WIRING DEVICES<br />
PRESENCE DETECTORS<br />
Surface mounted back box<br />
Product code Description Pack qty<br />
MTN550619 Surface mounted back box 1<br />
MTN550619<br />
Flush mounted back box<br />
Product code Description Pack qty<br />
ALB71322 Flush mounted back box 1<br />
ALB71322<br />
Side controller plus, complete unit<br />
MTN51290319<br />
IR remote control, distance 2010<br />
Product code Description Pack qty<br />
MTN51290319 Side controller plus, complete unit 1<br />
Functions:<br />
• Line control via one PL-output.<br />
• Triggering master devices (right<br />
buttons).<br />
• Activating the 24h staircase timer (left<br />
buttons).<br />
Nominal voltage:<br />
AC 220/230V, 50/60Hz.<br />
Output:<br />
1 x PlusLink.<br />
Neutral connector:<br />
Not required (2 conductor system)<br />
Wire range:<br />
Max. 2x2.5mm².<br />
Accessories:<br />
PlusLink expander CCTDT5130.<br />
Product code Description Pack qty<br />
MTN570222 IR remote control, distance 2010 1<br />
• Technical notes:<br />
For triggering all Argus<br />
presence masters.<br />
The device has one<br />
PL-output. The control<br />
function via PL requires<br />
a separate core in<br />
the installation to the<br />
receiving master and<br />
secondary devices.<br />
With screw terminals.<br />
With claw and screw<br />
fixing.transformers,<br />
flourescent lamps.<br />
• Technical notes:<br />
10 channel IR remote<br />
control.<br />
MTN570222<br />
PlusLink expander<br />
CCTDT5130<br />
Battery:<br />
2 microcells (IEC LR 03, AAA).<br />
Range:<br />
Up to 20m.<br />
Contents:<br />
Without battery.<br />
Product code Description Pack qty<br />
CCTDT5130 PlusLink expander 1<br />
Nominal voltage:<br />
AC 220/230V.<br />
Neutral connector:<br />
Required (3 conductor system).<br />
Wire range:<br />
Max. 4mm².<br />
Device width:<br />
1HP=18mm.<br />
• Technical notes:<br />
The PlusLink extension<br />
needs to be integrated<br />
into one or more<br />
PL-lines if there are<br />
protected by at least<br />
two circuit breakers.<br />
If a circuit breaker is<br />
triggered in the event<br />
of maintenance work<br />
or a fault, then the<br />
PlusLink expansion will<br />
disconnect the PlusLink<br />
line automatically as<br />
well. This is necessary<br />
because the PlusLink<br />
line would otherwise<br />
continue to be live<br />
via the other circuit<br />
breakers. With screw<br />
terminals. Suitable for<br />
installation on DIN rails<br />
TH35 according to EN<br />
60715.<br />