<strong>series</strong> M E PS1C701E0-<strong>MEP</strong>D<strong>MEP</strong>-D/<strong>DE</strong>:<strong>the</strong> <strong>handheld</strong><strong>pressure</strong> <strong>calibrator</strong>Internal ranges from -1 up to 400 barExternal ranges from –1 up to 700 barThe Calibration of:• Transducers • Transmitters• Manometers • Pressure Switchesenters in a new dimension<strong>MEP</strong>-D, <strong>the</strong> SCANDURA <strong>handheld</strong> <strong>pressure</strong><strong>calibrator</strong>, is <strong>the</strong> perfect solution for <strong>the</strong>calibration of every <strong>pressure</strong> device:transducers, manometers, transmitters,converters and switches.The main features of this <strong>calibrator</strong> are:• display of <strong>the</strong> reference <strong>pressure</strong>value and <strong>the</strong> related engineeringunit• maximum <strong>pressure</strong> value during <strong>the</strong>measurement process• leakage indication in a <strong>pressure</strong> circuit• current an voltage measurement• switch status indication<strong>MEP</strong>-D feeds a supply loop at 24 V d.c.Through a PDA (with a PalmOS sw) itmanages <strong>the</strong> complete calibration cycle till<strong>the</strong> printing of <strong>the</strong> reports.Alternatively to <strong>the</strong> PDA, <strong>the</strong> device can beconnected to a PC by a serial interface unit,allowing <strong>the</strong> use of every terminal emulationprogram (Hyper Terminal Microsoft TM ) ASCIIProtocol.TECHNICAL SPECIFICATION• Alphanumeric Display, 128 x 64 pixels,showing simultaneously <strong>the</strong> followingparameters:- Switch status: ON/OFF- Pressure Engineering Unit, selectableamong: bar, mbar, Pa, kPa, mmH 2 O,inH 2 O, mmHg, inHg, psi, kg/cm 2 (o<strong>the</strong>runits available on request)- Reference Pressure value- Maximum <strong>pressure</strong> value- Current: mA- Voltage: V- Leakage: <strong>pressure</strong> unit/sDimension: 56 x 38 mm• Output: 24 V d.c. nominal to feed <strong>the</strong>transmitter• Measurement of:Current: ± 24 mA,Resolution 0,001 mAUncertainty 0,03 % rdg + 0,003 % f.sPalm is a trademark of Palm. Inc.


Series M E PS1C701E0-<strong>MEP</strong>DVoltage : ± 30 V dc, Resolution 0,001 V,Uncertainty 0,03 % rdg + 0,003 % f.s.Switch status: ON/OFFLeakage: <strong>pressure</strong> unit/sPressure:2 different configurations:• <strong>MEP</strong>–D with one Internal Transducer(<strong>pressure</strong> ranges, see table 1)• <strong>MEP</strong>–<strong>DE</strong> with External Transducers(<strong>pressure</strong> ranges, see table 2)Table1PRESSURE RANGESINTERNAL TRANSDUCERS # (Pressure Port Connection: 1/8” BSP F)Model Range Resolution Uncertainty (1)GAUGE RANGES060G -60÷ 60 mbar 0.01 mbar 0.15 % (f.s.)500G -500 ÷ 500 mbar 0.1 mbar 0.04 % (f.s.)151G -900 ÷ 1500 mbar 0.1 mbar 0.04 % (f.s.)801G -1 ÷ 7 bar 1 mbar 0.04 % (f.s.)222G -1 ÷ 21 bar 1 mbar 0.04 % (f.s.)502G 0 ÷ 50 bar 10 mbar 0.05 % (f.s.)103G 0 ÷ 100 bar 10 mbar 0.05 % (f.s.)203G 0 ÷ 200 bar 10 mbar 0.1 % (f.s.)403G 0 ÷ 400 bar 100 mbar 0.1 % (f.s.)ABSOLUTE RANGE151A 0 ÷ 1500 mbar abs. 0.1 mbar 0.04 % (f.s.)251A 0 ÷ 2500 mbar abs. 0.1 mbar 0.04 % (f.s.)501A 0 ÷ 5 bar abs. 1 mbar 0.04 % (f.s.)701A 0 ÷ 7 bar abs. 1 mbar 0.04 % (f.s.)212A 0 ÷ 21 bar abs. 1 mbar 0.04 % (f.s.)# o<strong>the</strong>r <strong>pressure</strong> ranges available on requestTable 2 EXTERNAL TRANSDUCERS # (Process Connection: 1/4” BSP M)Model Range Resolution Uncertainty (1)GAUGE RANGESSP-1/1.5 -900 ÷ 1500 mbar 0.1 mbar 0.04 % (f.s.)SP-1/8 -1 ÷ 7 bar 1 mbar 0.04 % (f.s.)SP-1/22 -1 ÷ 21 bar 1 mbar 0.04 % (f.s.)SP-1/50 0 ÷ 50 bar 10 mbar 0.05 % (f.s.)SP-1/100 0 ÷ 100 bar 10 mbar 0.05 % (f.s.)SP-1/200 0 ÷ 200 bar 10 mbar 0.1 % (f.s.)SP-1/400 0 ÷ 400 bar 100 mbar 0.1 % (f.s.)SP-1/700 0 ÷ 700 bar 100 mbar 0.1 % (f.s.)ABSOLUTE RANGESSP-1/1.5A 0 ÷ 1500 mbar Abs. 0.1 mbar 0.04 % (f.s.)SP-1/2.5A 0 ÷ 2500 mbar Abs. 0.1 mbar 0.04 % (f.s.)SP-1/81A 0 ÷ 80 bar abs 10 mbar 0. 05 % (f.s.)# o<strong>the</strong>r <strong>pressure</strong> ranges available on request(1) includes non-Linearity, non- repeatability, Hysteresis,resolution, indication error and <strong>the</strong> Uncertainty of <strong>the</strong>Reference Instrument. The level of confidence of <strong>the</strong>uncertainty is close to 95 %.The methods to calculate <strong>the</strong> contribution of <strong>the</strong>se componentsare in accordance to <strong>the</strong> international rules: ISO GUM “Guideto Expression of Uncertainty in Measurement”, UNI CEI ENV13005.


Series M E PS1C701E0-<strong>MEP</strong>D• TECHNICAL DATA• Compact, Lightweight and Shock ResistantCase.• Simple front Panel with six boxed 4 mm goldplated copper sockets for signals:Input:Voltage Input (V),Current Input (mA)Contact Status: ON/OFF ( without voltage)Output:24 V dc to feed <strong>the</strong> transmitterIndications (LEDs):Charge (battery)TX (data Transmission)RX (data download)FAIL (failure)PWR (on/off)PS (on/off power supply 24 V)Commands ( push buttons)PWR/ZERO: ON/OFF ( main switch)/ZERO adjustment ( <strong>pressure</strong>)PS/EU: ON/OFF (power supply 24V)/Engineering Units Selection• Process Fluids: compatible with AISI 316.• Serial Port RS 232 for linking <strong>the</strong> Palm and<strong>the</strong> Personal Computer• Available Communication Protocols:- ASCII (Selection SCANDURA)- MODBUS (on request)• Power Supply: from four 1,2 V batteries typeAA rechargeable (Nikel Metal Hydride)• Operating Limits:- Temperature: 0 °C ÷ 50 °C- Relative Humidity: 20 ÷ 90 % noncondensing• Storage limits:- Temperature: - 20 °C ÷ 60 °C- Relative Humidity: 20 ÷ 90 % noncondensing• EM Compatibility- Reference standards for electro-magneticcompatibility: CEI EN 61326-1 (1998)- Applicable standards for method &procedure:EN 55011 (1999), EN 6100-4-2 (1995)EN 6100-4-3 (1996),EN 6100-4-4 (1995)• Dimensions (<strong>pressure</strong> connector excluded):100 x 155 x 40 mm• Weight: 480 g (version with internaltransducer)• FUNCTIONS ON BOARD TO PalmThe supply of <strong>MEP</strong>-D includes, on request, <strong>the</strong>Application Software mod. MCSW. If <strong>the</strong> Palmcomputer is supplied by Scandura, <strong>the</strong> Softwarewill be installed on board. O<strong>the</strong>rwise it will beinstalled on customer’s Palm by <strong>the</strong> user himself(<strong>the</strong> cable <strong>MEP</strong>-D/Palm is available on request).The software functions includes <strong>the</strong> followingfunctions:• Pre-configuration for <strong>the</strong> calibration ofManometers, Pressure Transmitters andPressure Switches• Selection of Languages : English, Italian,French, o<strong>the</strong>rs on request• Simultaneous Display of two measuringchannels, Pressure (Ch1) and ElectricalTransmitter Output (Ch2), (V, mA or ON/OFFstatus of Pressure Switch)• Display of a single channel when configured as“Digital Manometer”• Trend Graphic Display of Pressure withAutomatic indication of min/max values• Heading of Test Reports: Display and Editing• Display of Test Reports• Engineering Units Selection• Storage, virtually unlimited of any ProcessInstrument Tag & Test Report. Each reportcarries 40 calibration points max distributedbetween “as found/as left” and “up/down”• Print out and of <strong>the</strong> Calibration Reports directlyfrom <strong>the</strong> Palm via Infrared or Serial Port.• E-mail transmission of any Test Report viaInfrared port and Mobile Phone provided withModem.• Full data Back-up on “SD” Card and/or onPersonal Computer• <strong>MEP</strong>-Report, <strong>the</strong> software program todownload <strong>the</strong> calibration data from Palm toPC to print <strong>the</strong> calibration certificates directlyfrom <strong>the</strong> PC.• COMPATIBLE Palm COMPUTERSThe customer may decide to limit <strong>the</strong> purchaseto <strong>the</strong> sole <strong>MEP</strong>-D using at his discretion anyof <strong>the</strong> following models:Palm ZIRE 71Palm M515Palm M505Palm M500Palm M130Palm M125Operative Systems already verified: from PalmOS 3.5.2 to Palm OS 5.The compatibility may be extended to allo<strong>the</strong>rs Palm computers using Palm OSoperative system. In <strong>the</strong>se cases Scandura willcarry out ex-factory <strong>the</strong> relevant operativetests.


Series M E PS1C701E0-<strong>MEP</strong>D• STANDARD SUPPLY• <strong>MEP</strong>-D unit• Electric kit (code 241067)• Set of rechargeable batteriestype AA Ni-Mh• Battery Charger (mod. EC 100)• Soft bag with shoulder strap (mod.BM001)• Conformity Report• Calibration work test report• Operating Manual• OR<strong>DE</strong>R GUI<strong>DE</strong>• <strong>MEP</strong>-D –XXXXSelect one range, code in table 1 BA-12 Pressure Generator up to 7 bar with fineadjustment within ± 0,05 mbarBA-42 Vacuum Generator up to - 0,85 bar withfine adjustment within ± 0,05 mbarElectric KitProduct Code 241067N.4 silivolt cablesN.2 crocodilesPneumatic Pressure Kit(up to 7 bar)Product Code 241078N.1 1/8” BSP M x Plug-in female connectorN.1 Plug-in male connector x tube O.D. 6 mmN.1 “T” brass joint tube O.D. 6 mmN.1 “Cross” joint tube O.D. 6 mmmt.1.5 Neutral Rilsan tube hose 6x4 <strong>MEP</strong>-<strong>DE</strong>-XXXXX–XXXXXSelect one or more ranges, code in table 2Communication ProtocolA ASCII CommunicationExample:<strong>MEP</strong>-D-500G-A<strong>MEP</strong>-<strong>DE</strong>-A + SP-1/7• ACCESSORIES ON REQUEST Pneumatic kit Calibration Certificate (Italian SIT) MCSW Software + <strong>MEP</strong> Report + Cable<strong>MEP</strong>- D/Palm TM <strong>MEP</strong>-D/ Palm cable <strong>MEP</strong>-D/PC Cable High speed battery charger (mod. PS 500) PDA Palm Handheld Hydraulic Pressure Generator, model:GHM: range 0 ÷ 300 barGHM-H: range 0 ÷ 400 barGHH: range: 0 ÷ 700 barPneumatic Pressure Kit(up to 21 bar)Product Code 241068N.1 1/8” BSP M x Plug-in female connectorN.1 Plug-in male connector x tube O.D. 6 mmN.1 “T” brass joint tube O.D. 6 mmN.1 “Cross” joint tube O.D. 6 mmmt.1.5 Neutral Rilsan tube hose 6x4N.1 adapter tube O.D. 6 mm x 1/8 BSP FN.1 adapter tube O.D. 6 mm x 1/4 BSP FN.1 adapter tube O.D. 6 mm x 1/8 BSP MN.1 adapter tube O.D. 6 mm x 1/4 BSP MPneumatic/hydraulic Pressure Kit(High <strong>pressure</strong>)Product Code 241069N.1 male connector 1/8” BSP x quick testmt.1 high <strong>pressure</strong> tube with quick testN.1 adapter quick test x ¼” BSPN.1 adapter NF4 ¼” BSP male X ¼” NPT FN.1 adapter NF2 ¼” BSP male X ½” NPT FN.1 adapter BF2 ¼” BSP male X ½” BSP FN.1 adapter NM4 ¼” BSP male X ¼” NPT MN.1 adapter NM2 ¼” BSP male X ½” NPT M• SCANDURA: Synonymous with CalibrationScandura is a customer’s oriented enterprise thatstupports all Instrument & Maintenance Engineersto better serve <strong>the</strong>ir requirements and making<strong>the</strong>ir job more accurate and valuable.Although nearly forty years of challenging andcompetitive activity all over <strong>the</strong> world haveDott. Ing.SCANDURA & FEM S.r.l.Via Ambrosoli 820090 RODANO MILLEPINI – ITALY++39 02 95320021Fax ++39 02 95328231E-Mail: scandura@scandura.itwww.scandura.itPrinted in Italydefinitively given Scandura an international role,<strong>the</strong> roots and <strong>the</strong> fruits remain “Made in Italy”. Asymbol of sophisticated solutions ensured by anexperienced, creative, flexible and open mindedteam of people that is pleased to respond tocustomer’s needs whatever <strong>the</strong>ir needs are.Agente:We reserve <strong>the</strong> rights to alter at any time <strong>the</strong> technicalspecificationsSXY917E0-CAT