Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP)<strong>SAFETY</strong> <strong>DATA</strong> <strong>SHEET</strong>Energy saver F6 500ml1.Identification of the preparation and of the companyProduct name: Energy saver F6 500mlCode : 60216Head Office: Cookson ElectronicsForsyth RoadSheerwaterWokingSurreyEnglandGU21 5RZTel: +44(0)1483 758400Fax: +44(0)1483 728837Manufacturer: Cookson ElectronicsKoenendelseweg 295222 BG's-HertogenboschThe NetherlandsTel: +31 73 6280 111Fax: +31 73 6219 2832Contact personMaterial usesClassification:shosken@cooksonelectronics.com: Heat-transfer medium.Hazards identificationThe product is not classified as dangerous according to Directive 1999/45/EC and its amendments.Effects and symptomsSkin contactEye contactToxicity data:Not classified.Slightly hazardous by the following route of exposure: of skin contact (irritant).Slightly hazardous by the following route of exposure: of eye contact (irritant).Not available.See section 11 for more detailed information on health effects and symptoms.3Composition/information on ingredientsSubstance/preparation:PreparationOccupational exposure limits, if available, are listed in section 8.The classifications listed, indecate the potential hazards of the ingredients4.First-aid measuresInhalationIngestionSkin contactEye contactFirst-aid measuresProtection of first-aidersNotes to physician:::::Get medical attention if symptoms occur. If unconscious, place in recovery positionand get medical attention immediately. Maintain an open airway.Wash out mouth with water. Do not induce vomiting unless directed to do so bymedical personnel. If vomiting occurs, the head should be kept low so that vomitdoes not enter the lungs. Get medical attention if symptoms occur.Flush contaminated skin with plenty of water. Get medical attention if symptomsoccur.Immediately flush eyes with plenty of water, occasionally lifting the upper and lowereyelids. Check for and remove any contact lenses. Continue to rinse for at least 10minutes. Get medical attention if irritation occurs.: No action shall be taken involving any personal risk or without suitable training.In case of inhalation of decomposition products in a fire, symptoms may be delayed.The exposed person may need to be kept under medical surveillance for 48 hours.See section 11 for more detailed information on health effects and symptoms.Date of issue : 14/06/2011. 1/6


Energy saver F6 500ml5.Fire-fighting measuresExtinguishing mediaSuitable :Not suitable :Special exposure hazardsHazardous combustionproductsSpecial protectiveequipment for fire-fighters:::Use an extinguishing agent suitable for the surrounding fire.None known.In a fire or if heated, a pressure increase will occur and the container may burst.Promptly isolate the scene by removing all persons from the vicinity of the incident ifthere is a fire. No action shall be taken involving any personal risk or without suitabletraining.Decomposition products may include the following materials:carbon dioxidecarbon monoxidenitrogen oxidesmetal oxide/oxidesFire-fighters should wear appropriate protective equipment and self-containedbreathing apparatus (SCBA) with a full face-piece operated in positive pressuremode.6. Accidental release measuresPersonal precautionsEnvironmental precautionsLarge spill :Small spill :7.Handling and storage: Avoid breathing vapour or mist. Provide adequate ventilation. Put on appropriatepersonal protective equipment (see section 8).:Avoid dispersal of spilt material and runoff and contact with soil, waterways, drainsand sewers. Inform the relevant authorities if the product has caused environmentalpollution (sewers, waterways, soil or air).Prevent entry into sewers, water courses, basements or confined areas. Use a waterrinse for final clean-up. Note: see section 1 for emergency contact information andsection 13 for waste disposal.Use a water rinse for final clean-up. Dispose of via a licensed waste disposalcontractor.HandlingStoragePackaging materialsRecommendedCzech Republic - Storagecode::Put on appropriate personal protective equipment (see section 8). Avoid breathingvapour or mist. Do not reuse container.Do not store in unlabelled containers. Use appropriate containment to avoidenvironmental contamination.: Use original container.: III8. Exposure controls/personal protectionExposure limit valuesIngredient nameEuropeNo exposure limit value known.Occupational exposure limitsSwedenNo exposure limit value known.DenmarkNo exposure limit value known.Norwaypropane-1,2-diol Arbeidstilsynet (Norway, 11/2007).TWA: 79 mg/m³ 8 hour(s).TWA: 25 ppm 8 hour(s).FranceNo exposure limit value known.Date of issue : 14/06/2011. 2/6


Energy saver F6 500ml8. Exposure controls/personal protectionNetherlandsNo exposure limit value known.GermanyNo exposure limit value known.FinlandNo exposure limit value known.United Kingdom (UK)propane-1,2-diol EH40/2005 WELs (United Kingdom (UK), 8/2007).TWA: 10 mg/m³ 8 hour(s). Form: ParticulateTWA: 474 mg/m³ 8 hour(s). Form: Sum of vapour and particulatesTWA: 150 ppm 8 hour(s). Form: Sum of vapour and particulatesAustriaNo exposure limit value known.SwitzerlandNo exposure limit value known.BelgiumNo exposure limit value known.SpainNo exposure limit value known.TurkeyNo exposure limit value known.Czech RepublicNo exposure limit value known.Irelandpropane-1,2-diol NAOSH (Ireland, 8/2007).OELV-8hr: 10 mg/m³ 8 hour(s). Form: particulateOELV-8hr: 470 mg/m³ 8 hour(s). Form: vapour and particulatesOELV-8hr: 150 ppm 8 hour(s). Form: vapour and particulatesItalyNo exposure limit value known.EstoniaNo exposure limit value known.Lithuaniapropane-1,2-diol Del Lietuvos Higienos Normos (Lithuania, 10/2007).TWA: 7 mg/m³ 8 hour(s).SlovakiaNo exposure limit value known.HungaryNo exposure limit value known.PolandNo exposure limit value known.SloveniaNo exposure limit value known.Latviapropane-1,2-diolGreeceNo exposure limit value known.LV Nat. Standardisation and Meterological Centre (Latvia,5/2007).TWA: 7 mg/m³ 8 hour(s).Date of issue : 14/06/2011. 3/6


Energy saver F6 500ml8. Exposure controls/personal protectionPortugalNo exposure limit value known.Recommended monitoringproceduresExposure controlsOccupational exposurecontrolsHygiene measures ::If this product contains ingredients with exposure limits, personal, workplaceatmosphere or biological monitoring may be required to determine the effectivenessof the ventilation or other control measures and/or the necessity to use respiratoryprotective equipment. Reference should be made to European Standard EN 689 formethods for the assessment of exposure by inhalation to chemical agents andnational guidance documents for methods for the determination of hazardoussubstances.: No special ventilation requirements. Good general ventilation should be sufficient tocontrol worker exposure to airborne contaminants. If this product containsingredients with exposure limits, use process enclosures, local exhaust ventilation orother engineering controls to keep worker exposure below any recommended orstatutory limits.Wash hands, forearms and face thoroughly after handling chemical products, beforeeating, smoking and using the lavatory and at the end of the working period.Appropriate techniques should be used to remove potentially contaminated clothing.Wash contaminated clothing before reusing. Ensure that eyewash stations andsafety showers are close to the workstation location.Respiratory protection :Use a properly fitted, air-purifying or air-fed respirator complying with an approvedstandard if a risk assessment indicates this is necessary. Respirator selection mustbe based on known or anticipated exposure levels, the hazards of the product andthe safe working limits of the selected respirator. Recommended: None assigned.Hand protection:Chemical-resistant, impervious gloves complying with an approved standard shouldbe worn at all times when handling chemical products if a risk assessment indicatesthis is necessary.


Energy saver F6 500ml10.StabilityStability and reactivityConditions to avoidMaterials to avoid :Hazardous decompositionproducts11.:::The product is stable.No specific data.No specific data.Toxicological informationPotential acute health effectsInhalationIngestionSkin contactEye contactAcute toxicityOver-exposure signs/symptomsUnder normal conditions of storage and use, hazardous decomposition productsshould not be produced.: Exposure to decomposition products may cause a health hazard. Serious effectsmay be delayed following exposure.: Acute oral toxicity (LD50) Rat >2000 mg/Kg No known significant effects or criticalhazards.: No known significant effects or critical hazards.:No known significant effects or critical hazards.12.Ecological informationAquatic ecotoxicityBiodegradabilityOther adverse effectsAOX13.Disposal considerationsMethods of disposalHazardous waste :14.International transport regulationsRegulatoryinformationTransport informationADR/RID Class: No known significant effects or critical hazards.: The product does not contain organically bound halogens which could lead to anAOX value in waste water.:UN numberThe generation of waste should be avoided or minimised wherever possible.Dispose of surplus and non-recyclable products via a licensed waste disposalcontractor. Disposal of this product, solutions and any by-products should at alltimes comply with the requirements of environmental protection and waste disposallegislation and any regional local authority requirements.16 03 04 inorganic wastes other than those mentioned in 16 03 03Within the present knowledge of the supplier, this product is not regarded ashazardous waste, as defined by EU Directive 91/689/EEC.Proper shippingname- - -IMDG Class Not - - -regulated.IATA Class Not --regulated.PG* : Packing groupNotregulated.ClassesPG* Label-Additionalinformation---Date of issue : 14/06/2011. 5/6


Energy saver F6 500ml15.Regulatory informationEU regulationsClassification and labeling have been determined according to EU Directives 67/548/EEC and 1999/45/EC(including amendments) and take into account the intended product use.Risk phrasesProduct use::This product is not classified according to EU legislation.Consumer applications, Industrial applications.GermanyHazard class for waterItalyEmission control directive :16.HistoryOther informationDate of printing:2 Appendix No. 4Not classified.20/07/2011.Date of issue: 14/06/2011.Date of previous issue : 14/04/2011.VersionPrepared byNotice to reader:::3Not available.Indicates information that has changed from previously issued version.ReferencesThe Health and Safety At Work Act 1974, section 6.Control of Substances Hazardous to Health (CoSHH) Regulations 2002 and its amendments.Preparation contains soley TSCA and REACh 1907/2006 listed substances.This safety data sheet has been prepared in accordance with the requirements of the Chemicals (HazardInformation and Packaging for Supply) Regulations 2002 which implement EC Directives 1999/45/EC and2001/58/EC and their amendments.To the best of our knowledge, the information contained herein is accurate. However, neither the abovenamedsupplier, nor any of its subsidiaries, assumes any liability whatsoever for the accuracy orcompleteness of the information contained herein.Final determination of suitability of any material is the sole responsibility of the user. All materials maypresent unknown hazards and should be used with caution. Although certain hazards are described herein,we cannot guarantee that these are the only hazards that exist.Date of issue : 14/06/2011. 6/6