XI. MOBILE-HOME PARK: (cont’d)<br />
5. Feeder conductors from the load-side <strong>of</strong> the park’s service disconnectingmeans<br />
which feed mobile-home spaces shall be permitted to use type “USE”<br />
direct burial conductors without conduit, but only when installed at a minimum<br />
depth <strong>of</strong> thirty-six-inches (36") below finished grade in accordance with<br />
Drawing US-l. Conductors installed in approved electrical conduit, as listed in<br />
ITEM 2, shall be permitted to be buried at a minimum depth <strong>of</strong> eighteen-inches<br />
(l8") below finished grade in accordance with Drawing US-2.<br />
6. Each mobile-home space’s meter shall be installed on an approved metal<br />
meter pedestal set in concrete in accordance with Drawing US-6 and in<br />
compliance with the NEC, State Code and MHC. Each pedestal shall be durably<br />
and legibly marked, displaying the space number.<br />
7. Underground taps/joints/splices are prohibited.<br />
EXCEPTION: Damaged existing-park-feeders may be<br />
repaired by an approved method.<br />
8. Mobile-home parks, which are being remodeled, shall be required, for the<br />
portion being remodeled, to comply with the same requirements as new parks.<br />
9. All recreational vehicle parks will be installed with underground wiring<br />
methods per NEC Article #551<br />