10.07.2015 Views

C300 D5 50 Diesel Our energy working for you.™ Fuel consumption ...

C300 D5 50 Diesel Our energy working for you.™ Fuel consumption ...

C300 D5 50 Diesel Our energy working for you.™ Fuel consumption ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Model:Frequency:<strong>Fuel</strong> Type:<strong>C300</strong> <strong>D5</strong><strong>50</strong><strong>Diesel</strong>» Generator set data sheet300 kVA Standby<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.Spec sheet:Noise data sheet (Open/enclosed):Airflow data sheet:Derate data sheet (Open/enclosed):Transient data sheet:SS8-CPGKN<strong>D5</strong>0-OS5<strong>50</strong> / N<strong>D5</strong>0-CS5<strong>50</strong>AF<strong>50</strong>-5<strong>50</strong>D<strong>D5</strong>0-OS5<strong>50</strong> / D<strong>D5</strong>0-CS5<strong>50</strong>T<strong>D5</strong>0-5<strong>50</strong><strong>Fuel</strong> <strong>consumption</strong>RatingsLoadUS gphL/hrEngineEngine manufacturerEngine modelConfigurationAspirationGross engine power output, kWmBMEP at set rated load, kPaBore, mmStroke, mmRated speed, rpmPiston speed, m/sCompression ratioLube oil capacity, LOverspeed limit, rpmRegenerative power, kWGovernor typeStarting voltage<strong>Fuel</strong> flowMaximum fuel flow, L/hrMaximum fuel inlet restriction, mm HgMaximum fuel inlet temperature (°C)StandbyPrimekVA (kW)kVA (kW)300 (240)275 (220)1/4 1/2 3/4 Full 1/4 1/2 3/4 Full4.0 7.2 11.0 15.0 3.4 6.2 9.2 12.618 33 <strong>50</strong> 68 16 28 42 57Standby ratingPrime ratingCumminsQSL9 G54 Cycle; In-line; 6 Cylinder <strong>Diesel</strong>Turbo Charged and Charge Air Cooled310268278524131141451<strong>50</strong>07.216.8:126.51800 ±<strong>50</strong>47Electronic24 Volts DC16520370AirCombustion air, m 3 /minMaximum air cleaner restriction, kPa20.36.218.7©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generationand Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of CumminsPower Generation. Other company, product, or service names may be trademarks or service marks of others.


ExhaustExhaust gas flow at set rated load, m 3 /minExhaust gas temperature, ° CMaximum exhaust back pressure, kPaStandard set-mounted radiator coolingAmbient design, ° CFan load, KW mCoolant capacity (with radiator), LCooling system air flow, m3/min @ 12.7mmH2OTotal heat rejection, BTU/minMaximum cooling air flow static restriction mmH2OStandby rating5356010.2<strong>50</strong>10157.931019019.1Prime rating44.9<strong>50</strong>08415Open set derating factors kVA (kW)Note: Standard open genset options running at 400V, 1<strong>50</strong>m above sea level. For enclosed product derates, please refer to datasheet - D<strong>D5</strong>0-CS5<strong>50</strong>.Standby27°<strong>C300</strong> (240)40°C45°<strong>C300</strong> (240) 300 (240)<strong>50</strong>°C 55°<strong>C300</strong> (240)291.3 (233)Prime272.8 (218.2)272.8 (218.2)272.8 (218.2)272.8 (218.2)257.5 (206)Weights*Unit dry weight kgsUnit wet weight kgs* Weights represent a set with standard features. See outline drawing <strong>for</strong> weights of other configurationsDimensionsGenset outlineOpen setOpenEnclosed2518409525704734LengthWidthHeightStandard open set dimensions 354911001928Enclosed set standard dimensions42541424 2215Enclosed setOutlines are <strong>for</strong> illustrative purposes only. Please refer to the genset outline drawing <strong>for</strong> an exact representation of this model.©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generationand Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of CumminsPower Generation. Other company, product, or service names may be trademarks or service marks of others.


Alternator dataFeature code Connection 1 Temp rise degrees CB324Wye, 3 Phase 125/105CDuty 2S/PAlternatorHC4DVoltage380-440VRatings definitionsEmergency Standby Power (ESP) Limited-Time running PowerApplicable <strong>for</strong> supplying power to Applicable <strong>for</strong> supplying power to avarying electrical load <strong>for</strong> the constant electrical load <strong>for</strong> limitedduration of power interruption of a hours. Limited Time Runningreliable utility source. Emergency Power (LTP) is in accordance withStandby Power (ESP) is in ISO 8528.accordance with ISO 8528. <strong>Fuel</strong>Stop power in accordance with ISO3046, AS 2789, DIN 6271 and BS5514.Prime Power (PRP):Applicable <strong>for</strong> supplying power tovarying electrical load <strong>for</strong> unlimitedhours. Prime Power (PRP) is inaccordance with ISO 8528. Tenpercent overload capability isavailable in accordance with ISO3046, AS 2789, DIN 6271 and BS5514.Base Load (Continuous) PowerApplicable <strong>for</strong> supplying powercontinuously to a constant electricalload <strong>for</strong> unlimited hours.Continuous Power (COP) inaccordance with ISO 8528, ISO3046, AS 2789, DIN 6271 and BS5514.Formulas <strong>for</strong> calculating full load currents:Three phase outputkWx1000Voltagex1. 73x0.8Single phase outputkWxSingleP haseFactor x1000VoltageSee <strong>you</strong>r distributor <strong>for</strong> more in<strong>for</strong>mation.Cummins Power GenerationManston Park, Columbus AvenueManston, RamsgateKent CT12 5BF, UKTelephone: +44 (0) 1843 25<strong>50</strong>00Fax: +44 (0) 1843 255902E-Mail: cpg.uk@cummins.comWeb: www.cumminspower.com©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generationand Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of CumminsPower Generation. Other company, product, or service names may be trademarks or service marks of others.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!