10.07.2015 Views

Internal Modular OEM Kit SPDs Data Sheet - Surgelogic

Internal Modular OEM Kit SPDs Data Sheet - Surgelogic

Internal Modular OEM Kit SPDs Data Sheet - Surgelogic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Internal</strong> <strong>Modular</strong><strong>OEM</strong> <strong>Kit</strong> <strong>SPDs</strong>Square D TM <strong>Internal</strong>ly MountedSurge Protective DevicesSquare D TM brand <strong>Surgelogic</strong> TM internal modular <strong>OEM</strong> kitSurge Protective Devices (<strong>SPDs</strong>) deliver specification gradeperformance for service entrance or critical branch panelapplications. This multi-phase system provides suppression forall critical modes inside electrical equipment. The short leadlengths deliver superior SPD performance.TM


<strong>Internal</strong> <strong>Modular</strong><strong>OEM</strong> <strong>Kit</strong> <strong>SPDs</strong>Features (continued)03Diagnostic Displayinches[mm]<strong>Internal</strong> <strong>SPDs</strong>3.94[100]3.45[87.6]0.25[6.3]0.25[6.3]5.12[130]4.63[117.6]4X 6-32 PEM STUDSurge Protective Device0.89[22.6]Mounting HoleLocations6.60[167.6]1.22 1.32[31] [33.5]inches[mm]0.49[12.4]PerformanceSurge Current Rating per Phase Up to 240kAShort Circuit Current Rating200kAModes of Protection 10FusingIndividually fused MOVsThermal FusingYesOvercurrent FusingYesFilteringYesOperating Frequency50/60 HzMechanical DescriptionConnection Method #10-#2 AWG TerminalsMounting Method/Circuit TypeParallelOperating Altitude Sea Level-12,000’ (3,658 m)Storage Temperature -40˚ F (-40˚ C) to 149˚ F (65˚ C)Operating Temp. -4˚ F (-20˚ C) to 149˚ F (65˚ C)LCD Operating Temp. 32˚ F (0˚ C) to 149˚ F (65˚ C)Operating Humidity 0 to 95% non-condensing2.39[60.7]5.69[144.5]GROUND9.86[250.4]Mounting Stand-offs 3X 1/4-20NEUTRAL6.13[155.7]5.33[135.3]0.78[19.8]3.65[92.7]DiagnosticsPush to test diagnostic switches, red and greenstatus LEDs per phase (internal redundant statusLEDs are green), module status LEDs per mode,dry contacts, audible alarm with disable switch,surge counter. Standard Diagnostic Cable Lengthis 36in (91.44cm).Options• Remote monitor• Diagnostic cable kits with varying lengths (seelast page)Safety and PerformancecURus per UL1449 3rd Ed. Type 2 SPD, UL 12835th Ed., and CAN/CSA C22.2 No. 8-M1986.Complies with UL 96A 12th Ed. Master Labelrequirements for Lightning Protection SystemsSchneider Electric USA, Inc. 1751 S. 4800 W., Salt Lake City, UT 84104, USA Telephone: (801)-977-9009 Fax: (801)-977-0200 www.surgelogic.com© 2011 Schneider Electric. All rights reserved.Document Number 9990-0103AOctober 2011 bw


<strong>Internal</strong> <strong>Modular</strong><strong>OEM</strong> <strong>Kit</strong> <strong>SPDs</strong>Specifications04VoltageSurgeCurrent perPhaseProtection Configuration Model Number MCOV I nL-N L-G L-L N-GVPRModes of120/240V 120kA 6 1 Ø, 3-wire+G TVS1IMA12O 150V 20kA 700V 700V 1200V 700V208Y/120V • 120kA 10 3 Ø, Wye, 4-wire+G TVS2IMA12O 150V 20kA 700V 700V 1200V 700V480Y/277V 120kA 10 3 Ø, Wye, 4-wire+G TVS4IMA12O 320V 20kA 1200V 1200V 2000V 1200V600Y/347V 120kA 10 3 Ø, Wye, 4-wire+G TVS8IMA12O 420V 20kA 1500V 1500V 2500V 1500V120/240V 160kA 6 1 Ø, 3-wire+G TVS1IMA16O 150V 20kA 700V 700V 1200V 700V208Y/120V • 160kA 10 3 Ø, Wye, 4-wire+G TVS2IMA16O 150V 20kA 700V 700V 1200V 700V480Y/277V 160kA 10 3 Ø, Wye, 4-wire+G TVS4IMA16O 320V 20kA 1200V 1200V 2000V 1200V600Y/347V 160kA 10 3 Ø, Wye, 4-wire+G TVS8IMA16O 420V 20kA 1500V 1500V 2500V 1500V120/240V 240kA 6 1 Ø, 3-wire+G TVS1IMA24O 150V 20kA 700V 700V 1200V 700V208Y/120V • 240kA 10 3 Ø, Wye, 4-wire+G TVS2IMA24O 150V 20kA 700V 700V 1200V 700V480Y/277V 240kA 10 3 Ø, Wye, 4-wire+G TVS4IMA24O 320V 20kA 1200V 1200V 2000V 1200V600Y/347V 240kA 10 3 Ø, Wye, 4-wire+G TVS8IMA24O 420V 20kA 1500V 1500V 2500V 1500V• 208Y/120 series also applies to the following voltage 220Y/127 480Y/277 series also applies to the following voltages 380Y/220, 400Y/230, and 415Y/240<strong>OEM</strong> kit comes with 36 inches of cableVoltageSurgeCurrentperPhaseModes ofProtectionConfigurationNumber MCOV I nL-N H-N L-G H-G L-L H-L N-GVPRModel240/120HLD 120kA 10 3 Ø, HLD*, 4-wire+G TVS3IMA12O 150V 20kA 700V 1200V 1200V 1000V 1200V 1500V 700V240/120HLD 160kA 10 3 Ø, HLD*, 4-wire+G TVS3IMA16O 150V 20kA 700V 1200V 1200V 1000V 1200V 1500V 700V240/120HLD 240kA 10 3 Ø, HLD*, 4-wire+G TVS3IMA24O 150V 20kA 700V 1200V 1200V 1000V 1200V 1500V 700VModel numbers not recognized as line items in Schneider Electric ordering system until a suffix code is applied*HLD = High-leg deltaSPD OPTIONSTVS12RMUTVS19PCKTVS36PCKTVS60PCKTVS192PCKRemote Monitor19 inch (48.26 cm) cable kit36 inch (91.44 cm) cable kit60 inch (152.40 cm) cable kit192 inch (487.68 cm) cable kitSquare D and <strong>Surgelogic</strong> are trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. Other marks used herin may be theproperty of their respective owners.Schneider Electric USA, Inc. 1751 S. 4800 W., Salt Lake City, UT 84104, USA Telephone: (801)-977-9009 Fax: (801)-977-0200 www.surgelogic.com© 2011 Schneider Electric. All rights reserved.Document Number 9990-0103AOctober 2011 bw

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!