C300 D5 50 Diesel Our energy working for you.⢠Fuel consumption ...
C300 D5 50 Diesel Our energy working for you.⢠Fuel consumption ...
C300 D5 50 Diesel Our energy working for you.⢠Fuel consumption ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Model:Frequency:<strong>Fuel</strong> Type:<strong>C300</strong> <strong>D5</strong><strong>50</strong><strong>Diesel</strong>» Generator set data sheet300 kVA Standby<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.Spec sheet:Noise data sheet (Open/enclosed):Airflow data sheet:Derate data sheet (Open/enclosed):Transient data sheet:SS8-CPGKN<strong>D5</strong>0-OS5<strong>50</strong> / N<strong>D5</strong>0-CS5<strong>50</strong>AF<strong>50</strong>-5<strong>50</strong>D<strong>D5</strong>0-OS5<strong>50</strong> / D<strong>D5</strong>0-CS5<strong>50</strong>T<strong>D5</strong>0-5<strong>50</strong><strong>Fuel</strong> <strong>consumption</strong>RatingsLoadUS gphL/hrEngineEngine manufacturerEngine modelConfigurationAspirationGross engine power output, kWmBMEP at set rated load, kPaBore, mmStroke, mmRated speed, rpmPiston speed, m/sCompression ratioLube oil capacity, LOverspeed limit, rpmRegenerative power, kWGovernor typeStarting voltage<strong>Fuel</strong> flowMaximum fuel flow, L/hrMaximum fuel inlet restriction, mm HgMaximum fuel inlet temperature (°C)StandbyPrimekVA (kW)kVA (kW)300 (240)275 (220)1/4 1/2 3/4 Full 1/4 1/2 3/4 Full4.0 7.2 11.0 15.0 3.4 6.2 9.2 12.618 33 <strong>50</strong> 68 16 28 42 57Standby ratingPrime ratingCumminsQSL9 G54 Cycle; In-line; 6 Cylinder <strong>Diesel</strong>Turbo Charged and Charge Air Cooled310268278524131141451<strong>50</strong>07.216.8:126.51800 ±<strong>50</strong>47Electronic24 Volts DC16520370AirCombustion air, m 3 /minMaximum air cleaner restriction, kPa20.36.218.7©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generationand Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of CumminsPower Generation. Other company, product, or service names may be trademarks or service marks of others.
ExhaustExhaust gas flow at set rated load, m 3 /minExhaust gas temperature, ° CMaximum exhaust back pressure, kPaStandard set-mounted radiator coolingAmbient design, ° CFan load, KW mCoolant capacity (with radiator), LCooling system air flow, m3/min @ 12.7mmH2OTotal heat rejection, BTU/minMaximum cooling air flow static restriction mmH2OStandby rating5356010.2<strong>50</strong>10157.931019019.1Prime rating44.9<strong>50</strong>08415Open set derating factors kVA (kW)Note: Standard open genset options running at 400V, 1<strong>50</strong>m above sea level. For enclosed product derates, please refer to datasheet - D<strong>D5</strong>0-CS5<strong>50</strong>.Standby27°<strong>C300</strong> (240)40°C45°<strong>C300</strong> (240) 300 (240)<strong>50</strong>°C 55°<strong>C300</strong> (240)291.3 (233)Prime272.8 (218.2)272.8 (218.2)272.8 (218.2)272.8 (218.2)257.5 (206)Weights*Unit dry weight kgsUnit wet weight kgs* Weights represent a set with standard features. See outline drawing <strong>for</strong> weights of other configurationsDimensionsGenset outlineOpen setOpenEnclosed2518409525704734LengthWidthHeightStandard open set dimensions 354911001928Enclosed set standard dimensions42541424 2215Enclosed setOutlines are <strong>for</strong> illustrative purposes only. Please refer to the genset outline drawing <strong>for</strong> an exact representation of this model.©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generationand Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of CumminsPower Generation. Other company, product, or service names may be trademarks or service marks of others.
Alternator dataFeature code Connection 1 Temp rise degrees CB324Wye, 3 Phase 125/105CDuty 2S/PAlternatorHC4DVoltage380-440VRatings definitionsEmergency Standby Power (ESP) Limited-Time running PowerApplicable <strong>for</strong> supplying power to Applicable <strong>for</strong> supplying power to avarying electrical load <strong>for</strong> the constant electrical load <strong>for</strong> limitedduration of power interruption of a hours. Limited Time Runningreliable utility source. Emergency Power (LTP) is in accordance withStandby Power (ESP) is in ISO 8528.accordance with ISO 8528. <strong>Fuel</strong>Stop power in accordance with ISO3046, AS 2789, DIN 6271 and BS5514.Prime Power (PRP):Applicable <strong>for</strong> supplying power tovarying electrical load <strong>for</strong> unlimitedhours. Prime Power (PRP) is inaccordance with ISO 8528. Tenpercent overload capability isavailable in accordance with ISO3046, AS 2789, DIN 6271 and BS5514.Base Load (Continuous) PowerApplicable <strong>for</strong> supplying powercontinuously to a constant electricalload <strong>for</strong> unlimited hours.Continuous Power (COP) inaccordance with ISO 8528, ISO3046, AS 2789, DIN 6271 and BS5514.Formulas <strong>for</strong> calculating full load currents:Three phase outputkWx1000Voltagex1. 73x0.8Single phase outputkWxSingleP haseFactor x1000VoltageSee <strong>you</strong>r distributor <strong>for</strong> more in<strong>for</strong>mation.Cummins Power GenerationManston Park, Columbus AvenueManston, RamsgateKent CT12 5BF, UKTelephone: +44 (0) 1843 25<strong>50</strong>00Fax: +44 (0) 1843 255902E-Mail: cpg.uk@cummins.comWeb: www.cumminspower.com©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generationand Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of CumminsPower Generation. Other company, product, or service names may be trademarks or service marks of others.