10.07.2015 Views

HVAC Pages 2-51 - Supco

HVAC Pages 2-51 - Supco

HVAC Pages 2-51 - Supco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TimersMechanical Defrost ControlsFeatures• Dial: 24 Hour, with inner dial adjustable for defrost and 5 dial pins.• Defrost Frequency: Adjustable from 1 t o 6 cycles per day; minimum of 4 hours between successive defrost cycles.• Defrost Duration: Adjustable from 4 to 110 minutes in 2 minute increments.• Switch Rating: 40 amps resistive, 2 HP per pole, 690 VA pilot duty, 120 – 240 volts AC.• Enclosure: Heavy steel NEMA1 indoor enclosure with knockouts at bottom, back and sides. Spring hasp, with hole for a6041061410lock, holds permanently attached, side hinged door.Applications• Commercial freezer and cooler evaporatorsAccessoriesX6000 - Trippers (5 per package)• 6040 Contact Arrangement: Choice of four contactarrangements for electric heat, hot gas, orcompressor shut down defrost.• Time Initiated - Time Terminated• 6140 Contact Arrangement: Choice of three contactarrangements for electric heat, hot gas or compressorshut down defrost.• 6140 Defrost Termination: For use with externaltemperature or pressure sensor. Inner dial provides backup defrost termination and protects against sensormalfunction.• Time Initiated - Time TerminatedGeneral Purpose 24 Hour Mechanical TypeCD101Features• Dial: 24 hour, 2 on and 2 off trippers• Switch Rating: 40 amps resistive or tungsten, 1000 VA pilot duty, 2 HP and 120 or 240 volts.• Operations: Up to 10 ON/OFF operations per 24 hours. With manual ON/OFF switch that allows circuit to be hand operatedwithout disturbing scheduled setting.• Minimum Setting: 1 hour between On/OFF, 2 hours between OFF/ON.• Enclosure: Non corrosive NEMA 1CD100 SeriesApplications• Pool filter pumps• Pool heaters• Indoor and outdoor lighting systems• Sprinkler systemsUniversal Defrost Timers/Temporary ControlSA1005 Defrost TimerFeatures/Benefits• Allows normal refrigerator defrost operationwhen icemaker is removed from system.• Direct "plug-in" fit with either suction cup orpermanent screw-mounting.6040 Series Mechanical Defrost ControlNORMAL POSITIONS OF CONTACTSDURING REFRIGERATION CYCLEREPLACES VOLTS CONTACT CONTACT CONTACTSPART NO. PARAGON 60 Hz. N-3 1-3 2-460410 8041-00 120 closed open closed604120 8041-20 208-240 closed open closed60450 8045-00 120 none open closed604520 8045-20 208-240 none open closed6140 Series Mechanical Defrost ControlREPLACES VOLTS CONTACT CONTACT CONTACTSPART NO. PARAGON 60 Hz. N-3 1-3 2-461410 8141-00 120 closed open closed614120 8141-20 208-240 closed open closed61450 8145-00 120 none open closed614520 8145-20 208-240 none open closedAccessoriesX100 - Trippers (2 per package)REPLACESPART NO. PARAGON VOLTS SWITCH ENCLOSURECD101 4001-00 120 SPST NEMA1CD104 4004-71 240 DPST NEMA1Applications• Fits All Whirlpool & SearsRefrigerators with Flexible TrayIcemakers®®SC1002 Temporary Cold ControlFeatures/Benefits• Temporary Emergency Universal Replacement• Keeps Equipment Up & Running Until Exact Replacementor Permanent Control Is Installed• SC1002 Can Be Used As Permanent Control• Three Mounting Options Available Suction Cup,Velcro or Screw Mounting• Safe & Easy InstallationApplications• Domestic & Commercial Refrigerators & FreezersPART NO. TEMP. RANGE DIFF °F SWITCHSC1002 -6°F to +40°F 7° SPST1<strong>51</strong>5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!