Easy9 & Resi9<br />
Affordable circuit protection<br />
you can depend on<br />
Compliant<br />
metal consumer unit<br />
BS 7671:2008<br />
Amendment 3 (2015)
Schneider Electric is a global specialist<br />
in energy management. Established as a<br />
circuit breaker designer and manufacturer<br />
in France since 1920, Schneider Electric<br />
are the worldwide leader of electrical<br />
protection technologies, present in more<br />
than 100 countries.<br />
Domestic Circuit Protection BS7671 Amendment 3<br />
Regulation 421.1.201 – What is it and when does it<br />
come into force?<br />
> From January 2015 Amendment No. 3 to BS7671 IET Wiring Regulations prescribes<br />
that within domestic (household) premises, consumer units and similar switchgear<br />
assemblies shall have their enclosures manufactured from non-combustible material,<br />
or be enclosed in a cabinet or enclosure constructed of non-combustible material and<br />
comply with product standard BS EN 61439-3.<br />
> Although regulation 421.1.201 will appear in BS7671 from January 2015, it is<br />
expected that the implementation date for this regulation with be 1st January<br />
2016, however this does not preclude compliance particularly in terms of design and<br />
specification prior to this date.<br />
What is the intention behind this change to BS7671?<br />
> As far as it is reasonably practical, to contain any fire within the<br />
enclosure and minimise flames from escaping, caused mainly as a<br />
result of poorly installed connections.<br />
What is a non-combustible enclosure?<br />
> At the time of this publication it is expected that regulation 421.1.201 will advise<br />
that an example of a non combustible materials is a ferrous metal e.g. steel. Therefore<br />
a non combustible enclosure includes base, cover, door and any components e.g.<br />
hinges necessary to contain the fire. Blanks and devices are contained within the non<br />
combustible enclosure.<br />
1
Easy9<br />
Affordable circuit protection<br />
you can depend on<br />
Introduction<br />
A complete range of modular devices...................................................................................... p.3<br />
New Easy9 circuit protection provides long-lasting protection.................................................. p.5<br />
Product information<br />
Metal enclosures..................................................................................................................... p.9<br />
Switch-disconnectors............................................................................................................ p.10<br />
RCCB residual current circuit breakers.................................................................................. p.11<br />
Miniature circuit breaker ........................................................................................................ p.12<br />
RCBO residual current devices.............................................................................................. p.13<br />
Product selector.................................................................................................................... p.14<br />
Technical<br />
Technical information ............................................................................................................ p.17<br />
Resi9<br />
The complete residential<br />
circuit protection offer<br />
Introduction<br />
Resi9 Consumer Units........................................................................................................... p.28<br />
Features & benefits................................................................................................................ p.29<br />
Resi9 overview...................................................................................................................... p.30<br />
Resi9 overview diagram......................................................................................................... p.31<br />
Product information<br />
Resi9...................................................................................................................................... p33<br />
Switch-disconnector.............................................................................................................. p.34<br />
RCCB Residual Current Circuit Breaker................................................................................. p.35<br />
RCBO Residual Current Device............................................................................................. p.36<br />
Miniature Circuit Breaker......................................................................................................... p37<br />
Terminal Block....................................................................................................................... p.38<br />
Quick Selector<br />
Select consumer unit............................................................................................................. p.40<br />
Select devices....................................................................................................................... p.41<br />
Technical Guide<br />
Resi9 - metal unit dimensions................................................................................................ p.43<br />
2
Easy9<br />
Affordable circuit protection<br />
you can depend on<br />
A complete range of modular<br />
devices<br />
Just what you need from circuit protection<br />
We work closely with electricians worldwide to help bring safe<br />
electricity to homes and buildings around the globe. Now you can<br />
take pride in delivering to your customers the enhanced safety<br />
and peace of mind they deserve.<br />
3
“I would recommend Easy9<br />
to anyone”<br />
New, robust circuit protection<br />
from a brand you trust<br />
The new Easy9 range better supports your<br />
business as an electrician, helping you to be<br />
more effective through:<br />
> A high-quality, user-friendly design<br />
> Availability when and where you need it<br />
> Reliability you can count on<br />
4
Easy9<br />
Affordable circuit protection<br />
you can depend on<br />
New Easy9 circuit protection<br />
provides long-lasting protection<br />
Easy9 brings you the quality, peace of mind, and reliability of<br />
a high-end device at a mid-range price. Thanks to consistent<br />
design and high manufacturing standards, Easy9 is a durable<br />
range you can be proud to install.<br />
> Guaranteed compliance to product standards<br />
> Certification by independent authorities<br />
Since<br />
1920<br />
Leader in electrical<br />
switchgear<br />
5
Quality<br />
- 100% designed and manufactured by Schneider Electric<br />
- All sites with ISO 9000 certification<br />
- Brand selected everywhere for industry, hospitals and airports<br />
Availability<br />
- Always available at your distributor<br />
- Complete coverage of protection features<br />
- Large assortment of ratings<br />
Customer satisfaction<br />
- Highly reliable and safe circuit protection<br />
- Dependable power supply<br />
Safety<br />
- Protection from electric shocks, overloads and short circuits<br />
- Compliance to standards<br />
Time saving<br />
- Consistent design and connection features<br />
- One-stop shopping for all parts<br />
- Proven robustness to withstand wear and tear<br />
6
Easy9<br />
Easy 9 at a glance<br />
Affordable circuit protection<br />
you can depend on<br />
Schneider Electric warranty<br />
Comprehensive range<br />
Full compliance<br />
with international<br />
IEC standards 3rd<br />
party certification<br />
Installer-friendly wiring<br />
with only 1 screwdriver<br />
7
Class II front face<br />
Full range coherence<br />
Compliant<br />
metal consumer unit<br />
BS 7671:2008<br />
Amendment 3 (2015)<br />
<br />
Clear and visible<br />
production information.<br />
Whatever the toggle<br />
position<br />
Full trip indication on<br />
the front panel by<br />
position of handle<br />
On-Off engraved<br />
Neutral terminal<br />
identification engraved<br />
8
Easy9<br />
Metal enclosures<br />
BS7671 Amendment 3 Compliant<br />
Description<br />
The surface mounting enclosure consists of:<br />
■■<br />
Metal surface mounting enclosure with:<br />
■■<br />
Multiple cable entry points and rear knock out slots<br />
■■<br />
Secure fixed DIN rail<br />
■■<br />
Earth terminal block and a neutral terminal blocks fitted as standard<br />
■■<br />
Secure busbar shield<br />
■■<br />
Standard consumer units up to 20 usable ways<br />
■■<br />
Earthed cover<br />
■■<br />
Enclosure colour: White RAL 9003.<br />
Compliant<br />
metal consumer unit<br />
BS 7671:2008<br />
Amendment 3 (2015)<br />
<br />
Consumer Unit<br />
Reference Description No. Usable Ways<br />
EZ92MCUL EZ9 2 Way Metal CU 2<br />
EZ94MCUL EZ9 4 Way Metal CU 4<br />
EZ96MCUL EZ9 6 Way Metal CU 6<br />
EZ98MCUL EZ9 8 Way Metal CU 8<br />
EZ912MCUL EZ9 12 Way Metal CU 12<br />
EZ916MCUL EZ9 16 Way Metal CU 16<br />
EZ920MCUL EZ9 20 Way Metal CU 20<br />
Consumer unit with switch/RCDs fitted<br />
Reference Description No. Usable Ways<br />
EZ9R4R4MCUL EZ9 4+4W 100A Sw, 63A RCCBx2 Metal 4+4 dual RCCB<br />
EZ9R6R6MCUL EZ9 6+6W 100A Sw, 63A RCCBx2 Metal 6+6 dual RCCB<br />
EZ9R6R6DMCUL EZ9 6+6W 100A Sw, 80A RCCBx2 Metal 6+6 dual RCCB<br />
EZ9R8R8DMCUL EZ9 8+8W 100A Sw, 80A RCCBx2 Metal 8+8 dual RCCB<br />
EZ9S2R5R5DMCUL EZ9 2+5+5 100A Sw, 80A RCCBx2 Metal cw 2 unprotected ways 2,5,5 dual RCCB<br />
EZ9S2R7R7DMCUL EZ9 2+7+7 100A Sw, 80A RCCBx2 Metal cw 2 unprotected ways 2,7,7 dual RCCB<br />
Consumer unit with switch/RCDs fitted<br />
Reference Description No. Usable Ways<br />
Flexible Split Consumer Unit Including Incomers<br />
EZ9FS12MCUL<br />
EZ9 12 Way FS 100A Sw, 80A RCCBx2 Metal<br />
up to 4 unprotected ways with max splits of 4/7/7<br />
EZ9FS16MCUL<br />
EZ9 16 Way FS 100A Sw, 80A RCCBx2 Metal<br />
up to 4 unprotected ways with max splits of 4/9/9<br />
Populated consumer unit with switch/RCDs/MCBs fitted<br />
12 way flex split<br />
16 way flex split<br />
Reference Description No. Usable Ways<br />
EZ9R6R6MREL EZ9 6+6 Kitbox cw 8 MCB Metal 6+6 dual RCCB<br />
EZ9S2R5R5DMREL EZ9 2+5+5 Kitbox cw 8 MCB Metal Metal cw 2 unprotected ways 2,5,5 dual RCCB<br />
Garage consumer unit<br />
Reference Description No. Usable Ways<br />
EZ9GARAGE63L EZ9 garage unit cw 63A RCCB and 6 & 16A mcbs 2<br />
9
Easy9<br />
Switch-disconnectors<br />
Functions<br />
The switch-disconnectors are used for:<br />
■■<br />
Control (opening and closing of circuits under load).<br />
■■<br />
Disconnection of on-load electrical circuits already protected against overloads<br />
and short-circuits.<br />
2P<br />
Easy9 control switches<br />
Rating (Ie)<br />
63 A EZ9S16263<br />
100 A EZ9S16291<br />
Voltage rating (Ue)<br />
400 V, 50/60 Hz<br />
Width in 9-mm modules 4<br />
Certified compliant BSEN60947-3<br />
Connection<br />
6.5 mm<br />
PZ2<br />
Rigid copper cables<br />
y 50 mm 2<br />
Flexible copper cables<br />
y 35 mm 2<br />
Tightening torque: 3.5 Nm<br />
Tightening torque: 3.5 Nm<br />
20 mm<br />
10
Easy9<br />
RCCB residual current circuit<br />
breakers<br />
Functions<br />
■■<br />
Tripping in case of leakage current only.<br />
■■<br />
One RCCB protects several circuits when fitted upstream of a group of<br />
circuit breakers.<br />
2P<br />
Residual current circuit breakers AC<br />
Rating (In)<br />
30 mA<br />
63 A EZ9R33263<br />
80 A EZ9R33280<br />
Voltage rating (Ue)<br />
127 - 230 V, 50/60 Hz<br />
Width in 9-mm modules 4<br />
Certified compliant BSEN61008-1<br />
Additional feature<br />
Endurance (O-C) Electrical 2000 cycles<br />
Mechanical<br />
5000 cycles<br />
Conditional rated short With fuse<br />
3000 A<br />
circuit current (Inc/IDc) With Easy9 MCB<br />
3000 A<br />
Operating temperature<br />
-5°C to +60°C<br />
Storage temperature<br />
-40°C to +85°C<br />
Electrical feeding<br />
By the top and the bottom<br />
Connection<br />
DB406037<br />
6.5 mm<br />
PZ2<br />
Rigid copper cables<br />
1 to 35 mm 2 Tightening torque: 3.5 Nm<br />
Flexible copper cables<br />
1 to 25 mm 2 Tightening torque: 3.5 Nm<br />
16 mm<br />
11
Easy9<br />
Miniature circuit breaker<br />
1P<br />
Circuit breakers<br />
Rating (In) Curve B Curve C<br />
3 A EZ9F16103 -<br />
6 A EZ9F16106 EZ9F66106<br />
10 A EZ9F16110 EZ9F66110<br />
16 A EZ9F16116 EZ9F66116<br />
20 A EZ9F16120 EZ9F66120<br />
25 A EZ9F16125 -<br />
32 A EZ9F16132 EZ9F66132<br />
40 A EZ9F16140 EZ9F66140<br />
50 A EZ9F16150 EZ9F66150<br />
Width in 9-mm modules 2<br />
Certified compliant BS EN 60898-1<br />
Additional feature<br />
According to EN 60898-1<br />
Breaking capacity (Icn)<br />
Ph/N 230 V AC 6000 A<br />
Additional characteristics<br />
Endurance (O-C) Electrical 4,000 cycles<br />
Mechanical<br />
10,000 cycles<br />
Operating temperature<br />
-5°C to +60°C<br />
Storage temperature<br />
-40°C to +85°C<br />
Connection<br />
6.5 mm<br />
PZ2<br />
Rigid copper cables<br />
3 to 25 A 1 to 25 mm 2 Tightening torque: 2 Nm<br />
32 to 50 A 1 to 35 mm 2 Tightening torque: 3.5 Nm<br />
16 mm<br />
Flexible copper cables<br />
3 to 25 A 1 to 16 mm 2 Tightening torque: 2 Nm<br />
32 to 50 A 1 to 25 mm 2 Tightening torque: 3.5 Nm<br />
12
Easy9<br />
RCBO residual current devices<br />
Functions<br />
■■<br />
Protection from short-circuits.<br />
■■<br />
Protection of cable from overloads.<br />
■■<br />
Protection of persons from electric shocks by direct contact (30 mA sensitivity)<br />
■■<br />
Can be fitted instead of a miniature circuit breaker for complete protection of one<br />
circuit.<br />
The Earth Reference Cable "FE": enables RCD to protect users from electric shocks,<br />
even in case of supply neutral loss, neutral conductor breakage or supply voltage<br />
drop (FE= Functional Earth).<br />
1P+N<br />
Easy9 RCBO type A 30 mA<br />
Rating (In)<br />
B curve<br />
6 A EZ9D16806<br />
10 A EZ9D16810<br />
16 A EZ9D16816<br />
20 A EZ9D16820<br />
25 A EZ9D16825<br />
32 A EZ9D16832<br />
40 A EZ9D16840<br />
50 A EZ9D16850<br />
Voltage rating (Ue)<br />
230 V AC, 50 Hz<br />
Width in 9-mm modules 2<br />
Certified compliant BS EN 61009-1<br />
Connection<br />
5.5 mm<br />
PZ2<br />
Rigid copper cables<br />
L in 1 to 25 mm 2 Tightening torque: 2 Nm<br />
L and N out 1 to 16 mm 2 Tightening torque: 2 Nm<br />
14 mm<br />
16 mm<br />
Flexible copper cables<br />
L in 1 to 16 mm 2 Tightening torque: 2 Nm<br />
L and N out 1 to 10 mm 2 Tightening torque: 2 Nm<br />
13
Easy9<br />
Product selector<br />
Consumer Unit<br />
Reference Description No Ways<br />
EZ92MCUL EZ9 2 Way Metal CU 2<br />
EZ94MCUL EZ9 4 Way Metal CU 4<br />
EZ96MCUL EZ9 6 Way Metal CU 6<br />
EZ98MCUL EZ9 8 Way Metal CU 8<br />
EZ912MCUL EZ9 12 Way Metal CU 12<br />
EZ916MCUL EZ9 16 Way Metal CU 16<br />
EZ920MCUL EZ9 20 Way Metal CU 20<br />
Incoming Devices<br />
Reference Device Rating Description<br />
EZ9S16263 Switch 63A EZ9 Switch Disconnector 2P 63A 400V<br />
EZ9S16291 Switch 100A EZ9 Switch Disconnector 2P 100A 400V<br />
EZ9R33263 RCCB 63A, 30mA EZ9 RCCB 2P 63A 30mA AC-type 230V<br />
Residual Current Circuit Breaker<br />
EZ9R33280 RCCB 80A, 30mA EZ9 RCCB 2P 80A 30mA AC-type 230V<br />
Residual Current Circuit Breaker<br />
For split load applications select a split load kit<br />
Reference Description Rating<br />
EZ963R30KIT2 RCCB and cables 63A 30mA<br />
EZ980R30KIT2 RCCB and cables 80A 30mA<br />
OR<br />
Select consumer units with switch/RCD’s fitted<br />
Reference Description Total ways Un/P ways RCD1 ways RCD2 ways<br />
EZ9R4R4MCUL EZ9 4+4W 100A Sw, 63A RCCBx2 Metal 8 4 4<br />
EZ9R6R6MCUL EZ9 6+6W 100A Sw, 63A RCCBx2 Metal 12 6 6<br />
EZ9R6R6DMCUL EZ9 6+6W 100A Sw, 80A RCCBx2 Metal 12 6 6<br />
EZ9R8R8DMCUL EZ9 8+8W 100A Sw, 80A RCCBx2 Metal 16 8 8<br />
EZ9S2R5R5DMCUL EZ9 2+5+5 100A Sw, 80A RCCBx2 Metal 12 2 5 5<br />
EZ9S2R7R7DMCUL EZ9 2+7+7 100A Sw, 80A RCCBx2 Metal 16 2 7 7<br />
Flexible Split Consumer Unit Including Incomers Total ways Max Un/P ways Max RCD1 ways Max RCD2 ways<br />
EZ9FS12MCUL EZ9 12 Way FS 100A Sw, 80A RCCBx2 Metal 12 4 7 7<br />
EZ9FS16MCUL EZ9 16 Way FS 100A Sw, 80A RCCBx2 Metal 16 4 9 9<br />
Amendment 3 metal populated consumer unit with switch/RCDs/MCBs fitted Total ways Max Un/P ways Max RCD1 ways Max RCD2 ways<br />
EZ9R6R6MREL EZ9 6+6 Kitbox cw 8 MCB Metal 12 6 6<br />
EZ9S2R5R5DMREL EZ9 2+5+5 Kitbox cw 8 MCB Metal 12 2 5 5<br />
EZ9GARAGE63L Garage unit cw 63A RCCB and 6 & 16A mcbs 2 - 2 -<br />
14
Easy9<br />
Product selector<br />
Select devices and accessories<br />
Select outgoing devices or accessories<br />
SP 6kA MCBs (B curve)<br />
Reference Description Current Rating<br />
EZ9F16103 MCB (B curve) 3A<br />
EZ9F16106 MCB (B curve) 6A<br />
EZ9F16110 MCB (B curve) 10A<br />
EZ9F16116 MCB (B curve) 16A<br />
EZ9F16120 MCB (B curve) 20A<br />
EZ9F16125 MCB (B curve) 25A<br />
EZ9F16132 MCB (B curve) 32A<br />
EZ9F16140 MCB (B curve) 40A<br />
EZ9F16150 MCB (B curve) 50A<br />
SP 6kA MCBs (C curve)<br />
Reference Description Current Rating<br />
EZ9F66106 MCB (C curve) 6A<br />
EZ9F66110 MCB (C curve) 10A<br />
EZ9F66116 MCB (C curve) 16A<br />
EZ9F66120 MCB (C curve) 20A<br />
EZ9F66132 MCB (C curve) 32A<br />
EZ9F66140 MCB (C curve) 40A<br />
EZ9F66150 MCB (C curve) 50A<br />
SP 6kA 1 module RCBO (B curve)<br />
Reference Description Current rating<br />
EZ9D16806 RCBO 30mA 1 Module 1P&N 6A<br />
EZ9D16810 RCBO 30mA 1 Module 1P&N 10A<br />
EZ9D16816 RCBO 30mA 1 Module 1P&N 16A<br />
EZ9D16820 RCBO 30mA 1 Module 1P&N 20A<br />
EZ9D16825 RCBO 30mA 1 Module 1P&N 25A<br />
EZ9D16832 RCBO 30mA 1 Module 1P&N 32A<br />
EZ9D16840 RCBO 30mA 1 Module 1P&N 40A<br />
EZ9D16850 RCBO 30mA 1 Module 1P&N 50A<br />
Accessories<br />
Reference<br />
EZ9LKITL<br />
EZ9EARTHKIT<br />
EZ916BKIT<br />
SEDNBP3<br />
Description<br />
Door lock kit (for amendment 3 metal enclosure only)<br />
Additional earth terminals for clean earth or high integrity earthing<br />
Replacement/spare main busbar<br />
3 module blanking plate<br />
15
Easy9<br />
Technical<br />
information<br />
16
Easy9<br />
Technical information<br />
Metal Units<br />
Ref No. Type No Ways Height (mm) Width (mm) Depth (mm)<br />
EZ92MCUL Standard 2 247 186 100<br />
EZ94MCUL Standard 4 247 222 100<br />
EZ96MCUL Standard 6 247 258 100<br />
EZ98MCUL Standard 8 247 294 100<br />
EZ912MCUL Standard 12 247 366 100<br />
EZ916MCUL Standard 16 247 438 100<br />
EZ920MCUL Standard 20 247 510 100<br />
EZ9R4R4MCUL Split 8 247 366 100<br />
EZ9R6R6MCUL Split 12 247 438 100<br />
EZ9R6R6DMCUL Split 12 247 438 100<br />
EZ9R8R8DMCUL Split 16 247 510 100<br />
EZ9S2R5R5DMCUL Multiple 12 247 438 100<br />
EZ9S2R7R7DMCUL Multiple 16 247 510 100<br />
EZ9FS12MCUL Flex Split 12 247 438 100<br />
EZ9FS16MCUL Flex Split 16 247 510 100<br />
EZ9R6R6MREL Multiple 12 247 438 100<br />
EZ9S2R5R5DMREL Multiple 12 247 438 100<br />
EZ9GARAGE63L garage 2 247 186 100<br />
G<br />
86<br />
G<br />
G<br />
F<br />
D<br />
F<br />
29 41<br />
20 B<br />
20<br />
A<br />
Note: Incoming and outgoing devices must be<br />
selected separately from the devices section -<br />
only applies to EZ9**MCUL<br />
Incoming devices available<br />
• Switch disconnector 63A & 100A<br />
• RCCB’s 63A/30mA 80A/30mA<br />
Max. busbar splits - for split load<br />
8 way 2+4 to 4+2<br />
12 way 4+6 to 6+4<br />
16 way 6+8 to 8+6<br />
F<br />
D<br />
G<br />
E<br />
80<br />
G<br />
30<br />
21<br />
36<br />
200<br />
No. Of knockouts<br />
Dimensions (mm)<br />
25 x<br />
90mm<br />
32mm 25mm 20mm 18mm<br />
Ref No. A B D E F G<br />
EZ92MCUL 180 140 - 2* - 2 -<br />
EZ94MCUL 217 176 1 1 1 2 -<br />
EZ96MCUL 253 212 1 1 1 3 -<br />
EZ98MCUL 289 248 1 1 2 3 -<br />
EZ912MCUL 361 320 2 1 3 4 -<br />
EZ916MCUL 433 392 2 1 3 5 -<br />
EZ920MCUL 505 464 2 1 3 5 1<br />
EZ9S2R5R5DMREL 433 392 2 1 3 5 -<br />
EZ9S2R5R5DMCUL 433 392 2 1 3 5 -<br />
EZ9S2R7R7DMCUL 505 464 2 1 3 5 1<br />
EZ9R8R8DMCUL 505 464 2 1 3 5 1<br />
EZ9R5R5DMCUL 433 392 2 1 3 5 -<br />
EZ9R6R6DMCUL 433 392 2 1 3 5 -<br />
EZ9R6R6MCUL 433 392 2 1 3 5 -<br />
EZ9R6R6MREL 433 392 2 1 3 5 -<br />
EZ9R4R4MCUL 361 320 2 1 3 4 -<br />
EZ9FS12MCUL 433 392 2 1 3 5 -<br />
EZ9FS16MCUL 505 464 2 1 3 5 1<br />
EZ9GARAGE63L 180 140 - 2* - 2 -<br />
* 2W Version only, 1 x 32mm K/O in upper wall, 1 x K/O in back of box.<br />
Technical data<br />
Max. busbar current (A) 100A<br />
Max. operating voltage 230/240V @ 50Hz<br />
Max. cable capacity 25 mm2 (earth and neutral bars)<br />
Certification BS EN 61439-3<br />
17
Easy9<br />
Switch-disconnectors<br />
Position contact<br />
indication<br />
Suitable for isolation<br />
according to<br />
BSEN 60947-3 standard<br />
Manual control on front<br />
face by O-I lever<br />
Characteristics<br />
Main characteristics<br />
Operating category<br />
AC-22 A<br />
Permissible rated short-time withstand current (Icw) 12 Ie, 1 second<br />
Conditional rated short-circuit current (Inc) 5000 A<br />
Rated short-circuit closing current (Icm)<br />
15 Ie<br />
Additional characteristics<br />
Degree of protection<br />
(IEC 60529)<br />
Device only<br />
IP20<br />
Endurance (O-C) Mechanical 40 -100 A 8500 cycles<br />
Electrical 40-100 A 1500 cycles<br />
Operating temperature<br />
-5°C to +55°C<br />
Storage temperature<br />
-5°C to +70°C<br />
Tropicalisation (IEC 60068-1) Treatment 2<br />
(relative humidity 95 % to 55°C)<br />
Dimensions (mm)<br />
2P<br />
36<br />
5.5<br />
73<br />
61<br />
45<br />
82<br />
45<br />
3<br />
Weight (g)<br />
Type<br />
Easy9 switch-disconnector<br />
2P 175<br />
18
Easy9<br />
RCCB residual current circuit<br />
breakers<br />
Positive contact<br />
indication.<br />
Fault tripping indication<br />
on the front panel by<br />
the position of the<br />
handle (O - I engraved)<br />
Characteristics<br />
Main characteristics<br />
Rated impulse withstand voltage (Uimp)<br />
According to IEC 61008-1<br />
Making and breaking capacity (Im/IDm)<br />
4 kV<br />
500 A<br />
Additional characteristics<br />
Degree of protection<br />
(IEC 60529)<br />
Hazardous substances<br />
Tropicalisation (IEC 60068-1)<br />
Device only<br />
IP20<br />
RoHS 2003 compliant<br />
Treatment 2 (relative humidity 95 % to 55°C)<br />
Dimensions (mm)<br />
36<br />
2P<br />
5.5<br />
68<br />
61<br />
45<br />
82<br />
45<br />
7<br />
62<br />
Weight (g)<br />
Type<br />
Easy9 RCCB<br />
2P 195<br />
19
Easy9<br />
Miniature circuit breaker<br />
6 kA<br />
Easy9 circuit breakers combine the following<br />
functions:<br />
Circuit protection against short-circuit<br />
currents.<br />
Circuit protection against overload<br />
currents.<br />
Fault tripping indication<br />
on the front panel by the<br />
position of the handle<br />
(O - I engraved)<br />
Characteristics<br />
Main characteristics<br />
Voltage rating (Ue)<br />
Operating frequency<br />
Electrical feeding<br />
230/400 V AC<br />
50/60 Hz<br />
By the top and bottom<br />
Additional characteristics<br />
Degree of protection<br />
(IEC 60529)<br />
Hazardous substances<br />
Tropicalisation (IEC 60068-1)<br />
Device only<br />
IP20<br />
RoHS 2003 compliant<br />
Treatment 2 (relative<br />
humidity 95 % to 55°C)<br />
Dimensions (mm)<br />
1P<br />
18<br />
5.5<br />
72<br />
61<br />
45<br />
82<br />
45<br />
5<br />
70<br />
Weight (g)<br />
Type<br />
Easy9 MCB<br />
1P 100<br />
20
Easy9<br />
RCBO residual current devices<br />
6 kA<br />
Certified compliant BS EN 61009-1<br />
Test "T"<br />
Operating test button,<br />
on the front panel<br />
Fault tripping indication<br />
on the front panel by the<br />
position of the handle<br />
(O - I engraved)<br />
Cable length<br />
1000 mm<br />
Characteristics<br />
Main characteristics<br />
Endurance (O-C) Electrical 4000 cycles<br />
Mechanical<br />
10000 cycles<br />
Additional characteristics<br />
Degree of protection Device only IP20<br />
Overvoltage category (IEC 60364)<br />
IV<br />
Operating temperature<br />
-15°C to +60°C<br />
Storage temperature<br />
-40°C to +85°C<br />
Hazardous substances<br />
RoHS 2003 compliant<br />
Tropicalisation (IEC 60068-1)<br />
Treatment 2 (relative<br />
humidity 95 % to 55°C)<br />
Dimensions (mm)<br />
18<br />
5.5<br />
72<br />
61<br />
50<br />
110<br />
45<br />
5<br />
44<br />
Weight (g)<br />
Type<br />
Easy9 RCBO<br />
1P+N 180<br />
21
Easy9<br />
Miniature circuit breakers<br />
Selection<br />
Time current tripping curves<br />
MCB selection chart for household appliances<br />
1000<br />
100<br />
10<br />
t(s)<br />
Appliance Capacity MCB rating (A) Tripping<br />
curves<br />
Air conditioner 1 ton 16 "C"<br />
1.5 ton 20<br />
2 ton 20<br />
3 ton 25<br />
Refrigerator 165 litres 2<br />
285 litres 2<br />
1<br />
Water heater 1 kW 6 "B"<br />
3 kW 16<br />
0,1<br />
B<br />
C<br />
Electric kettle 1.5 kW 10<br />
0,01<br />
1<br />
3...5 6.4...9.6<br />
I / In<br />
Food processor<br />
(50 % load)<br />
200 W 1 "C"<br />
Vacuum cleaner 50 W 0.5<br />
Toaster 1.2 kW 6 "B"<br />
Cooking range 750 W 4<br />
2 kW 10<br />
4.5 kW 25<br />
Room heater 1 kW 6<br />
2 kW 10<br />
Washing<br />
machine<br />
300 W 2 "C"<br />
1.3 kW 10<br />
Electric iron 750 W 6 "B"<br />
1.25 kW 6<br />
22
Easy9<br />
Circuit protection<br />
Miniature circuit breakers<br />
Function<br />
■■<br />
Protection from short-circuits.<br />
■■<br />
Protection of cable from overload.<br />
MCB current rating<br />
Single-phase circuit<br />
Selection of circuit breakers according to the cables<br />
to be protected (BS 7671)<br />
■■<br />
PVC-insulated, copper, flexible or rigid cable.<br />
■■<br />
Ambient temperature:<br />
■■<br />
30°C in the open air (methods A, B, C, E)<br />
■■<br />
20°C if buried (method D),<br />
■■<br />
For other situations, refer to BS 7671standard (or UK wiring regulations).<br />
Cable cross section (in mm 2 ) 1.5 2.5 4 6 10 16 25 35<br />
Type of installation<br />
Maximum rating of the circuit breaker used there (in Ampere)<br />
A: in conduit or directly in thermally insulated wall, moulding, architrave, window frame<br />
Single core 10 16 25 32 40 50 80 80<br />
Multicore 10 16 25 32 40 50 70 80<br />
B: in conduit in a wall, in conduit trunking or cable duct on a wall, in building cavity<br />
Single core 16 20 32 40 50 70 100 125<br />
Multicore 16 20 25 32 50 50 80 80<br />
C: direct on a wall, suspended from ceilings, on unperforated cable tray, in masonry wall<br />
Single core or<br />
multicore<br />
16 25 32 40 63 80 100 125<br />
D: in conduit in the ground<br />
Multicore or<br />
single core<br />
20 25 32 40 50 70 80 80<br />
D: directly in the ground<br />
Multicore or<br />
single core<br />
20 25 32 40 63 80 100 125<br />
E: in free-air, on cable ladder, on perforated cable tray<br />
Multicore u 0.3 d 20 25 40 40 70 80 100 125<br />
d<br />
23
Easy9<br />
Residual current devices<br />
Function<br />
■■<br />
Protection of persons against electric shock by direct contact (30 mA).<br />
■■<br />
Protection of installations against the risk of fire (300 mA).<br />
■■<br />
Protection of persons against electric shock by indirect contact<br />
(100 mA to 300 mA).<br />
Operating principle<br />
Protection from electric shocks by direct contact:<br />
10 mA<br />
40 mA<br />
0.5 mA<br />
Muscular<br />
contraction<br />
Burns<br />
respiratory<br />
Severe burns<br />
ventricular<br />
fibrilation<br />
80 mA<br />
16 A<br />
RCD<br />
30 mA<br />
30 mA<br />
Perception<br />
Cardiac arrest<br />
1 A<br />
Research worldwide shows that the intensity of current flowing<br />
through the body determines the extent and severity of an<br />
electric shock.<br />
■■<br />
Injuries become serious when currents exceed 40 to<br />
50 mA during one second.<br />
■■<br />
Theoretically, a 150 mA current flows through the<br />
body when a person touches a 230 V energised<br />
conductor under dry conditions.<br />
By measuring the intensity difference between live and neutral conductors,<br />
RCDs actually detect the current flowing through the human body.<br />
If this current reaches the 30 mA limit, the RCD trips within a few milliseconds,<br />
so preventing injury or worse.<br />
Check RCDs regularly<br />
Test<br />
Testing the RCD every<br />
3 months enables<br />
detection of any event<br />
that may have impaired<br />
its operation<br />
24
Easy9<br />
Residual current devices<br />
Selection guide<br />
Selection<br />
Residual current sensitivity<br />
Protection from Residential Non-residential Sensitivity<br />
Electric shocks by direct contact<br />
bb<br />
Mandatory protection for all socket<br />
outlets<br />
bb<br />
Mandatory protection for all electrical<br />
equipment in bathroom<br />
bb<br />
Recommended for lighting circuits<br />
bb<br />
Mandatory protection for all<br />
socket outlets<br />
bb<br />
Mandatory protection for all<br />
equipement located<br />
bb<br />
Close to water points<br />
bb<br />
30 mA<br />
bb<br />
10 mA for all applications<br />
where required by the<br />
standard (e.g.: jacuzzi,<br />
swimming pools, etc.)<br />
Fire ignited by leakage current<br />
bb<br />
Recommended in old buildings<br />
(presence of dust or moisture)<br />
bb<br />
Mandatory in all locations under<br />
risk of fire or explosion<br />
bb<br />
Recommended in all premises<br />
under presence of dust, moisture,<br />
chemical agents…<br />
bb<br />
300 mA<br />
Electric shock by indirect contact<br />
bb<br />
All circuits in case of "TT" earthing<br />
system<br />
bb<br />
All circuits in case of "TT"<br />
earthing system<br />
bb<br />
100 mA or 300 mA<br />
Current rating: shall not be<br />
in excess of upstream MCB<br />
current rating<br />
Requirements from wiring regulation (411.3.3)<br />
Protection by means of a residual current protective device (RCD),<br />
shall be provided for:<br />
■■<br />
Socket outlets with a rated current not exceeding 20 A, that are for ordinary<br />
persons and intended for general use, mobile equipment with a current rating not<br />
exceeding 32 A for use outdoors.<br />
■■<br />
In rooms containing a bath or a shower.<br />
Bathroom<br />
25
Easy9<br />
Notes<br />
26
Resi9<br />
The complete residential<br />
circuit protection offer
Resi9 consumer units<br />
The Resi9 range of consumer units provides arguably the highest levels of residential<br />
circuit protection safety. With a wide range of switch disconnectors, RCDs and MCBs,<br />
complimented by a single pole RCBO.<br />
Providing speed of installation with safety in mind.<br />
All outgoing devices can be connected in seconds and with no incoming terminal to<br />
tighten, the correct mechanical connection force is guaranteed every time. For unused<br />
ways, Resi9’s unique fully encapsulated busbar system means that the highest levels of<br />
installer and end user protection are always guaranteed.<br />
Even with the front cover of the enclosure removed, the main busbar is protected to IP2X,<br />
meaning it remains finger safe but allows access with test probes by the installer. For<br />
energy management and safety, Resi9 can also accept a wide range of control devices.<br />
“What really sets Resi9 apart is the plug-on breaker concept<br />
and fully encapsulated busbars.”
Compliant<br />
metal consumer unit<br />
BS 7671:2008<br />
Amendment 3 (2015)<br />
Features and benefits<br />
Unique MCB/RCBO fixing system.<br />
Provides complete finger safety to IP2XB, bringing<br />
increased levels of safety to consumer unit design<br />
Tested in accordance with BS EN 61439-3<br />
Unrestricted cable entry can be made from any side<br />
Totally encapsulated busbar system<br />
Incoming devices can be ordered separately giving<br />
a multitude of combinations<br />
Type A single pole RCBO<br />
Increased levels of user safety with Class II device front faces<br />
Retains plug-on philosophy for speed of installation and<br />
guaranteed connections<br />
Insulated safety pull up shuttered terminals limit incorrect<br />
cable insertion<br />
Control devices may be installed on any outgoing way<br />
No extra mounting accessories required<br />
Lockable cover option also available
Resi9<br />
Option 1<br />
Incoming switch disconnector and outgoing<br />
RCBO’s<br />
Option 2<br />
Split load consumer unit using RCBO’s<br />
Option 3<br />
Incoming switch disconnector supplying two<br />
RCD protected sections<br />
Option 4<br />
Incoming switch disconnector with RCBO<br />
ways and two RCD protected sections<br />
30
Resi9<br />
The complete solution<br />
Insulated, safety pull up shuttered<br />
terminals<br />
Finger touch proof terminals (FTPT)<br />
Class II Front face<br />
Guaranteed plug-on connections<br />
Clear and visible product information<br />
whatever the toggle position<br />
31
Unique plug on system<br />
Quick and easy to install<br />
Type A RCBO devices<br />
50% less connections to torque test<br />
BS7671 compliant enclosures<br />
Guaranteed compliance to standards<br />
32
Resi9<br />
The complete residential circuit protection offer<br />
33
Resi9<br />
Switch-disconnector<br />
ON/OFF<br />
Switch-disconnector<br />
To ensure:<br />
> > control and disconnection of loaded electrical circuits.<br />
It must be protected:<br />
--<br />
against short circuits occurring downstream<br />
--<br />
against overloads; its rating must be at least equal to the rating of the upstream<br />
circuit breaker.<br />
Type Width Operating<br />
voltage<br />
Rating<br />
Cat. no.<br />
9 mm (V AC) (A)<br />
module<br />
2P 4 400 100 R9S87291<br />
1 3<br />
2 4<br />
Degree of pollution: 2.<br />
Degree of protection (BS EN 60529): IP20B.<br />
Connection:<br />
> > copper cable:<br />
--<br />
rigid: Max. 50 mm²<br />
--<br />
flexible: Max. 35 mm².<br />
> > tightening torque: 3.5 N.m.<br />
Compliance with standards BS EN 60947-3-1<br />
34
Resi9<br />
RCBO residual current<br />
circuit breaker<br />
Residual current circuit breakers<br />
High sensitivity (30 mA)<br />
Protection against electric shocks by direct contact.<br />
Use at the incoming end of several feeders:<br />
> > recommended for all power sockets.<br />
> > compulsory for all equipment in bathrooms, outdoors, etc.<br />
Medium sensitivity (300mA) TD<br />
Protection against:<br />
> > fire following an insulation fault.<br />
> > electric shocks by indirect contact.<br />
> > in the event of tripping of a high-sensitivity residual current protection device<br />
downstream, maintains power for the other circuits.<br />
Use in residential units at the incoming end of the main switchboard.<br />
Type AC Width Operating<br />
voltage<br />
Sensitivity Rating Cat. no.<br />
9 mm (V AC) (mA) (A)<br />
module<br />
2P 4 230 30 63 R9R81263<br />
30 100 R9R81291<br />
300TD 100 R9R85291<br />
Degree of pollution: 2.<br />
Degree of protection (BS EN 60529): IP20B.<br />
Connection:<br />
> > Copper cable:<br />
--<br />
rigid: Max. 35 mm²<br />
--<br />
flexible: Max. 25 mm².<br />
> > tightening torque: 3.5 N.m.<br />
Compliance with<br />
standards<br />
BS EN 61008-1<br />
35
Resi9<br />
RCBO Residual current device<br />
Residual current devices<br />
Protection against:<br />
> > cable overloads.<br />
> > short circuits.<br />
> > electric shocks by direct contact.<br />
Use in place of a circuit breaker, for circuits requiring protection against direct contacts:<br />
> > recommended for all power sockets.<br />
> > compulsory for all equipment in bathrooms, outdoors, etc.<br />
Type A Width Operating<br />
voltage<br />
Sensitivity Rating Cat. no.<br />
9 mm (V AC) (mA) (A) B curve<br />
module<br />
1P+N 2 230 30 6 R9D87806<br />
L in<br />
10 R9D87810<br />
I Δ<br />
16 R9D87816<br />
20 R9D87820<br />
FE N in<br />
N out L out<br />
32 R9D87832<br />
40 R9D87840<br />
50 R9D87850<br />
Class Type A<br />
Breaking capacity: 6000 A.<br />
Degree of pollution: 2.<br />
Degree of protection (BS EN 60529): IP20B.<br />
Connection:<br />
> > copper cable:<br />
--<br />
rigid: Max. 25 mm²<br />
--<br />
flexible: Max. 16 mm².<br />
> > tightening torque: 2 N.m.<br />
Compliance with<br />
standards<br />
BS EN 61009-1<br />
36
Resi9<br />
Circuit breaker<br />
Circuit breakers<br />
Protection against:<br />
> > cable overloads.<br />
> > short circuits.<br />
Type Width Operating Rating Cat. no.<br />
voltage<br />
9 mm (V AC) (A) B curve C curve<br />
module<br />
1P 2 230 3 R9F87103 R9F64103<br />
1<br />
6 R9F87106 R9F64106<br />
10 R9F87110 R9F64110<br />
16 R9F87116 R9F64116<br />
2<br />
20 R9F87120 R9F64120<br />
25 R9F87125 R9F64125<br />
32 R9F87132 R9F64132<br />
40 R9F87140 R9F64140<br />
50 R9F87150 R9F64150<br />
63 R9F87163 R9F64163<br />
--<br />
Breaking capacity: 6000 A.<br />
--<br />
Degree of pollution: 2.<br />
--<br />
Degree of protection (BS EN 60529): IP20B.<br />
--<br />
Type C MCB’s denoted by grey appearance<br />
--<br />
Connection:<br />
--<br />
> copper cable:<br />
--<br />
- rigid: ≤ 25 A: Max. 25 mm2, ≥ 32 A: Max. 35 mm2<br />
--<br />
- flexible: ≤ 25 A: Max. 16 mm2, ≥ 32 A: Max. 25 mm2.<br />
--<br />
> tightening torque:<br />
--<br />
- ≤ 25 A: 2 N.m.<br />
--<br />
- ≥ 32 A: 3.5 N.m.<br />
Compliance with<br />
standards<br />
BS EN 60898-1<br />
37
Resi9<br />
Terminal block<br />
Terminal block<br />
> > Distribution and sub-distribution of the electric<br />
> > power supply.<br />
Terminal block Width Cat. no.<br />
1P<br />
100 A 18 mm SE1100L<br />
Degree of protection (BS EN 60529): IP20B.<br />
Compliance with<br />
standards<br />
BS EN 60998-1<br />
38
Easy9<br />
Quick selector<br />
Quick selector<br />
39
Select Consumer Unit<br />
Compliant<br />
metal consumer unit<br />
BS 7671:2008<br />
Amendment 3 (2015)<br />
<br />
The surface mounting enclosure consists of:<br />
> > Metal surface mounting enclosure with:<br />
> > Multiple cable entry points and rear knock out slots<br />
> > Secure fixed plug on assembly<br />
> > Fully encapsulated bus bar assembly<br />
> > Earth terminal block and neutral blocks fitted as standard<br />
> > Standard consumer units up to 24 ways<br />
> > Earthed cover<br />
> > Enclosure colour: White RAL 9003<br />
Consumer Unit<br />
Reference Description No of ways<br />
R9BM2L 2 Way Resi9 metal CU 2<br />
R9BM4L 4 Way Resi9 metal CU 4<br />
R9BM6L 6 Way Resi9 metal CU 6<br />
R9BM8L 8 Way Resi9 metal CU 8<br />
R9BM12L 12 Way Resi9 metal CU 12<br />
R9BM16L 16 Way Resi9 metal CU 16<br />
Dual bank<br />
Reference Description No of ways<br />
R9BM24L 24 Way Resi9 metal CU 24<br />
Split Load<br />
Reference Description No of ways<br />
R9BMS4R6L 4+6 Resi9 metal CU 4+6 split load<br />
R9BMS6R4L 6+4 Resi9 metal CU 6+4 split load<br />
R9BMS5R5L 5+5 Resi9 metal CU 4+4 split load<br />
R9BMS7R7L 7+7 Resi9 metal CU 7+7 split load<br />
Dual RCCB - Including Incomers<br />
Reference Description No of ways<br />
R9BMSR6R6L 6+6 Resi9 metal CU inc 100a Sw & 2 x 63a RCCBs 6+6 dual split<br />
R9BMS2R5R5L 2+5+5 Resi9 metal CU inc 100a Sw & 2 x 63a RCCBs cw 2 unprotected ways 2,5,5, multiple split<br />
R9BMDS2R5R5L 2+5+5 Resi9 metal CU inc 100a Sw & 2 x 100a RCCBs cw 2 unprotected ways 2,5,5, multiple split<br />
40
Select devices<br />
Incoming Devices<br />
R9R81263<br />
R9R81291<br />
R9R85291<br />
R9S87291<br />
SE1100L<br />
63A/30mA RCCB<br />
100A/30mA RCCB<br />
100A/300mA RCCB TD<br />
100A Switch Disconnector<br />
100A 1P Terminal Block<br />
Outgoing Device<br />
MCB’s type B<br />
MCB’s type C<br />
R9F87103 Single Pole 3A Type B MCB 6kA R9F64103 Single Pole 3A Type C MCB 6kA<br />
R9F87106 Single Pole 6A Type B MCB 6kA R9F64106 Single Pole 6A Type C MCB 6kA<br />
R9F87110 Single Pole 10A Type B MCB 6kA R9F64110 Single Pole 10A Type C MCB 6kA<br />
R9F87116 Single Pole 16A Type B MCB 6kA R9F64116 Single Pole 16A Type C MCB 6kA<br />
R9F87120 Single Pole 20A Type B MCB 6kA R9F64120 Single Pole 20A Type C MCB 6kA<br />
R9F87125 Single Pole 25A Type B MCB 6kA R9F64125 Single Pole 25A Type C MCB 6kA<br />
R9F87132 Single Pole 32A Type B MCB 6kA R9F64132 Single Pole 32A Type C MCB 6kA<br />
R9F87140 Single Pole 40A Type B MCB 6kA R9F64140 Single Pole 40A Type C MCB 6kA<br />
R9F87150 Single Pole 50A Type B MCB 6kA R9F64150 Single Pole 50A Type C MCB 6kA<br />
R9F87163 Single Pole 63A Type B MCB 6kA R9F64163 Single Pole 63A Type C MCB 6kA<br />
RCBO’s - Type A<br />
R9D87806<br />
R9D87810<br />
R9D87816<br />
R9D87820<br />
R9D87825<br />
R9D87832<br />
R9D87840<br />
R9D87850<br />
Single Pole 6A/30mA B Curve RCBO<br />
Single Pole 10A/30mA B Curve RCBO<br />
Single Pole 16A/30mA B Curve RCBO<br />
Single Pole 20A/30mA B Curve RCBO<br />
Single Pole 25A/30mA B Curve RCBO<br />
Single Pole 32A/30mA B Curve RCBO<br />
Single Pole 40A/30mA B Curve RCBO<br />
Single Pole 50A/30mA B Curve RCBO<br />
Control devices and accessories<br />
A9C20732<br />
ICT 25A 2NO 230...240VAC 50HZ Contactor<br />
A9C20834<br />
ICT 25A 4NO 220...240VAC 50HZ Contactor<br />
A9C20842<br />
ICT 40A 2NO 220...240VAC 50HZ Contactor<br />
A9C20843<br />
ICT 40A 3NO 220...240VAC 50HZ Contactor<br />
A9C20844<br />
ICT 40A 4NO 220...240VAC 50HZ Contactor<br />
A9C20863<br />
ICT 63A 3NO 220...240VAC 50HZ Contactor<br />
A9C30811 ITL16A 1NO 230/240VAC 110VDC 50-60<br />
A9C30812<br />
ITL16A 2NO 230/240VAC 50-60HZ 110V<br />
A9E15535 CHANGEOVER RELAY IRLI 10A 2P UC 230V-240<br />
A9A15321<br />
ISO BELL 8 12V<br />
A9A15214<br />
BELL TRANSFORMER 4VA 230VCA 8VCA<br />
A9A15323<br />
BUZZER 8..12 VCA 70DBA 50..60HZ<br />
CCT15368<br />
IC2000 light sensitive switch<br />
15336 24HR analogue time switch with reserve<br />
CCT15720<br />
1 Channel IHP program time switch<br />
CCT15722<br />
2 Channel IHP program time switch<br />
15363 MIN time switch 1-7mins (delayed off)<br />
A9A27062<br />
5X Spacer 9MM - 1/2 module blank<br />
SEPLMCB<br />
MCB Padlock attachment (pk10) MCB<br />
SEPLRCBO<br />
RCBO Padlock attachment (pk10) RCBO<br />
SEPL<br />
Padlock (can be used with MCB or RCBO attachment)<br />
EZ9LKITL<br />
Door lock kit (for AMD3 metal enclosure only)<br />
SEDNBP3<br />
3 module blanking plate module<br />
Control devices<br />
May be installed at any outgoing point on the RCD protected or unprotected side<br />
41
Easy9<br />
Technical guide<br />
Technical guide<br />
42
Resi9 - metal unit dimensions<br />
Metal Units<br />
Ref No. Type Useable No Ways Height (mm) Width (mm) Depth (mm)<br />
R9BM2L Standard 2 247 186 112<br />
Metal R9BM4L units Standard 4 247 Dimensions (mm) 222 No. 112of knockouts<br />
Reference R9BM6L number Standard No. of 6 ways Type 247 A B 258 D E 112 F G H<br />
R9BM8L Standard 8 247 294 112<br />
25 x 89 30mm 25mm 20mm<br />
R9BM12L Standard 12 247 366 112<br />
R9BM2 2 Standard 181 119 – 2 2 8 –<br />
R9BM4 R9BM16L Standard 4 16 Standard 247 222 155 4382 2 112 2 8 –<br />
R9BM6 R9BM24L R9BM6SG Standard 6 24 Standard 487 258 191 366– 2 112 4 8 –<br />
R9BM8 R9BMS4R6L R9BM8SG Split 8 10 Standard 247 294 227 366– 2 112 4 10 2<br />
R9BM12 R9BM12SG 12 Standard 366 299 4 4 4 12 –<br />
R9BMS6R4L Split 10 247 366 112<br />
R9BM16 16 Standard 438 371 4 4 4 16 –<br />
R9BM24<br />
R9BMS5R5L Split<br />
24<br />
10<br />
Standard<br />
247<br />
366 299<br />
366<br />
6 4<br />
112<br />
4 8 –<br />
R9BMS4R6 R9BMSR6R6L Split 4+6 12 Split 247 378 299 4384 4 112 4 12 –<br />
R9BMS5R5 R9BMS7R7L Split 5+5 14 Split 247 378 299 4384 4 112 4 12 –<br />
R9BMS6R4 R9BMS2R5R5L Multiple 6+4 12 Split 247 378 299 4384 4 112 4 12 –<br />
R9BMS7R7 7+7 Split 450 371 4 4 4 16 –<br />
R9BMDS2R5R5L Multiple 12 247 438 112<br />
R9BMSR6R6 R9BMSR6R6SG 6+6 Multiple 450 371 4 4 4 16 –<br />
R9BMDS2R5R5 R9BMDS2R5R5SG 2+5+5 Multiple 450 371 4 4 4 16 –<br />
R9BMS2R5R5 R9BMS2R5R5SG 2+5+5 Multiple 450 371 4 4 4 16 –<br />
Note: Rear of enclosure = 242mm high<br />
Incoming and outgoing devices must be selected separately from the Resi9 devices section.<br />
The following ref’s are supplied with switch disconnector and RCDs fitted:- R9BMSR6R6L, R9BMDS2R5R5L, R9BMS2R5R5L<br />
Cable entry sizes (mm)<br />
Height 247mm<br />
Depth 111mm<br />
5.5Ø<br />
63<br />
D<br />
2 WAY ONLY<br />
H<br />
F<br />
D<br />
116<br />
111<br />
86<br />
9.5Ø<br />
61<br />
54<br />
180<br />
247 (surface)<br />
259 (flush)<br />
5.5Ø 73<br />
D<br />
H<br />
F<br />
D<br />
31 B<br />
A<br />
Dotted line<br />
indicates cover<br />
39<br />
27<br />
(all dimensions in mm)<br />
44 54<br />
43<br />
27<br />
G<br />
E<br />
E<br />
F<br />
F<br />
G<br />
G<br />
G<br />
G<br />
G<br />
27<br />
12 & 16 Way only<br />
6 to 16 Way only<br />
4 to 16 Way only<br />
43
Technical data<br />
Metal<br />
Max. busbar current rating (A) 100<br />
Max. operating voltage (V) 240<br />
Operating frequency (Hz) 50<br />
Max. incoming cable capacity mm2 (phase and neutral) 50<br />
Max. outgoing cable capacity mm2 25<br />
Certification BS EN 61439-3<br />
IP rating BS EN 60529 (internal)<br />
IP2XB<br />
No. Of knockouts<br />
Dimensions (mm)<br />
25 x<br />
90mm<br />
32mm 25mm 20mm<br />
Ref No. A B D E F G<br />
R9BM2L 181 119 - 2 2 8<br />
R9BM4L 217 155 2 2 2 8<br />
R9BM6L 253 191 2 2 4 8<br />
R9BM8L 289 227 2 2 4 10<br />
R9BM12L 361 299 4 4 4 12<br />
R9BM16L 433 371 4 4 4 16<br />
R9BM24L 361 299 6 4 4 8<br />
R9BMS4R6L 361 299 4 4 4 12<br />
R9BMS6R4L 361 299 4 4 4 12<br />
R9BMS5R5L 361 299 4 4 4 12<br />
R9BMSR6R6L 433 371 4 4 4 16<br />
R9BMS7R7L 433 371 4 4 4 16<br />
R9BMDS2R5R5L 433 371 4 4 4 16<br />
R9BMS2R5R5L 433 371 4 4 4 16<br />
For short circuit back-up protection, maximum fuse rating:-<br />
Residual current breakers<br />
Reference number Description Cable capacity Dimensions Weight<br />
mm2 Height Width Depth kg<br />
SED25032 25A RCCB 30mA trip 2 pole 35 81 36 75 0.227<br />
SED25302 25A RCCB 300mA trip 2 pole 35 81 36 75 0.227<br />
SED40032 40A RCCB 30mA trip 2 pole 35 81 36 75 0.227<br />
SED40102 40A RCCB 100mA trip 2 pole 35 81 36 75 0.227<br />
SED40302 40A RCCB 300mA trip 2 pole 35 81 36 75 0.227<br />
SED63032 63A RCCB 30mA trip 2 pole 35 81 36 75 0.227<br />
SED63102 63A RCCB 100mA trip 2 pole 35 81 36 75 0.227<br />
SED63302 63A RCCB 300mA trip 2 pole 35 81 36 75 0.227<br />
SED80032 80A RCCB 30mA trip 2 pole 50 81 36 75 0.227<br />
SED100032 100A RCCB 30mA trip 2 pole 50 81 36 75 0.227<br />
SED100102 100A RCCB 100mA trip 2 pole 50 81 36 75 0.227<br />
44
UK contact details -<br />
0870 608 8 608<br />
Fax 0870 608 8 606<br />
Ireland contact details -<br />
01 601 2200<br />
Fax 01 601 2201<br />
As the global specialist in energy management with operations in more<br />
than 100 countries, Schneider Electric offers integrated solutions across<br />
multiple market segments, including leadership positions in energy<br />
and infrastructure, industrial processes, building automation, and data<br />
centres/networks, as well as a broad presence in residential applications.<br />
Schneider Electric is dedicated to making individuals’ and organisations’<br />
energy safe, reliable, efficient, productive and green from Power Plant to<br />
Plug TM .<br />
We are changing our brand names and becoming one Schneider Electric.<br />
You’ll get the same great quality products, but from one name you can remember and<br />
trust. This provides you and your customers with the reassurance associated with<br />
Schneider Electric.<br />
Some of our market leading brands have already become Schneider Electric including<br />
Merlin Gerin, Telemecanique, Square D, GET, Mita, Sarel, Himel, Thorsman,<br />
Tower and TAC.<br />
Working as one Schneider Electric makes it clearer that our ranges are highly compatible<br />
for integrated solutions.<br />
Schneider Electric Ltd<br />
United Kingdom<br />
Stafford Park 5,<br />
Telford<br />
Shropshire<br />
TF3 3BL<br />
Tel: 0870 608 8 608<br />
Fax: 0870 608 8 606<br />
www.schneider-electric.com/uk<br />
Ireland<br />
Head office,<br />
Block a<br />
Maynooth Business Campus<br />
Maynooth, Co. Kildare<br />
Tel: (01) 601 2200<br />
Fax: (01) 601 2201<br />
www.schneider-electric.com/ie<br />
Schneider Electric Limited is a company registered in England and Wales.<br />
Registered number: 1407228. Registered office: Stafford Park 5, Telford, Shropshire TF3 3BL.<br />
© 2014 Schneider Electric. All Rights Reserved. Schneider Electric, Active Energy Management,<br />
Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact,<br />
Micrologic, Power Plant To Plug, Modbus, and PowerLogic are owned by Schneider Electric<br />
Industries SAS, or its affiliated companies in the United States and other countries.<br />
As standards, specifications and designs change from time to time, please ask for confirmation<br />
of the information given in this publication.<br />
SE8899 FEB 2015<br />
member of