<strong>series</strong> <strong>BL</strong><br />

S3C102E7-<strong>BL</strong><br />

Cost effective solutions combining<br />

excellent performances and effective field<br />

operations<br />

Portable<br />

Microprocessor<br />

Dry Blocks<br />

for a wide<br />

temperatures range<br />

<strong>BL</strong>-0 –30* + 125 °C<br />

<strong>BL</strong>-3 ambient + 300 °C<br />

<strong>BL</strong>-7 ambient + 700 °C<br />

* Ambient T = 20 °C<br />

The most remarkable characteristic of<br />

<strong>BL</strong> <strong>series</strong> represents also its most valuable<br />

benefit:<br />

Simplicity !<br />

In fact <strong>BL</strong> <strong>series</strong> has been designed to make<br />

easy all possible Temperature Calibration Procedures<br />

to any operator, in all types of Industries.<br />

Specific for Field Calibration of a variety of<br />

Temperature Devices, such as T/C, RTD,<br />

Thermometers, Temperature Recorders, Indicators<br />

and Switches, <strong>BL</strong> <strong>series</strong> may successfully<br />

be used in Laboratories and Workshops<br />

either for Instruments Calibration or<br />

Testing/ Commissioning purposes.<br />

As most demanding International Standards<br />

require, <strong>BL</strong> <strong>series</strong> allows to carry out the<br />

Calibration Procedures by using the Comparison<br />

Method.<br />

This method implies that both the Temperature<br />

Device under test and the Reference<br />

Temperature Sensor are exposed to the same<br />

temperature.<br />

To calculate the error of the Device under<br />

test, each measurement, relevant to each<br />

calibration point, must be compared with the<br />

corresponding measurement taken from a<br />

Reference Sensor.<br />

<strong>BL</strong> Series Dry Blocks does not use the Reference<br />

Sensor as sensing element of the Temperature<br />

PID Controller. It uses, instead, a<br />

standard commercial type of RTD or, depending<br />

the models, a thermocouple.<br />

This ensures a much longer life to the highly<br />

expensive Reference Sensor and improves the<br />

reliability and availability of both the Reference<br />

Sensor and the Dry Block.<br />

That is why it is meaningless to provide any<br />

accuracy figure to <strong>BL</strong> <strong>series</strong>. More correctly<br />

the accuracy to be considered is that of the<br />

chain that include the Reference Sensor and<br />

Temperature Calibrator.<br />

Periodic certifications are consequently<br />

stranger to <strong>BL</strong> <strong>series</strong> (which is limited to<br />

Reference Sensors only). Obviously any possible<br />

maintenance or service to <strong>BL</strong> <strong>series</strong><br />

does not require any re-certification procedure.


<strong>series</strong> <strong>BL</strong><br />

S3C102E7-<strong>BL</strong><br />

• TESTING & CALIBRATION OF:<br />

Thermocouples <br />

Thermoresistances <br />

Temperature Switches <br />

Temperature Sensors<br />

Temperature Converters<br />

Direct Temperature Instruments<br />

Glass Thermometers<br />

Any Temperature Device<br />

• TECHNICAL DATA<br />

<strong>BL</strong>-0 <strong>BL</strong>-3 <strong>BL</strong>-7<br />

Temperature Range -30(*)÷125 °C Ambient (**)÷300 °C Ambient (**)÷700 °C<br />

Temperature Stability ± 0.05 °C ± 0.05 °C ± 0.1 °C<br />

Heating Rate<br />

(Average value)<br />

15 °C/min 15 °C /min up to 700 °C<br />

Forced Cooling Rate<br />

(Average value)<br />

20 °C/min 12 °C/min 12 °C/min<br />

Switch Testing YES YES YES<br />

Dry Block material Aluminium Aluminium Bronze<br />

Dry Block Holes (mm) 5 holes ∅ 4.5-5.5-2x6.5-10.5 5 holes ∅ 6-8-10-12-16 5 holes ∅ 6-8-10-12-16<br />

Immersion Depth 125 mm 200 mm 200 mm<br />

Controller PID PID PID<br />

Set Point Resolution 0,1 °C 0,1 °C 1 °C<br />

Display 12 mm led 5 digits 12 mm led 5 digits 12 mm led 5 digits<br />

Display Resolution 0.01 °C 0.01 °C 0.1 °C<br />

Engineering Units °C °F °C °F °C °F<br />

Serial Interface RS 232 RS 232 RS 232<br />

Power supply 220/240V – 50/60 Hz 220/240V – 50/60 Hz 220/240V – 50/60 Hz<br />

Air Supply forced<br />

Cooling**<br />

-- 6 bar max 6 bar max<br />

net<br />

15<br />

12<br />

13<br />

Weight (kg) gross<br />

packed<br />

20<br />

23<br />

16<br />

19<br />

18<br />

21<br />

Dry Block<br />

39 x18 x 35<br />

39 x18 x 35<br />

39 x18 x 35<br />

Dimensions: Alu. case<br />

(wxdxh) cm Packing<br />

44 x 23 x 43<br />

56 x 37 x 59<br />

44 x 23 x 43<br />

56 x 37 x 59<br />

44 x 23 x 43<br />

56 x 37 x 59<br />

(*) Ambient T = 20 °C<br />

(**) Minimum Controlled Temperature –Ambient +10 °C<br />

• STANDARD SUPPLY<br />

The Standard Supply includes:<br />

• Basic Unit<br />

• Power cable<br />

• Temperature Switches Test Cable<br />

• Certificate of Compliance<br />

• Operating Manual<br />

• Aluminium carrying case<br />

• ORDER GUIDE<br />

<strong>BL</strong> -<br />

Basic Model<br />

0 Range –30* ÷ 125 °C<br />

3 Range Ambient ÷ 300 °C<br />

7 Range Ambient ÷ 700 °C<br />

* Ambient T = 20 °C


<strong>series</strong> <strong>BL</strong><br />

S3C102E7-<strong>BL</strong><br />

• FLEXI<strong>BL</strong>E OPERATIONS<br />

Due to the possibility of single to multiple<br />

arrangements, <strong>BL</strong> <strong>series</strong> Dry Blocks allows<br />

the ideal operating flexibility together with a<br />

large spectrum of possible operation modes.<br />

In fact the user may practice any manual<br />

conventional calibration mode or Computer<br />

Supported Calibration Procedures. Moreover<br />

the computer Operations can be driven by the<br />

combination of the Scandura Calibration and<br />

Maintenance software with other Scandura<br />

dedicated hardware (i.e. SCS-T, the<br />

Automatic Temperature Calibration Station):<br />

fully automatic calibration procedures are<br />

made possible to <strong>BL</strong> <strong>series</strong>.<br />

For <strong>BL</strong> <strong>series</strong> the concept of flexibility is<br />

extended also to any applicable Standard as<br />

well as to any Reference Sensor from any<br />

maker.<br />

The selection of such sensors shall preferably<br />

be made among the many types Scandura<br />

offers for a wide range of different<br />

applications.<br />

Also the complementary Measuring and<br />

Indicating Instruments can be chosen with no<br />

limitations according to the desired Functions,<br />

the expected Accuracy and Resolution, the<br />

Hard-copying or Computer management<br />

requirements etc.<br />

• RECOMMENDED ACCESSORIES<br />

Scandura offers a variety of complements for<br />

improved or enhanced operations and<br />

temperature devices to be used in<br />

conjunction with <strong>BL</strong> <strong>series</strong> Dry Blocks.<br />

For <strong>BL</strong>-0<br />

Reference Platinum Resistance Thermometer<br />

(RTD) mod. TRP0<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Pt 100 @ 0 °C<br />

Working range -50 ÷ +200 °C<br />

Calibration 1/3 DIN<br />

4 wires connection<br />

Stainless Steel sheath (4.5 mm O.D.<br />

350 mm length)<br />

Connecting cables 2 m length<br />

Traceable calibration report: 5 points on<br />

the range -20 ÷ +120 °C<br />

Reference Platinum Resistance Thermometers<br />

(RTD) mod. TRP1<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

•<br />

Pt 100 @ 0 °C<br />

working range -50 ÷ +200 °C<br />

Calibration 1/3 DIN<br />

4 wires connection<br />

Stainless Steel sheath (4.5 mm O.D.<br />

350 mm length)<br />

Connecting cable 2 m length<br />

Traceable calibration report: 5 points on<br />

the range 0 ÷ 100 °C<br />

For <strong>BL</strong>-3<br />

Reference Platinum Resistance Thermometer<br />

(RTD) mod. TRP3<br />

Pt 100 @ 0 °C<br />

working range 0-400 °C<br />

Calibration 1/3 DIN<br />

4 wires connection<br />

Stainless Steel sheath (4.5 mm O.D.<br />

350 mm length)<br />

Connecting cable 2 m length<br />

Traceable calibration report: 5 points on<br />

the range 0 ÷ 300 °C<br />

For <strong>BL</strong>-7<br />

Reference Thermocouple Type “K” –<br />

Special Calibration mod. TCK7<br />

• Ungrounded junction<br />

Working range 0 ÷ 750 °C<br />

• Inconel sheath (4.5 mm O.D. 350 mm<br />

length)<br />

• Connecting cable 2 m length, glass fiber<br />

insulated, armoured<br />

• Traceable calibration report: 5 points on<br />

the range 200 ÷ 600 °C<br />

High Accuracy Indicators<br />

• RDI <strong>series</strong> with calibration certificate<br />

Reference Digital Temperature<br />

Indicators<br />

Temperature Portable Calibrators<br />

• G-40/T and G-40/R with calibration<br />

certificate<br />

The handheld Calibration Instruments<br />

• B-20 <strong>series</strong> with calibration certificate<br />

The Multi-Function Multi-Variable<br />

portable Calibrator with Storing<br />

Capabilities, Certification (Hard-copying)<br />

Facilities and Computer interface<br />

ON REQUEST Official SIT Certificate for<br />

temperature chain<br />

Reference sensor + indicator


<strong>series</strong> <strong>BL</strong><br />

S3C102E7-<strong>BL</strong><br />

• TYPICAL COMBINATIONS<br />

• SCANDURA: “Synonymous with Calibration”<br />

Scandura is a customer oriented enterprise<br />

that stands by all Instrument & Maintenance<br />

Engineers to better serve their requirements<br />

and enable their work to become more<br />

carried out more accurately and efficiently.<br />

Although nearly forty years of challenging and<br />

competitive activity all over the world have<br />

definitively given Scandura an international<br />

role, the roots and the fruits remain “Made in<br />

Italy”. A symbol of sophisticated solutions<br />

ensured by an experienced, creative, flexible<br />

and open minded team of people that is<br />

pleased to respond to our customer’s needs<br />

whatever your needs are.<br />

Dott. Ing.SCANDURA & FEM S.r.l.<br />

Via Ambrosoli 8<br />

20090 RODANO MILLEPINI – ITALY<br />

++39 02 95320021<br />

Fax ++39 02 95328231<br />

E-Mail: scandura@scandura.it<br />

www.scandura.it<br />

Printed in Italy<br />

Agent:<br />

We reserve the rights to alter at any time the technical<br />

specifications.<br />

SXY917E0-CAT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!