REPAIR PARTSHUM-XXXX High CapacityFlow-Thru Bypass and Fan-Powered HumidifierHUM-FPHUM-LFTBPHUM-SFTBPThis manual is to be used by qualified technicians only.Made in the USA by:Goodman Manufacturing Company, L.P.2550 North Loop West, Suite 400Houston Texas 77092www.goodmanmfg.<strong>com</strong>www.amana-hac.<strong>com</strong>RP-344AOctober 2006This manual replaces RP-344.Copyright © 2005-2006 Goodman Manufacturing Company, L.P.


Important InformationIndexFunctional <strong>Parts</strong> ListIllustration and <strong>Parts</strong>......................................................................................................................................................................................................34 - 9Views shown are for parts illustrations only, not servicing proceduresRev. A: Placed models on separate pages for easier viewing.Text Codes:AR - As RequiredNA - Not AvailableNS - Not Shown00000000 - See NoteQTY - Quantity Example (QTY 3) (If Quantity not shown, Quantity = 1)M - Model Example (M1) (If M Code not shown, then part is used on all Models)Expanded Model Nomenclature:ExampleM1 - Model#1M2 - Model#2M3 - Model#3Goodman Manufacturing Company, L.P. is not responsible for personal injury or property damage resulting fromimproper service. Review all service information before beginning repairs.Warranty service must be performed by an authorized technician, using authorized factory parts. If service isrequired after the warranty expires, Goodman Manufacturing Company, L.P. also re<strong>com</strong>mends contacting anauthorized technician and using authorized factory parts.Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specificationsor designs without notice or without incurring obligations. Goodman® brand products are proudly made in theUSA.For assistance within the U.S.A. contact:Consumer Affairs DepartmentGoodman Manufacturing Company, L.P.7401 Security WayHouston, Texas 77040877-254-4729-Telephone713-863-2382-FacsimileFor assistance outside the U.S.A. contact:International DivisionGoodman Company, Manufacturing L.P. Company, L.P.7401 Security WayHouston, Texas 77040713-861-2500-Telephone713-863-2382-FacsimileCopyright © 2005-2006 Goodman Manufacturing Company, L.P.2RP-344A


Functional <strong>Parts</strong>PartNo:Description:HUM-1721048HUM-1106030HUM-0814148HUM-0814008MOTOR, FAN (M1)ORIFICE (.020) DIAMETER (M2)SOLENOID VALVE, 24V (M1)TRANSFORMER, 24V (M2)SPECIAL PARTSIO-634INSTALLATION INSTRUCTIONSRP-344AREPAIR PARTS MANUALExpanded Model NomenclatureM1 - HUM-FPM2 - HUM-LFTBPM3 - HUM-SFTBP3 RP-344A


Fan Powered Humidifier (HUM-FP)RP-344A4


Fan Powered Humidifier (HUM-FP)Ref.No:PartNo:Description:Ref.No:PartNo:Description:Image 1:11HUM-1730091MOUNTING BASE (M1)2131415161718191101111121131141151161171NSNSHUM-0602055HUM-1317091HUM-1730089HUM-1725051HUM-0641169HUM-1318080HUM-0814148HUM-HSTATHUM-1128005HUM-1106030HUM-1319051HUM-0811123HUM-0811122HUM-1721048HUM-0431034HUM-1730092HUM-A50HUM-0803041DRIP TRAY (M1)WICK (M1)SIDE PIECE W/O COLLAR (M1)EVAPORATOR PAD, 12 PK (INCLUDES KEY) (M1)COVER W/VENTS (M1)BLADE, FAN, 10" DIAMETER (M1)SOLENOID VALVE, 24V (M1)HUMIDSTAT, 24V W/LOGOS (M1)SADDLE VALVE ASSEMBLY (M1)ORIFICE (.020) DIAMETER (M1)INLINE FILTER (M1)CORD, POWER SUPPLY (M1)2 PIECE CONNECTOR ASSEMBLY (M1)MOTOR, FAN (M1)RELAY, ISOLATION (M1)SHROUD, FAN (M1)RELAY, CURRENT SENSING (M1)SCREW, COVER ATTACH (M1)NS HUM-1175028 TUBE, FILL (M1)Expanded Model NomenclatureM1 - HUM-FPM2 - HUM-LFTBPM3 - HUM-SFTBP5 RP-344A


Large Flow-Thru ByPass Humidifier (HUM-LFTBP)RP-344A6


Large Flow-Thru ByPass Humidifier (HUM-LFTBP)Ref.No:PartNo:Description:Ref.No:PartNo:Description:Image 1:11HUM-1730091MOUNTING BASE (M2)21314151618191101111121201211NSHUM-0602055HUM-1317091HUM-1730089HUM-1725051HUM-0641170HUM-0814148HUM-HSTATHUM-1128005HUM-1106030HUM-1319051HUM-0814008HUM-1730124HUM-A50DRIP TRAY (M2)WICK (M2)SIDE PIECE W/O COLLAR (M2)EVAPORATOR PAD, 12 PK (INCLUDES KEY) (M2)COVER (M2)SOLENOID VALVE, 24V (M2)HUMIDSTAT, 24V W/LOGOS (M2)SADDLE VALVE ASSEMBLY (M2)ORIFICE (.020) DIAMETER (M2)INLINE FILTER (M2)TRANSFORMER, 24V (M2)PANEL, DAMPER SIDE (M2)RELAY, CURRENT SENSING (M2)NS HUM-0803041 SCREW, COVER ATTACH (M2)NS HUM-1175028 TUBE, FILL (M2)Expanded Model NomenclatureM1 - HUM-FPM2 - HUM-LFTBPM3 - HUM-SFTBP7 RP-344A


Small Flow-Thru ByPass Humidifier (HUM-SFTBP)RP-344A8


Small Flow-Thru ByPass Humidifier (HUM-SFTBP)Ref.No:PartNo:Description:Ref.No:PartNo:Description:Image 1:11HUM-1730094MOUNTING BASE (M3)21314151618191101111121201211NSHUM-0602055HUM-1317091HUM-1730089HUM-1725052HUM-0641171HUM-0814148HUM-HSTATHUM-1128005HUM-1106030HUM-1319051HUM-0814008HUM-1730124HUM-A50DRIP TRAY (M3)WICK (M3)SIDE PIECE W/O COLLAR (M3)EVAPORATOR PAD, 12 PK (INCLUDES KEY) (M3)COVER (M3)SOLENOID VALVE, 24V (M3)HUMIDSTAT, 24V W/LOGOS (M3)SADDLE VALVE ASSEMBLY (M3)ORIFICE (.020) DIAMETER (M3)INLINE FILTER (M3)TRANSFORMER, 24V (M3)PANEL, DAMPER SIDE (M3)RELAY, CURRENT SENSING (M3)NS HUM-0803041 SCREW, COVER ATTACH (M3)NS HUM-1175028 TUBE, FILL (M3)Expanded Model NomenclatureM1 - HUM-FPM2 - HUM-LFTBPM3 - HUM-SFTBP9 RP-344A