18.11.2012 Views

Jaga Taboe

Jaga Taboe

Jaga Taboe

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

72<br />

2<br />

1<br />

3<br />

1. <strong>Taboe</strong> Sani<br />

2. <strong>Taboe</strong><br />

3. <strong>Taboe</strong> Freestanding


74<br />

2<br />

1<br />

1. <strong>Taboe</strong> Sani Single<br />

2. <strong>Taboe</strong> Sani Double


<strong>Taboe</strong> Sani<br />

75


76<br />

<strong>Taboe</strong> Sani<br />

Dimensions<br />

TSSW_<strong>Taboe</strong> Sani Single Wall<br />

7.2<br />

TSDW_<strong>Taboe</strong> Sani Double Wall<br />

7.2<br />

H<br />

20.0<br />

G1/2"<br />

10.0 20.0<br />

50.0<br />

G1/2"<br />

11.0<br />

11.0<br />

movable wall fixing<br />

Connections<br />

Code: 1° number = flow<br />

2° number = return<br />

4 5<br />

Standard connection<br />

Code 18<br />

Connection 18 or 81<br />

To the floor:<br />

To the wall:<br />

1 8<br />

Top end connection<br />

Ordering code: specify 45 or 54 instead of 18.<br />

Insert pipe is delivered without surcharge, to<br />

be mounted in the return. Provide an air vent<br />

on the central heating tube.<br />

With electric element<br />

Ordering code: Standard code 18, and order<br />

an electric element.<br />

Mixed<br />

Ordering code: standard code 18.<br />

Order an electric element and T-piece.<br />

- Fit the T-piece together with the electric heating<br />

element for connection to the central<br />

heating wet system.<br />

- Never isolate the radiator from the expansion<br />

system, in other words never cut off the<br />

return of the radiator.<br />

2.5 cm<br />

7.2<br />

10<br />

7.2 10<br />

7.2 cm<br />

10 cm<br />

Range<br />

Single<br />

121<br />

Double<br />

121<br />

50<br />

50<br />

182<br />

182<br />

50<br />

50


Outputs<br />

<strong>Taboe</strong> Sani_single<br />

H L 050<br />

121 75/65/20 590<br />

90/70/20<br />

s<br />

o<br />

759<br />

182 75/65/20 887<br />

90/70/20 1143<br />

st. colour € 592,40<br />

other € 681,30<br />

<strong>Taboe</strong> Sani_double<br />

H L 050<br />

121 75/65/20 800<br />

90/70/20<br />

s<br />

o<br />

1018<br />

182 75/65/20 1206<br />

90/70/20<br />

s<br />

o<br />

1545<br />

<strong>Taboe</strong> Sani_single<br />

brushed stainless steel<br />

H L 050<br />

121 75/65/20 459<br />

90/70/20<br />

b<br />

581<br />

182 75/65/20 627<br />

90/70/20<br />

b<br />

799<br />

<strong>Taboe</strong> Sani_double<br />

brushed stainless steel<br />

H L 050<br />

121 75/65/20 664<br />

90/70/20<br />

b<br />

847<br />

182 75/65/20 967<br />

90/70/20<br />

b<br />

1239<br />

code height length colour conn.<br />

ORDERING CODE : TSSW. 121 050. XXX /18<br />

Standard delivery<br />

- central connection 18 underneath<br />

- wall fixing set<br />

- chrome-plated air vent and drain cock<br />

Standard colours:<br />

- white (333) RAL 9016 satin<br />

- white (301) RAL 9010 satin<br />

- sandblast grey metallic 001<br />

code height length colour conn.<br />

ORDERING CODE : TSDW. 121 050. XXX /18<br />

Standard delivery<br />

- central connection 18 underneath<br />

- wall fixing set<br />

- chrome-plated air vent and drain cock<br />

Standard colours:<br />

- white (333) RAL 9016 satin<br />

- white (301) RAL 9010 satin<br />

- sandblast grey metallic 001<br />

code height length colour conn. type<br />

ORDERING CODE : TSSW. 121 050. 011 /18 /SP<br />

Standard delivery<br />

- brushed stainless steel<br />

- central connection 18 underneath<br />

- wall fixing set<br />

- chrome-plated air vent and drain cock<br />

code height length colour conn. type<br />

ORDERING CODE : TSDW. 121 050. 011 /18 /SP<br />

Standard delivery<br />

- brushed stainless steel<br />

- central connection 18 underneath<br />

- wall fixing set<br />

- chrome-plated air vent and drain cock<br />

L<br />

L<br />

L<br />

L<br />

H<br />

H<br />

H<br />

H<br />

Output measured in accordance with EN442,<br />

at a water temperature of 75/65 and a room<br />

temperature of 20°C (ΔT=50).<br />

Connection sets & valves<br />

Page<br />

203<br />

Technical info 239<br />

Correction factors 242<br />

Product descriptions 253<br />

Colours 263<br />

77<br />

<strong>Taboe</strong> Sani


78<br />

Options<br />

Electro heating<br />

Pressure relief valve<br />

Adaptor<br />

CODE H type WATTS L<br />

radiator<br />

9096.12 121 single 900 51.5<br />

9096.13 121 double 1200 66.0<br />

9096.13 182 single 1200 66.0<br />

9096.14 182 double 1500 82.0<br />

Electro heating element with<br />

infra-red operation<br />

Only for <strong>Taboe</strong> Sani Single<br />

- Finish: white ABS<br />

- Transmittion range: ± 6 m<br />

in all directions<br />

- Receiver has to be placed<br />

at the back of the radiator.<br />

- Insulation Class 1<br />

20<br />

25<br />

15<br />

30<br />

10<br />

°C<br />

5<br />

CODE WATTS L<br />

9096.510 600 47<br />

9096.520 900 68<br />

Connection electric element<br />

- Fit the electric heating element vertically in<br />

the socket 1 or 8. The pressure release valve<br />

which is included should be fitted into socket<br />

4 or 5, (3 bar).<br />

- Do not switch the radiator on before filling it<br />

completely with water.<br />

- Top up with water after the first total heating<br />

up of the radiator.<br />

For more information see Technical info.<br />

L<br />

L<br />

T-piece for mixed application<br />

T-piece<br />

CO D E co l o u r<br />

TPCE.004.009 chrome<br />

TPCE.004.XXX 201 up to 233<br />

301 up to 333<br />

fill in colour code<br />

Insert pipe for top end connection<br />

L<br />

Will be delivered without surcharge if the top<br />

end connection code is indicated 45 or 54<br />

instead of 18.<br />

CO D E H r a d i a to r L<br />

9097.1100 121 110<br />

9097.1660 182 166<br />

G 1/2"<br />

2.7<br />

G 1/2"<br />

1.45<br />

0.9<br />

insert<br />

pipe<br />

�<br />

�<br />

�<br />

Use PFTE<br />

or flax


<strong>Taboe</strong> Sani<br />

79


80<br />

2<br />

1<br />

1. <strong>Taboe</strong><br />

2. <strong>Taboe</strong> Freestanding


<strong>Taboe</strong><br />

81


82<br />

<strong>Taboe</strong><br />

Dimensions<br />

TABW_<strong>Taboe</strong> Wall<br />

- for central heating<br />

- 100% electric<br />

- mixed<br />

11.5<br />

8.5<br />

TABF_<strong>Taboe</strong> Free-standing<br />

- with electric element<br />

H<br />

ø 1.5<br />

ø 2.5<br />

44.4<br />

3°<br />

38 39<br />

10<br />

10 44.4<br />

8.4<br />

Connections<br />

Standard connection<br />

Code 18<br />

Connection 18 or 81<br />

To the floor:<br />

To the wall:<br />

7.2<br />

1 8<br />

10<br />

7.2 10<br />

With electric element<br />

Fitted with an on/off switch: order wall model<br />

EL (electric).<br />

Fitted with thermostatic: order wall mounted<br />

model central heating + element. See page 78<br />

Mixed<br />

Ordering code: standard code 18.<br />

Order an electric element and T-piece.<br />

- Fit the T-piece together with the electric heating<br />

element for connection to the central<br />

heating wet system.<br />

- Never isolate the radiator from the expansion<br />

system, in other words never cut off the<br />

return of the radiator.<br />

2.5 cm<br />

7.2 cm<br />

10 cm<br />

Range<br />

TABW_<strong>Taboe</strong> Wall<br />

44.4<br />

125<br />

TABF_<strong>Taboe</strong> Free-standing<br />

125<br />

180<br />

180


Outputs<br />

<strong>Taboe</strong> wall mounted<br />

model_C.H.<br />

H L 044<br />

125 75/65/20 432<br />

90/70/20 546<br />

180 75/65/20 629<br />

90/70/20 792<br />

<strong>Taboe</strong> wall mounted<br />

model_EL<br />

H L 044<br />

125 WATTS 600<br />

180 WATTS<br />

900<br />

<strong>Taboe</strong> wall mounted<br />

model_MX<br />

H L 044<br />

125 WATTS 600<br />

180 WATTS<br />

900<br />

<strong>Taboe</strong> Freestanding_EL<br />

H L 044<br />

125 WATTS 600<br />

180 WATTS<br />

900<br />

code height length colour conn.<br />

ORDERING CODE : TABW. 125 044. XXX /18<br />

Standard delivery<br />

- 2 wall fixing brackets in the same colour<br />

as the radiator<br />

- invisible inside sockets 1/2” at the<br />

bottom end of the collector tubes<br />

- air venting via the round balls at the top<br />

end of the collector tubes<br />

code height length colour conn.<br />

ORDERING CODE : TABW. 125 044. XXX /EL<br />

Standard delivery<br />

- Supplied completely fitted and filled, including<br />

electric heating element with a cable of<br />

2.5 m and a plug with an on / off switch<br />

- 2 wall fixing brackets in the same colour as<br />

the radiator<br />

code height length colour conn.<br />

ORDERING CODE : TABW. 125 044. XXX /MX<br />

Standard delivery<br />

- 2 wall fixing brackets in the same colour<br />

as the radiator<br />

- invisible inside sockets 1/2” at the<br />

bottom end of the collector tubes<br />

- electric element with thermostat Class I<br />

Length wire: 1.2 m<br />

- T-piece in the same colour as the radiator<br />

- air venting via the round balls at the top<br />

end of the collector tubes<br />

code height length colour conn.<br />

ORDERING CODE : TABF. 125 044. XXX /EL<br />

Standard delivery<br />

- Supplied completely fitted and filled,<br />

inclusive electric heating element with a<br />

cable of 2.5 m and a plug with an on / off<br />

switch<br />

- foot in the same colour as the radiator<br />

H<br />

H<br />

H<br />

H<br />

44<br />

44<br />

44<br />

44<br />

Output measured in accordance with EN442,<br />

at a water temperature of 75/65 and a room<br />

temperature of 20°C (ΔT=50).<br />

83<br />

<strong>Taboe</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!