences – just forget about additional<br />
power-packs or signal interface devices; they won't be needed.<br />
• 230V • 230V ac ac<br />
POWER POWER IN • IN 110V • 110V ac ac<br />
• 24V • dc 24V dc<br />
• 4...20mA • 4...20mA<br />
• Dual • Dual contacts contacts<br />
• RS485 • RS485 data data<br />
OUTPUT OUTPUT SIGNAL SIGNAL<br />
sentro<br />
integrates<br />
directly<br />
trouble-free installation...<br />
STANDARD POWER SOURCE<br />
Uses standard locally available power sources;<br />
24V dc or 110V ac or 230V ac.<br />
DIRECT SIGNAL INTERFACE<br />
Output signal options, all able to interface<br />
DIRECTLY with standard industrial equipment.<br />
• Industry standard 4...20mA output<br />
with optional 4 wire connection or<br />
2 wire, line powered format where<br />
toxic <strong>gas</strong> <strong>sensor</strong>s are used.<br />
4<br />
20mA<br />
• Dual contacts with audio/visual alarm<br />
warnings incorporated, so doing away<br />
with remote auxiliary alarm devices.<br />
• Cable saving SENTRO RS485<br />
datacomms, with up to 32 SENTRO<br />
<strong>gas</strong> <strong>sensor</strong>s on a single data cable.<br />
RS485 DATACOMMS<br />
mV<br />
mV<br />
ISSUE B 10/08<br />
7 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
technical details...<br />
Humidity:<br />
95% RH non-condensing.<br />
Protection Classification: Dust & waterproof to IP65.<br />
Operating Temp. Range: –20°C...40°C.<br />
Housing Material: Stainless steel reinforced polymer.<br />
Nett Weight: 550g.<br />
EMC:<br />
EC directive 89/336/EEC.<br />
Dimensions:<br />
25.0<br />
57.0<br />
85.0 CTRS<br />
fixing holes<br />
LCD<br />
73.0<br />
<strong>gas</strong> entry port<br />
149.0<br />
140.0<br />
2 Ø6.5<br />
fixing holes<br />
67.0<br />
<strong>sensor</strong>s<br />
and<br />
systems<br />
complete <strong>gas</strong> sensing systems from <strong>Trolex</strong><br />
to ensure total system compatibility...<br />
40.0<br />
98.0<br />
2 x M20<br />
cable entries<br />
TRIP AMPLIFIER<br />
for use with analogue output<br />
SENTRO <strong>gas</strong> <strong>sensor</strong>s.<br />
CONFIGURABLE SENSOR CONTROLLER<br />
for monitoring up to 8 SENTRO <strong>gas</strong> <strong>sensor</strong>s.<br />
COMMANDER DISTRIBUTED I/O SYSTEM<br />
for large scale <strong>gas</strong> and general plant<br />
monitoring systems.<br />
ISSUE B 10/08<br />
8 /9
T X 6 3 5 1 . 0 3 T X 6 3 5 2 . 0 3<br />
SENTRO GAS SENSOR/TRANSMITTER<br />
order reference...<br />
T X 6 3 5 1 . 0 3<br />
TOXIC SENSOR/TRANSMITTER<br />
Please specify: • 24V dc supply (102)<br />
• 110V ac supply (105)<br />
• 230V ac supply (106)<br />
• 4...20mA output (4 wire) (12)<br />
• Relay contact output (14)<br />
• RS485 output (15)<br />
T X 6 3 5 2 . 0 3<br />
SENTRO SENSOR/TRANSMITTER<br />
Please specify: • 4...20mA output (12)<br />
(2 wire, line powered – Electrochemical cells only).<br />
making<br />
industry<br />
safer...<br />
TX6350<br />
SENTRO eModule (Gas)<br />
Please order separately – see page 3.<br />
TX9089<br />
IR COMMANDER<br />
Please order separately.<br />
TX6520.32<br />
PORTABLE GAS TEST KIT<br />
Includes everything necessary for fast<br />
calibration of ZERO and SPAN values of<br />
Sentro eModules.<br />
Please specify: • Type of <strong>gas</strong><br />
TROLEX LIMITED<br />
NEWBY ROAD, HAZEL GROVE, STOCKPORT,<br />
CHESHIRE SK7 5DY, UK<br />
T: +44 (0)161 483 1435<br />
E: sales@trolex.com<br />
W: trolex.com 9<br />
ISSUE B 10/08<br />
/9