riflex m1 - Rittmeyer
riflex m1 - Rittmeyer
riflex m1 - Rittmeyer
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
99.993%<br />
RIFLEX M11<br />
Redundancy<br />
• Perfect integration with RRITOP<br />
process control system<br />
and other systems based on IEC 60870-5-104<br />
• Hi High h availability il bili d due to hhot<br />
t standby db and d continuous i<br />
redundancy up to the perippherals<br />
• Based on RIFLEX M1 stanndard<br />
modules<br />
• Comfortable operation andd<br />
diagnosis
Arguments for RIFLEX M1 Reddundancy<br />
� Application for complex processes, which require high availablility<br />
� Complete redundancy from process control system RITTOP<br />
to process I/O<br />
� Interface to non redundant systems<br />
� CComplete l t integration i t ti iinto t automation t ti system t RIFLEX MM1<br />
M1, M based b d on the th<br />
same module family<br />
Function<br />
� Active station works like „non redundant“.<br />
Transfer of process I/O‘s to passive station<br />
� Passive station processes no process I/O I/O‘s s,<br />
generates its own „result variables“<br />
� Synchronised processing on both stations<br />
First synchronisation at startup of passive station<br />
� Failure of active station: automatic switch-over<br />
to passive station, switch-over time < 1s<br />
Pulse-free switch-over with field bus I/O<br />
Hardware architecture (2 typica<br />
with redundant RIFLEX M1 process interfaces<br />
Communication<br />
Communication via IEC 60870-5-104<br />
with redundant or non redundant:<br />
� RIFLEX M1<br />
� Process control system RITOP<br />
� Various third-party systems<br />
Operation, Diagnosis, Configuuration<br />
Operation p<br />
Diagnosis g<br />
� Via RITOP, Diagnosis, WinKP or<br />
IEC 60870-5-104 variables<br />
� Functions: Switching on/off/over<br />
of redundancy, first synchronisation<br />
0082714.E01<br />
Subject to change<br />
al versions)<br />
Commmunication<br />
with non redundant systems<br />
Connnection<br />
via non redundant RIFLEX M1:<br />
� RIFFLEX<br />
remote control, IEC 60870-5-101, IEC 60870-5-103,<br />
IECC<br />
61850, Modbus, etc.<br />
� Display of settup,<br />
status of<br />
both stations,<br />
status of syn-<br />
chronisation llink<br />
� Operation of redundancy<br />
Process<br />
Control Level<br />
Automation Level<br />
<strong>Rittmeyer</strong> AG, Postfach 464, Inwilerriedstrasse 57, CH-6341<br />
Baar<br />
Tel. +41 (0)41 767 10 00, Fax +41 (0)41 767 10 70, www.rittmeyer.com, E-Mail: info@rittmeyer.com<br />
Subsidiaries in: Germany, Austria, Italy, Spain, France, Croatia, Slovakia,<br />
Czech Republic<br />
Sales office in the US, representative office in Singapore<br />
Field Level<br />
with IEC 60870-5-104 field bus I/O<br />
201005 Kä<br />
Configuration<br />
� With WinKP: identical configuration in<br />
both stations<br />
� Download incl. details of redundancy<br />
� Modifications of configuration with tool<br />
43.040.0003000.001.01.4.4<br />
Printed in Switzerland