10.07.2015 Views

HySense PR 100 - Hydrotechnik

HySense PR 100 - Hydrotechnik

HySense PR 100 - Hydrotechnik

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>HySense</strong> <strong>PR</strong> <strong>100</strong>6 pole device connector, M16 x 0.75DimensionsA11,5~ 32121092M12x1BØ 18,9Ø 22A 6 pole device connectorB ISO 228 – G¼ AC Restrictor insert Ø 0.6 for measuring ranges> 0 ... 60 bar (0 ... 6.0 MPa)D Profi le seal ring acc. to DIN 3869, FKME SW 22EDCQualitiesMeasuring principlePin assignment465321piezo-resistive (poly-cristalline silicon thin fi lmstructure on high-grade steel membrane)relative pressure0 ... 20 mAPressure typeOutput signalElectrical measuring connector 6 pole device connector, M16 x 0.75Mechanical measuring connector ISO 228 – G ¼ ASealing materialprofi le seal ring acc. to DIN 3869, FKMProtection type (EN 60529 / IEC 529) IP 40Casing materialnon-corrosive high-grade steelMembrane materialnon-corrosive high-grade steelTightening torque40 Nm (± 5 Nm)Weight~ 85 g0 ... 20 mA (three wires)Pin 1 = Signal +Pin 2 = – Ub / Signal – / GNDPin 3 = + UbPin 4 = freePin 5 = freePin 6 = ISDSMeasuring rangeOrder numberbar MPa 0 ... 20 mA-1 ... 6 -0.1 ... 0.6 3403-32-S-E5.330 ... 60 0 ... 6.0 3403-21-S-E5.330 ... 200 0 ... 20 3403-10-S-E5.330 ... 400 0 ... 40 3403-15-S-E5.330 ... 600 0 ... 60 3403-18-S-E5.33U3403-32-S-E5.33EN • 2009/10 • 1/2Other output signals on request.Measuring ranges > <strong>100</strong>0 ... 4000 bar (<strong>100</strong> ... 400 MPa) on request.<strong>Hydrotechnik</strong> GmbH Holzheimer Str. 94-96D-65549 Limburg • GermanyPhone +49 (0) 6431 4004-0Fax +49 (0) 6431 45308www.hydrotechnik.cominfo@hydrotechnik.com


<strong>HySense</strong> <strong>PR</strong> <strong>100</strong>6 pole device connector, M16 x 0.75Technical data <strong>PR</strong> <strong>100</strong>Over load range1.5 x nominal pressureBurst pressure3 x nominal pressureSignal typetwo wires analog (at 4 ... 20 mA), three wires analog (at 0 ... 10 VDC)Supply voltage Ub10 ... 30 VDCCurrent consumption6.5 mAOvervoltage protection32 VDCError limit (of fi nal value)comprises the infl uences non-linearity, hysterese, repeatability, zero-point- and span error... at +22 °C (room temperature) ± 0.25 %... at -15 ... +85°C < ± 1.0 %... at +85 ... +<strong>100</strong>°C < ± 2.5 %... at -40 ... -15°C < ± 2.5 %Compensation temperature range -40 ... +<strong>100</strong> °CNon-linearity< ± 0.4 % of fi nal valueReproducability< ± 0.1 % of fi nal valueHysteresis< ± 0.1 % of fi nal valueLong-term stability< ± 0,1 % of fi nal value/yearResponse time < = 1 ms (10 ... 90 %)Frequency range< = 1 kHzIsolation resistancemin. <strong>100</strong> MΩTotal resistanceR G= (Ub -10 V) / 10 mANo of load cycles > 1 x 10 7Medium temperature -40 ... +125 °CEnvironmental temperature-40 ... +105 °C (short term +125 °C)Storage temperature -40 ... +125 °CEMC test EN 50081-2, EN 50082-2Vibrational stability 5 mm 10 ... 32 Hz, 20 g 32 ... 500 Hz, DIN EN 60068-2-6Shock resistance50 g (11 ms half sine)Mounting orientationarbitraryU3403-32-S-E5.33EN • 2009/10 • 2/2<strong>Hydrotechnik</strong> GmbH Holzheimer Str. 94-96D-65549 Limburg • GermanyPhone +49 (0) 6431 4004-0Fax +49 (0) 6431 45308www.hydrotechnik.cominfo@hydrotechnik.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!