949 Respiratory System Scintigraphy36) Stomach visualization on a ventilation scan performedusing 99m Tc DTPA aerosol indicates:a. there was turbulent air flowb. the nebulizer is not functioning properlyc. the patient is a smokerd. the patient swallowed some of the radiopharmaceuticale. the patient has a right to left cardiac shunt37) The radiopharmaceutical used for ventilation scanningwith the highest administered dose is:a. 133 Xe gasb. 99m Tc DTPA aerosolc. 127 Xe gasd. 81m Kre. 99m Tc MAA38) Only half of the administered dose of 99m Tc DTPAaerosol is delivered to the patient.a. trueb. false39) Patient education prior to a ventilation scan may:a. improve image qualityb. relax the patient and thereby speed washoutc. reduce the radiation dose to the technologistd. all of the abovee. a and c only40) The liver may be seen in the washout phase of aventilation study because:a. 99m Tc DTPA aerosol was swallowed and then enteredthe bloodstream via the stomachb. 133 Xe gas is fat solublec. particle size is too smalld. air flow is turbulent