Condensing Unit Sabroe - YORK Marine
Condensing Unit Sabroe - YORK Marine
Condensing Unit Sabroe - YORK Marine
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Product Description<br />
SABROE <strong>Marine</strong> <strong>Condensing</strong> <strong>Unit</strong>s<br />
Features<br />
• <strong>Marine</strong> condensing units are designed and produced<br />
by <strong>YORK</strong> for long service in heavy sea conditions<br />
• Factory designed and assembled units with integrated<br />
condenser, liquid receiver and heat exchanger for<br />
minimum space requirements and easy installation.<br />
• Designed for various HFC or HCFC refrigerants<br />
• Designed for air conditioning cooling capacities,<br />
50-450 kW<br />
Compressors<br />
Compressors are the latest of <strong>YORK</strong>’s world renown<br />
CMO and SMC multicylinder, directly or belt driven types.<br />
They include:<br />
•<br />
cylinder unloading capacity regulation<br />
positive lubrication by integral oil pump<br />
integral safety valve<br />
integral suction strainer<br />
suction and discharge isolating valves<br />
crankcase heater<br />
oil level sight glass<br />
oil charging and evacuation valves.<br />
...Suction/liquid<br />
heat exchanger<br />
is incorporated<br />
to ensure safe<br />
operation...<br />
Type MCU 20,30 and 100<br />
Global reach<br />
Our global service & parts<br />
network ensures customers an<br />
organisation with a global reach<br />
that is also known and active at<br />
the local level.<br />
Improvements<br />
To continually improve the value<br />
we provide to customers we<br />
strive to become more competitive<br />
and capture new opportunities.<br />
Innovative<br />
We believe that there is always<br />
a better way. This belief inspires<br />
to new solutions, change and<br />
opportunity we pass on to our<br />
customers.<br />
Customer satisfaction<br />
Costumer focus is our key to success.<br />
Our 130.000 global colleagues strive<br />
to serve our customers in the best<br />
way to create long term relationship<br />
and mutual growth.<br />
Sustainability<br />
We believe in the future and we<br />
believe that sustainability will play<br />
a significant role in any future<br />
development of our products,<br />
services and operations.<br />
Quality<br />
We will distinguish ourselves with<br />
our customers through the exceptional<br />
quality of our products and<br />
services.
Traditional unit controls<br />
We can still offer traditional controls as an option.<br />
Traditional unit controls include:<br />
• Low pressure cut-out, which will stop the compressor at a preset<br />
minimum suction pressure. Automatic reset after stop.<br />
• High pressure cut-out, which will stop the compressor at a preset<br />
maximum discharge pressure. Manual reset required after<br />
stop.<br />
• Low oil pressure cut-out, which will stop the compressors at a<br />
pre-set minimum differential pressure.<br />
The cut-out incorporates an electro-mechanical time delay and<br />
is manually reset after stop.<br />
Classification<br />
The design and construction is approved by all leading<br />
Classification Societies. Specific certification must be stated<br />
at time of order.<br />
<strong>Unit</strong> type * Length Width Height Weight Service space Max. capacity Drawing<br />
mm mm mm kg ** mm kW *** No.<br />
MCU34/271954V 2342 876 1185 730 1701 95 4823-128<br />
MCU34/271954D 2342 720 1272 730 1701 95 4823-127<br />
MCU34/272366V 2722 876 1185 830 2026 105 4823-116<br />
MCU34/272366D 2722 720 1272 760 2026 105 4823-115<br />
MCU 26/271954V 2342 876 1185 760 1701 135 4823-130<br />
MCU 26/271954D 2342 720 1272 730 1701 135 4823-129<br />
MCU 26/272366V 2722 876 1185 860 2026 150 4823-118<br />
MCU 26/272366D 2722 720 1272 790 2026 150 4823-117<br />
MCU 26/411910V 2549 952 1493 905 1574 158 4823-120<br />
MCU 26/411910D 2549 900 1482 835 1574 158 4823-119<br />
MCU 28/272366V 2722 952 1363 710 2026 185 4823-126<br />
MCU 28/272366D 2722 720 1313 685 2026 185 4823-125<br />
MCU 28/411910V 2549 952 1493 880 1574 205 4823-121<br />
MCU 28/411910D 2549 900 1482 810 1574 205 4823-122<br />
MCU 28/501917V 2651 952 1651 1123 1549 205 4823-132<br />
MCU 28/501917D 2651 900 1600 1013 1549 205 4823-131<br />
MCU 28/502320V 3031 952 1651 1193 1899 215 4823-124<br />
MCU 28/502320D 3031 900 1600 1083 1899 215 4823-123<br />
MCU 106/272366V 2824 1150 1512 1080 1924 190 4822-051<br />
MCU 106/272366D 2824 908 1512 1030 1924 190 4822-050<br />
MCU 106/411910V 2548 1150 1732 1253 1574 250 4822-047<br />
MCU 106/411910D 2548 932 1732 1231 1574 250 4822-046<br />
MCU 106/501917V 2727 1150 1802 1605 1880 290 4822-053<br />
MCU 106/501917D 2727 932 1892 1605 1822 290 4822-052<br />
MCU 106/502320V 3107 1150 1802 1480 1880 305 4822-043<br />
MCU 106/502320D 3107 932 1847 1458 1880 317 4822-042<br />
MCU 108/411910V 2548 1150 1732 1253 1574 245 4822-049<br />
MCU 108/411910D 2548 957 1729 1231 1574 245 4822-048<br />
MCU 108/501917V 2727 1119 1802 1462 1472 370 4822-055<br />
MCU 108/501917D 2727 948 1844 1430 1472 370 4822-054<br />
MCU 108/502320V 3107 1150 1802 1532 1880 395 4822-045<br />
MCU 108/502320D 3107 948 1844 1500 1880 410 4822-044<br />
* V = V-belt D = direct ** Weight excl motor *** Approx max capacity:<br />
32°C condensing water temperature,<br />
+5°C evaporating temperature,<br />
Refrigerants R22, R404A, R407C, R507<br />
The above technical information is subject to updates in content and specification without prior notice<br />