10.07.2015 Views

Pan Arab Journal of Oncology - Arab Medical Association Against ...

Pan Arab Journal of Oncology - Arab Medical Association Against ...

Pan Arab Journal of Oncology - Arab Medical Association Against ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

original article <strong>Pan</strong> <strong>Arab</strong> <strong>Journal</strong> <strong>of</strong> <strong>Oncology</strong> | vol 6; issue 1 | March 2013rectum in the PTV and thus conforms the dose to the target volume and achievesa higher level <strong>of</strong> rectum sparing. This increases the scope for dose escalation.However this is commonly associated with areas <strong>of</strong> under-dosage in the targetvolume 2The accurate outlining <strong>of</strong> the target volumes, margins, rectum and bladder iscrucial in prostate IMRT. Reduction in the margin without immobilisation <strong>of</strong> thepatient may lead to under-dosing <strong>of</strong> the target volume 3 .Prostate motion could cause more than 5mm shift in the anterior direction.This can affect the target coverage and expose a greater volume <strong>of</strong> rectum tohigh doses resulting in high incidence <strong>of</strong> rectal bleeding. Problems relating tounacceptable dose to the rectum limit escalation <strong>of</strong> the prostate dose more thanproblems affecting the bladder 4- 6The probability <strong>of</strong> tumour control and normal tissue complications afterradiation therapy are dose dependent. The tolerance dose <strong>of</strong> critical structuresis also dependent on the volume <strong>of</strong> irradiated normal tissues within the PTV. 5,7,8MethodsCT studies <strong>of</strong> ten randomly selected patients with low risk prostate cancer fromfuture hand oncology centre (age ranges 51-78, mean 69 years) planned andcalculated with 15 MV photon beam on CMS treatment planning system (Xio,Germany) using the data for the 15MV photon beam <strong>of</strong> Primus linear accelerator(Siemens, Germany). The CT scan slices were spaced 5mm from the sacroiliacjoint to the lesser trochanter. All patients scanned in a supine position with acomfortably full bladder.Various volumes <strong>of</strong> interest were defined: CTV (prostate and seminal vesicle),PTV2 (prostate+1.0cm margin) and PTV1 (CTV+1.0cm margin) were outlined.Organs at risk (OAR) including rectum, bladder and femoral heads were outlined.Bladder and rectum were defined by contouring the whole organ including thecontents.www.amaac.org

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!