H. The Contractor is solely responsible for installing and extracting the shoring in amanner that will not disturb the line, grade, backfill compaction, or operation <strong>of</strong> theutility being installed or adjacent utilities and facilities.I. Ductile iron pipe and fittings shall be prepared, sealed and cut in accordance withthe manufacturer's recommended procedures.J. Place pipe that is to be bedded in concrete cradle or encased in concrete in properposition on temporary supports. When necessary, rigidly anchor or weight the pipeto prevent flotation as concrete is placed. Place concrete for cradles, arches orencasement uniformly on each side <strong>of</strong> the pipe and deposit at approximately itsfinal position. Concrete placed beneath the pipe shall be sufficiently workable sothat the entire space beneath the pipe can be filled without excessive vibration.K. The minimum horizontal centerline to center line separation between sewer andwater mains or laterals shall be ten feet zero inches (10'-0") to conform to sewerseparation guidelines. Vertical clearances shall be as directed or shown on theproject plans. In any case, a minimum clear space separation <strong>of</strong> twelve (12) inchesshall be provided, with sewer line on lower level than water line.L. At the end <strong>of</strong> each workday, all open ends <strong>of</strong> pipe installed shall be plugged to thesatisfaction <strong>of</strong> the <strong>City</strong>'s Project Inspector.3.05 SEWERSLIPLININGA. IntentIt is the intent <strong>of</strong> this portion <strong>of</strong> the Specification to provide for rehabilitating sewerlines via the installation <strong>of</strong> a fiberglass, high density polyethylene (HDPE) orpolyvinyl chloride (PVC) sliplining pipe.B. Scope <strong>of</strong> WorkShall be per the design submittal and the contract documents.C. Materials1. Fiberglass pipe shall be centrihgally cast with glass fiber reinforcement in a curedthermosetting resin manufactured in accordance with ASTM D3262, cellclassification Type 1, Liner 2, Grade 3. Pipe stiffness shall meet the designrequirements in the following Section 4.2. Fiberglass liner shall be shown by teststo be resistant to long-term corrosion. Testing shall be performed in accordancewith ASTM D368 1 using 1 .ON sulfmc acid for sanitary sewage, and ASTM C58 1for industrial sewage.2. PVC pipe shall have a minimum cell classification <strong>of</strong> 12364 B or C as defined inASTM D1784. Pipe shall be closed pr<strong>of</strong>ile. The joint shall be designed so thatSection <strong>02720</strong> - 15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!