Product Description<br />

SABROE <strong>Marine</strong> <strong>Condensing</strong> <strong>Unit</strong>s<br />

Features<br />

• <strong>Marine</strong> condensing units are designed and produced<br />

by <strong>YORK</strong> for long service in heavy sea conditions<br />

• Factory designed and assembled units with integrated<br />

condenser, liquid receiver and heat exchanger for<br />

minimum space requirements and easy installation.<br />

• Designed for various HFC or HCFC refrigerants<br />

• Designed for air conditioning cooling capacities,<br />

50-450 kW<br />

Compressors<br />

Compressors are the latest of <strong>YORK</strong>’s world renown<br />

CMO and SMC multicylinder, directly or belt driven types.<br />

They include:<br />

•<br />

cylinder unloading capacity regulation<br />

positive lubrication by integral oil pump<br />

integral safety valve<br />

integral suction strainer<br />

suction and discharge isolating valves<br />

crankcase heater<br />

oil level sight glass<br />

oil charging and evacuation valves.<br />

...Suction/liquid<br />

heat exchanger<br />

is incorporated<br />

to ensure safe<br />

operation...<br />

Type MCU 20,30 and 100<br />

Global reach<br />

Our global service & parts<br />

network ensures customers an<br />

organisation with a global reach<br />

that is also known and active at<br />

the local level.<br />

Improvements<br />

To continually improve the value<br />

we provide to customers we<br />

strive to become more competitive<br />

and capture new opportunities.<br />

Innovative<br />

We believe that there is always<br />

a better way. This belief inspires<br />

to new solutions, change and<br />

opportunity we pass on to our<br />

customers.<br />

Customer satisfaction<br />

Costumer focus is our key to success.<br />

Our 130.000 global colleagues strive<br />

to serve our customers in the best<br />

way to create long term relationship<br />

and mutual growth.<br />

Sustainability<br />

We believe in the future and we<br />

believe that sustainability will play<br />

a significant role in any future<br />

development of our products,<br />

services and operations.<br />

Quality<br />

We will distinguish ourselves with<br />

our customers through the exceptional<br />

quality of our products and<br />

services.


Traditional unit controls<br />

We can still offer traditional controls as an option.<br />

Traditional unit controls include:<br />

• Low pressure cut-out, which will stop the compressor at a preset<br />

minimum suction pressure. Automatic reset after stop.<br />

• High pressure cut-out, which will stop the compressor at a preset<br />

maximum discharge pressure. Manual reset required after<br />

stop.<br />

• Low oil pressure cut-out, which will stop the compressors at a<br />

pre-set minimum differential pressure.<br />

The cut-out incorporates an electro-mechanical time delay and<br />

is manually reset after stop.<br />

Classification<br />

The design and construction is approved by all leading<br />

Classification Societies. Specific certification must be stated<br />

at time of order.<br />

<strong>Unit</strong> type * Length Width Height Weight Service space Max. capacity Drawing<br />

mm mm mm kg ** mm kW *** No.<br />

MCU34/271954V 2342 876 1185 730 1701 95 4823-128<br />

MCU34/271954D 2342 720 1272 730 1701 95 4823-127<br />

MCU34/272366V 2722 876 1185 830 2026 105 4823-116<br />

MCU34/272366D 2722 720 1272 760 2026 105 4823-115<br />

MCU 26/271954V 2342 876 1185 760 1701 135 4823-130<br />

MCU 26/271954D 2342 720 1272 730 1701 135 4823-129<br />

MCU 26/272366V 2722 876 1185 860 2026 150 4823-118<br />

MCU 26/272366D 2722 720 1272 790 2026 150 4823-117<br />

MCU 26/411910V 2549 952 1493 905 1574 158 4823-120<br />

MCU 26/411910D 2549 900 1482 835 1574 158 4823-119<br />

MCU 28/272366V 2722 952 1363 710 2026 185 4823-126<br />

MCU 28/272366D 2722 720 1313 685 2026 185 4823-125<br />

MCU 28/411910V 2549 952 1493 880 1574 205 4823-121<br />

MCU 28/411910D 2549 900 1482 810 1574 205 4823-122<br />

MCU 28/501917V 2651 952 1651 1123 1549 205 4823-132<br />

MCU 28/501917D 2651 900 1600 1013 1549 205 4823-131<br />

MCU 28/502320V 3031 952 1651 1193 1899 215 4823-124<br />

MCU 28/502320D 3031 900 1600 1083 1899 215 4823-123<br />

MCU 106/272366V 2824 1150 1512 1080 1924 190 4822-051<br />

MCU 106/272366D 2824 908 1512 1030 1924 190 4822-050<br />

MCU 106/411910V 2548 1150 1732 1253 1574 250 4822-047<br />

MCU 106/411910D 2548 932 1732 1231 1574 250 4822-046<br />

MCU 106/501917V 2727 1150 1802 1605 1880 290 4822-053<br />

MCU 106/501917D 2727 932 1892 1605 1822 290 4822-052<br />

MCU 106/502320V 3107 1150 1802 1480 1880 305 4822-043<br />

MCU 106/502320D 3107 932 1847 1458 1880 317 4822-042<br />

MCU 108/411910V 2548 1150 1732 1253 1574 245 4822-049<br />

MCU 108/411910D 2548 957 1729 1231 1574 245 4822-048<br />

MCU 108/501917V 2727 1119 1802 1462 1472 370 4822-055<br />

MCU 108/501917D 2727 948 1844 1430 1472 370 4822-054<br />

MCU 108/502320V 3107 1150 1802 1532 1880 395 4822-045<br />

MCU 108/502320D 3107 948 1844 1500 1880 410 4822-044<br />

* V = V-belt D = direct ** Weight excl motor *** Approx max capacity:<br />

32°C condensing water temperature,<br />

+5°C evaporating temperature,<br />

Refrigerants R22, R404A, R407C, R507<br />

The above technical information is subject to updates in content and specification without prior notice<br />

www.johnsoncontrols.com/marine