<strong>ADA</strong> <strong>8x8</strong> Central Unit


Notes<br />

AUDICO SYSTEMS OY<br />

P.O.Box 39<br />

Ruunikkokatu 2<br />

Fi 20381 Turku<br />

Finland<br />

Tel. + 358 –2 – 415 5400<br />

Fax. + 358 –2 – 415 5450<br />

audico@audico.fi<br />

www.audico.fi


The real heart of the digital <strong>Audico</strong> <strong>Avec</strong>, Public Address<br />

and Voice Evacuation system, is the <strong>Audico</strong><br />

<strong>ADA</strong> <strong>8x8</strong> central unit.<br />

The <strong>ADA</strong> <strong>8x8</strong> is a very effective and compact unit. It<br />

has versatile analog and digital audio inputs, effective<br />

digital signal processing circuitry and matrix, built-in<br />

prerecorded spoken message player and even 8 digital<br />

150W power amplifiers. The <strong>Audico</strong> <strong>Avec</strong> accommodates<br />

also system surveillance according to EN<br />

60849 standard. It’s certified by authorized certification<br />

body.<br />

All this in a single 2U high 19” device.<br />

<strong>Audico</strong> <strong>Avec</strong> digital Public Address and Voice Evacuation system<br />

AUDICO <strong>ADA</strong> <strong>8x8</strong> CENTRAL UNIT<br />

<strong>Audico</strong> <strong>Avec</strong> is configured using intuitive and easy to use <strong>Avec</strong> software, the file is finally downloaded to the <strong>ADA</strong> <strong>8x8</strong><br />

V 1.01<br />

• EN 60849 certified Voice Evacuation system<br />

• 8 independent 150W @ 8 Ohms amplifiers<br />

• Digital matrix 7x8<br />

• 7 analog audio inputs, mic/line level<br />

• 2 digital SPDIF inputs<br />

• Built-in message/advertisement player<br />

• Messages in USB-memory-stick<br />

• Calendar and timer functions<br />

• Phantom voltage for microphones<br />

• 8 control contact inputs<br />

• 8 control contact output<br />

• System bus for top hierachy level devices<br />

• Local bus for lower hierachy devices<br />

• Efficient signal processing (DSP)<br />

• Volume and source controls on users’ panel<br />

• RS 232 serial input for external control


MAINS INLET AND FUSES<br />

<strong>ADA</strong> <strong>8x8</strong> is connected to 230V operation voltage<br />

using standard mains plug.<br />

<strong>ADA</strong> <strong>8x8</strong> contains two separate parallel low voltage<br />

power units. Both power supplies have dedicated<br />

fuse at the rear panel.<br />

<strong>ADA</strong> <strong>8x8</strong> must be equipped with external UPS device<br />

when erecting a system according to the EN 60849<br />

standard.<br />

Fuse size is 3,15AT<br />

SPEAKER OUTPUTS<br />

<strong>ADA</strong> <strong>8x8</strong> contains 8 pcs 150W digital power amplifiers.<br />

8 Ohms loudspeakers may be connected directly to<br />

the speaker outputs. When 50-70-100V speakers<br />

are used the <strong>ADA</strong> <strong>8x8</strong> must be equipped with ALT<br />

<strong>8x8</strong> line transfer unit. It converts the 8 Ohms outputs<br />

to desired line voltage.<br />

The ALT <strong>8x8</strong> provides also priority voltage outputs,<br />

individually for each line (24VDC).<br />

RS-232 INTERFACE<br />

The RS232 interface at the rear is used for monitoring<br />

the running of the <strong>ADA</strong> <strong>8x8</strong>’s operation system.<br />

Suitable software is for example Windows Hyperterminal.<br />

<strong>ADA</strong> <strong>8x8</strong> can be controlled thru USB port<br />

using special RS232/USB adapter.<br />

24VDC OPERATION VOLTAGE OUTPUT<br />

The 24DC power output is used to supply power to<br />

the ALT <strong>8x8</strong> line transfer unit. The same voltage is<br />

used also for priority voltage. Priority voltage is used<br />

to bypass possible attenuators in rooms during paging<br />

or alarm to ensure the message is heard everywhere<br />

in the building.<br />

DIGITAL OPTICAL INPUTS AND OUTPUTS<br />

(SPDIF)<br />

<strong>ADA</strong> <strong>8x8</strong> can handle digital audio signals directly.<br />

Digital audio is brought to <strong>ADA</strong> <strong>8x8</strong> by using optical<br />

SPDIF-cable.<br />

The optical inputs are activated by configuration software,<br />

the corresponding analog inputs must be disabled.<br />

SPDIF input 1 is parallel to analog inputs 1 and 2,<br />

SPDIF 2 is parallel to analog inputs 5 and 6.<br />

FAN<br />

The <strong>ADA</strong> <strong>8x8</strong> is equipped with a fan. The rotation of<br />

fan is also monitored and any fault is reported to surveillance<br />

system.


SYSTEM & LOCAL OVERRIDE AUDIO OUT<br />

Both paging and alarm signals can be configured to<br />

these outputs. The outputs are mainly intended to<br />

feed paging audio to external amplifers or other systems.<br />

CTRL ALT <strong>8x8</strong> CONTROL DATA TO ALT <strong>8x8</strong><br />

The ALT <strong>8x8</strong> delivers priority voltage to wanted lines<br />

according the data from <strong>ADA</strong> <strong>8x8</strong>.<br />

DEVICE ADDRESS DIP-SWITCH<br />

Every <strong>ADA</strong> <strong>8x8</strong> in a system must have own individual<br />

device address in the same order as they appear on<br />

the configuration software. The first main unit has<br />

address one, then two etc.<br />

CONTROL OUTPUTS<br />

The control outputs may be configured to activate on<br />

diverse situations, like paging, alarm, fault-indication,<br />

firebell muting etc. The output is open-collector type.<br />

CONTROL INPUTS<br />

The control inputs may be used to active different<br />

<strong>ADA</strong> <strong>8x8</strong> actions like activate a paging, change preset,<br />

play message, alarm etc.<br />

MIC/LINE INPUTS<br />

7 pcs microphone/line inputs.The connector is removable<br />

3-pins plug. Each input has own input sensitivity<br />

trimmer. The mic/line selection is done using the<br />

configuration software.<br />

SYSTEM BUS & LINK<br />

<strong>Audico</strong> <strong>Avec</strong> devices are connected together using<br />

either system or local bus. The devices connected to<br />

the system bus can be used to control all <strong>ADA</strong> <strong>8x8</strong>’s<br />

in a single installation. Maximum number of devices<br />

in a single bus is 32.<br />

LOCAL BUS<br />

The local bus is used to connect devices that are<br />

intended to be used only locally within the cover area<br />

of a single <strong>ADA</strong> <strong>8x8</strong>. Typically local paging unit and<br />

volume controllers are such locally operated devices.<br />

USB-MEMORY STICK CONNECTOR<br />

The alarm and other messages are stored in wavformat<br />

to a USB-memory stick. The stored sound files<br />

can be played as chime, alarm or information message<br />

triggered by timer, paging, control input or a fault<br />

etc.<br />

There is another USB - jack inside the <strong>ADA</strong> <strong>8x8</strong> for<br />

non-removable messages.


<strong>ADA</strong> <strong>8x8</strong> simplified block diagram


<strong>ADA</strong> <strong>8x8</strong> CENTRAL UNIT<br />

<strong>Audico</strong> code 30010<br />

EAN code 6430029190019<br />

Signal processing and routing characteristics<br />

8 digital power 150W @ 8 Ohms amplifiers<br />

7 analog audio inputs, configurable either to mic or line level<br />

Phantom-voltage for electret microphones<br />

2 SPDIF digital stereo inputs<br />

2 SPDIF digital stereo outputs<br />

Internal message player, security messages in internal memory,<br />

unlimited number of messages in USB memory stick. (wav)<br />

Input channels digital signal processing (DSP), 7 channels<br />

Input level, mic or line<br />

Type of signal: digital/analog<br />

Parametric equalizer, 3 band<br />

Digital routing<br />

Level control<br />

Output channels digital signal processing (DSP), 8 channels<br />

Tone control<br />

Parametric equalizer, 5 band<br />

High pass filter, frequency freely selectable<br />

12 or 24 dB/octave, filter: Butterworth, Linkwitz- Riley or<br />

Bessel<br />

Delay max 4ms<br />

Compressor /limiter<br />

Volume control<br />

Connection buses and I/O’s<br />

Local bus (CAT5) for paging and control devices operational within<br />

one <strong>ADA</strong> <strong>8x8</strong> only<br />

System bus (CAT5) for paging and control devices operational over<br />

whole system, max 32 devices<br />

System bus link connector for chaining to next <strong>ADA</strong> <strong>8x8</strong><br />

Front panel USB connector for configuration file down/upload<br />

Rear panel and internal USB jacks for message memory sticks<br />

8 control contact inputs, operation configurable<br />

8 control contact outputs, operation configurable<br />

Priority data for controlling the ALT <strong>8x8</strong> line transfer unit<br />

System operation<br />

System is expandable by adding required number of <strong>ADA</strong> <strong>8x8</strong> units.<br />

Up to 256 speaker lines / paging zones<br />

Possibility to use local programme sources in any <strong>ADA</strong> <strong>8x8</strong>.<br />

System surveillance:<br />

Device and system monitoring according to EN-60849 standard<br />

Automatic switch-over to a another <strong>ADA</strong> <strong>8x8</strong> if master <strong>ADA</strong> fails<br />

Power supply voltage and temperature monitoring<br />

Fan rotation monitoring<br />

Requirement for Voice Evacuation System’s Main<br />

User<br />

Standard EN-60849 sets also guidelines for the user<br />

of the installed system. The main user must take care<br />

of system maintenance, testing, keep the logbook<br />

and ensure all other users are well trained to use the<br />

system.<br />

We have prepared a booklet guiding the user as well<br />

the installation and service companies to set-up and<br />

run a system according the EN standard.<br />

V 1.01<br />

<strong>Audico</strong> <strong>Avec</strong> digital Public Address and Voice Evacuation system<br />

TECHNICAL CHARACTERISTICS<br />

Operation voltage 230VAC<br />

Max power 950W<br />

Required maximum alarm-on UPS capacity is 1kVA<br />

Required ready-state UPS capacity is 200VA<br />

(system on but no audio signal)<br />

Analog audio inputs 7 pcs<br />

Control I/O’s 8 / 8 pcs (open-collector)<br />

SPDIF in/out 2 pcs<br />

System bus max 32 device, CAT 5<br />

Local bus max 32 device, CAT 5<br />

Outputs 8 pcs each 150W@8 Ohms<br />

The <strong>ADA</strong> <strong>8x8</strong> is Rohs-compliant, it is tested according<br />

all relevant safety and electromagnetic compatibility<br />

standards (EMC).<br />

The <strong>Audico</strong> <strong>Avec</strong> product family is certified according<br />

to EN-60849 standard (Sound System for Emergency<br />

Purposes).<br />

Dimensions<br />

W x H x D 483 x 88 x 380 mm<br />

Carton W x H x D 540 x 460 x 170 mm<br />

Volume 0,042m 3<br />

Weight / net 8,5 kg<br />

Weight / gross 9 kg<br />

Accessories<br />

- mains cable with Schuko-plug<br />

- USB A-B cable for downloading<br />

- 1 GB USB memory stick<br />

- installation and operation manuals<br />

- configuration manual


AUDICO AVEC ACCESSORIES<br />

ALT <strong>8x8</strong> Transformer unit<br />

• Used to convert <strong>ADA</strong> <strong>8x8</strong>’s low impedance<br />

outputs to 50-70-100V lines<br />

• Supplies also 24VDC priority voltage<br />

AAE 800 Paging and control unit<br />

• Paging<br />

• Programme selection and volume control<br />

• Preset activation<br />

AAE 804 Fireman’s microphone<br />

• High priority paging<br />

• Prerecorded evacuation message play buttons<br />

<strong>Audico</strong> <strong>Avec</strong> configuration software<br />

• Used to set-up the system<br />

• Runs in a standard Windows PC<br />

• Requires USB-port<br />

• Requires installation of a USB gadget-driver<br />

AUDICO SYSTEMS OY<br />

P.O. Box. 39 (Ruunikkokatu 2)<br />

20381 Turku, Finland<br />

Tel. +358- 2- 415 5400<br />

Fax: +358- 2- 415 5450<br />

VAT FI 0982651-1<br />

AAE 806 Paging and control unit<br />

• Paging<br />

• Programme selection and volume control<br />

• Preset activation<br />

• 6 buttons to play prerecorded messages<br />

AAI 800 Preset buttons and audio input<br />

• 3 Preset activation buttons<br />

• Audio input with level control<br />

ASV 800 Programme and volume control<br />

• Up-down buttons to choose channel<br />

• Up-down buttons to set volume<br />

AEU 100 Line end unit<br />

• Improves line monitoring performance<br />

• Installed to end of each monitored speakerline<br />

www.audico.fi<br />

audico@audico.fi

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!