series BL
series BL
series BL
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>series</strong> <strong>BL</strong><br />
S3C102E7-<strong>BL</strong><br />
Cost effective solutions combining<br />
excellent performances and effective field<br />
operations<br />
Portable<br />
Microprocessor<br />
Dry Blocks<br />
for a wide<br />
temperatures range<br />
<strong>BL</strong>-0 –30* + 125 °C<br />
<strong>BL</strong>-3 ambient + 300 °C<br />
<strong>BL</strong>-7 ambient + 700 °C<br />
* Ambient T = 20 °C<br />
The most remarkable characteristic of<br />
<strong>BL</strong> <strong>series</strong> represents also its most valuable<br />
benefit:<br />
Simplicity !<br />
In fact <strong>BL</strong> <strong>series</strong> has been designed to make<br />
easy all possible Temperature Calibration Procedures<br />
to any operator, in all types of Industries.<br />
Specific for Field Calibration of a variety of<br />
Temperature Devices, such as T/C, RTD,<br />
Thermometers, Temperature Recorders, Indicators<br />
and Switches, <strong>BL</strong> <strong>series</strong> may successfully<br />
be used in Laboratories and Workshops<br />
either for Instruments Calibration or<br />
Testing/ Commissioning purposes.<br />
As most demanding International Standards<br />
require, <strong>BL</strong> <strong>series</strong> allows to carry out the<br />
Calibration Procedures by using the Comparison<br />
Method.<br />
This method implies that both the Temperature<br />
Device under test and the Reference<br />
Temperature Sensor are exposed to the same<br />
temperature.<br />
To calculate the error of the Device under<br />
test, each measurement, relevant to each<br />
calibration point, must be compared with the<br />
corresponding measurement taken from a<br />
Reference Sensor.<br />
<strong>BL</strong> Series Dry Blocks does not use the Reference<br />
Sensor as sensing element of the Temperature<br />
PID Controller. It uses, instead, a<br />
standard commercial type of RTD or, depending<br />
the models, a thermocouple.<br />
This ensures a much longer life to the highly<br />
expensive Reference Sensor and improves the<br />
reliability and availability of both the Reference<br />
Sensor and the Dry Block.<br />
That is why it is meaningless to provide any<br />
accuracy figure to <strong>BL</strong> <strong>series</strong>. More correctly<br />
the accuracy to be considered is that of the<br />
chain that include the Reference Sensor and<br />
Temperature Calibrator.<br />
Periodic certifications are consequently<br />
stranger to <strong>BL</strong> <strong>series</strong> (which is limited to<br />
Reference Sensors only). Obviously any possible<br />
maintenance or service to <strong>BL</strong> <strong>series</strong><br />
does not require any re-certification procedure.
<strong>series</strong> <strong>BL</strong><br />
S3C102E7-<strong>BL</strong><br />
• TESTING & CALIBRATION OF:<br />
Thermocouples <br />
Thermoresistances <br />
Temperature Switches <br />
Temperature Sensors<br />
Temperature Converters<br />
Direct Temperature Instruments<br />
Glass Thermometers<br />
Any Temperature Device<br />
• TECHNICAL DATA<br />
<strong>BL</strong>-0 <strong>BL</strong>-3 <strong>BL</strong>-7<br />
Temperature Range -30(*)÷125 °C Ambient (**)÷300 °C Ambient (**)÷700 °C<br />
Temperature Stability ± 0.05 °C ± 0.05 °C ± 0.1 °C<br />
Heating Rate<br />
(Average value)<br />
15 °C/min 15 °C /min up to 700 °C<br />
Forced Cooling Rate<br />
(Average value)<br />
20 °C/min 12 °C/min 12 °C/min<br />
Switch Testing YES YES YES<br />
Dry Block material Aluminium Aluminium Bronze<br />
Dry Block Holes (mm) 5 holes ∅ 4.5-5.5-2x6.5-10.5 5 holes ∅ 6-8-10-12-16 5 holes ∅ 6-8-10-12-16<br />
Immersion Depth 125 mm 200 mm 200 mm<br />
Controller PID PID PID<br />
Set Point Resolution 0,1 °C 0,1 °C 1 °C<br />
Display 12 mm led 5 digits 12 mm led 5 digits 12 mm led 5 digits<br />
Display Resolution 0.01 °C 0.01 °C 0.1 °C<br />
Engineering Units °C °F °C °F °C °F<br />
Serial Interface RS 232 RS 232 RS 232<br />
Power supply 220/240V – 50/60 Hz 220/240V – 50/60 Hz 220/240V – 50/60 Hz<br />
Air Supply forced<br />
Cooling**<br />
-- 6 bar max 6 bar max<br />
net<br />
15<br />
12<br />
13<br />
Weight (kg) gross<br />
packed<br />
20<br />
23<br />
16<br />
19<br />
18<br />
21<br />
Dry Block<br />
39 x18 x 35<br />
39 x18 x 35<br />
39 x18 x 35<br />
Dimensions: Alu. case<br />
(wxdxh) cm Packing<br />
44 x 23 x 43<br />
56 x 37 x 59<br />
44 x 23 x 43<br />
56 x 37 x 59<br />
44 x 23 x 43<br />
56 x 37 x 59<br />
(*) Ambient T = 20 °C<br />
(**) Minimum Controlled Temperature –Ambient +10 °C<br />
• STANDARD SUPPLY<br />
The Standard Supply includes:<br />
• Basic Unit<br />
• Power cable<br />
• Temperature Switches Test Cable<br />
• Certificate of Compliance<br />
• Operating Manual<br />
• Aluminium carrying case<br />
• ORDER GUIDE<br />
<strong>BL</strong> -<br />
Basic Model<br />
0 Range –30* ÷ 125 °C<br />
3 Range Ambient ÷ 300 °C<br />
7 Range Ambient ÷ 700 °C<br />
* Ambient T = 20 °C
<strong>series</strong> <strong>BL</strong><br />
S3C102E7-<strong>BL</strong><br />
• FLEXI<strong>BL</strong>E OPERATIONS<br />
Due to the possibility of single to multiple<br />
arrangements, <strong>BL</strong> <strong>series</strong> Dry Blocks allows<br />
the ideal operating flexibility together with a<br />
large spectrum of possible operation modes.<br />
In fact the user may practice any manual<br />
conventional calibration mode or Computer<br />
Supported Calibration Procedures. Moreover<br />
the computer Operations can be driven by the<br />
combination of the Scandura Calibration and<br />
Maintenance software with other Scandura<br />
dedicated hardware (i.e. SCS-T, the<br />
Automatic Temperature Calibration Station):<br />
fully automatic calibration procedures are<br />
made possible to <strong>BL</strong> <strong>series</strong>.<br />
For <strong>BL</strong> <strong>series</strong> the concept of flexibility is<br />
extended also to any applicable Standard as<br />
well as to any Reference Sensor from any<br />
maker.<br />
The selection of such sensors shall preferably<br />
be made among the many types Scandura<br />
offers for a wide range of different<br />
applications.<br />
Also the complementary Measuring and<br />
Indicating Instruments can be chosen with no<br />
limitations according to the desired Functions,<br />
the expected Accuracy and Resolution, the<br />
Hard-copying or Computer management<br />
requirements etc.<br />
• RECOMMENDED ACCESSORIES<br />
Scandura offers a variety of complements for<br />
improved or enhanced operations and<br />
temperature devices to be used in<br />
conjunction with <strong>BL</strong> <strong>series</strong> Dry Blocks.<br />
For <strong>BL</strong>-0<br />
Reference Platinum Resistance Thermometer<br />
(RTD) mod. TRP0<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
Pt 100 @ 0 °C<br />
Working range -50 ÷ +200 °C<br />
Calibration 1/3 DIN<br />
4 wires connection<br />
Stainless Steel sheath (4.5 mm O.D.<br />
350 mm length)<br />
Connecting cables 2 m length<br />
Traceable calibration report: 5 points on<br />
the range -20 ÷ +120 °C<br />
Reference Platinum Resistance Thermometers<br />
(RTD) mod. TRP1<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
•<br />
Pt 100 @ 0 °C<br />
working range -50 ÷ +200 °C<br />
Calibration 1/3 DIN<br />
4 wires connection<br />
Stainless Steel sheath (4.5 mm O.D.<br />
350 mm length)<br />
Connecting cable 2 m length<br />
Traceable calibration report: 5 points on<br />
the range 0 ÷ 100 °C<br />
For <strong>BL</strong>-3<br />
Reference Platinum Resistance Thermometer<br />
(RTD) mod. TRP3<br />
Pt 100 @ 0 °C<br />
working range 0-400 °C<br />
Calibration 1/3 DIN<br />
4 wires connection<br />
Stainless Steel sheath (4.5 mm O.D.<br />
350 mm length)<br />
Connecting cable 2 m length<br />
Traceable calibration report: 5 points on<br />
the range 0 ÷ 300 °C<br />
For <strong>BL</strong>-7<br />
Reference Thermocouple Type “K” –<br />
Special Calibration mod. TCK7<br />
• Ungrounded junction<br />
Working range 0 ÷ 750 °C<br />
• Inconel sheath (4.5 mm O.D. 350 mm<br />
length)<br />
• Connecting cable 2 m length, glass fiber<br />
insulated, armoured<br />
• Traceable calibration report: 5 points on<br />
the range 200 ÷ 600 °C<br />
High Accuracy Indicators<br />
• RDI <strong>series</strong> with calibration certificate<br />
Reference Digital Temperature<br />
Indicators<br />
Temperature Portable Calibrators<br />
• G-40/T and G-40/R with calibration<br />
certificate<br />
The handheld Calibration Instruments<br />
• B-20 <strong>series</strong> with calibration certificate<br />
The Multi-Function Multi-Variable<br />
portable Calibrator with Storing<br />
Capabilities, Certification (Hard-copying)<br />
Facilities and Computer interface<br />
ON REQUEST Official SIT Certificate for<br />
temperature chain<br />
Reference sensor + indicator
<strong>series</strong> <strong>BL</strong><br />
S3C102E7-<strong>BL</strong><br />
• TYPICAL COMBINATIONS<br />
• SCANDURA: “Synonymous with Calibration”<br />
Scandura is a customer oriented enterprise<br />
that stands by all Instrument & Maintenance<br />
Engineers to better serve their requirements<br />
and enable their work to become more<br />
carried out more accurately and efficiently.<br />
Although nearly forty years of challenging and<br />
competitive activity all over the world have<br />
definitively given Scandura an international<br />
role, the roots and the fruits remain “Made in<br />
Italy”. A symbol of sophisticated solutions<br />
ensured by an experienced, creative, flexible<br />
and open minded team of people that is<br />
pleased to respond to our customer’s needs<br />
whatever your needs are.<br />
Dott. Ing.SCANDURA & FEM S.r.l.<br />
Via Ambrosoli 8<br />
20090 RODANO MILLEPINI – ITALY<br />
++39 02 95320021<br />
Fax ++39 02 95328231<br />
E-Mail: scandura@scandura.it<br />
www.scandura.it<br />
Printed in Italy<br />
Agent:<br />
We reserve the rights to alter at any time the technical<br />
specifications.<br />
SXY917E0-CAT