Remote control CERT cables HN 33-S-34 - Nexans
Remote control CERT cables HN 33-S-34 - Nexans
Remote control CERT cables HN 33-S-34 - Nexans
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ContactPower LV and MV <strong>cables</strong> andcomponents (up to 110 kV)Phone: +7 495 545 05 38ilya.kostikov@nexans.com<strong>Remote</strong> <strong>control</strong> <strong>CERT</strong> <strong>cables</strong> <strong>HN</strong> <strong>33</strong>-S-<strong>34</strong>- <strong>Remote</strong> <strong>control</strong> <strong>cables</strong> 0.6/1 kV- PVC insulation- Overall Screen (OS)DescriptionApplicationThese <strong>cables</strong> are used in transformer stations.They are protected against electromagnetic interferences.DesignConductor:Stranded bare copper (class 2)Insulation:Polyvinyl chloride (PVC)Assembling tape (optional):Inner sheath:Polyvinyl chloride (PVC)Screen:Corrugated copper tapeStandardsInternational HD 604 S1 ;IEC 60228National <strong>HN</strong> <strong>33</strong>-S-<strong>34</strong>; NF C 32-070/C1Outer sheath:Polyvinyl chloride (PVC)Colour : blackMarkingRTE V <strong>33</strong>-S-<strong>34</strong> Nber of cores & cross-section NEXANS 279 MM YYYY+ metricmarkingCore identificationBlack core printedBrown, yellow, green and light blue for:3 x 25 + 163 x 50 + 253 x 95 + 35StandardsConform to the "Centre National d'Ingénierie Réseaux" (CNIR) spécifications andRated Voltage Uo/U(Um)0.6/1 kVMechanical resistance toimpactsMediumFire retardantC1, NF C 32-070Operating temp.range-20 .. 60 °CMax.conductor temp.inservice70 °CElectro magnetic interferenceresistanceYesVersion fd2 Generated 6/18/14 - http://www.nexans.ru Page 1 / 2All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<strong>Nexans</strong> is indicative only and shall not be binding on <strong>Nexans</strong> or be treated as constituting a representation on the part of <strong>Nexans</strong>.
ContactPower LV and MV <strong>cables</strong> andcomponents (up to 110 kV)Phone: +7 495 545 05 38ilya.kostikov@nexans.com<strong>Remote</strong> <strong>control</strong> <strong>CERT</strong> <strong>cables</strong> <strong>HN</strong> <strong>33</strong>-S-<strong>34</strong>EDF <strong>HN</strong> <strong>33</strong>-S-<strong>34</strong> nomenclature.CharacteristicsConstruction characteristicsConductor materialCopperInsulationPVCInner sheathPVCScreenCorrugated copper screenOuter sheathPVCElectrical characteristicsRated Voltage Uo/U (Um)0.6/1 kVMechanical characteristicsMechanical resistance to impactsMediumUsage characteristicsFire retardant C1, NF C 32-070Operating temperature, range -20 .. 60 °CMax. conductor temperature in service 70 °CElectro magnetic interference resistanceYesSelling informationMinimum bending radius:Cut to length10 x outer diameterTo be doubled during laying operationsRated Voltage Uo/U(Um)0.6/1 kVMechanical resistance toimpactsMediumFire retardantC1, NF C 32-070Operating temp.range-20 .. 60 °CMax.conductor temp.inservice70 °CElectro magnetic interferenceresistanceYesVersion fd2 Generated 6/18/14 - http://www.nexans.ru Page 2 / 2All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<strong>Nexans</strong> is indicative only and shall not be binding on <strong>Nexans</strong> or be treated as constituting a representation on the part of <strong>Nexans</strong>.